Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controlled islanding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Model-based Cyber-attack Detection for Voltage Source Converters in Island Microgrids

With the upgrading of communication and control in microgrids, cyber threats on the power converters are increasing. Here, in this paper, a novel model-based cyber-attack detection methodology is proposed for each voltage source converter in microgrids. The Harmonics State Space Matrix (H-Matrix) is used to build the closed-loop transfer function, providing model-based estimation with the grid voltage and control reference. Then, the space phase model (SPM) is used to calculate residual to detect cyber-attacks in voltage source converter (VSC). As controller and converter parameters are included in the H-matrix, the proposed method also could detect cyber-attacks when voltage fluctuation occurs in the grid. To verify the feasibility of the proposed method, several attacks targeting VSC in an islanded microgrid are simulated in MATLAB. Simulation and detection results are introduced to demonstrate the resilience and feasibility of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through (FRT) capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop, and the instability if the VI is not adaptive. Simulation results of various unbalanced faults with high and low fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high and low fault impedances.

adaptive virtual impedance control↗

Unleashing the Frequency: Multi-Megawatt Demonstration of 100% Renewable Power Systems with Decentralized Communication-Less Control Scheme

Power systems, which range in size from small microgrids to island systems to large regional grids, are typically managed by a central controller that requires complex communication methods and can be unreliable and pose cyber security risks in certain applications, especially when controlling a larger number of nodes. We propose an inherently robust, scalable method of integration using multiple energy storage systems and distributed energy resources, which does not require any means of dedicated communication. This method moves beyond the paradigm of controlling grid frequency at a fixed value (e.g., 60 Hz), instead allowing the frequency to fluctuate within certain limits (e.g., 59.6-60.4 Hz). With a greater operating range, the frequency can carry necessary information from energy storage systems to highly variable distributed energy resources like photovoltaics, wind, hydro, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-time power management technique for microgrid with flexible boundaries

In order to diminish the impacts brought by high penetration of renewable energy on the reliability of distribution systems, some distribution networks (e.g. Chattanooga electric power board system) have deployed smart switches (SSs) to island some areas to mitigate outage losses. However, due to intermittency and sharply changing rate of renewable energy, it is likely to experience insufficient or excessive power for islanded areas. Therefore, a microgrid controller featured with flexible boundaries is proposed. With proposed microgrid controller, the microgrid can not only shrink or expand its boundaries according to current renewable energy supply, but also disconnect/connect to the main grid with a designated SS. Furthermore, to ensure the microgrid controller could obtain suitable boundaries on the time scale of seconds, a real-time power management technique with alternative generating algorithm is designed to generate all possible alternative boundaries and choose the optimal one, which is scalable to any topology. In addition, in order to maintain state of charge of batteries within a desirable range, anti-overcharge/discharge strategies are designed. Four comprehensive experiments verify that the implementation of the microgrid controllers can realise flexible boundaries and deal with sharply changing rate of renewable generation or load on the time scale of seconds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detect and Avoid and Collision Avoidance Flight Test Results with ACAS Xr

In October 2023, the National Aeronautics and Space Administration (NASA) completed its Integration of Automated Systems flight test series, conducted under NASA’s Advanced Air Mobility project and in partnership with Sikorsky and the Defense Advanced Research Projects Agency (DARPA). The flight test effort included two crewed rotorcraft platforms. The first, a modified S-76B helicopter, served as the “ownship” for the duration of the flight test. The second vehicle, a modified S-70, served as the intruder aircraft. One Sikorsky pilot and one NASA test pilot was onboard each aircraft for every test point, with the NASA test pilot responsible for interacting with the research systems under test. Approximately half of the flight test was devoted to assessing the Federal Aviation Administration’s (FAA) next-generation collision avoidance system, the Airborne Collision Avoidance System X for Rotorcraft (ACAS Xr). The two configurations available within ACAS Xr – the Collision Avoidance System (CAS) configuration and the Detect and Avoid (DAA) configuration – were flown with an onboard pilot under Visual Flight Rules in controlled airspace over the Long Island Sound (Connecticut, USA). A total of 33 flight test cards were flown with ACAS Xr active. The ownship was equipped with ACAS Xr and the intruder was equipped with Automatic Dependent Surveillance-Broadcast (ADS-B). The test points were blocked by ACAS Xr configuration, with individual encounters varying the ownship speed (90 knots or 20 knots), the intruder designation (en-route, terminal area, or structured airspace), and method of RA execution (automated or manually executed). Results showed that the ACAS Xr alerting and guidance was largely effective and rated positively by the NASA test pilots, exemplified by zero instances of the pilots overriding an ACAS Xr Resolution Advisory (RA). Key areas of improvement, however, were noted, particularly with regards to the lack of an aural alert indicating a need to accelerate when receiving an RA at low speed and the occurrence of multiple RAs that the pilots found to be unacceptable.

