At least 109 records · Page 6

West Valley Demonstration Project (WVDP) Annual Site Environmental Report (ASER) for Calendar Year 2024

The report, prepared for the U.S. Department of Energy West Valley Demonstration Project office (DOE-WVDP), summarizes the environmental protection program at the WVDP for calendar year (CY) 2024. Monitoring and surveillance of the facilities used by the DOE are conducted to verify protection of public health and safety and the environment. The report is a key component of DOE’s effort to keep the public informed of environmental conditions at the WVDP. The quality assurance protocols applied to the environmental monitoring program ensure the validity and accuracy of the monitoring data. In addition to demonstrating compliance with environmental laws, regulations, and directives, evaluation of data collected in 2024 continued to indicate that WVDP activities pose no threat to public health or safety, or to the environment.

54 ENVIRONMENTAL SCIENCES↗

Distinguishing photo-induced oxygen attack on alkyl chain versus conjugated backbone for alkylthienyl-benzodithiophene (BDTT)-based push–pull polymers

Synthetic design has enabled increasing power conversion efficiency advances in organic photovoltaics (OPV). One continuing knowledge gap is detailed understanding of single-material chemical (photo)stability. Many considerations are based on prior OPV-relevant donor homopolymer systems rather than the next-generation push–pull architectures. Generally, energetic offsets between the lowest occupied molecular orbital of the donor and molecular oxygen are assumed to dictate kinetics of photo-induced charge transfer to a super oxide radical. Herein we determine the ambient-induced photo-degradation pathways, presented as proposed site-specific arrow-pushing mechanisms, for five donor polymers all containing the same push unit – alkylthienyl-substituted-benzodithiophene (BDTT) – but with chemically distinct pull units. The donor-only polymer films were subject to controlled photobleaching in air as an accelerated degradation approach, coupled with simultaneous monitoring of absorptance. Sample subsets were periodically removed and analyzed with X-ray photoelectron spectroscopy, to evaluate near-surface chemical composition and oxygen additions to hetero reporter atoms on either the BDTT push unit or distinct pull unit (i.e., sulphur and nitrogen). Here, this methodology allows us to distinguish between different mechanisms of bond cleavage and formation. Overall, we find that neither polymer redox properties nor individual push or pull unit stability are sufficient to predict photo-oxidative degradation of these polymers. Rather, there is a greater dependence on the susceptibility of unique structural groups within a polymeric system. Alkyl chain oxygen addition is generally the first attack site and direct sulfur oxidation on the conjugated backbone occurs after saturation of the alkyl chain initiation sites. This work provides a standard that could be used to evaluate relative photo-oxidative (in)stability for new OPV materials quickly – prior to time-consuming device optimization – and demonstrates an effective methodology for correlating optical degradation with chemical structure alterations via spectroscopic signatures to guide synthetic design.

14 SOLAR ENERGY↗

Calcined Polyethyleneimine-Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Previous tests using metal oxide-based coatings (TiO2) provided strong responses at elevated temperatures and moderate pressure stability but provided poor differentiation between acidic and alkaline solutions. Building off the pH responsiveness of the TiO2 surface and known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. As the polymer itself is highly water soluble and easily removed by aqueous solutions, the sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1,000 psi) and temperatures (80 °C).

Shumski, Alexander↗

Long-term trends in urban NO 2 concentrations and associated paediatric asthma incidence: estimates from global datasets

Combustion-related nitrogen dioxide (NO 2 ) air pollution is associated with paediatric asthma incidence. We aimed to estimate global surface NO 2 concentrations consistent with the Global Burden of Disease study for 1990-2019 at a 1 km resolution, and the concentrations and attributable paediatric asthma incidence trends in 13 189 cities from 2000 to 2019. We scaled an existing annual average NO 2 concentration dataset for 2010-12 from a land use regression model (based on 5220 NO 2 monitors in 58 countries and land use variables) to other years using NO 2 column densities from satellite and reanalysis datasets. We applied these concentrations in an epidemiologically derived concentration-response function with population and baseline asthma rates to estimate NO 2 -attributable paediatric asthma incidence. We estimated that 1.85 million (95% uncertainty interval [UI] 0.93-2.80 million) new paediatric asthma cases were attributable to NO 2 globally in 2019, two thirds of which occurred in urban areas (1.22 million cases; 95% UI 0.60-1.8 million). The proportion of paediatric asthma incidence that is attributable to NO 2 in urban areas declined from 19.8% (1.22 million attributable cases of 6.14 million total cases) in 2000 to 16.0% (1.24 million attributable cases of 7.73 million total cases) in 2019. Urban attributable fractions dropped in high-income countries (-41%), Latin America and the Caribbean (-16%), central Europe, eastern Europe, and central Asia (-13%), and southeast Asia, east Asia, and Oceania (-6%), and rose in south Asia (+23%), sub-Saharan Africa (+11%), and north Africa and the Middle East (+5%). The contribution of NO 2 concentrations, paediatric population size, and asthma incidence rates to the change in NO 2 -attributable paediatric asthma incidence differed regionally. Despite improvements in some regions, combustion-related NO 2 pollution continues to be an important contributor to paediatric asthma incidence globally, particularly in cities. Mitigating air pollution should be a crucial element of public health strategies for children.

