Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A cost and utility analysis of NIM/CAMAC standards and equipment for shuttle payload data acquisition and control systems. Volume 3: Tasks 3 and 4

The modifications for the Nuclear Instrumentation Modular (NIM) and Computer Automated Measurement Control (CAMAC) equipment, designed for ground based laboratory use, that would be required to permit its use in the Spacelab environments were determined. The cost of these modifications were estimated and the most cost effective approach to implementing them were identified. A shared equipment implementation in which the various Spacelab users draw their required complement of standard NIM and CAMAC equipment for a given flight from a common equipment pool was considered. The alternative approach studied was a dedicated equipment implementation in which each of the users is responsible for procuring either their own NIM/CAMAC equipment or its custom built equivalent.

Source record↗

Advanced Fuel Cycle Cost Basis Report: Module D1-7 Contact-Handled Pelletized Pressurized Heavy Water (PHWR) UOX Fuel Fabrication (Rev.1)

In addition to literature-based pressurized heavy-water reactor (PHWR) fuel price information in the 2017 AFC-CBR, the what-it-takes (WIT) unit cost data in this update is informed by new analysis and escalation of the 1978 PHWR-UOX fuel life cycle cost (LCC) data from ORNL reports prepared for the 1977–1980 Nonproliferation Alternative Systems Assessment Program (NASAP). (These reports are referenced and summarized in detail in Module D1-PR.) The PHWR fuel fabrication LCC data in these reports is scaled from a bottom-up cost estimate for a reference technology pressurized-water reactor (PWR)—uranium oxide (UOX) fuel fabrication plant by using algorithms that consider the manufacturing process complexity, fuel design complexity, plant floor space requirements, and the radiation and health, safety, and environmental (HS&E) regulatory environment of PHWR-UOX fuel production vis-à-vis light-water reactor (LWR)-UOX production (PWR fuel in this case). The module name has been changed from “Canadian Deuterium Uranium (CANDU)” to the more generic PHWR fuel fabrication in recognition that not all power reactors that might use this fuel type are considered. Unfortunately, the detailed algorithms and their design bases were not archived at the end of the NASAP effort of the commercial CANDU concept specifically developed in the middle of the last century by Atomic Energy of Canada Limited (AECL).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NASA metrology information system: A NEMS subsystem

the NASA Metrology Information Systems (NMIS) is being developed as a standardized tool in managing the NASA field Center's instrument calibration programs. This system, as defined by the NASA Metrology and Calibration Workshop, will function as a subsystem of the newly developed NASA Equipment Management System (NEMS). The Metrology Information System is designed to utilize and update applicable NEMS data fields for controlled property and to function as a stand alone system for noncontrolled property. The NMIS provides automatic instrument calibration recall control, instrument historical performance data storage and analysis, calibration and repair labor and parts cost data, and instrument user and location data. Nineteen standardized reports were developed to analyze calibration system operations.

German, E. S., Jr.↗

Community Geothermal: Energy, Cost, and Carbon Modeling for District Design - Ann Arbor, MI

This data includes results on an analysis of existing and projected energy, cost, and carbon for the City of Ann Arbor - District Geothermal Design and Deployment to Equitably Decarbonize Low Income Neighborhoods in Ann Arbor project. The scope of the project includes designing and implementing a geothermal district heating and cooling system that reduces thermal heating and cooling load by 75% and greenhouse gas emissions by 40% in the project area (262 households, 6 commercial buildings). The existing neighborhood was modeled using Design Builder, an EnergyPlus software, to understand the current energy load. The energy model was then flipped to reflect the designed district geothermal heating and cooling system to project the effect on energy, carbon, and cost. This dataset includes the analysis files utilized and created for this study. There are 3 categories of data: 1) existing/benchmarking, 2) energy modeling, and 3) post processed calculations. This follows the methodology and process of the project team, which is fully explained in file 00_Technical Economic Environmental Assessment. All uses of data are referenced throughout this assessment to their respective files included below.

15 GEOTHERMAL ENERGY↗

A case study of tuning MapReduce for efficient Bioinformatics in the cloud

The combination of the Hadoop MapReduce programming model and cloud computing allows biological scientists to analyze next-generation sequencing (NGS) data in a timely and cost-effective manner. Cloud computing platforms remove the burden of IT facility procurement and management from end users and provide ease of access to Hadoop clusters. However, biological scientists are still expected to choose appropriate Hadoop parameters for running their jobs. More importantly, the available Hadoop tuning guidelines are either obsolete or too general to capture the particular characteristics of bioinformatics applications. In this paper, we aim to minimize the cloud computing cost spent on bioinformatics data analysis by optimizing the extracted significant Hadoop parameters. When using MapReduce-based bioinformatics tools in the cloud, the default settings often lead to resource underutilization and wasteful expenses. We choose k-mer counting, a representative application used in a large number of NGS data analysis tools, as our study case. Experimental results show that, with the fine-tuned parameters, we achieve a total of 4× speedup compared with the original performance (using the default settings). Finally, this paper presents an exemplary case for tuning MapReduce-based bioinformatics applications in the cloud, and documents the key parameters that could lead to significant performance benefits.