detect and avoid↗

Detect and Avoid and Collision Avoidance Flight Test Results with ACAS Xr

In October 2023, the National Aeronautics and Space Administration (NASA) completed its Integration of Automated Systems flight test series, conducted under NASA’s Advanced Air Mobility project and in partnership with Sikorsky and the Defense Advanced Research Projects Agency (DARPA). The flight test effort included two crewed rotorcraft platforms. The first, a modified S-76B helicopter, served as the “ownship” for the duration of the flight test. The second vehicle, a modified S-70, served as the intruder aircraft. One Sikorsky pilot and one NASA test pilot was onboard each aircraft for every test point, with the NASA test pilot responsible for interacting with the research systems under test. Approximately half of the flight test was devoted to assessing the Federal Aviation Administration’s (FAA) next-generation collision avoidance system, the Airborne Collision Avoidance System X for Rotorcraft (ACAS Xr). The two configurations available within ACAS Xr – the Collision Avoidance System (CAS) configuration and the Detect and Avoid (DAA) configuration – were flown with an onboard pilot under Visual Flight Rules in controlled airspace over the Long Island Sound (Connecticut, USA). A total of 33 flight test cards were flown with ACAS Xr active. The ownship was equipped with ACAS Xr and the intruder was equipped with Automatic Dependent Surveillance-Broadcast (ADS-B). The test points were blocked by ACAS Xr configuration, with individual encounters varying the ownship speed (90 knots or 20 knots), the intruder designation (en-route, terminal area, or structured airspace), and method of RA execution (automated or manually executed). Results showed that the ACAS Xr alerting and guidance was largely effective and rated positively by the NASA test pilots, exemplified by zero instances of the pilots overriding an ACAS Xr Resolution Advisory (RA). Key areas of improvement, however, were noted, particularly with regards to the lack of an aural alert indicating a need to accelerate when receiving an RA at low speed and the occurrence of multiple RAs that the pilots found to be unacceptable.

detect and avoid↗

Flight-Test Evaluation of the Longitudinal Stability and Control Characteristics of 0.5-Scale Models of the Fairchild Lark Pilotless-Aircraft Configuration. Model with Wing Flaps Deflected 15 Degrees, TED No. NACA 2387

A flight test was conducted at the Flight Test Station of the Pilotless Aircraft Research Division at Wallops Island, Va., to determine the longitudinal control and stability characteristics of a 0.5-scale model of the Fairchild Lerk Pilotless aircraft with the horizontal wing flaps deflected 15 degrees. The data were obtained by the use of a telemeter and also by radar tracking. The results show an increase of effectiveness of the longitudinal control in producing normal accelerations up to a Mach number of 0.75 where this effectiveness gradually decreased becoming negative at a Mach number of 0.89. Previous tests with wing flaps undeflected an increase in effectiveness up to Mach number of 0.93 where a sudden loss of control occurred. The model was dynamically stable throughout the speed range. The data confirmed the drag increase at the critical Mach number for large angles of attack is indicated in high-speed wind-tunnel tests.

Stone, David G.↗

Dynamic Modeling of Sequential Service Restoration in Islanded Single Master Microgrids

This paper presents a methodology for generating restoration sequences in distribution systems and microgrids with emphasis on deriving optimal switching times for remote control switches (RCS). Microgrid architecture considered are assumed to be operating in islanded single master mode. Control methods for handling the unbalance inherent in distribution systems using single-phase controlled PQ inverters were developed and incorporated in the proposed method. The problem of considering simultaneously both energy optimization and dynamic stability of the system, which is lacking in existing methods, was addressed by studying the transient behavior of microgrids based on extended EMTP simulations and then approximate and incorporate these behaviors into the optimization formulation for restoration. The approach is based on multi-objective optimization of final restored load and total restoration time. The methodology was studied on a modified IEEE 123 node test feeder. An EMTP simulation in PSCAD of the formed microgrids was used to validate the accuracy of the dynamic and steady-state characteristics of the resulting systems. By considering the transient behavior of DGs during restoration, a better restoration sequence that does not trigger protection relays could be realized.

