Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “contingency analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A nonsmooth nonconvex optimization algorithm for two-stage optimization problems

An optimization algorithm for a group of nonsmooth nonconvex problems inspired by two-stage stochastic programming problems is proposed. The main challenges for these problems include (1) the problems lack the popular lower-type properties such as prox-regularity assumed in many nonsmooth nonconvex optimization algorithms, (2) the objective can not be analytically expressed and (3) the evaluation of function values and subgradients are computationally expensive. To address these challenges, this report first examines the properties that exist in many two-stage problems, specifically upper-C 2 objectives. Then, we show that quadratic penalty method for securityconstrained alternating current optimal power flow (SCACOPF) contingency problems can make the contingency solution functions upper-C 2 . Based on these observations, a simplified bundle algorithm that bears similarity to sequential quadratic programming (SQP) method is proposed. It is more efficient in implementation and computation compared to conventional bundle methods. Global convergence analysis of the algorithm is presented under novel and reasonable assumptions. The proposed algorithm therefore fills the gap of theoretical convergence for smoothed SCACOPF problems. The inconsistency that might arise in our treatment of the constraints are addressed through a penalty algorithm whose convergence analysis is also provided. Finally, theoretical capabilities and numerical performance of the algorithm are demonstrated through numerical examples.

97 MATHEMATICS AND COMPUTING↗

Temperature and Water Levels Collectively Regulate Methane Emissions From Subtropical Freshwater Wetlands

Abstract Wetlands are the largest and most climate‐sensitive natural sources of methane. Accurately estimating wetland methane emissions involves reconciling inversion (“top‐down”) and process‐based (“bottom‐up”) models within the global methane budget. However, estimates from these two model types are inherently interdependent and often reveal substantial discrepancies. To enhance the reliability of both approaches, we need a comprehensive understanding of wetland methane emissions and an independent high‐resolution long‐term flux data set. Here, we employed a data‐driven random forest approach to identify key variables influencing methane emissions from subtropical freshwater wetlands in the Southeastern United States. The model‐estimated monthly mean methane fluxes fit well with measured methane fluxes ( R 2 = 0.67) at four representative FLUXNET‐CH4 wetland sites across the region. Variable importance analysis highlighted the sensitivity of subtropical freshwater wetland methane emissions to variations in both temperature and water levels. High temperatures facilitate methanogenesis by enhancing microbial activities, while elevated water levels maintain anaerobic conditions necessary for methane production. Notably, the response of methane emissions to water level fluctuations is contingent on temperature conditions, and vice versa. Moreover, we constructed the first high‐spatial‐resolution (∼1 km × 1 km) and long‐term (1982–2010) gridded regional wetland methane flux product for the Southeastern United States, estimating annual methane emissions from subtropical freshwater wetlands in the region at 4.93 ± 0.11 Tg CH 4 yr −1 for 1982–2010. This new benchmark product holds promise for validating and parameterizing uncertain wetland methane emission processes in bottom‐up models and provides improved prior information for top‐down models.

He, Keqi [Earth and Climate Sciences Nicholas Scho↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of AP1000 Small-Break Loss-of-Coolant Accident Using Reactor Transient Simulator

