Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “confidence measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Electrical circuit control in power systems

Electrical circuit control techniques in power systems are disclosed herein. In one embodiment, a supervisory computer in the power system can be configured to fit phasor measurement data from phasor measurement units into a Gaussian distribution with a corresponding Gaussian confidence level. When the Gaussian confidence level of the fitted Gaussian distribution is above a Gaussian confidence threshold, the supervisory computer can be configured to perform an ambient analysis on the received phasor measurement data to determine an operating characteristic of the power system. The supervisory computer can then automatically applying at least one electrical circuit control action to the power system in response to the determined operating characteristic.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equibiaxial Flexure Strength of a Superfine-Grained Nuclear Graphite

The strength of advanced graphite is reported in accordance with ASTM D7846-16 using a two-parameter Weibull distribution for uniaxial strength testing. The rule of thumb for Weibull distributions is to use a minimum of 30 strength measurements to have a high level of confidence in the Weibull characteristic strength and the Weibull modulus. These large sample sets for statistical confidence are easily obtained for as-manufactured graphite, but determination of the Weibull two-factor parameters on graphite that has been exposed to neutron irradiation is nearly impossible due to irradiation testing restraints on specimen size and space limitations in test reactors for the accommodation of specimens. These restrictions have resulted in irradiation programs that use sub-sized specimens to measure uniaxial strength change, but the specimen geometries still hinder the number of replicate specimens for each irradiation condition. In contrast, this work used an advanced ceramic standard, ASTM C1499-05, as the foundation for equibiaxial strength testing of a superfine-grained nuclear graphite to investigate the irradiation-induced strength change and any changes to the two-parameter Weibull distribution. The goal was to investigate the effect of specimen size on the two-parameter Weibull distribution parameters in support of the small specimens and geometry desired for irradiation. A study of the effect of a reduced sample population was also undertaken to investigate the reliability of using the two-parameter Weibull distribution to study changes to the materials properties caused by neutron irradiation damage. The results of this work suggest that these equibiaxial specimens would be ideal for statistically significant studies of the effects of irradiation on the Weibull characteristic strength (but not the modulus) and for providing a method for surveillance specimen campaigns for future operating commercial reactors.

Campbell, Anne↗

Discrimination of phosgene from cyanogen chloride in recovered chemical munitions using tagged neutron interrogation with high-resolution gamma-ray spectroscopy

The Associated Particle technique has recently been utilized with a germanium-based high-resolution $\gamma$-ray spectrometer and assessed for its capability to improve field identification of recovered chemical warfare (CW) materiel through prompt gamma-ray neutron activation analysis (PGNAA) measurements. An accurate chemical identification is necessary for the safe handling, destruction, and disposal of such hazardous items. A particularly challenging pair of CW agents commonly found in recovered munitions are phosgene (CG) and cyanogen chloride (CK), which have two of three elements in common, i.e. chlorine and carbon, but differ in the third being either oxygen or nitrogen. The detection of both latter elements is complicated by high oxygen concentration in the field environment which interferes with the small signal produced from the chemical agents. The matter is further complicated by the precautionary field practice of overpacking recovered munitions with vermiculite in larger steel multiple round containers (MRCs), which places additional oxygen-rich material around the munition while further attenuating an already weak signal emitted from the munition center. Here, this work reports quantitative results from realistic field measurements of CG and CK simulants in mock 4.2-inch mortar rounds overpacked with vermiculite in a large MRC. Results obtained with the AP technique are compared to those obtained with the traditional PGNAA approach for both overpacked- and bare-munition measurements. The AP technique is shown to provide a much more confident discrimination between the two chemicals, particularly for the more challenging field-relevant overpacked measurements, where a significant gain in sensitivity to all the key elements chlorine, carbon, nitrogen and oxygen is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Microscopy-Guided Laser Ablation Electrospray Ionization Ion Mobility Mass Spectrometry: Ambient Single Cell Metabolomics with Increased Confidence in Molecular Identification

Single cell analysis is a field of increasing interest as new tools are continually being developed to understand intercellular differences within large cell populations. Laser-ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging technique for single cell metabolomics. Over the years, it has been validated that this ionization technique is advantageous for probing the molecular content of individual cells in situ. Here, we report the integration of a microscope into the optical train of the LAESI source to allow for visually informed ambient in situ single cell analysis. Additionally, we have coupled this ‘LAESI microscope’ to a drift-tube ion mobility mass spectrometer to enable separation of isobaric species and allow for the determination of ion collision cross sections in conjunction with accurate mass measurements. This combined information helps provide higher confidence for structural assignment of molecules ablated from single cells. Here, we show that this system enables the analysis of the metabolite content of Allium cepa epidermal cells with high confidence structural identification together with their spatial locations within a tissue.