97 MATHEMATICS AND COMPUTING↗

DAISY: A Rapid Approach to Evaluating Marine Energy Converter Sound (Final Technical Report)

This project’s objective was to improve the quality of acoustic information about marine energy converters that could be collected from groups of drifting hydrophones, while reducing the costs of deployment and data analysis. This was achieved through technology development addressing four focus areas: (1) minimizing flow-noise and self-noise, (2) integrating metadata streams into a single data acquisition system, (3) developing post-processing routines to facilitate rapid data review, and (4) enabling objective identification of marine energy converter sound against a backdrop of ambient noise using time-delay-of-arrival localization.

16 TIDAL AND WAVE POWER↗

Emission projections for the U.S. Environmental Protection Agency Section 812 Second Prospective Clean Air Act cost/benefit analysis

This paper describes the analysis, methods, and results of the recently completed emission projections. There are several unique features of this analysis. One is the use of consistent economic assumptions from the Department of Energy's Annual Energy Outlook 2005 (AEO 2005) projections as the basis for estimating 2010 and 2020 emissions for all sectors. Another is the analysis of the different emissions paths for both with and without CAAA scenarios. Other features of this analysis include being the first EPA analysis that uses the 2002 National Emission Inventory files as the basis for making 48-state emission projections, incorporating control factor files from the Regional Planning Organizations (RPOs) that had completed emission projections at the time the analysis was performed, and modeling the emission benefits of the expected adoption of measures to meet the 8-hr ozone National Ambient Air Quality Standards (NAAQS), the Clean Air Visibility Rule, and the PM2.5 NAAQS. This analysis shows that the 1990 CAAA have produced significant reductions in criteria pollutant emissions since 1990 and that these emission reductions are expected to continue through 2020. CAAA provisions have reduced volatile organic compound (VOC) emissions by approximately 7 million t/yr by 2000, and are estimated to produce associated VOC emission reductions of 16.7 million t by 2020. Total oxides of nitrogen (NOx) emission reductions attributable to the CAAA are 5, 12, and 17 million t in 2000, 2010, and 2020, respectively. Sulfur dioxide (SO{sub 2}) emission benefits during the study period are dominated by electricity-generating unit (EGU) SO{sub 2} emission reductions. These EGU emission benefits go from 7.5 million t reduced in 2000 to 15 million t reduced in 2020. 16 refs., 6 figs., 13 tabs.

01 COAL, LIGNITE, AND PEAT↗

Cascaded Control for Building HVAC Systems in Practice

Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational fluid dynamics overview

The hierarchy of codes; boundary layers and turbulence models; uniqueness and artificial viscosity; efficiency of solution algorithms; data display and analysis; and cost of experimental validation are briefly examined.

Bobbitt, Percy J.↗

Small Explorer (SMEX) POsitron Electron Magnet Spectrometer (POEMS)

This report covers the activities of Louisiana State University (LSU) under subcontract 26053-EX between LSU and the Bartol Research Institute (Bartol), which began January 1, 1994. The purpose of this subcontract was for LSU to participate in and support Bartol in the work to define the SMEX (Small Explorer)/POEMS (Positron Electron Magnet Spectrometer) spaceflight mission under NASA Contract NAS5-38098 between NASA and Bartol. The conclusions of this study were that for a 1998 launch into a 600km altitude, 98 degrees, approximately sun synchronous orbit, (a) the total radiation dose would be typically a few k-rad per year, certainly less than 20 k-rad per year for the anticipated shielding and potential solar flare environment, (b) detector counting rates would be dominated by the South Atlantic Anomaly (SAA) and the horns of the Van Allen belts, (c) the galactic electron and positron 'signal' can be extracted from the albedo background and the trapped populations by detailed evaluation of the geomagnetic transmission function (cut-off) for each event, (d) POEMS could make significant contributions to magnetospheric science if sufficient downlink capacity were provided and, (e) a fully functioning, cost efficient, data processing and analysis facility design was developed for the mission. Overall, POEMS was found to be a relatively simple experiment to manifest, operate and analyze and had potential for fundamental new discoveries in cosmic, heliospheric, solar and magnetospheric science.