60 APPLIED LIFE SCIENCES↗

Use Attainability Analysis Aquatic Life Uses for Perennial Reach of Sandia Canyon [Slides]

The following information will be presented during the February 23, 2022 Accord Pueblos Technical Meeting. The purpose of the study is to determine if natural thermal conditions are preventing the attainment of Coldwater Aquatic Life Use in the perennial reach of the upper Sandia Canyon Assessment Unit (Sandia AU). The New Mexico Water Quality Standards allow for a change in the designated use if a Use Attainability Analysis (UAA) demonstrates that the use is not attainable due to one or more of six factors listed in 40 CFR 131.10(g), including naturally occurring pollutant concentrations. The Sandia AU is located in a perennial reach of upper Sandia Canyon between Sigma Canyon and NPDES Outfall 001. The classified Segment 20.6.4.126 NMAC comprises perennial waters within Los Alamos National Laboratory boundaries and includes the Sandia AU. Persistent surface flows originate from NPDES permitted effluent releases. These releases have occurred since the early 1950’s and continue today. The UAA examines several lines of evidence. NMED’s Air-Water Temperature Correlation (AWTC) model is used for identifying appropriate stream classifications and attainable aquatic life use subcategories. The model correlates between July average air temperatures (ATEMP) and maximum weekly average stream temperatures. Air temperatures are obtained from PRISM and LANL Meteorological Towers and used to derive ATEMP. Thermographs were placed in the Sandia AU to obtain measured stream temperatures during summer months when stream temperatures are the highest. Measured data is used with AWTC modeled data to determine if the Sandia AU is meeting its natural air temperature driven thermal condition.

54 ENVIRONMENTAL SCIENCES↗

Pacific Northwest National Laboratory Facility Radionuclide Emission Points and Sampling Systems

Battelle–Pacific Northwest Division operates numerous research and development laboratories in Washington State. The U.S. Department of Energy (DOE) contracts to Battelle at Richland facilities on both the DOE Hanford Site and the Pacific Northwest National Laboratory (PNNL) Richland campus. These facilities have the potential for radionuclide air emissions. The PNNL contract with DOE also includes operations at the PNNL-Sequim campus in Sequim, where there is also the potential for radionuclide air emissions. This document is a periodic update that describes current PNNL facility emission units and sampling systems. The National Emission Standard for Hazardous Air Pollutants (NESHAP [40 Code of Federal Regulations 61, Subpart H]) requires an assessment of all emission units that have the potential for radionuclide air emissions. Emission units are registered with the State of Washington. Potential emissions from emission units are assessed annually by PNNL staff. Sampling, monitoring, and other regulatory compliance requirements are designated based on the potential to-emit dose criteria, a graded approach to facility-identified potential impact categories, and regulatory requirements. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled emission units, the building, exhaust unit, control technologies, and sample extraction details are provided. Additionally, applicable configuration drawings, figures, and photographs are included. For non-sampled emission units, emission estimation and radionuclide source details are provided. Site-wide permits for the lowest potential impact category are described. Deregistered/transitioned emission unit details are also provided as necessary for at least 5 years post-closure/transition. Currently, five emission units are sampled continuously for particulate radionuclides at PNNL managed facilities on the PNNL-Richland campus (3 of the 5) and on the Hanford Site (2 of the 5). Four of these units have sampling systems that comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1–2011 standard for sampling from stacks and ducts of nuclear facilities, and the fifth is grandfathered and compliant with the older ANSI N13.1–1969 standard. In addition, the PNNL-managed Hanford Site 325 Building EP 325-01-S stack is sampled continuously for emissions of tritium. No emissions sampling is required for the single licensed emission unit on the PNNL-Sequim campus.