59 BASIC BIOLOGICAL SCIENCES↗

SPARTAN and IMPROVE Comparison Experiment (SPICE) Interim Campaign Report

SPICE (the SPARTAN and IMPROVE Comparison Experiment) aims to obtain and quantify comparisons between aerosol PM 2.5 mass concentration measurements from the University of Oklahoma (OU) Surface Particulate Matter Network (SPARTAN) station and the U.S. Environmental Protection Agency (EPA) Interagency Monitoring of Protected Visual Environments (IMPROVE) station hosted by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility at ARM’s Southern Great Plains (SGP) observatory in Oklahoma. Aerosols—both natural and anthropogenic—affect human populations in multiple ways. Much of ARM’s research focuses on how aerosols influence weather and climate through their optical and radiative effects, as well as their impacts on clouds and precipitation. However, aerosols also pose direct risks to humans and other organisms through inhalation, with the severity of health impacts depending on particle size, chemical composition, and duration of exposure. The IMPROVE network was established by the U.S. EPA to monitor air quality, including visible clarity as well as total and chemically speciated aerosol mass concentrations. The ARM SGP site hosts the IMPROVE SOGP station. Separately, the SPARTAN network operates a globally distributed set of stations similar to IMPROVE but with an emphasis on remote deployment and semi-autonomous operation for use beyond the borders of the United States (IMPROVE only operates within the U.S.). The University of Oklahoma operates a SPARTAN station. To establish confidence in the OU SPARTAN instrumentation and measurement protocol relative to the EPA-certified IMPROVE station, the OU SPARTAN station is currently deployed at SGP in close proximity to the IMPROVE SOGP station. The SPICE campaign was envisioned as a contiguous calendar-year effort for 2025 to capture seasonal variation in mass loading as well as composition. However, independent of the SPICE campaign, the SPARTAN network adopted a new filter construction part-way through the year, interrupting our contiguous data set. Thus, to obtain a contiguous data set with a uniform consistent configuration, SPICE desires an extension through 2026.

54 ENVIRONMENTAL SCIENCES↗

An Improved Measurement of the Secondary Cosmic Microwave Background Anisotropies from the SPT-SZ + SPTpol Surveys

We report new measurements of millimeter-wave power spectra in the angular multipole range $2000 \le \ell \le 11,000$ (angular scales $5^\prime \gtrsim \theta \gtrsim 1^\prime$). By adding 95 and 150\,GHz data from the low-noise 500 deg$^2$ SPTpol survey to the SPT-SZ three-frequency 2540 deg$^2$ survey, we substantially reduce the uncertainties in these bands. These power spectra include contributions from the primary cosmic microwave background, cosmic infrared background, radio galaxies, and thermal and kinematic Sunyaev-Zel'dovich (SZ) effects. The data favor a thermal SZ (tSZ) power at 143\,GHz of $D^{\rm tSZ}_{3000} = 3.42 \pm 0.54~ \mu {\rm K}^2$ and a kinematic SZ (kSZ) power of $D^{\rm kSZ}_{3000} = 3.0 \pm 1.0~ \mu {\rm K}^2$. This is the first measurement of kSZ power at $\ge 3\,\sigma$. We study the implications of the measured kSZ power for the epoch of reionization, finding the duration of reionization to be $\Delta z_{re} = 1.0^{+1.6}_{-0.7}$ ($\Delta z_{re}< 4.1$ at 95% confidence), when combined with our previously published tSZ bispectrum measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

β -Nuclear-Recoil Correlation from $^6$$\mathrm{He}$ Decay in a Laser Trap

Here, we report the first precise measurement of a β-recoil correlation from a radioactive noble gas ( 6 He) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield |C T /C A | 2 ≤ 0.022 (90% confidence limit, C.L.). On the other hand, for left-handed neutrinos the limits are 0.007 < C T /C A < 0.111 (90% C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the microchannel plate used for recoil ion detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative assessment of fitting errors associated with streak camera noise in Thomson scattering data analysis

