Development of Data Reporting Standards for High-Temperature Gas-cooled Reactor (HTGR) Nuclear Energy University Program (NEUP) Thermal-Fluid Experiments

Since 2009, the U.S. Department of Energy (DOE) Office of Nuclear Energy's Nuclear Energy University Program (NEUP) has been at the forefront of nuclear research, specifically concentrating on advancing high-temperature gas-cooled reactor (HTGR) technologies. By Fiscal Year 2023, NEUP has authorized 35 projects dedicated to HTGR research, each contributing significantly to the enhancement of our understanding of this technology. The outcomes of these diverse projects have been disseminated through final NEUP reports, peer-reviewed journal articles, and presentations at academic conferences, forming a comprehensive tapestry of knowledge. Despite the substantial value of these findings, their dissemination has been fragmented, posing challenges for accessibility to researchers and policymakers and leading to underutilization of DOE investments. Recognizing this critical gap and its potential consequences for the future of nuclear research, the Advanced Reactor Technologies (ART) Gas-Cooled Reactor (GCR) program conducted an extensive survey of completed and ongoing HTGR NEUP projects. This survey enabled the compilation of crucial data, resulting in the development of a specialized public-access database tailored for computational fluid dynamics and system code validation, specifically designed for HTGR applications. However, the data collection process revealed a significant challenge in central data organization due to individual researchers from different institutes employing varying logics and preferences for recording and documenting experimental data. Consequently, an urgent need has been identified to establish a standardized reporting format for HTGR experimental projects. Addressing this issue is essential for enhancing collaboration, maximizing the impact of DOE investments, and ensuring the seamless advancement of HTGR technologies in nuclear research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HTGR Validation: NEUP Survey and Database - Data Reporting Standard for HTGR Thermal-Fluid Experiments

Since 2009, the U.S. Department of Energy (DOE) Office of Nuclear Energy's Nuclear Energy University Program (NEUP) has been at the forefront of nuclear research, specifically concentrating on advancing high-temperature gas-cooled reactor (HTGR) technologies. By Fiscal Year 2024, NEUP has authorized 36 projects dedicated to HTGR research, each contributing significantly to the enhancement of our understanding of this technology. The outcomes of these diverse projects have been disseminated through final NEUP reports, peer-reviewed journal articles, and presentations at academic conferences, forming a comprehensive tapestry of knowledge. Despite the substantial value of these findings, their dissemination has been fragmented, posing challenges for accessibility to researchers and policymakers and leading to underutilization of DOE investments. Recognizing this critical gap and its potential consequences for the future of nuclear research, the Advanced Reactor Technologies (ART) Gas-Cooled Reactor (GCR) program conducted an extensive survey of completed and ongoing HTGR NEUP projects. This survey enabled the compilation of crucial data, resulting in the development of a specialized public-access database tailored for computational fluid dynamics and system code validation, specifically designed for HTGR applications. However, the data collection process revealed a significant challenge in central data organization due to individual researchers from different institutes employing varying logics and preferences for recording and documenting experimental data. Consequently, an urgent need has been identified to establish a standardized reporting format for HTGR experimental projects. Addressing this issue is essential for enhancing collaboration, maximizing the impact of DOE investments, and ensuring the seamless advancement of HTGR technologies in nuclear research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technology Overview: Side Stream Filtration for Cooling Towers

The Federal Energy Management Program (FEMP) identified cooling tower side stream filtration as a technology that offers key benefits to the federal sector, including the potential to reduce energy and water use, decrease operating costs, and extend cooling equipment life. This overview provides agencies with key information to deploy side stream filtration systems that may otherwise be overlooked.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RELAP5-3D Modeling in the OECD-NEA HTTF Benchmark

Prismatic gas-cooled reactors are a technologically mature reactor concept of interest for near- to mid-term deployment. To accelerate the deployment of these reactors, the DOE's Advanced Reactor Technologies Gas-Cooled Reactor campaign is spearheading a thermal hydraulics code validation benchmark based on the High Temperature Test Facility at Oregon State University. This presentation provides an introduction to that benchmark and an overview of some of the RELAP5-3D validation activities stemming from that benchmark.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Compact, high-power superconducting radio-frequency accelerators for environmental applications

