Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controlled humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Engineering Scale Drying of Aluminum-Clad Spent Nuclear Fuel: Experiment Report

Engineering-scale tests were performed to evaluate the relative effectiveness of forced gas and vacuum-drying processes on aluminum-clad spent nuclear fuel (ASNF) in preparation for extended dry storage. Drying models were developed to improve confidence in the likely range of conditions at the start of dry storage and to understand the factors most significant to each process. Testing was performed at the Holtec International Forced Helium Dehydration training facility in Camden, New Jersey, by students from the University of South Carolina in collaboration with Idaho National Laboratory. A full-size Type 1a basket, with a full-diameter vessel configuration (based on the Department of Energy standardized canister design), was used in combination with a 10 assembly surrogate ASNF arrangement to provide a proxy for geometry. A resistance heater incorporated in one assembly simulated the influence of 100 W decay heat. This instrumented chamber allowed testing of the removal of bulk water, physisorbed water, and chemisorbed water over a range of operating parameters with either drying process. Thick oxide films were grown on aluminum test plates to mimic the ASNF surface chemistry. These one-use test plates were housed within select assemblies during drying. Post-test analysis of these plates gave a measure of the moisture removed during each test, which was compared to a control. Instrumentation provided detailed thermal, humidity, and gas or pressure data relevant to each test. Model simulations generally compared favorably to instrument data for the tests. While both processes were able to remove bulk water, removal of chemisorbed water was shown to depend heavily on local temperature. To the disadvantage of vacuum drying, operations approaching or exceeding 220°C achieved consistently more dehydroxylation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scalable and Quench-Free Processing of Metal Halide Perovskites in Ambient Conditions

With the rise of global warming and the growing energy crisis, scientists have pivoted from typical resources to look for new materials and technologies. Perovskite materials hold the potential for making high-efficiency, low-cost solar cells through solution processing of Earth-abundant materials; however, scalability, stability, and durability remain key challenges. In order to transition from small-scale processing in inert environments to higher throughput processing in ambient conditions, the fundamentals of perovskite crystallization must be understood. Classical nucleation theory, the LaMer relation, and nonclassical crystallization considerations are discussed to provide a mechanism by which a gellan gum (GG) additive—a nontoxic polymeric saccharide—has enabled researchers to produce quality halide perovskite thin-film blade coated in ambient conditions without a quench step. Furthermore, we report on the improved stability and durability properties inherent to these films, which feature improved morphologies and optoelectronic properties compared to films spin-coated in a glovebox with antisolvent. We tune the amount of GG in the perovskite precursor and study the interplay between GG concentration and processability, morphological control, and increased stability under humidity, heat, and mechanical testing. The simplicity of this approach and insensitivity to environmental conditions enable a wide process window for the production of low-defect, mechanically robust, and operationally stable perovskites with fracture energies among the highest obtained for perovskites.

14 SOLAR ENERGY↗

Identifying Controlling Variables for Mercury Vapors in Alpha-4 at Y-12: Two Year Data Collection Update

