Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condensate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Condensation shocks in hypersonic nitrogen tunnels

Experimental observations and a theoretical model for the onset and disappearance of condensation are provided for hypersonic flows of pure nitrogen at M = 10, 14, and 18. A method for analyzing the thermodynamic and flow properties of a partially condensed mixture from known supply conditions and measured Pitot pressure yields the local static pressure and temperature, mass fraction of the nitrogen condensed, and the Mach number of the partially condensed flow based on frozen sound speed. The transition between partially condensed-supercooled flow is found to occur at 22-25 K isobaric supercooling with the corresponding mass fraction condensed being 12-14 percent over a range of two orders of magnitude in local static pressure. The heat released and vapor mass removed during condensation ultimately raise the local pressure and temperature and reduce the flow Mach number.

Hudson, Susan T.↗

Characterization of spacecraft humidity condensate

When construction of Space Station Freedom reaches the Permanent Manned Capability (PMC) stage, the Water Recovery and Management Subsystem will be fully operational such that (distilled) urine, spent hygiene water, and humidity condensate will be reclaimed to provide water of potable quality. The reclamation technologies currently baselined to process these waste waters include adsorption, ion exchange, catalytic oxidation, and disinfection. To ensure that the baseline technologies will be able to effectively remove those compounds presenting a health risk to the crew, the National Research Council has recommended that additional information be gathered on specific contaminants in waste waters representative of those to be encountered on the Space Station. With the application of new analytical methods and the analysis of waste water samples more representative of the Space Station environment, advances in the identification of the specific contaminants continue to be made. Efforts by the Water and Food Analytical Laboratory at JSC were successful in enlarging the database of contaminants in humidity condensate. These efforts have not only included the chemical characterization of condensate generated during ground-based studies, but most significantly the characterization of cabin and Spacelab condensate generated during Shuttle missions. The analytical results presented in this paper will be used to show how the composition of condensate varies amongst enclosed environments and thus the importance of collecting condensate from an environment close to that of the proposed Space Station. Although advances were made in the characterization of space condensate, complete characterization, particularly of the organics, requires further development of analytical methods.

Muckle, Susan↗

Investigation of Condensing Ice Heat Exchangers for MTSA Technology Development

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal, carbon dioxide (CO2) and humidity control for a Portable Life Support Subsystem (PLSS). Metabolically-produced CO2 present in the ventilation gas of a PLSS is collected using a CO2selective adsorbent via temperature swing adsorption. The temperature swing is initiated through cooling to well below metabolic temperatures. Cooling is achieved with a sublimation heat exchanger using water or liquid carbon dioxide (LCO2) expanded below sublimation temperature when exposed to low pressure or vacuum. Subsequent super heated vapor, as well as additional coolant, is used to further cool the astronaut. The temperature swing on the adsorbent is then completed by warming the adsorbent with a separate condensing ice heat exchanger (CIHX) using metabolic heat from moist ventilation gas. The condensed humidity in the ventilation gas is recycled at the habitat. The water condensation from the ventilation gas is a significant heat transfer mechanism for the warming of the adsorbent bed because it represents as much as half of the energy potential in the moist ventilation gas. Designing a heat exchanger to efficiently transfer this energy to the adsorbent bed and allow the collection of the water is a challenge since the CIHX will operate in a temperature range from 210K to 280K. The ventilation gas moisture will first freeze and then thaw, sometimes existing in three phases simultaneously. A NASA Small Business Innovative Research (SBIR) Phase 1 contract was performed to investigate condensing and icing as applied to MTSA to enable higher fidelity modeling and assess the impact of geometry variables on CIHX performance for future CIHX design optimization. Specifically, a design tool was created using analytical relations to explore the complex, interdependent design space of a condensing ice heat exchanger. Numerous variables were identified as having nontrivial contributions to performance such as hydraulic diameter, heat exchanger effectiveness, ventilation gas mass flow rate and surface roughness. Using this tool, four test articles were designed and manufactured to map to a full MTSA subassembly (the adsorbent bed, the sublimation heat exchanger for cooling and the condensing ice heat exchanger for warming). The design mapping considered impacts due to CIHX geometry as well as subassembly impacts such as thermal mass and thermal resistance through the adsorbent bed. The test articles were tested at simulated PLSS ventilation loop temperature, moisture content and subambient pressure. Ice accumulation and melting were observed. Data and test observations were analyzed to identify drivers of the condensing ice heat exchanger performance. This paper will discuss the analytical models, the test article designs, and testing procedures. Testing issues will be discussed to better describe data and share lessons learned. Data analysis and subsequent conclusions will be presented.