Electron-beam irradiation has been proven to destructively reduce or eliminate a wide variety of organic chemicals, viruses and bacteria from wastewater, as well as reducing sulfur and nitrous oxides emission from coal-fired power plants. It is estimated that there are approximately 30,000 such particle accelerators in use worldwide for industrial processes including surface and bulk processing of material, medical sterilization, and environmental remediation. Maximum beam power from accelerators used in these applications is currently limited to less than 500 kW, and a higher beam power is needed to reduce treatment costs. The market availability of continuous-wave (CW) electron-beam accelerators with power of the order of ~100 kW is also very limited. Superconducting radio-frequency (SRF) linear accelerators (linacs) are commonly used at basic research laboratories throughout the world due to their exceptionally high efficiency as compared to current industrial varieties. Recent advances in cryogenics, SRF thin films and high-power magnetrons allow for the design of increasingly compact and efficient CW SRF electron linacs in the energy range 1-10 MeV, with up to 1 MW of beam power. A new class of compact, high-efficiency electron-beam accelerators may provide cost-effective solutions for a range of industrial and environmental remediation applications, particularly with respect to tackling one such class of contaminants so-called “forever chemicals”, including per- and polyfluoroalkyl substances (PFASs), which are ubiquitous in a wide range of products and for which there is currently no effective destruction technology. We have recently demonstrated the key technologies required for such accelerators by: 1) operating a Nb3Sn SRF accelerating cavity cooled by commercial cryocoolers up to an accelerating gradient of 12.4 MV/m and 2) demonstrating the phase-locking as well as a high-efficiency power combining scheme for industrial magnetron transmitters. In this presentation, we will introduce the principles and benefits of MW-class SRF linacs, based on the conduction-cooled SRF technology that we have demonstrated for environmental remediation. We propose the development of a 4 MeV, 20 kW prototype to be built at Jefferson Lab as a first accelerator demonstrator unit. We will also present the results from samples study on the effect of electron-beam irradiation on so-called “forever chemicals” such as 1,4-dioxane and PFAS, using an existing multi-purpose 10 MeV, low-power, CW SRF linac at Jefferson Lab.

Ciovati, Gianluigi↗

Dry cooler contribution to LCOE in a sCO 2 power cycle for CSP

In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO 2 (sCO 2 ) based power cycles. Here, these cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700 °C.

14 SOLAR ENERGY↗

Thermal Hydraulics Validation Activities in the ART-GCR Campaign

The Advanced Reactor Technologies - Gas Cooled Reactor Campaign (ART-GCR) is part of the United States Department of Energy - Office of Nuclear Energy's Advanced Reactor Technologies program aimed at developing a High Temperature Gas-cooled Reactor (HTGR) which will offer enhancements in safety and efficiency. The Design, Methods, and Validation arm of the ART-GCR program provides experience and advanced tools for HTGR design and analysis. The Methods and Validation arm is developing data to validate predictions of decay heat removal through an extensive experimental campaign the Natural Convection Shutdown Heat Removal Test Facility at Argonne National Laboratory. In-core thermal hydraulics validation is being facilitated through the OECD/NEA's Thermal Hydraulic Code Validation Benchmark for High Temperature Gas-Cooled Reactors using HTTF Data. That benchmark contains code-to-code and code-to-data comparisons for 3 sets of HTGR thermal hydraulics phenomena. This ongoing benchmark activity has 16 participants from 9 countries developing leading insights into HTGR thermal hydraulics code validation. The ART-GCR campaign is also working on the development of state-of-the-art MOOSE-based models of the High Temperature Engineering Test Reactor (HTTR). Through the OECD/NEA's HTTR Loss of Forced Cooling (LOFC) program, the ART-GCR campaign is developing a multiphysics transient code validation benchmark based on 3 HTTR experiments that will provide an opportunity for international collaboration on multiphysics code validation.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Pipe Cooled Microreactors