54 ENVIRONMENTAL SCIENCES↗

Landscape-scale characterization of Arctic tundra vegetation composition, structure, and function with a multi-sensor unoccupied aerial system

The Arctic is experiencing some of the most rapid climate change on Earth, with strong impacts on tundra ecosystems that are characterized by high land-surface and vegetation heterogeneity. Previous studies have explored this complexity using satellite remote sensing, however these typically coarse spatial resolution data have generally missed sub-pixel heterogeneity, leaving critical gaps in our understanding of tundra vegetation dynamics from the community to landscape scales. To address these gaps, we collected very high-resolution (1-5 cm) optical, structural, and thermal data at three low-Arctic tundra sites on the Seward Peninsula, Alaska, using a multi-sensor unoccupied aerial system (UAS). We examined the application of these data to studying tundra vegetation dynamics, by quantifying (1) canopy height and thermoregulation (leaf-air temperature) of representative plant functional types (PFTs), (2) fine-scale patterns of vegetation composition across landscapes, and (3) impacts of fine-scale vegetation composition on landscape-scale variation of canopy height and thermoregulation. Our results show that deciduous tall shrubs (those that can potentially grow >2 m) had a strong cooling effect, with canopy temperatures significantly lower than local air temperatures and other PFTs. Increased cover of tall shrubs also had the potential to reduce the cover of low-stature PFTs across the landscape, potentially associated with their closed canopy (i.e., increased light competition) and strong thermoregulation. To understand the connections between fine-scale vegetation composition and large-scale ecosystem processes, we produced a random forest model which showed that fine-scale PFT composition accounted for 86.8% and 74.2% of the landscape-scale variation in canopy height and thermoregulation, respectively. These findings highlight the importance of spatially detailed characterization of tundra PFTs to improve our ecological understanding and model representation of tundra vegetation, also transcend our study to show the need for continued collection of similar datasets to better understand the impacts of surface heterogeneity on the mapping and modeling of tundra ecosystem dynamics, as well as assist with conservation management and biodiversity monitoring strategies.

54 ENVIRONMENTAL SCIENCES↗

Reconciliation of asynchronous satellite-based $\mathrm{NO_2}$ and $\mathrm{XCO_2}$ enhancements with mesoscale modeling over two urban landscapes

Fossil fuel carbon dioxide (CO 2ff ), the main driver of global warming and climate change, is often co-emitted with nitrogen oxides (NO x ) and precursors to ground-level ozone from anthropogenic sources like power plants or vehicles. In urban and suburban areas, satellite-based NO 2 can be used as a proxy to track the emissions of CO 2ff . Because of NO 2 ’s shorter lifetime, urban NO 2 plumes are more distinguishable from backgrounds and more sensitive to variations in emissions. However, the combination of these two gases is limited by the asynchrony among NO 2 and CO 2 monitoring satellites. We used CO 2ff simulated by the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem) model to reconcile the tropospheric NO 2 vertical column density (VCD) from the Tropospheric Monitoring Instrument (TROPOMI) and column-averaged dry-air mole fractions of carbon dioxide enhancements (ΔXCO 2 ) from Orbiting Carbon Observatory 3 (OCO-3) Snapshot Area Maps (SAMs) over a multicity area, Washington D.C.-Baltimore (DC-Balt), and a basin city, Mexico City. NO 2 /CO 2ff ratios over DC-Balt are smaller than Mexico City, indicative of stricter emission restrictions, a more combustion-efficient vehicle fleet, and higher combustion efficiency due to lower altitude in DC-Balt. For single-track cases, the spatial correlations between NO 2 and ΔXCO 2 over Mexico City are stronger than DC-Balt because the NO 2 and CO 2 are mostly trapped in the valley of Mexico City, while DC-Balt is severely affected by distant sources (i.e., US East Coast cities). Using multi-track averaging, spatial correlation coefficients increase with the number of days used for averaging. The correlations reached a maximum when averaging >12 continuous images for DC-Balt and > 10 continuous images for Mexico City. This finding indicates that multi-track averaging using modeled CO 2ff as a proxy is helpful to filter the noise in single-track images, to cancel the interference from distant sources, and to magnify correlations between NO 2 and CO 2ff . Mexico City showed stronger spatial correlations but weaker temporal correlations than DC-Balt due to biomass burning hot spots and large transport errors caused by the trapping effects of the surrounding mountains. Tracking the 20-day moving average of CO 2ff emissions using TROPOMI NO 2 seems technically feasible, considering the relationship between correlation coefficients and the number of available satellite images.