Thomson scattering measurements in high energy density experiments are often recorded using optical streak cameras. In the low-signal regime, noise introduced by the streak camera can become an important and sometimes the dominant source of measurement uncertainty. In this paper, we present a formal method of accounting for the presence of streak camera noise in our measurements. We present a phenomenological description of the noise generation mechanisms and present a statistical model that may be used to construct the covariance matrix associated with a given measurement. This model is benchmarked against simulations of streak camera images. We demonstrate how this covariance may then be used to weight fitting of the data and provide quantitative assessments of the uncertainty in the fitting parameters determined by the best fit to the data and build confidence in the ability to make statistically significant measurements in the low-signal regime, where spatial correlations in the noise become apparent. These methods will have general applicability to other measurements made using optical streak cameras.

47 OTHER INSTRUMENTATION↗

An Improved Measurement of the Secondary Cosmic Microwave Background Anisotropies from the SPT-SZ + SPTpol Surveys

We report new measurements of millimeter-wave power spectra in the angular multipole range 2000 ≤ ℓ ≤ 11,000 (angular scales ). By adding 95 and 150 GHz data from the low-noise 500 deg 2 SPTpol survey to the SPT-SZ three-frequency 2540 deg 2 survey, we substantially reduce the uncertainties in these bands. These power spectra include contributions from the primary cosmic microwave background, cosmic infrared background, radio galaxies, and thermal and kinematic Sunyaev–Zel'dovich (SZ) effects. The data favor a thermal SZ (tSZ) power at 143 GHz of and a kinematic SZ (kSZ) power of . This is the first measurement of kSZ power at ≥3 σ . However, different assumptions about the CIB or SZ models can reduce the significance down to 2.4 σ in the worst case. We study the implications of the measured kSZ power for the epoch of reionization under the Calabrese et al. model for the kSZ power spectrum and find the duration of reionization to be ( at 95% confidence), when combined with our previously published tSZ bispectrum measurement. The upper limit tightens to if the assumed homogeneous kSZ power is increased by 25% (~0.5 μ K 2 ) and relaxes to if the homogeneous kSZ power is decreased by the same amount.

79 ASTRONOMY AND ASTROPHYSICS↗

The metabolic origins of non-photorespiratory CO 2 release during photosynthesis: a metabolic flux analysis

Respiration in the light (R L ) releases CO 2 in photosynthesizing leaves and is a phenomenon that occurs independently from photorespiration. Since R L lowers net carbon fixation, understanding R L could help improve plant carbon-use efficiency and models of crop photosynthesis. Although R L was identified more than 75 years ago, its biochemical mechanisms remain unclear. To identify reactions contributing to R L , we mapped metabolic fluxes in photosynthesizing source leaves of the oilseed crop and model plant camelina (Camelina sativa). We performed a flux analysis using isotopic labeling patterns of central metabolites during 13 CO 2 labeling time course, gas exchange, and carbohydrate production rate experiments. To quantify the contributions of multiple potential CO 2 sources with statistical and biological confidence, we increased the number of metabolites measured and reduced biological and technical heterogeneity by using single mature source leaves and quickly quenching metabolism by directly injecting liquid N 2 ; we then compared the goodness-of-fit between these data and data from models with alternative metabolic network structures and constraints. Our analysis predicted that R L releases 5.2 μmol CO2 g –1 FW h –1 of CO 2 , which is relatively consistent with a value of 9.3 μmol CO 2 g –1 FW h –1 measured by CO 2 gas exchange. The results indicated that ≤10% of R L results from TCA cycle reactions, which are widely considered to dominate R L . Further analysis of the results indicated that oxidation of glucose-6-phosphate to pentose phosphate via 6-phosphogluconate (the G6P/OPP shunt) can account for >% of CO 2 released by R L .