Multiple sensor packages were deployed at Alpha-4 by SRNL, in collaboration with United Cleanup Oak Ridge LLC (UCOR), to monitor mercury vapor concentrations and meteorological parameters. These sensors collected data, inside and outside of the legacy-use facility, for approximately two years. Though data gaps still exist, particularly in colder months, several controlling variables were identified that govern mercury vapor concentrations within Alpha-4. Temperature, barometric pressure gradients, humidity, and wind speed have been identified as controlling variables. A strong positive correlation was seen between mercury vapor concentrations and temperature which generally followed diurnal fluctuations. Temperatures below approximately 10 degrees Celsius did not show any spikes above the PEL, indicating more work can be performed at any time during the winter months – more data should be collected to confirm consistency in this finding. Additionally, spikes in mercury vapor concentrations above that of the permissible exposure limit (PEL; 100 µg/m 3 ) occurred primarily in late afternoon or evening/overnight hours (between 3 PM and 6 AM), which suggests D&D operations might be best scheduled during morning or daytime hours prior to the late afternoon. However, a limited number of spikes did occur outside of the identified window, although this may be attributed to disturbances in air flow and mercury vapor release from work activities performed inside of the Alpha-4 building. The analysis conducted allows for a strong predictive capability for estimating mercury vapor concentrations based upon accurate meteorological parameters. Still, additional data collection, particularly in the winter months, could help to strengthen the predictive power and validate the identified data trends. Further, increased temporal resolution could also help to better characterize the incipient stages of the increases and decreases in the mercury vapor concentration. Continued monitoring support by SRNL at Y-12 is underway at Alpha-4 to further close remaining data gaps and support deactivation and decommissioning work. Within a collaborative effort with UCOR, the SRNL team is collecting mercury vapor data to study the efficacy of a novel mercury suppressant, FerroBlack® which was recently deployed at Alpha-4. In addition, modifications to the current monitoring setup to increase measurement resolution is also being investigated.

54 ENVIRONMENTAL SCIENCES↗

All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control

This is the final report for the project “All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control”, funded by DOE, and performed by Clemson University, Phase IV Engineering and Harvard University from October 1, 2016 to December 31, 2020. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, plug & play, battery-free, wireless sensor technology to enable low-cost (<$10 per node) indoor and outdoor temperature and humidity measurement for energy efficient building controls and operations. The proposed technology is based on the novel concept of all-digital sensing and its seamless integration with the passive RFID technology. This project focuses on the design, fabrication, material optimization, interrogation electronics, validation, and demonstration of the novel sensor nodes for building applications. The specific objectives of this research program include: (1) Design, fabricate and optimize a compact, robust, and high-resolution digitizer, which could convert rotation angle into digital numbers. (2) Develop the multi-physics-based modeling and simulation of the temperature/humidity transducer to derive a rational design of the architecture, dimension, structure, materials (i.e., mechanical, electrical, thermal and hygroscopic) properties and functions of the sensor node. (3) Design, fabricate and optimize the bi-material based humidity sensitive coil which could linearly transduce the environmental relative humidity variations to rotation angles. (4) Design, fabricate and optimize an UHF RFID platform which could support long-range passive wireless communications of 8-bit digital numbers. (5) Design, fabricate and optimize the miniaturized all-digital sensor using MEMS technology. (6) Validate the integrated all-digital sensing system in a real building environment to test the system’s performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aqueous spray-drying synthesis of alluaudite Na 2+2x Fe 2–x (SO 4 ) 3 sodium insertion material: studies of electrochemical activity, thermodynamic stability, and humidity-induced phase transition

In pursuit of high-energy density sodium insertion materials, polyanionic frameworks can be designed with tuneable high-voltage operation stemming from inductive effect. Alluaudite Na 2 Fe 2 (SO 4 ) 3 polysulfate forms one such earth-abundant compound registering the highest Fe 3+ /Fe 2+ redox potential (ca. 3.8 V vs. Na/Na + ). While this SO 4 -based system exhibits high voltage operation, it is prone to thermal decomposition and moisture attack leading to hydrated derivatives, making its synthesis cumbersome. Also, the Na–Fe–S–O quaternary system is rich with (anhydrous to hydrated) phase transitions. Herein, we demonstrate scalable aqueous-based spray drying synthesis of alluaudite Na 2+2x Fe 2–x (SO 4 ) 3 sodium insertion material involving the formation of bloedite Na 2 Fe(SO 4 ) 2 ·4H 2 O as an intermediate phase. Moreover, a reversible phase transition from alluaudite to bloedite under controlled conditions of temperature and relative humidity is reported for the first time. Thermochemistry measurements revealed the enthalpies of formation (ΔH° f ) of alluaudite and bloedite are exothermic. Hydrated bloedite (ΔH° f = –117.16 ± 1.10 kJ/mol) was found to be significantly more energetically stable than anhydrous alluaudite (ΔH° f = –11.76 ± 1.25 kJ/mol). The calorimetric data support the observed synthesis and transformation (hydration-dehydration) pathways. Spray drying route led to spherical morphology delivering capacity ~80 mAh/g. Spray drying can be extended for rapid economic synthesis of sulfate class of battery materials.