Microreactor technologies are required to provide reliable carbon-free power generation in remote applications. The heat pipe cooled microreactor concept in particular offers notable advantages due to the passive operation of heat pipes enabling increased reliability and simplicity in a more compact form factor. There is a significant need for experimental work to aid and expedite the deployment of heat pipe microreactors due to their unique technological characteristics. Thus, there has been increased interest in heat pipe experiments by numerous institutions in order to support these efforts. The present work is a comprehensive review of heat pipe experiments, describing instrumentation, methods, phenomena of interest, and recent developments. In addition, legacy work on the operation of high-temperature heat pipes under irradiation is reviewed and discussed. Furthermore, the verification and validation efforts for the flagship heat pipe simulation code Sockeye are reviewed and requirements for future experiments are outlined. Lastly, future directions are proposed for heat pipe experimentation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An assessment of the global cooling supply chain and implications for critical minerals

The global room air conditioner (AC) industry has undergone rapid growth, and the U.S. and India now face new supply chain risks due to China’s dominant role in manufacturing and driving demand. As India’s room AC market and related electricity consumption increases with continued economic development, it faces dual challenges of supply chain vulnerabilities and power grid blackouts from higher peak loads. To mitigate supply chain vulnerabilities for high-efficiency cooling equipment and critical mineral inputs to AC components, there is an increasing need to diversify the supply chain and address energy security and peak load risks to both the U.S. and India. This report assesses the potential for diversifying supply chains and scaling up manufacturing of highly efficient cooling equipment technologies and related critical mineral inputs in the U.S. and India. Successful cooperation on these technologies will enable the U.S., India, and their Quadrilateral Security Dialogue (Quad) partners to diversify AC supply chains while meeting India’s large and growing demand for efficient cooling. In the similarly concentrated supply chain for critical minerals, the U.S. and India can work with Japan and Australia to leverage each country’s strengths in diversifying mining, processing, and refining while pursuing alternatives to materials with high supply chain risks and supporting increased recycling and circular economy approaches.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cryogenic Carbon Capture™ Technoeconomic Analysis

The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.

20 FOSSIL-FUELED POWER PLANTS↗

Water Recovery From Cooling Tower Plumes

According to studies by the UN and the US State Department, we are on the path to an extreme freshwater shortage by 2030. The US’s largest water withdrawal source is power plants, which account for 39% of total US freshwater withdrawals, mostly for cooling. Cooling towers are the most common cooling system. To solve these problems and enable efficient water- based cooling – Infinite Cooling’s novel technology uses electric fields to ionize the air, charge the escaping water leaving cooling towers and direct the water toward mesh collectors where it collects and gets recycled for use in the cooling system. This technology was developed at MIT and was reduced to practice on a lab-scale prototype, and a prototype at the MIT Cogeneration Power Plant. This DOE award funded taking this technology from a lab-scale prototype to TRL 5 on an operating cooling tower in the field at the MIT Nuclear Research Laboratory. The funding helped to design and optimize an electrostatic plume collection system and test it in high-fidelity lab setting and in actual field conditions on a cooling tower. Throughout the award, Infinite Cooling investigated the formation of plumes on cooling towers, used that information to optimize the design, material and electrical properties of the collection device and quantified the collection yield via flow rate and water quality.

20 FOSSIL-FUELED POWER PLANTS↗

Integration of IH 2 ® with Cool Reformer for the Conversion of Cellulosic Biomass to Drop In Fuels

GTI Energy has integrated the Cool Reformer technology with the IH 2® -50 pilot plant (which can process a maximum of 50kg/day of biomass feed) to demonstrate the suitability of this new reforming technology for producing hydrogen within IH 2 ® process. As part of this study, we showed that all of the hydrogen required for the IH 2® process could be produced from steam reforming the IH 2® light gas generated within the process and the system can be integrated in a cost-effective way compared to the use of standard SMRs.