59 BASIC BIOLOGICAL SCIENCES↗

Estimate of background baseline and upper limit on the chiral magnetic effect in isobar collisions at $\sqrt{S_{NN}}$=200 GeV at the BNL Relativistic Heavy Ion Collider

For the search of the chiral magnetic effect (CME), STAR previously presented the results from isobar collisions ($^{96}_{44}$Ru + $^{96}_{44}$Ru, $^{96}_{40}$Zr + $^{96}_{40}$Zr) obtained through a blind analysis. The ratio of results in Ru+Ru to Zr+Zr collisions for the CME-sensitive charge-dependent azimuthal correlator (Δ⁢𝛾), normalized by elliptic anisotropy (𝑣2), was observed to be close to but systematically larger than the inverse multiplicity ratio. The background baseline for the isobar ratio, 𝑌= (Δ⁢𝛾/𝑣2) Ru /(Δ⁢𝛾/𝑣2) Zr , is naively expected to be (1/𝑁) Ru /(1/𝑁) Zr ; however, genuine two- and three-particle correlations are expected to alter it. We estimate the contributions to 𝑌 from those correlations, utilizing both the isobar data and hijing simulations. After including those contributions, we arrive at a final background baseline for 𝑌, which is consistent with the isobar data. Here, we extract an upper limit for the CME fraction in the Δ⁢𝛾 measurement of approximately 10% at a 95% confidence level on in isobar collisions at $\sqrt{S_{NN}}$=200 GeV, with an expected 15% difference in their squared magnetic fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FY21 Progress of the Oak Ridge Health Physics Research Reactor CAAS Benchmark Evaluation [Slides]

The FY21 version of the evaluation, focusing on element 57 dose at 3 meters, was presented at the ICSBEP Technical Review Group meeting in October 2021 and was not accepted for 2022 publication in the handbook. The main issue was identified and replacement of the element 57 neutron dose benchmark metric by neutron fluence (closer to what was measured) is required. A subgroup was formed, confident for the updated neutron fluence evaluation to be accepted in the ICSBEP handbook. The updated evaluation will be presented again at the 2022 ICSBEP TRG for publication in the 2023 handbook.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Study for Validation of Resilient Response of Controls - Thrust 2 Controls Assessment

The focus of this project is to design, execute, and analyze experiments around resilience response. As part of the Resilience through Data-Driven, Intelligently Designed Control (RD2C) initiative, this project builds upon the previously designed control algorithms and experiments. It designs detailed uses cases to test RD2C-developed mitigation schemes in specific realistic scenarios, analyze and save the measurement data sets. Having a high-confidence and consistent data set is crucial for identifying relevant metrics to describe the system resilience in specific real-life-like scenarios of power grid operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pegasus IV: Discovery and Spectroscopic Confirmation of an Ultra-faint Dwarf Galaxy in the Constellation Pegasus

We report the discovery of Pegasus IV, an ultra-faint dwarf galaxy found in archival data from the Dark Energy Camera processed by the DECam Local Volume Exploration Survey. Pegasus IV is a compact, ultra-faint stellar system ( pc; M $_{V}$ = −4.25 ± 0.2 mag) located at a heliocentric distance of . Based on spectra of seven nonvariable member stars observed with Magellan/IMACS, we confidently resolve Pegasus IV’s velocity dispersion, measuring km s$^{−1}$ (after excluding three velocity outliers); this implies a mass-to-light ratio of for the system. From the five stars with the highest signal-to-noise spectra, we also measure a systemic metallicity of [Fe/H] = dex, making Pegasus IV one of the most metal-poor ultra-faint dwarfs. We tentatively resolve a nonzero metallicity dispersion for the system. These measurements provide strong evidence that Pegasus IV is a dark-matter-dominated dwarf galaxy, rather than a star cluster. We measure Pegasus IV’s proper motion using data from Gaia Early Data Release 3, finding (μ $_{α*}$, μ $_{δ}$) = (0.33 ± 0.07, −0.21 ± 0.08) mas yr$^{−1}$. When combined with our measured systemic velocity, this proper motion suggests that Pegasus IV is on an elliptical, retrograde orbit, and is currently near its orbital apocenter. Lastly, we identify three potential RR Lyrae variable stars within Pegasus IV, including one candidate member located more than 10 half-light radii away from the system’s centroid. The discovery of yet another ultra-faint dwarf galaxy strongly suggests that the census of Milky Way satellites is still incomplete, even within 100 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

Surrogate modeling for efficiently, accurately and conservatively estimating measures of risk