42 ENGINEERING↗

Controller Requirements for Managing Community Microgrids

Microgrid control systems are central to the functioning of a microgrid. They are responsible for managing distributed energy resources (DER) in both grid-connected and islanded modes of operation. Although microgrids are being developed and deployed by many utilities, several questions are being raised about the control system that manages them. This document provides the detailed list of requirements for a feeder-level microgrid controller to manage various islanded and grid-connected use cases. Functionally, the use cases include control scenarios that require the controller to maintain energy balance, prevent constraint violations, manage switching equipment, manage grid-forming (GFM) and grid-following (GFL) DER, manage critical/non-critical loads, and coordinate with peer systems to operate joined island areas. In addition to detailed requirements, the document includes interface and performance metrics for functional evaluation. These requirements can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; requirements also apply to third-party managed microgrid controllers that coordinate with the utility- and customer-owned equipment. The document can also be used by technology developers and project developers in industry to specify desired control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inverter Controls for Smooth Transition Operation of Networked Microgrids

Islanding sections of a distribution grid as microgrids and networking these microgrids offer promising opportunities for improving system reliability; however, this approach may need distributed energy resources (DERs) to switch between grid-connected and islanded operation without affecting the system stability. The Thevenin impedance of the power system at the DER point of common coupling changes due to networking actions. It is critical to have smooth transitions between modes to ensure stable system operation and to avoid nuisance tripping. This paper presents the design of a grid-forming (GFM)-capable inverter control scheme to reliably operate in distribution systems with networked microgrids. Control mechanisms for smooth transitions between grid-following (GFL) and GFM inverter modes are presented. First, we test the control mechanism on a simple two-source power system through electromagnetic transient (EMT) simulations using a digital real-time simulator. Then, we add multiple such DERs to the EMT model of a real-world distribution feeder and demonstrate stable operation between mode transitions during the networking of the microgrids.

grid forming controls↗

Flight-Test Evaluation of the Longitudinal Stability and Control Characteristics of 0.5-Scale Models of the Fairchild Lark Pilotless-Aircraft Configuration: Standard Configuration with Wing Flaps Deflected 60 Degrees and Model having Tail in Line with Wings, TED No. NACA 2387

Flight tests were conducted at the Flight Test Station of the Pilotless Aircraft Research Division at Wallop Island, Va., to determine the longitudinal control and stability characteristics of 0.5-scale models of the Fairchild Lark pilotless aircraft with the tail in line with the wings a d with the horizontal wing flaps deflected 60 deg. The data were obtained by the use of a telemeter and by radar tracking.

Stone, David G.↗

Small Hydro Power Plants with Integrated BESS for Enhance Resiliency

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a black start- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFM controlled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of Power System Black Start with Hydropower Generator and Battery Energy Storage: Preprint

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a blackstart- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFMcontrolled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MiGRIDS

MiGRIDS is a software that models islanded microgrid power systems with different controls and components. For example, using load and resource data from a microgrid, you could model it with additional wind turbines, battery etc. You could also try out different dispatch schemes to see which one worked best. MiGRIDS is designed to help optimize the size and dispatch of grid components in a microgrid. While a grid connect feature is expected to be added in the future, islanded operation is the focus. Note that this is a basic implementation and more features and functionality (such as a GUI) are coming! MiGRIDS runs time-step energy balance simulations for different grid components and controls. In smaller microgrid environments, dispatch decisions are being made on the order of seconds. In order to fully capture their effect, this tool lets you run simulations on the order of seconds. The end result is a more realistic representation of what can be achieved by integrating different components and control strategies in a grid.

Morgan, Tawna↗

Design of a Non-PLL Grid-Forming Inverter for Smooth Microgrid Transition Operation

This paper develops a controller for a grid-forming (GFM) inverter that is capable of operating as either a GFM or grid-feeding source that can improve the operation of a microgrid during on-off grid transitions through use of a novel synchronization approach. Furthermore, this controller avoids use of a phase-locked loop (PLL) and the inverter is able to synchronize with the grid with self-generated voltage and frequency. This prevents the inverter from replicating any grid voltage disturbances in its output—a key disadvantage of many grid-connected inverters that use a PLL. To enable fast synchronization, active synchronization control is adopted both during inverter start-up and microgrid reconnection operation and a method of coordinating synchronization of the inverter with a microgrid controller and grid interconnection circuit breaker is presented. Simulation results for multiple microgrid transition operations and unplanned islanding events demonstrate that the developed non-PLL grid-connected GFM inverter controller and synchronization method are effective in synchronizing the inverter and microgrid to the grid, avoiding phase jump during microgrid transition operation, and improving microgrid islanding transients versus a traditional configuration.