Padilla, Sebastian↗

Deepak Condenser Model (DeCoM)

Development of the DeCoM comes from the requirement of analyzing the performance of a condenser. A component of a loop heat pipe (LHP), the condenser, is interfaced with the radiator in order to reject heat. DeCoM simulates the condenser, with certain input parameters. Systems Improved Numerical Differencing Analyzer (SINDA), a thermal analysis software, calculates the adjoining component temperatures, based on the DeCoM parameters and interface temperatures to the radiator. Application of DeCoM is (at the time of this reporting) restricted to small-scale analysis, without the need for in-depth LHP component integrations. To efficiently develop a model to simulate the LHP condenser, DeCoM was developed to meet this purpose with least complexity. DeCoM is a single-condenser, single-pass simulator for analyzing its behavior. The analysis is done based on the interactions between condenser fluid, the wall, and the interface between the wall and the radiator. DeCoM is based on conservation of energy, two-phase equations, and flow equations. For two-phase, the Lockhart- Martinelli correlation has been used in order to calculate the convection value between fluid and wall. Software such as SINDA (for thermal analysis analysis) and Thermal Desktop (for modeling) are required. DeCoM also includes the ability to implement a condenser into a thermal model with the capability of understanding the code process and being edited to user-specific needs. DeCoM requires no license, and is an open-source code. Advantages to DeCoM include time dependency, reliability, and the ability for the user to view the code process and edit to their needs.

Patel, Deepak↗

Mars Atmospheric CO2 Condensation Above the North and South Poles as Revealed by Radio Occultation, Climate Sounder, and Laser Ranging Observations

We study the condensation of CO2 in Mars atmosphere using temperature profilesretrieved from radio occultation measurements from Mars Global Surveyor (MGS) as wellas the climate sounding instrument onboard the Mars Reconnaissance Orbiter (MRO),and detection of reflective clouds by the MGS Mars Orbiter Laser Altimeter (MOLA). Wefind 11 events in 1999 where MGS temperature profiles indicate CO2 condensation andMOLA simultaneously detects reflective clouds. We thus provide causal evidence thatMOLA non-ground returns are associated with CO2 condensation, which strongly indicatestheir nature being CO2 clouds. The MGS and MRO temperature profiles together revealthe seasonal expansion and shrinking of the area and the vertical extent of atmosphericsaturation. The occurrence rate of atmospheric saturation is maximized at high latitudes inthe middle of winter. The atmospheric saturation in the northern polar region exhibits moreintense seasonal variation than in the southern polar region. In particular, a shrinking ofsaturation area and thickness from LS 270 to 300 in 2007 is found; this is probablyrelated to a planet-encircling dust storm. Furthermore, we integrate the condensation areaand the condensation occurrence rate to estimate cumulative masses of CO2 condensatesdeposited onto the northern and southern seasonal polar caps. The precipitation flux isapproximated by the particle settling flux which is estimated using the impulse responses ofMOLA filter channels. With our approach, the total atmospheric condensation mass canbe estimated from these observational data sets with average particle size as the onlyfree parameter. By comparison with the seasonal polar cap masses inferred from thetime-varying gravity of Mars, our estimates indicate that the average condensate particleradius is 822 mm in the northern hemisphere and 413 mm in the southern hemisphere.Our multi-instrument data analysis provides new constraints on modeling the global climateof Mars.