We present a surrogate modeling framework for conservatively estimating measures of risk from limited realizations of an expensive physical experiment or computational simulation. Risk measures combine objective probabilities with the subjective values of a decision maker to quantify anticipated outcomes. Given a set of samples, we construct a surrogate model that produces estimates of risk measures that are always greater than their empirical approximations obtained from the training data. These surrogate models limit over-confidence in reliability and safety assessments and produce estimates of risk measures that converge much faster to the true value than purely sample-based estimates. We first detail the construction of conservative surrogate models that can be tailored to a stakeholder’s risk preferences and then present an approach, based on stochastic orders, for constructing surrogate models that are conservative with respect to families of risk measures. Our surrogate models include biases that permit them to conservatively estimate the target risk measures. We provide theoretical results that show that these biases decay at the same rate as the L 2 error in the surrogate model. Numerical demonstrations confirm that risk-adapted surrogate models do indeed overestimate the target risk measures while converging at the expected rate.

42 ENGINEERING↗

Surrogate Modeling For Efficiently Accurately and Conservatively Estimating Measures of Risk

We present a surrogate modeling framework for conservatively estimating measures of risk from limited realizations of an expensive physical experiment or computational simulation. We adopt a probabilistic description of risk that assigns probabilities to consequences associated with an event and use risk measures, which combine objective evidence with the subjective values of decision makers, to quantify anticipated outcomes. Given a set of samples, we construct a surrogate model that produces estimates of risk measures that are always greater than their empirical estimates obtained from the training data. These surrogate models not only limit over-confidence in reliability and safety assessments, but produce estimates of risk measures that converge much faster to the true value than purely sample-based estimates. We first detail the construction of conservative surrogate models that can be tailored to the specific risk preferences of the stakeholder and then present an approach, based upon stochastic orders, for constructing surrogate models that are conservative with respect to families of risk measures. The surrogate models introduce a bias that allows them to conservatively estimate the target risk measures. We provide theoretical results that show that this bias decays at the same rate as the L 2 error in the surrogate model. Our numerical examples confirm that risk-aware surrogate models do indeed over-estimate the target risk measures while converging at the expected rate.

97 MATHEMATICS AND COMPUTING↗

Direct neutrino-mass measurement based on 259 days of KATRIN data

That neutrinos carry a nonvanishing rest mass is evidence of physics beyond the Standard Model of elementary particles. Their absolute mass holds relevance in fields from particle physics to cosmology. We report on the search for the effective electron antineutrino mass with the KATRIN experiment. KATRIN performs precision spectroscopy of the tritium β-decay close to the kinematic endpoint. On the basis of the first five measurement campaigns, we derived a best-fit value of $m^{2}_{v} = -0.14^{+0.13}_{-0.15}$ eV 2 , resulting in an upper limit of m ν < 0.45 eV at 90% confidence level. Stemming from 36 million electrons collected in 259 measurement days, a substantial reduction of the background level, and improved systematic uncertainties, this result tightens KATRIN’s previous bound by a factor of almost two.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The HOSTS Survey for Exozodiacal Dust: Observational Results from the Complete Survey

The Large Binocular Telescope Interferometer (LBTI) enables nulling interferometric observations across the N band (8 to 13 μm) to suppress a star’s bright light and probe for faint circumstellar emission. We present and statistically analyze the results from the LBTI/Hunt for Observable Signatures of Terrestrial Systems survey for exozodiacal dust. By comparing our measurements to model predictions based on the solar zodiacal dust in the N band, we estimate a 1σ median sensitivity of 23 zodis times the solar system dust surface density in its habitable zone (HZ; 23 zodis) for early-type stars and 48 zodis for Sun-like stars, where 1 zodi is the surface density of HZ dust in the solar system. Of the 38 stars observed, 10 show significant excess. A clear correlation of our detections with the presence of cold dust in the systems was found, but none with the stellar spectral type or age. The majority of Sun-like stars have relatively low HZ dust levels (best-fit median: 3 zodis, 1σ upper limit: 9 zodis, 95% confidence: 27 zodis based on our N band measurements), while ~20% are significantly more dusty. The solar system’s HZ dust content is consistent with being typical. Our median HZ dust level would not be a major limitation to the direct imaging search for Earth-like exoplanets, but more precise constraints are still required, in particular to evaluate the impact of exozodiacal dust for the spectroscopic characterization of imaged exo-Earth candidates.

79 ASTRONOMY AND ASTROPHYSICS↗