27 ARPA - Advanced Research Projects Agency-Energy↗

Enhancement of ECCD by the current condensation effect for stabilizing large magnetic islands caused by neoclassical tearing modes in tokamak plasmas

The radio frequency current condensation effect reported in Reiman and Fisch (2018 Phys. Rev. Lett. 121 225001) is modeled in the nonlinear resistive magnetohydrodynamic code. A series of numerical investigations have been performed to investigate the enhancement of electron cyclotron current drive (ECCD) by the current condensation effect during the control of neoclassical tearing mode (NTM) in tokamak plasmas. In the numerical model, both the parallel transport and the perpendicular transport of electron temperature are considered. The EC driven current and driven perturbed electron temperature can nonlinearly evolve within the given magnetic configuration and eventually reach saturation states. The input power threshold of ECCD and the fold bifurcation phenomenon are numerically verified via nonlinear simulations. The numerical results show good agreements with the analytical results. Moreover, spatial distributions of EC current for the two solutions at different condensed level are displayed. The control effectiveness of ECCD for large NTM islands has been evaluated while considering the current condensation effect. While taking into account current condensation effect, for a sufficiently large input power, a larger island can be more effectively stabilized than a smaller one, which suggests a reassessment of the previous idea that the ECCD should always be turned on as early as possible. The potential physics mechanism behind the ECCD control have all been discussed in detail. Furthermore, the condensation effect is found to have favorable effects on the radial misalignment of ECCD. In the consideration of the situation for extremely localized control needs, a highly peaked heating profile is adopted to verify that the fold bifurcation phenomenon still exists and the current condensation effect can still take effect in this extreme condition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Response of selected plant and insect species to simulated solid rocket exhaust mixtures and to exhaust components from solid rocket fuels

The effects of solid rocket fuel (SRF) exhaust on selected plant and and insect species in the Merritt Island, Florida area was investigated in order to determine if the exhaust clouds generated by shuttle launches would adversely affect the native, plants of the Merritt Island Wildlife Refuge, the citrus production, or the beekeeping industry of the island. Conditions were simulated in greenhouse exposure chambers and field chambers constructed to model the ideal continuous stirred tank reactor. A plant exposure system was developed for dispensing and monitoring the two major chemicals in SRF exhaust, HCl and Al203, and for dispensing and monitoring SRF exhaust (controlled fuel burns). Plants native to Merritt Island, Florida were grown and used as test species. Dose-response relationships were determined for short term exposure of selected plant species to HCl, Al203, and mixtures of the two to SRF exhaust.

Heck, W. W.↗

Probabilistic locked mode predictor in the presence of a resistive wall and finite island saturation in tokamaks

We present a framework for estimating the probability of locking to an error field in a rotating tokamak plasma. This leverages machine learning methods trained on data from a mode-locking model, including an error field, resistive magnetohydrodynamics modeling of the plasma, a resistive wall, and an external vacuum region, leading to a fifth-order ordinary differential equation (ODE) system. It is an extension of the model without a resistive wall introduced by Akçay et al. [Phys. Plasmas 28, 082106 (2021)]. Tearing mode saturation by a finite island width is also modeled. We vary three pairs of control parameters in our studies: the momentum source plus either the error field, the tearing stability index, or the island saturation term. The order parameters are the time-asymptotic values of the five ODE variables. Normalization of them reduces the system to 2D and facilitates the classification into locked (L) or unlocked (U) states, as illustrated by Akçay et al., [Phys. Plasmas 28, 082106 (2021)]. This classification splits the control space into three regions: L̂, with only L states; Û, with only U states; and a hysteresis (hysteretic) region Ĥ, with both L and U states. In regions L̂ and Û, the cubic equation of torque balance yields one real root. Region Ĥ has three roots, allowing bifurcations between the L and U states. The classification of the ODE solutions into L/U is used to estimate the locking probability, conditional on the pair of the control parameters, using a neural network. We also explore estimating the locking probability for a sparse dataset, using a transfer learning method based on a dense model dataset.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