54 ENVIRONMENTAL SCIENCES↗

2018 Annual Site Environmental Report Summary

We are committed to act as stewards of our environment to achieve our mission in accordance with all applicable environmental requirements. We set continual improvement objectives and targets, measure and document our progress, and share our results with our workforce, sponsors, and public. We reduce our environmental risk through legacy cleanup, pollution prevention, and long-term sustainability programs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Continuous Light Absorption Photometer (CLAP) Instrument Handbook

Reliable measurements of aerosol light absorption are crucial for quantifying the radiative forcing of climate. As a consequence, light absorption measurements are recommended for all stations in the Global Atmosphere Watch network, which is coordinated by the World Meteorological Organization. Aerosol light absorption is often dominated by soot-like particles produced by the incomplete combustion of carbonaceous fuels, commonly termed "black carbon", and optical methods are the primary way that equivalent black carbon concentrations are derived. Two basic approaches are used for determining the aerosol light absorption coefficient: in situ methods where the absorption is measured while the particles are suspended in air, and filter-based methods where the particles are deposited on a filter for real-time optical analysis. In situ methods are inherently more accurate because the physical state of the particles can be changed by the act of filtration. Unfortunately, currently available instruments for in situ measurements are more expensive and difficult to operate than filter-based methods, making them better suited for use in intensive field campaigns or as laboratory reference instruments. Filter-based instruments, because of their lower cost and simpler operation, have been the preferred choice for long-term measurements of aerosol light absorption in monitoring networks.

54 ENVIRONMENTAL SCIENCES↗

Sap Velocity Data for Urban Trees in Chicago, Illinois (2024-2025)

This dataset contains uncorrected sap velocity measurements using the heat ratio method (HRM) collected using ICT International SFM1x sensors at five urban sites in Chicago, Illinois, as part of the DOE CROCUS project. The data includes continuous monitoring of sap velocity from various tree species, including Maples (Acer spp.): Sugar Maple (Acer saccharum), Silver Maple (Acer saccharinum), and Red Maple (Acer rubrum); Oaks (Quercus spp.): Swamp White Oak (Quercus bicolor); American Elm (Ulmus americana); Honey Locust (Gleditsia triacanthos); Cottonwood (Populus deltoides); and Tree of Heaven (Ailanthus altissima) across Chicago State University (CSU), Northeastern Illinois University (NEIU), Northwestern University (NU), University of Illinois Chicago (UIC), and West Woodlawn "Blacks in Green" (BIG). These include both street trees and those in urban park locations. Measurements were collected at 15-20 minute intervals, depending on the sensor, and transmitted via Long Range Wide Area Network (LoRaWAN) protocols. The wireless data was collected by Sage Network (https://sagecontinuum.org/) nodes. The dataset includes sensor ID, Global Positioning System (GPS) coordinates, tree species (common and scientific names), tree identification number, diameter at breast height (DBH in cm), uncorrected sap velocity measurements (cm/hr) from both inner and outer probes, and Sage Node identifiers so the data can be mapped to related variables such as air quality and wind speed that were collected on the Sage nodes. All timestamps are in local Chicago time (CDT/CST). Quality control flags are provided using a 3-bit binary system indicating physical range violations (< -10 or > 60 cm/hr), step spikes (absolute difference > 36 cm/hr), and stuck sensor conditions (> 10 consecutive identical values). These are raw data, not corrected for wood anatomy or species-specific characteristics. Data is provided in comma separated (CSV) format. This dataset is part of a larger collection of CROCUS environmental monitoring data, including linked datasets from Air Quality Transmitter (AQT) sensors, Weather Transmitter (WXT) sensors, and Multi-Function Research LoRaWAN (MFR) Nodes. DOIs for the supporting data are provided as part of this data package.