MOLA↗

Lignin Extraction and Condensation as a Function of Temperature, Residence Time, and Solvent System in Flow-through Reactors

Solvolytic extraction of lignin from biomass is a critical step in lignin-first biorefining, including the reductive catalytic fractionation (RCF) process. Key to optimal RCF processing is the ability to rapidly extract lignin from biomass at high delignification extents and transfer the lignin molecules to a catalyst surface in a time frame that minimizes lignin condensation reactions. Here, we use a flow-through reactor to study the effects of temperature (175-250 °C), residence time (9 to 36 min), and solvent composition (methanol and methanol-water) on lignin extraction and condensation. We evaluated three metrics at each condition: total delignification, delignification rate, and extent of condensation, the latter measured by a decrease in monomer yield for batch hydrogenolysis reactions of solvolysis liquor compared to batch RCF reactions. We observe that delignification is predominantly determined by temperature, while residence time dictates the lignin condensation extent. Moreover, the extent of both extraction and condensation increased in the methanol-water solvent system compared to that in the methanol system. Lignin extracted in methanol is stable up to 18-min residence times at or below 225 °C, while a majority of the lignin extracted in methanol-water is condensed with a 9-min residence time at 200 °C. These results can inform reactor designs and solvent selection for lignin-first biorefining processes that aim to physically separate the biomass and catalyst.

09 BIOMASS FUELS↗

Direct observation of the quantum fluctuation driven amplitude mode in a microcavity polariton condensate

The Higgs amplitude mode is a collective excitation studied and observed in a broad class of matter, including superconductors, charge density waves, antiferromagnets, 3He p-wave superfluid, and ultracold atomic condensates. In all the observations reported thus far, the amplitude mode was excited by perturbing the condensate out of equilibrium. Studying an exciton-polariton condensate, here, we report the observation of this amplitude mode purely driven by intrinsic quantum fluctuations without such perturbations. By using an ultrahigh quality microcavity and a Raman spectrometer to maximally reject photoluminescence (PL) from the condensate, we observe weak but distinct PL at energies below the condensate emission. We identify this as the so-called ghost branches of the amplitude mode arising from quantum depletion of the condensate into this mode. These energies, as well as the overall structure of the PL spectra, are in good agreement with our theoretical analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Composite Structured Surfaces for Durable Dropwise Condensation

Dropwise condensation of steam on hydrophobic substrates has a 10X higher heat transfer coefficient compared to filmwise condensation. To promote dropwise condensation, low surface energy hydrophobic coatings (polymers) are typically utilized. The low intrinsic thermal conductivity (k < 1 W/(m · K)) of polymers, coupled with high heat transfer coefficient of dropwise condensation (100 kW/(m 2 · K)), necessitates that the coating be thin (< 1µm) in order to avoid reducing the overall heat exchanger conductance. However, thin polymeric films easily degrade. The two opposing requirements result in the need for optimization between the durability (thick coating) and the heat transfer (thin coating). To enable high thermal conductivity in thicker coatings, we develop metal-polymer structured surfaces. By using porous structures as inter-connected heat-conducting backbones that are filled with hydrophobic materials, we enable tuning of the coating effective thermal conductivity and surface energy. Three metal structures were studied; micro/nanowires, inverse opals, and sintered spheres. Heat transfer performance was calculated using three-dimensional finite element method simulations with two distinct boundary conditions; convection at the walls and isothermal walls. Interestingly, the overall conductance shows up to 40% difference depending on the boundary condition used in calculating the composite coating effective thermal conductivity. We use our model to predict the heat transfer performance as a function of metal fraction by volume and by surface area for condensation. By coupling our thermal simulations with a previously verified analytical model for predicting wetting behavior on heterogeneous surfaces, we propose a regime map to predict dropwise-to-filmwise transition. Furthermore, our work not only forms a starting point for the development of durable dropwise condensing surfaces, it identifies important considerations needed for computing effective thermal conductivity of composites.