25 ENERGY STORAGE↗

Changing temperature profiles and the risk of dengue outbreaks

As temperatures change worldwide, the pattern and competency of disease vectors will change, altering the global distribution of both the burden of infectious disease and the risk of the emergence of those diseases into new regions. To evaluate the risk of potential summer dengue outbreaks triggered by infected travelers under various climate scenarios, we develop an SEIR-type model, run numerical simulations, and conduct sensitivity analyses under a range of temperature profiles. Our model extends existing theoretical frameworks for studying dengue dynamics by introducing temperature dependence of two key parameters: the mosquito extrinsic incubation period and the lifespan of mosquitoes, which empirical data suggests are both highly temperature dependent. We find that changing temperature significantly alters dengue risk in an inverted U-shape, with temperatures in the range 27-31°C producing the highest risk. As temperatures increase beyond 31°C, the determinants of dengue risk begin to shift from mosquito biting rate and carrying capacity to the duration of the human infectious period, suggesting that changing temperatures not only alter dengue risk but also the potential efficacy of control measures. To illustrate the role of spatial and temporal temperature heterogeneity, we select five US cities where the primary dengue vector, the mosquito Aedes aegypti , has been observed, and which have had dengue cases in the past: Los Angeles, Houston, Miami, Brownsville, and Phoenix. Our analysis suggests that an increase of 3°C leads to an approximate doubling of the risk of dengue in Los Angeles and Houston, but a reduction of risk in Miami, Brownsville, and Phoenix due to extreme heat.

54 ENVIRONMENTAL SCIENCES↗

Unified Entrainment and Detrainment Closures for Extended Eddy-Diffusivity Mass-Flux Schemes

The extended Eddy Diffusivity Mass Flux (EDMF) scheme is used as a unied parameterization that simulates subgrid-scale dynamics across a range of regimes.This work presents unied entrainment and detrainment closures that allow this scheme to simulate the dry convective boundary layer, shallow convection and deep convection , while adjacent works present other necessary closures for this unied scheme and test its performance for stable, stratocumulus topped and convective boundary layers. Entrainment and detrainment are modeled as a combination of turbulent and dynamical processes. The turbulent component is taken as downgradient diffusion between subdomains. The dynamical component is based on a ratio of buoyancy and vertical velocity that ensures consistent treatment of the ratio of mass-flux at vanishing area fraction. Dynamical detrainment is controlled by the difference in relative humidity between subdomains when liquid water is present. These closures are rst evaluated with entrainment and detrainment diagnosed from Large Eddy Simulations where decaying tracers are used to identify the different subdomains and mass exchanges between them. When implemented in a single column model (SCM), these closures are tested in simulations of several observationally motivated cases of dry convective boundary layer, shallow convection and deep convection. Results show good agreement between the SCM and Large Eddy Simulations in key properties for climate models and profiles of first, second and third moments. The development of diurnal cycles and the onset of and precipitation (with simplified microphysics) are well predicted by the SCM.