Chicago↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

Continuous sensor suite measurements of weather, energy, soil and flux at four PumpHouse sites at the East River, Colorado

The purpose of this package is to monitor energy and water fluxes using a comprehensive set of sensors integrated on a tripod set up at 4 locations at the East River watershed in Colorado in the Upper Colorado River Basin as part of the Scientific Focus Area (SFA) research led by the Lawrence Berkeley National Lab (LBNL). This is a continuous sensor suite measurements of weather, energy, soil and flux at four East River pumphouse sites (ER-PHS1, ER-PHS2, ER-PHS3 and ER-PHS4) include: (1) soil CO2 concentration, CO2 flux and heat flux from soil surface; (2) photosynthetic active radiation flux at 1 m; (3) incoming/outcoming short and long wave radiation at 1 m, and user calculated net short and long wave radiation; (4) oxygen concentration and surface infrared temperature; (5) soil volumetric water content, temperature, and electrical conductivity at 10, 30, 60, 115 cm depth 115 cm depth; (6) soil matric potential and temperature at 30 cm depth; (7) incoming short wave radiation at 3 m height; (8) rainfall precipitation; (9) lightning strikes and strike distances; (10) wind direction and speed, maximum wind gust at 3 m; (11) air temperature, vapor pressure and barometric pressure at 3 m; (12) X _axis_level and Y_axis_level_(degree), tilt of the ATMOS 41 sensor; (13) maximum rainfall rate; (14) relative humidity sensor temperature at 3 m; (15) internally calculated vapor pressure deficit at 3 m with vapor pressure, relative humidity and sensor temperature measurements; (16) user calculated vapor pressure.These datasets contain data from Oct 11 2019 to March 20, 2020, and new datasets will be updated on annual basis. Files uploaded in Excel and Word, with copies in csv and pdf format.

54 ENVIRONMENTAL SCIENCES↗

WHISPER: Wireless Home Identification and Sensing Platform for Energy Reduction

Many regions of the world benefit from heating, ventilating, and air-conditioning (HVAC) systems to provide productive, comfortable, and healthy indoor environments, which are enabled by automatic building controls. Due to climate change, population growth, and industrialization, HVAC use is globally on the rise. Unfortunately, these systems often operate in a continuous fashion without regard to actual human presence, leading to unnecessary energy consumption. As a result, the heating, ventilation, and cooling of unoccupied building spaces makes a substantial contribution to the harmful environmental impacts associated with carbon-based electric power generation, which is important to remedy. For our modern electric power system, transitioning to low-carbon renewable energy is facilitated by integration with distributed energy resources. Automatic engagement between the grid and consumers will be necessary to enable a clean yet stable electric grid, when integrating these variable and uncertain renewable energy sources. We present the WHISPER (Wireless Home Identification and Sensing Platform for Energy Reduction) system to address the energy and power demand triggered by human presence in homes. The presented system includes a maintenance-free and privacy-preserving human occupancy detection system wherein a local wireless network of battery-free environmental, acoustic energy, and image sensors are deployed to monitor homes, record empirical data for a range of monitored modalities, and transmit it to a base station. Several machine learning algorithms are implemented at the base station to infer human presence based on the received data, harnessing a hierarchical sensor fusion algorithm. Results from the prototype system demonstrate an accuracy in human presence detection in excess of 95%; ongoing commercialization efforts suggest approximately 99% accuracy. Using machine learning, WHISPER enables various applications based on its binary occupancy prediction, allowing situation-specific controls targeted at both personalized smart home and electric grid modernization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AN EXPERIMENTAL STUDY OF FUEL SELECTION FOR A GASOLINE MULTI-MODE