The Westinghouse Electric Company’s Advanced Passive Reactor (AP1000) is characterized by the incorporation of passive safety systems (PSSs) designed to ensure core cooling during transient events. The assessment of PSSs requires evaluation of their performance through a combination of experiments and simulations employing various thermal-hydraulic codes. In addition, detailed evaluation of PSSs for a specific reactor system transient analysis such as loss-of-coolant-accident analysis supports understanding representative integral effects test facility development and the further evolution model development and assessment process. Developing a reactor system code is a complex and time-consuming process that requires significant engineering expertise and effort. It can take several months to even years to complete in the early stages of reactor system design and analysis. However, this process can be expedited through the use of transient simulator models for similar reactor systems, which can be used for lesson learning and training purposes. This study uses the Personal Computer Transient Analyzer (PCTRAN) code. The main advantage of PCTRAN is its ease of use and ability to run faster than real time. This study presents the results obtained for a small-break loss-of-coolant accident (SBLOCA) for two breaks using the full version (licensed) of PCTRAN. The purpose of this investigation is to evaluate the overall system behavior during the postulated SBLOCA event as well as assess the capability of the PCTRAN code to reproduce the system response during transient events. The obtained results were compared with the Westinghouse NOTRUMP system code. The PCTRAN code proved to be reliable in predicting the qualitative behavior of the system in both transient cases. As for the system response, it was found that it is contingent on the activation time of the PSSs. The differences in reactor coolant system pressure between the two codes were attributed to the critical flow model and simplification of mass and energy balance. Despite PCTRAN’s limitations, it can still provide a reasonable prediction of various reactor parameters such as pressure, mass flow rate, and void fraction during a SBLOCA scenario. It is worth noting that PCTRAN currently employs a bulk approach similar to that of the Modular Accident Analysis Program (MAAP) and MELCOR codes. However, the upcoming version of PCTRAN will include an artificial intelligence–based detection and accident prevention system, as well as different models for different reactor components. Consequently, PCTRAN has the potential to be upgraded to match the system thermal-hydraulic codes of the U.S. Nuclear Regulatory Commission and become more widely used in cybersecurity to safeguard nuclear power plants from cyberattacks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data recovery via covert cognizance for unattended operational resilience

One of the important premises of unattended operation, a highly promoted characteristic of fission batteries and advanced microreactors, is the ability to automate the analysis of sensors data used in support of operational monitoring and control. Here, to meet this vision, this work proposes a new monitoring and data recovery paradigm to ensure resilience against data corruption which may be the result of malicious intrusion into the reactor operational network. This is paramount to ensure 100% availability under contingency scenarios such as cyberattacks. In support of this vision, earlier work has presented the concept of covert cognizance and demonstrated its mathematical ability to identify and embed cognizance parameters under the noise-dominated null space of the sensors data. This work extends this concept and applies it in real-time to demonstrate three key characteristics: zero-impact, zero-observability, and data recovery, where the first characteristic is to ensure no impact on operation, the second is immunity to discovery by pattern recognition techniques, and the third is to allow recovery of corrupt or falsified data. Recognizing that fission batteries are designed to operate under steady state most of the time, we elect to employ a small modular reactor model under transient operational conditions to demonstrate the operational resilience enabled by the covert cognizance paradigm. Specifically, the PI controller is augmented with the covert cognizance modules to develop self-awareness and enable automatic data recovery. The developed modules are expected to be equally applicable to a wide range of advanced reactor technologies relying on full or partial unattended control.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Co-Simulation Framework for Steady-State Analyses of Multiple Droop-based MTdc Grids in Continental-Scale Systems

The growing scale and complexity of planning continental hybrid ac and multi-terminal dc (MTdc) systems require scalable steady-state modeling and analysis approaches not currently available in commercial tools. This paper presents a comprehensive multi-fidelity model-conversion framework that enables the efficient transition of MTdc grid models from production cost modeling (PCM) and approximated ac power flow to detailed ac–MTdc power flow for large-scale planning studies. The core of this framework is a scalable co-simulation approach that, for the first time, enables power flow analysis in continental-scale ac–MTdc systems. It seamlessly couples commercial ac solvers with a detailed MTdc grid model that incorporates droop-based control and current-limiting strategies of multiple meshed MTdc grids. Leveraging this capability, an evaluation framework to systematically assess and compare different MTdc power redispatch strategies under ac and dc contingencies is introduced. The proposed framework and algorithm are evaluated using a combined Western and Eastern Interconnection system with 11 MTdc grids of various sizes, showing a coherent transition from PCM to detailed ac–MTdc power flow and improved system performance in voltage regulation and line overload mitigation following typical contingencies.