54 ENVIRONMENTAL SCIENCES↗

Stomata in-sight: Integrating live confocal microscopy with leaf gas exchange and environmental control

Stomatal anatomy (aperture area, length, and width) influences leaf-level physiology traits including conductance to water vapor. Stomatal anatomy can be visualized in situ by microscopy, but the difficulty of regulating the atmospheric environment of a microscope stage means that the conditions under which imaging is done are rarely physiologically relevant. Alternatively, leaf gas exchange instruments that measure gas fluxes reflect stomatal anatomical characteristics in aggregate, but the relative strengths of anatomical traits to control water use (e.g. size vs density) cannot be firmly established. To reconcile the microscopic stomatal characteristics with leaf-level gas exchange, we describe a tool that combines laser scanning confocal microscopy, gas exchange instruments, and machine-learning image analysis to simultaneously observe anatomical characteristics of many (>40) stomata alongside leaf-level traits like photosynthesis, transpiration, and stomatal conductance. We demonstrate how the tool has the resolution capable of quantifying aperture sizes and variability in maize (Zea mays) leaves under 5 steady-state light/pCO 2 treatments while tightly controlling other environmental variables like relative humidity and temperature. A model used to calculate stomatal conductance from measured apertures and stomatal density accurately matched stomatal conductance measured by gas exchange. This technical advancement will provide insight on how stomatal anatomy and function trade off to influence stomatal conductance and leaf-level water use efficiency.

59 BASIC BIOLOGICAL SCIENCES↗

Mid Infra-Red Laser Sensor for Continuous Sulfur Trioxide Monitoring to Improve Coal-Fired Power Plant Performance during Flexible Operations

During the course of this project, we performed exhaustive research and development of SO3/H2SO4 sensing technology for coal-fired power plant applications (Figure 1). The development culminated in a successful field campaign of a prototype continuous real-time H2SO4 monitor at a coal-fired power plant (TRL 6) accomplishing the primary goal of the project. The developed sensors utilize tunable laser absorption spectroscopy (TLAS) operating in the mid-infrared (Mid-IR) wavelength region, which is the so-called “molecular fingerprint” region. Systems operating in the Mid-IR have orders of magnitude more sensitivity than systems operating at shorter wavelengths, such as near-infrared (NIR). However, NIR systems are more widespread due to more mature supporting technology (e.g., fiber optics, optical components, etc.). In this project, we not only produced a specific Mid-IR sensor, we also advanced Mid-IR sensor technology in general through the development and demonstration of such supporting technology. In this project, we also developed proprietary broad tuning lasers enabling the ability to effectively measure SO3, H2SO4, H2O, and SO2. Different molecular species have unique spectral signatures that can be probed with lasers operating at different wavelengths. Standard TLAS uses relatively narrow wavelength tuning distributed feedback (DFB) lasers, which can typically only target a single species with narrow features, and are not appropriate for species with broad features, such as SO3 or H2SO4. In contrast, by developing unique, broad-tuning laser technology, we were able to measure these species, as well as SO2 and H2O simultaneously. Furthermore, to enable real-time analysis at a power plant, we modified a commercially available heated gas cell to operate in the Mid-IR wavelength range and fiber coupled the lasers to enable remote delivery of the beams. To generate reference data (library spectra), our collaborators at the University of California Irvine (UCI) developed a catalytic SO3 generation facility. It is worth mentioning that representative H2SO4 and SO3 Mid-IR spectra are not a part of any publicly available database and the data generated under this project is a valuable resource in and of itself. In addition, based on the UCI study we determined that detection of SO3 is complicated by the very strong SO2 absorption. For that reason, we concentrated on H2SO4 detection. Since SO3 and H2SO4 exist in a flue gas in a state of equilibrium, which depends on temperature and humidity, by measuring water concentration and controlling the temperature of the gas cell, we developed an approach to determine SO3 concentration from the H2SO4 measurement. During the development phase of the project, we performed three testing campaigns at our collaborator’s FERCo flue gas facility with conditions representative of the coal-fired power plant (~ 40ppm SO3, 1700ppm to 2800 ppm SO2, 10% water) with the exception of particulate matter. After three test campaigns at FERCo we performed field testing at Harrison Power Station. The final system was mounted on a duct and measured H2SO4, SO2 and water. The tests were highly successful with a demonstrated real-time H2SO4 precision of 1 ppm with a 1 second update. Our collaborators at EPRI conducted an industry survey and determined that there is a very high interest for the SO3/H2SO4 monitoring in the power generation industry as well as in heavy industries in general. Furthermore, work performed by OptoKnowledge beyond the scope of this project under a synergistic DOE SBIR determined another approach to SO3 detection. We applied for Phase II on this SBIR for development a of versatile SO3/H2SO4 sensor but were not selected. We are currently looking for another opportunity to leverage all the technological advancements produced by this project including but not limited to the flue gas facility at UCI, the hardware and software developed, and relationships with FERCo, EPRI CEMTEK, and Harrison Station.