In this study of fuels of different reactivities and their performance in a low-temperature combustion (LTC) engine. The engine was a 2.2L CRDI engine code D4HB provided by industry partner Hyundai America Technical Center inc. (HATCI). The engine was instrumented with in-cylinder pressure sensors allowing for monitoring of the combustion process. First, the engine was operated with standard US pump grade gasoline, Research Octane number (RON) 91 E10, to find initial operation conditions as well as control points of stable operation for daily checks on system conditions. Tested were 8 different fuel blends, the four base blends were provided by Phillips 66 (P66) with a RON value ranging from 60 to 91, and three other variations of these fuels were formulated by splash blending alcohols, iso-butanol, and ethanol, with the RON60 fuel and the final blend, was US RON91 E10 pump gasoline. Using these 8 fuels, the low load performance was analyzed allowing a selection of one of the fuels to be made to proceed with experimentation. To study the low load performance of each fuel, the load was decreased until combustion became too unstable to continue. This was done at 1500 rpm with all of the fuels. At 1200 rpm, the same methodology was applied, though all of the fuels were not tested, only the fuels which showed promise at 1500 rpm. Meaning that the lowest targeted load was achieved without any aid to the combustion process other than advancing combustion, increasing intake air temperature (IAT) for example was not done to maintain consistency across all fuels. The same methodology was applied at 800 rpm based upon the 1200 rpm results to see the ability of the engine to idle with the given fuel. It was found that fuel with a RON of 80 showed good low load performance while allowing for high load performance to be maintained. A blend of 25% Iso-Butanol and 75% RON 60 equated to a RON of 80 and showed good low load performance and showed peak indicated thermal efficiency (ITE) numbers of 46% at 17 bar indicated mean effective pressure (IMEP) and 2200 rpm.

02 PETROLEUM↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

The Assistant Secretary of the Army (Installations, Energy and Environment) tasked the Pacific Northwest National Laboratory to examine plug loads in typical Army buildings. Plug loads (also known as miscellaneous electric loads (MELs)) represent the electricity used by appliances and devices that are plugged in or hardwired and serve functions outside of a building’s core end uses. Common plug loads include computers, printers, copiers, networking devices, refrigerators, and vending machines. They also include personal electronic devices such as televisions, smart phones, tablets, and gaming systems. Examples of hardwired MELs include elevators, air compressors, and fire and security systems. The findings from this study confirm that significant energy is consumed within Army buildings by plug load devices and hardwired MEL equipment. A number of opportunities are identified for reducing unnecessary energy use that could save the Army over $5 million per year when broadly applied. Army regulations clearly spell out expectations for the purchase and operation of information technology equipment (computers, laptops, monitors, printers, and multi-function devices). However, the policies regarding the shutdown or activation of sleep and other lower power modes after 30 minutes of inactivity (15 minutes for monitors) do not appear to be consistently followed. There are many effective approaches and pathways for impacting change as it relates to improving awareness, implementing measures, and adjusting behaviors to identify and reduce plug load energy use. The Army should prioritize and consider deploying all of these to better understand and manage plug load equipment to save energy and enhance resilience across their facilities. Engaging the building occupants who use these devices daily via outreach and education should be a strong component of the strategy. The focus should be on reducing waste without sacrificing productivity or the benefits that many of these devices provide. Continued evaluation of plug loads beyond that performed here is important to gather lessons from additional building and equipment types, and to stay aware of evolving device technology and management options. This will highlight additional needs for policies, best practices, control technologies, and education of personnel to achieve real reductions in energy waste from plug load equipment. It is recommended that this study may serve as the foundation for a broader and sustained focus on plug loads and MELs, towards simultaneously enhancing the productivity, readiness, and resilience of the Army while reducing energy use and demand, and freeing up resources to better support the mission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimation of sensor measurement errors in reactor coolant systems using multi-sensor fusion

A nuclear power plant is typically instrumented with a variety of sensors to continually monitor its variables, and their sensor’s measurements may be used to assess the plant state and initiate safety actions, if needed. Errors in sensor measurements, due to factors such as calibration drifts, critically affect such state assessments. Here, we address a problem of estimating sensor errors using physics-informed machine learning methods that use measurements collected under known plant conditions. For a given sensor, we propose an information fusion method that uses measurements from other sensors to estimate its output assuming it is error-free and provides its difference from an actual measurement as an error estimate. We present the ensemble of trees and support vector machine fusers, and evaluate their performance using measurements collected over an emulated test loop of a pressurized water reactor. The plant variables are related to each other through the underlying physical laws under inertial constraints that place bounds on their derivatives, which analytically justify the applicability of machine learning methods for computing these fusers. Under twenty scenarios, we assess their sensor error estimates for pressure sensors of the heat exchanger of a reactor’s primary coolant system. Multiple types of errors are captured by both fusers under externally induced calibration drifts, blockages, minor leaks and air gaps in sensing lines, and electromagnetic interference; the root mean square error of the estimation of error is under 2.2% percent of the maximum measurement. We present generalization equations, in the framework of statistical learning theory, for these methods that characterize the confidence probability that the estimation error is bounded by a specified parameter in future test scenarios.