Nguyen, Quan H.↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Elevated-temperature cyclic properties of advanced manufactured materials

Microreactor developers at the 2019 GAIN Microreactors workshop expressed a need for advanced manufacturing to fabricate microreactor components. Powder metallurgy (PM) hot isostatic pressing (HIP) is more mature than other advanced manufacturing techniques for the following reasons: 1. a code case exists for Section III, Division 1, Subsection NB components of light water reactors to be manufactured using PM HIP Alloy 316L, and 2. tensile and creep properties have been shown to be equivalent to wrought material for Type 316 stainless steel and Grade 91. Thus, PM HIP is more readily deployable in the near term. Elevated-temperature cyclic properties of PM-HIP materials, however, have not been established. The scope of testing for Code qualification could be significantly reduced compared to a new material for the following reasons: 1. only a limited amount of time consuming creep testing would be required, and 2. testing of fatigue and creep-fatigue behavior could be reduced if it can be demonstrated that the properties are comparable to wrought material. The objective of this work package is to develop an understanding of the relationship of advanced materials processing on the material characteristics as they relate to elevated-temperature component design and construction. This will be achieved by the following: • Elevated-temperature fatigue and creep-fatigue testing of PM HIP and wrought Alloy 316L. • Fracture and microstructural characterization of the PM HIP and wrought Alloy 316L. • Analysis of the elevated-temperature fatigue and creep-fatigue properties of PM HIP Alloy 316L. • Draft a report evaluating the elevated-temperature fatigue and creep-fatigue properties of PM HIP Alloy 316L. • Pursue procurement of Alloy 316H and Grade 91 manufactured using PM HIP. • Initiate scoping studies of the procured Alloy 316H or Grade 91 manufactured using PM HIP contingent upon successful material procurement.

36 MATERIALS SCIENCE↗

The Essence of Cryptol: A Denotational Cryptol Interpreter in Coq for Foundational Assurances for Quantum Resistant Cryptosystems

Systems of the utmost consequence need a means to establish authenticity of software and data. Cryptosystems implement authentication, but can be vulnerable to cryptographic and implementation attacks. With the threat of quantum cryptographic attacks, “post-quantum” cryptosystems (PQCs) must be henceforth used in these systems. However, the new cryptography needs new ways to, rigorously and machine-checkably, prove systems free of vulnerabilities. We propose a retargetable capability to rapidly instantiate proven correct postquantum cryptosystems through novel proof-carrying synthesis and proof-automation technique, extending those proven successful on existing systems. This capability is crucial to meeting the cryptographic requirements for future high-consequence systems. Since specifications for high consequence cryptography are presently captured in a domain specific language known as Cryptol. While this can enable convenient fully automated reasoning about Cryptol specificaitons and implementations via the Software Analysis Workbench (SAW), Cryptol has expressivity gaps, so that cryptosystems with probabilistic programming features like Falcon cannot be fully expressed in the language. Moreover, SAW’s automation fails for programs and specificaitons with inductive and recursive structure, as in the Sphincs+ PQC. Finally, Cryptol and SAW together represent some 200,000 lines of unverified Haskell, so that the any guarantees about high consequence cryptography are presently contingent on a large, unverified, yet trusted computing base. The first step of the larger project of agile, assured crpytography is therefore to provide a formal, mechanized semantics for Cryptol, so that the specifications expressed by cryptographers in Cryptol can be reasoned about and compiled into performant implementations with a foundational, machine checkable certificate of correctness. This report describes our work on this first step, culminating in the design of a certified denotational interpreter, in Coq, for core Cryptol.

97 MATHEMATICS AND COMPUTING↗

Simulating Impacts of Extreme Events on Grids with High Penetrations of Wind Power Resources

As extreme weather events become more frequent and intense, the demand for connecting grid operation and infrastructure planning with extreme event models will increase as well. We present a methodology for creating damage contingencies and scenarios for electric transmission grids during a hurricane strike. Included is an example case study: Hurricane Dolly damaging a synthetic 2000 bus test system during its landing in Southern Texas. Using WIND Toolkit meteorological data in conjunction with fragility curves for various electric grid elements, we generate stochastic damage scenarios that can be used for short- and long-term planning problems including emergency asset management. We perform statistical analysis of damages and quantify topological effects on example synthetic grid. Also, we investigate loss-of-load events during two-day economic dispatch experiment. Finally, we point out various shortcomings of our method and suggest how it can be improved.