LHeureux, Jacques↗

Characterizing Nearby Stars: Age and Activity

The funds in this grant were used to support costs for observing and data analysis over the past two years. During this time I have been obtaining low-resolution (R-2,000) spectra for about 5,000 solar-type stars (late-F and G dwarfs) that are within 60 parsecs of the Sun. The sample was defined with results from the Hipparcos mission, and the spectra were obtained at Kitt Peak National Observatory, using the Coude Feed telescope, and at Cerro Tololo Interamerican Observatory, using their 1.5 m telescopes for stars below -40 declination. Nearly all the observed spectra have been reduced and analyzed. What is determined is R-prime, an index of the chromospheric emission in the cores of the Ca II H and K lines relative to the nearby continuum, and normalized for the color of the star. Chromospheric emission arises from magnetic activity on the star, and that is turn is driven by rotation. Solar-type stars spin down as they age, and so they get weaker in their chromospheric emission as well. Thus this R-prime index can be used to estimate the ages of stars. A few stars remain to be observed at Kitt Peak, and follow-up high-resolution spectra are being obtained of the most active stars seen, but the majority of the starting sample have been completed. The spectra obtained are also being analyzed to yield an index of overall metallicity for each star, and this will be used to study Galactic evolution questions. These metallicities will form the first large dataset of high and consistent quality. Initial results from this work have been used to define targets for a SIRTF Legacy program, for stars to study for planetary transits, and for SETI efforts. Because of the large number of stars involved, most of the data will be made available on the web, although some specific papers about the results are in preparation. The web database is being constructed.

Soderblom, David↗

Statistical Treatment of Earth Observing System Pyroshock Separation Test Data

The Earth Observing System (EOS) AM-1 spacecraft for NASA's Mission to Planet Earth is scheduled to be launched on an Atlas IIAS vehicle in June of 1998. One concern is that the instruments on the EOS spacecraft are sensitive to the shock-induced vibration produced when the spacecraft separates from the launch vehicle. By employing unique statistical analysis to the available ground test shock data, the NASA Lewis Research Center found that shock-induced vibrations would not be as great as the previously specified levels of Lockheed Martin. The EOS pyroshock separation testing, which was completed in 1997, produced a large quantity of accelerometer data to characterize the shock response levels at the launch vehicle/spacecraft interface. Thirteen pyroshock separation firings of the EOS and payload adapter configuration yielded 78 total measurements at the interface. The multiple firings were necessary to qualify the newly developed Lockheed Martin six-hardpoint separation system. Because of the unusually large amount of data acquired, Lewis developed a statistical methodology to predict the maximum expected shock levels at the interface between the EOS spacecraft and the launch vehicle. Then, this methodology, which is based on six shear plate accelerometer measurements per test firing at the spacecraft/launch vehicle interface, was used to determine the shock endurance specification for EOS. Each pyroshock separation test of the EOS spacecraft simulator produced its own set of interface accelerometer data. Probability distributions, histograms, the median, and higher order moments (skew and kurtosis) were analyzed. The data were found to be lognormally distributed, which is consistent with NASA pyroshock standards. Each set of lognormally transformed test data produced was analyzed to determine if the data should be combined statistically. Statistical testing of the data's standard deviations and means (F and t testing, respectively) determined if data sets were significantly different at a 95-percent confidence level. If two data sets were found to be significantly different, these families of data were not combined for statistical purposes. This methodology produced three separate statistical data families of shear plate data. For each population, a P99.1/50 (probability/confidence) per-separation-nut firing level was calculated. By using the binomial distribution, Lewis researchers determined that this pernut firing level was equivalent to a P95/50 per-flight confidence level. The overall envelope of the per-flight P95/50 levels led to Lewis' recommended EOS interface shock endurance specification. A similar methodology was used to develop Lewis' recommended EOS mission assurance levels. The available test data for the EOS mission are significantly larger than for a normal mission, thus increasing the confidence level in the calculated expected shock environment. Lewis significantly affected the EOS mission by properly employing statistical analysis to the data. This analysis prevented a costly requalification of the spacecraft's instruments, which otherwise would have been exposed to significantly higher test levels.

McNelis, Anne M.↗

NASA Tech Briefs, November/December 1986, Special Edition

Topics: Computing: The View from NASA Headquarters; Earth Resources Laboratory Applications Software: Versatile Tool for Data Analysis; The Hypercube: Cost-Effective Supercomputing; Artificial Intelligence: Rendezvous with NASA; NASA's Ada Connection; COSMIC: NASA's Software Treasurehouse; Golden Oldies: Tried and True NASA Software; Computer Technical Briefs; NASA TU Services; Digital Fly-by-Wire.

Source record↗

The NASA L3 Study

The Astrophysics Implementation Plan calls for a minority role in L3, planned for launch in 2034. L3 The third large mission in ESAs Cosmic Visions 2015-2025 Programme NASA and ESA have been discussing a collaboration for 2 years Gravitational Observatory Advisory Team (GOAT) ESA study evaluating and recommend scientific performance tradeoffs, detection technologies, technology development activities, data analysis capabilities, schedule and cost US representatives: Guido Mueller, Mark Kasevich, Bill Klipstein, RTS Started in October 2014, concluding with a final report in late Marchor early April 2016. ESA solicited interest from ESA Member States in November 2015 NASA is continuing technology development support. ESA is restarting technology development activities.