42 ENGINEERING↗

Oxide-catalyzed self- and cross-condensation of cycloketones. Kinetically relevant steps that determine product distribution

Metal oxides with acid-base properties can be used to catalyze aldol condensation and potentially obtain valuable chemicals from biomass-derived oxygenates. Understanding the reaction mechanisms could enable the development of effective catalysts with controllable selectivity. In this work, we investigate the reaction parameters that affect the kinetics and product distribution of self- and cross-aldol condensation of cyclopentanone (CPO) and cyclohexanone (CHO) over CeO 2 and ZrO 2 catalysts by combining detailed analysis of experiments and DFT calculations. It is well-known that either the deprotonation of an α-C–H that generates an enolate or the C–C coupling that produces the dimers can be rate-limiting step. Indeed, the detailed kinetics analysis shows that the observed data can be fitted by unimolecular or bimolecular Langmuir-Hinshelwood models. Specifically, on the ZrO 2 catalyst, the unimolecular α-C–H activation is the rate limiting step for the CPO self-condensation, while the bimolecular C–C coupling limits the CHO self-condensation. By contrast, on CeO 2 , the bimolecular C–C coupling step seems to be rate-limiting for both CPO and CHO self-condensation reactions. The adsorption parameters derived from kinetics fitting indicate that when the two reactants are co-fed, the surface is preferentially covered by CHO. So, the condensation rate of [CPO]-activated products ([CPO]CPO + [CPO]CHO) decreases in the presence of CHO, due to the competitive adsorption. However, despite a higher surface coverage, CHO is not an effective electrophile because it imposes stronger steric constraints to the formation of the C–C bond than CPO. Therefore, for a given enolate, the product distribution shows that [CPO]CPO > [CPO]CHO and, similarly [CHO]CPO > [CHO]CHO. Likewise, the yields of [CPO]- and [CHO]-activated products in mixed CPO/CHO feeds are similar because the higher surface coverage and stability of the [CHO] enolate is counterbalanced by the inhibition of C–C coupling by steric constraints when CHO is involved. In summary, the overall rank of products observed experimentally can be explained in terms of a combination of the following effects: relative surface coverage of the reactants, steric constraints for the C–C coupling, stability of the enolate, and effectiveness of the electrophile to accept an electron.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flexible and Extensive Platinum Ion Gel Condensers for Programmable Catalysis

Catalytic condensers composed of ion gels separating a metal electrode from a platinum-on-carbon active layer were fabricated and characterized to achieve more powerful, high surface area dynamic heterogeneous catalyst surfaces. Ion gels comprised of poly(vinylidene difluoride)/1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide were spin coated as a 3.8 μm film on a Au surface, after which carbon sputtering of a 1.8 nm carbon film and electron-beam evaporation of 2 nm Pt clusters created an active surface exposed to reactant gases. Electronic characterization indicated that most charge condensed within the Pt nanoclusters upon application of a potential bias, with the condenser device achieving a capacitance of ∼20 μF/cm 2 at applied frequencies of up to 120 Hz. The maximum charge of ∼10 14 |e – | cm –2 was condensed under stable device conditions at 200 °C on catalytic films with ∼10 15 sites cm –2 . Grazing incidence infrared spectroscopy measured carbon monoxide adsorption isobars, indicating a change in the CO* binding energy of ∼19 kJ mol –1 over an applied potential bias of only 1.25 V. Condensers were also fabricated on flexible, large area Kapton substrates allowing stacked or tubular form factors that facilitate high volumetric active site densities, ultimately enabling a fast and powerful catalytic condenser that can be fabricated for programmable catalysis applications.