01 COAL, LIGNITE, AND PEAT↗

Evolution of water structures in metal-organic frameworks for improved atmospheric water harvesting

Designing water uptake Although the locations of water molecules in some porous materials have been determined with diffraction techniques, determining the filling sequence of water sites has been challenging. Hanikel et al . used single-crystal x-ray diffraction to locate all of the water molecules in pores of the metal-organic framework MOF-303 at different water loadings (see the Perspective by Öhrström and Amombo Noa). They used this information on the water molecule adsorption sequence to modify the linkers of this MOF and control the water-harvesting properties from humid air for different temperature regimes. —PDS

Science & Technology - Other Topics↗

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pit growth kinetics in aluminum: effects of salt loading and relative humidity

Abstract The growth kinetics of localized corrosion, e.g. pits, in corrosive environments often controls the service life of metallic components. Yet, our understanding of these kinetics is largely based on coupon-level, e.g. mass-loss, studies which provide limited insights into the evolution of individual damage events. It is critical to relate observed cumulative loss trends, such as links between changing humidity and mass loss rates, to the growth kinetics of individual pits. Towards this goal, we leverage in-situ X-ray computed tomography to measure the growth rates of over sixty pits in aluminum in four different humid, chloride environments over ≈3 days of exposure. Pit growth rates and final volumes increased with increasing droplet volume, which was observed to increase with increasing humidity and salt loading. Two factors, droplet spreading and oxide jacking, dramatically increased pit growth rates and final volumes.

Noell, Philip J. (ORCID:0000000346998999)↗

Disentangling Oxygen and Water Vapor Effects on Optoelectronic Properties of Monolayer Tungsten Disulfide

By understanding how the environmental composition impacts the optoelectronic properties of transition metal dichalcogenide monolayers, we demonstrate that simple photoluminescence (PL) measurements of tungsten disulfide (WS 2 ) monolayers can differentiate relative humidity environments. In this paper, we examine the PL and photoconductivity of chemical vapor deposition grown WS 2 monolayers under three carefully controlled environments: inert gas (N 2 ), dry air (O 2 in N 2 ), and humid nitrogen (H 2 O vapor in N 2 ). The WS 2 PL is measured as a function of 532 nm laser power and exposure time and can be decomposed into the exciton, trion, and lower energy state(s) contributions. Under continuous illumination in either O 2 or H 2 O vapor environment, we find dramatic (and reversible) increases in PL intensity relative to the PL in an inert environment. The PL bathochromically shifts in an O 2 environment and is dominated by increased trion emission and diminished exciton emission. In contrast, the WS 2 PL increase in a H 2 O environment results from an overall increase in emission from all spectral components where the exciton contribution dominates. The drastic increases in PL are anticorrelated with corresponding decreases in photoconductivity, as measured by time-resolved microwave conductivity. The results suggest that both O 2 and H 2 O react photochemically with the WS 2 monolayer surface, modifying the optoelectronic properties, but do so via distinct pathways. Thus, we use these optoelectronic differences to differentiate the amount of humidity in the air, which we show with 0%, 40%, and 80% relative humidity environments. This deeper understanding of how ambient conditions impact WS 2 monolayers enables novel humidity sensors as well as a better understanding of the correlation between TMDC surface chemistry, light emission, and photoconductivity. Moreover, these WS 2 measurements highlight the importance of considering the impact of the local environment on reported results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flash Freeze Flow Tube to Vitrify Aerosol Particles at Fixed Relative Humidity Values