data-driven forecasting↗

Synchrotron-based techniques for characterizing STCH water-splitting materials

Understanding the role of oxygen vacancy–induced atomic and electronic structural changes to complex metal oxides during water-splitting processes is paramount to advancing the field of solar thermochemical hydrogen production (STCH). The formulation and confirmation of a mechanism for these types of chemical reactions necessitate a multifaceted experimental approach, featuring advanced structural characterization methods. Synchrotron X-ray techniques are essential to the rapidly advancing field of STCH in part due to properties such as high brilliance, high coherence, and variable energy that provide sensitivity, resolution, and rapid data acquisition times required for the characterization of complex metal oxides during water-splitting cycles. X-ray diffraction (XRD) is commonly used for determining the structures and phase purity of new materials synthesized by solid-state techniques and monitoring the structural integrity of oxides during water-splitting processes (e.g., oxygen vacancy–induced lattice expansion). X-ray absorption spectroscopy (XAS) is an element-specific technique and is sensitive to local atomic and electronic changes encountered around metal coordination centers during redox. While in operando measurements are desirable, the experimental conditions required for such measurements (high temperatures, controlled oxygen partial pressures, and H 2 O) practically necessitate in situ measurements that do not meet all operating conditions or ex situ measurements. Here, we highlight the application of synchrotron X-ray scattering and spectroscopic techniques using both in situ and ex situ measurements, emphasizing the advantages and limitations of each method as they relate to water-splitting processes. The best practices are discussed for preparing quenched states of reduction and performing synchrotron measurements, which focus on XRD and XAS at soft (e.g., oxygen K-edge, transition metal L-edges, and lanthanide M-edges) and hard (e.g., transition metal K-edges and lanthanide L-edges) X-ray energies. The X-ray absorption spectra of these complex oxides are a convolution of multiple contributions with accurate interpretation being contingent on computational methods. The state-of-the-art methods are discussed that enable peak positions and intensities to be related to material electronic and structural properties. Through careful experimental design, these studies can elucidate complex structure–property relationships as they pertain to nonstoichiometric water splitting. A survey of modern approaches for the evaluation of water-splitting materials at synchrotron sources under various experimental conditions is provided, and available software for data analysis is discussed.

08 HYDROGEN↗

Can section 45Q tax credit foster decarbonization? A case study of geologic carbon storage at Acid Gas Injection wells in the Permian Basin

Carbon capture, utilization, and storage (CCUS) is an important pathway for meeting climate mitigation goals. While the economic viability of CCUS is well understood, previous studies do not evaluate the economic feasibility of carbon capture and storage (CCS) in the Permian Basin specifically regarding the new Section 45Q tax credits. We developed a technoeconomic analysis method, evaluated the economic feasibility of CCS at the acid gas injection (AGI) wells, and assessed the implication of Section 45Q tax credits for CCS at the AGIs. We find that the compressors, well depth, and the permit and monitoring costs drive the facility costs. Compressors are the predominant contributors to capital and operating expenditure driving the levelized cost of CO 2 storage. Strategic cost reduction measures identified include 1) sourcing of low-cost electricity and 2) optimizing operational efficiency in well operations. In evaluating the impact of the tax credits on CCS projects, facility scale proved decisive. We found that facilities with an annual injection rate exceeding 10,000 MT storage capacity demonstrate economic viability contingent upon the procurement of inputs at the least cost. The new construction of AGI wells were found to be economically viable at a storage capacity of 100,000 MT. The basin is heavily focused on CCUS (tax credit – $\$$65/MT CO 2 ), which overshadows CCS ($\$$85/MT CO 2 ) opportunities. Balancing the dual objectives of CCS and CCUS requires planning and coordination for optimal resource and pore space utilization to attain the basin's decarbonization potential. We also found that CCS on AGI is a lower cost CCS option as compared to CCS on other industries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The role of annealing and grain boundary controls on the mechanical properties of limestones and marbles