The L3 Study organization and charter have been es↗

Oregon Offshore Wind Site Feasibility and Cost Study

The focus of this presentation is to: Reflect current floating wind technology trends and industry market data in cost models; Provide cost analysis in support of Oregon state energy planners considering floating offshore wind's potential contribution to future state energy supplies.

17 WIND ENERGY↗

Hydraulic Response to Thermal Stimulation Efforts at Raft River Based on Stepped Rate Injection Testing

The injection well stimulation project at the Raft River geothermal field tests the effect of long-term cold water injection and high pressure injection on well injectivity, improvements to which could reduce operating costs. The primary data for analysis and interpretation of the injection test are step-rate flow tests run before each new phase of the injection. These tests were analyzed using a combination of standard pump-test analytical solution methods and methods developed expressly for the observed conditions. The stepped rate injection tests, combined with long-term flow and pressure response data suggest that the well is located within a fractured formation of low transmissivity but high storativity. These calculated parameters appeared to increase with pressure during the first injection test and the higher values were reproduced during the second stepped rate test. Calculated transmissivity and storativity are on the order of 4E-5 m cm 2 and 1E-4 m Pa -1 , respectively. The apparent pressure dependence of fitted hydraulic parameters may reflect near-well fracture compliance that increased the effective radius of the wellbore during the first test. While the type curve fit analysis also suggests that the reservoir behaves as a uniformly fractured reservoir with a radial flow regime, the hydraulic parameters indicate that condition may exist only a very limited distance (<10 m) from the well. Longer-term pressure response suggests that flow in the system effectively reaches steady state in a period of less than a day, which may reflect pressure stabilization resulting from pressure-dependent permeability or a region of much higher permeability located with a few meters of the well. The transmissivity estimates obtained from this analysis, converted to approximate fracture density and aperture, provide useful constraints on the distance to which the thermal front may migrate from the well during the cold water injection phase of the stimulation project. We estimate that the cooling front will migrate less than a tenth of a kilometer over an approximately one-year injection period. Here, the effects of that cooling, however, may be substantial, because increases in permeability have maximum effect nearest the well.

cold water injection↗

A surrogate-based uncertainty quantification with quantifiable errors

Surrogate models are often employed to reduce the computational cost required to complete uncertainty quantification, where one is interested in propagating input parameters uncertainties throughout a complex engineering model to estimate responses uncertainties. An improved surrogate construction approach is introduced here which places a premium on reducing the associated computational cost. Unlike existing methods where the surrogate is constructed first, then employed to propagate uncertainties, the new approach combines both sensitivity and uncertainty information to render further reduction in the computational cost. Mathematically, the reduction is described by a range finding algorithm that identifies a subspace in the parameters space, whereby parameters uncertainties orthogonal to the subspace contribute negligible amount to the propagated uncertainties. Moreover, the error resulting from the reduction can be upper-bounded. The new approach is demonstrated using a realistic nuclear assembly model and compared to existing methods in terms of computational cost and accuracy of uncertainties. Although we believe the algorithm is general, it will be applied here for linear-based surrogates and Gaussian parameters uncertainties. The generalization to nonlinear models will be detailed in a separate article. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Epidural Analgesia Versus Patient-Controlled Analgesia for Pain Relief in Uterine Artery Embolization for Uterine Fibroids: A Decision Analysis

Purpose: This study was designed to compare the costs and effects of epidural analgesia (EDA) to those of patient-controlled intravenous analgesia (PCA) for postintervention pain relief in women having uterine artery embolization (UAE) for systematic uterine fibroids. Methods: Cost-effectiveness analysis (CEA) based on data from the literature by constructing a decision tree to model the clinical pathways for estimating the effects and costs of treatment with EDA and PCA. Literature on EDA for pain-relief after UAE was missing, and therefore, data on EDA for abdominal surgery were used. Outcome measures were compared costs to reduce one point in visual analogue score (VAS) or numeric rating scale (NRS) for pain 6 and 24 h after UAE and risk for complications. Results: Six hours after the intervention, the VAS was 3.56 when using PCA and 2.0 when using EDA. The costs for pain relief in women undergoing UAE with PCA and EDA were Euro-Sign 191 and Euro-Sign 355, respectively. The costs for EDA to reduce the VAS score 6 h after the intervention with one point compared with PCA were Euro-Sign 105 and Euro-Sign 179 after 24 h. The risk of having a complication was 2.45 times higher when using EDA. Conclusions: The results of this indirect comparison of EDA for abdominal surgery with PCA for UAE show that EDA would provide superior analgesia for post UAE pain at 6 and 24 h but with higher costs and an increased risk of complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