Development of methods to measure the phase transitions and physical properties of submicron atmospheric aerosol particles is needed to better model these systems. Here, we introduce a method to flash freeze submicron particles to measure phase transitions as a function of relative humidity (RH). Particles are equilibrated at a fixed RH, vitrified in a temperature-controlled flow tube, and imaged with cryogenic transmission electron microscopy (cryo-TEM). We demonstrate the use of the technique for measuring the efflorescence relative humidity (ERH) of potassium sulfate and potassium chloride aerosol as well as the separation RH for a multicomponent organic/inorganic system that undergoes liquid-liquid phase separation (LLPS). The location of phase transitions can shift between the micrometer and nanometer size regimes and particles in a given population may have a range of RH over which a phase transition occurs. This technique addresses these requirements by allowing for characterization of the phase transitions for individual particles in a population on the submicron scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental measurements of fuel and water crossover in an active DMFC

This work measured polarization curves as well as the high-frequency resistance of active direct methanol fuel cell (DMFC) operates at around 80 °C with active controls of temperature, methanol concentration, airflow rate, and relative humidity. The relative humidity of the air did not have noticeable impacts on the fuel cell unless the operating temperature was near the evaporation temperature of water (100 °C). The hydrophobic water management layer (WML) between the membrane electrode assembly (MEA) and cathode air channel increases the mass transfer resistance and improves the water retention in MEA. Adding a WML increased the peak power density, decreased the ohmic resistance, and improved the fuel efficiency of the fuel cell, especially when it operated near 100 °C. This study also quantitatively measured methanol and water crossover as well as the fuel efficiency at different operating currents. The fuel efficiency increased significantly with the increase of the current density. Using a hydrophobic fuel management layer (FML) between the anode fuel channel and MEA reduced the fuel and water crossover rates and increased the ohmic resistance due to the decrease of the water content of the Nafion membrane. The FML improved fuel efficiency by reducing the methanol crossover. The combination of the FML and WML enabled the steady operation of DMFC using highly concentrated methanol solutions (up to 75 wt%).

08 HYDROGEN↗

Aerosol iron speciation and seasonal variation of iron oxidation state over the western Antarctic Peninsula

The iron (Fe) speciation and oxidation state have been considered critical factors affecting Fe solubility in the atmosphere and bioavailability in the surface ocean. In this study, elemental composition and Fe speciation in aerosol samples collected at the Palmer Station in the West Antarctic Peninsula were determined using synchrotron-based X-ray fluorescence (XRF) and X-ray Absorption Near-Edge Structure (XANES) spectroscopy. The elemental composition of coarse-mode (>1 mu m) Fe-containing particles suggests that the region's crustal emission is the primary source of aerosol Fe. The Fe minerals in these aerosol particles were predominantly hematite and biotite, but minor fractions of pyrite and ilmenite were observed as well. The Fe oxidation state showed an evident seasonal variation. Further, the Fe(II) content accounted for 71% of the total Fe in the austral summer, while this fraction dropped to 60% in the austral winter. Multivariate linear models involving meteorological parameters suggested that the wind speed, relative humidity, and solar irradiance were the factors that significantly controlled the percentage of Fe(II) in the austral summer. On the contrary, no relationship was found between these factors and the Fe(II) percentage in the austral winter, suggesting that atmospheric photoreduction and regional dust emission were limited. Moreover, the snow depth was significantly (p < 0.05) correlated with the aerosol Fe concentration, confirming the limiting effect of snow/ice cover on the regional dust emission. Given that the Antarctic Peninsula has experienced rapid warming during recent decades, the ice-free areas in the Antarctic Peninsula may act as potential dust sources.

54 ENVIRONMENTAL SCIENCES↗