Chemical and mechanical processes are coupled in many geological and geochemical environments. Reactive processes anneal defects and restructure grain boundaries, modifying their elastic properties, levels of internal friction, wave propagation rates and fracture behaviors. The nature of these changes is, however, contingent on the initial state of the rock. Here, in this study, impulse excitation was used to measure changes in mechanical properties as a function of dry and steam heating time at 300 °C for three carbonate rocks: Carrara marble, Carthage marble (Burlington Limestone), and Texas Cream limestone (Edwards limestone), with initial porosities of about 1 %, 3 %, and 27 %, respectively. Frequency-dependent phenomena along with mineral recrystallization were observed. This was coupled with small-angle X-ray and neutron scattering analysis to determine the relationship between changes in bulk mechanical and microstructural properties. An observed decrease in both the Young's and shear moduli in the experimental limestones as a function of heating time reflects and quantifies a reduction in the stiffness of the rock due to annealing. The internal friction of the samples first increases then decreases with reaction time, reflecting defect annealing, but this was balanced against grain boundary dissolution apparently driven by condensation of steam in the confined grain-boundary environment. This suggests an increase in the boiling point under confinement leading to dissolution, increased porosity and widening of the grain boundaries. In addition, comparison of small-angle X-ray and neutron scattering results suggests that it is inappropriate to assume that pores are empty for quantitative analysis of typical small-angle scattering samples.

58 GEOSCIENCES↗

PowerModelsGAT-AI: Physics-Informed Graph Attention for Multi-System Power Flow With Continual Learning

Solving the alternating current power flow equations in real time is essential for secure grid operation, yet classical Newton–Raphson solvers can be slow under stressed conditions. Existing graph neural networks for power flow are typically trained on a single system and often degrade on different systems. We present PowerModelsGAT-AI, a physics-informed graph attention network that predicts bus voltages and generator injections. The model uses bus-type-aware masking to handle different bus types and balances multiple loss terms, including a power-mismatch penalty, using learned weights. We evaluate the model on 14 benchmark systems (4 to 6,470 buses) and train a unified model on 13 of these under contingency conditions with up to two branch outages, achieving an average normalized mean absolute error of 0.89% for voltage magnitudes and R 2 >0.99 for voltage angles. We also show continual learning: when adapting a base model to a new 1,354-bus system, standard fine-tuning causes severe forgetting with error increases exceeding 1000% on base systems, while our experience replay and elastic weight consolidation strategy keeps error increases below 2% and in some cases improves base-system performance. Interpretability analysis shows that learned attention weights correlate with physical branch parameters (susceptance: r=0.38 ; thermal limits: r=0.22 ), and feature importance analysis supports that the model captures established power flow relationships.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Wide-Area Oscillation Damping Control using Measurement-Driven Approach on System Separation - Saudi Grid Case Study

In any interconnected power grid, low-frequency oscillations is a major problem that can limit the power transfer capability and deteriorate power system security due to potential low-damped or even undamped oscillations. Synchronized measurements provided by PMUs enable the design and development of wide-area oscillation damping controllers (WADC) based on measurement-driven model to overcome the limitations of traditional controllers. This work focuses on the impact of a W ADC based on a measurement-driven approach on system separation for the Saudi Electricity Company (SEC) grid. A grid model is provided by SEC for this study. Modal analysis is performed to identify the oscillation mode of interest for which the controller is designed. Damping the dominant oscillation mode helps slightly to improve transient stability of the system. Considering bus frequency at different locations in SEC's system as the candidate observation signals, the optimal observation signal is chosen for the W ADC by using the FFT method. The system transfer function model is constructed by utilizing probing measurements. Then, the W ADC parameters are calculated based on the identified model. The performance of the designed W ADC is tested under different contingencies.

Altarjami, Ibrahim↗

Sensitivity-Based Reactive Power Dispatch of DERs to Support Transmission Grid During Emergency

This paper proposes a TSO-DSO framework including DER set-point dispatch using sensitivity analysis. We address all three steps of TSO-DSO integration stating by estimating the capability curve of an unbalanced distribution system and then modeling of capability curve on the transmission side grid and estimating the reactive power needed from DSO during emergencies, and ending by dispatching the requested reactive power from TSO. The proposed interaction framework is tested on an IEEE 37-node distribution network connected to IEEE 9 bus transmission system. The simulation shows that using sensitivity-based dispatch would reduce the number of communication signals between DERs and DSO and that can decrease the risk of communication contingency.

Alkhonain, Ahmed↗