08 HYDROGEN↗

Engineered Nanoporous Frameworks for Adsorption Cooling Applications

The energy demand for traditional vapor-compressed technology for space cooling continues to soar year after year due to global warming and the increasing human population’s need to improve living and working conditions. Thus, there is a growing demand for eco-friendly technologies that use sustainable or waste energy resources. Here this review discusses the properties of various refrigerants used for adsorption cooling applications followed by a brief discussion on the thermodynamic cycle. Next, sorbents traditionally used for cooling are reviewed to emphasize the need for advanced capture materials with superior properties to improve refrigerant sorption. The remainder of the review focus on studies using engineered nanoporous frameworks (ENFs) with various refrigerants for adsorption cooling applications. The effects of the various factors that play a role in ENF–refrigerant pair selection, including pore structure/dimension/shape, morphology, open-metal sites, pore chemistry and possible presence of defects, are reviewed. Next, in-depth insights into the sorbent–refrigerant interaction, and pore filling mechanism gained through a combination of characterization techniques and computational modeling are discussed. Finally, we outline the challenges and opportunities related to using ENFs for adsorption cooling applications and provide our views on the future of this technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multicaloric Cryocooling Using Heavy Rare-Earth Free La(Fe,Si) 13 -Based Compounds

The transition toward a carbon-neutral society based on renewable energies goes hand in hand with the availability of energy-efficient technologies. Here, magnetocaloric cooling is a very promising refrigeration technology to fulfill this role regarding cryogenic gas liquefaction. However, the current reliance on highly resource critical, heavy rare-earth-based compounds as magnetocaloric material makes global usage unsustainable. Here, we aim to mitigate this limitation through the utilization of a multicaloric cooling concept, which uses the external stimuli of isotropic pressure and magnetic field to tailor and induce magnetostructural phase transitions associated with large caloric effects. In this study, La 0.7 Ce 0.3 Fe 11.6 Si 1.4 is used as a nontoxic, low-cost, low-criticality multiferroic material to explore the potential, challenges, and peculiarities of multicaloric cryocooling, achieving maximum isothermal entropy changes up to −28 J (kg K) −1 in the temperature range from 190 K down to 30 K. Thus, the multicaloric cooling approach offers an additional degree of freedom to tailor the phase transition properties and may lead to energy-efficient and environmentally friendly gas liquefaction based on designed-for-purpose, noncritical multiferroic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recent progress in the design of the K-DEMO divertor

The preliminary conceptual design of the Korean fusion demonstration reactor (K-DEMO) with a major radius of 6.8 m and the fusion power of 2200 MW has been studied since 2012. The overall configuration of the K-DEMO divetor system based on the ITER-like water-cooled tungsten technology is a double-null type symmetric divertor subdivided into 32 toroidal modules for the vertical maintenance. A detached divertor scenario with impurity seeding was considered as the primary approach for the power exhaust to reduce the peak heat flux lower than the engineering limit of 10 MW/m 2 . The power exhaust performance at the scrap off layer was estimated by using UEDGE-2D code, a two-dimensional fluid transport code for collisional edge plasma and neutral species like N, Ne, and Ar. Particle and heat flux on inboard and outboard divertor targets were calculated for the detached cased depending on parameters such as the impurity seeding rate, pumping rate, and the pedestal density. On the other hand, a magnetic solution like X-divertor, snowflake divertor, and super X-divertor to expand the plasma wet area was considered for K-DEMO since the detached divertor increasing a radiation fraction by impurity seeding might be able to be unstable. However, the extremely high current of poloidal coils was required more than the engineering limit, 20 MA, to form magnetic field lines for the alternative divertors. Based on the physical calculation of the edge plasma, engineering analyses were carried out to find out the thermal and structural reliability. The thermo-hydraulic analysis confirmed thermal stability, whether all comprising materials are operating within their allowable temperature windows when the case of the peak heat flux is set to 10 MW/m 2 on the outboard divertor target. The response surface optimization method derived two optimal design candidates employing two kinds of heat sink materials, respectively: the reduced activation ferritic martensitic (RAFM) steel and CuCrZr alloy. Additionally, the drawbacks and merits of the two materials were definite. The optimal design with applying RAFM steel was vulnerable to withstand thermal and mechanical loads since low thermal conductivity caused too thin thickness of the heat sink. On the other hand, the CuCrZr alloy has critical drawbacks in terms of activation and radioactive waste despite its high thermal conductivity. Meanwhile, preliminary electromagnetic (EM) analysis was carried out to estimate the EM loads caused by the abnormal behaviors of plasma since EM loads are one of the most critical external loads for designing a DEMO divertor.