Catalysis↗

Designing a validation experiment for radio frequency condensation

Abstract Theoretical studies have suggested that nonlinear effects can lead to ‘radio frequency (RF) condensation’, where an initially broad current profile can coalesce in islands when they reach sufficient width. In suitable conditions, RF condensation can ‘self-focus’ the driven current to the center of an island, improving stabilization efficiency and reducing control complexity. In unsuitable conditions, the effect can prematurely deplete the RF energy before it reaches the island center, impairing stabilization. It is predicted that the RF condensation effect can significantly impact reactor-scale tokamaks. This paper presents a set of simulations investigating the conditions under which RF condensation might be encountered in present-day tokamaks. For concreteness, the calculations use equilibrium reconstructions for two shots from DIII-D and AUG. The Current Condensation Amid Magnetic Islands (OCCAMI) simulation code has been used for this investigation. The code takes as its input a numerically specified axisymmetric EFIT equilibrium solution, and it perturbatively constructs a 3D field with an island embedded at the appropriate rational surface. In the OCCAMI code, the GENRAY code is used for ray tracing and for calculating the power deposition along a ray trajectory, and GENRAY is coupled self-consistently to a solution of the thermal diffusion equation in the island. The simulation results described in the paper illuminate the conditions required for experimental validation of the theory of RF condensation. The simulations also provide an explanation of why the effect was not noticed in experiments prior to the publication of theoretical papers on the subject.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Subdimensional criticality: Condensation of lineons and planons in the X-cube model

We study quantum phase transitions out of the fracton ordered phase of the Z N X-cube model. These phase transitions occur when various types of subdimensional excitations and their composites are condensed. The condensed phases are either trivial paramagnets, or are built from stacks of D = 2 or 3 deconfined gauge theories, where D is the spatial dimension. Here, the nature of the phase transitions depends on the excitations being condensed. Upon condensing dipolar bound states of fractons or lineons, for N ≥ 4 we find stable critical points described by decoupled stacks of D = 2 conformal field theories. Upon condensing lineon excitations, when N > 4 we find a gapless phase intermediate between the X-cube and condensed phases, described as an array of D = 1 conformal field theories. In all these cases, effective subsystem symmetries arise from the mobility constraints on the excitations of the X-cube phase and play an important role in the analysis of the phase transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Entangled phase of simultaneous fermion and exciton condensations realized

Fermion-exciton condensates (FECs)—computationally and theoretically predicted states that simultaneously exhibit the character of superconducting states and exciton condensates—are novel quantum states whose properties may involve a hybridization of superconductivity and the dissipationless flow of energy. Here, we exploit prior investigations of superconducting states and exciton condensates on quantum devices to identify a tuneable quantum state preparation entangling the wave functions of the individual condensate states. Utilizing this state preparation, we prepare a variety of FEC states on quantum computers—realizing strongly correlated FEC states on current, noisy intermediate-scale quantum devices—and verify the presence of the dual condensate via postmeasurement analysis. This confirmation of the previously predicted condensate state on quantum devices as well as the form of its wave function motivates further theoretical and experimental exploration of the properties, applications, and stability of FECs.

36 MATERIALS SCIENCE↗

Lignin Extraction and Condensation as a Function of Temperature, Residence Time, and Solvent System in Flow-through Reactors

Solvolytic extraction of lignin from biomass is a critical step in lignin-first biorefining, including the reductive catalytic fractionation (RCF) process. Key to optimal RCF processing is the ability to rapidly extract lignin from biomass at high delignification extents and transfer the lignin molecules to a catalyst surface in a time frame that minimizes lignin condensation reactions. Here, we use a flow-through reactor to study the effects of temperature (175–250 °C), residence time (9 to 36 min), and solvent composition (methanol and methanol–water) on lignin extraction and condensation. We evaluated three metrics at each condition: total delignification, delignification rate, and extent of condensation, the latter measured by a decrease in monomer yield for batch hydrogenolysis reactions of solvolysis liquor compared to batch RCF reactions. We observe that delignification is predominantly determined by temperature, while residence time dictates the lignin condensation extent. Moreover, the extent of both extraction and condensation increased in the methanol–water solvent system compared to that in the methanol system. Lignin extracted in methanol is stable up to 18-min residence times at or below 225 °C, while a majority of the lignin extracted in methanol–water is condensed with a 9-min residence time at 200 °C. These results can inform reactor designs and solvent selection for lignin-first biorefining processes that aim to physically separate the biomass and catalyst.

biorefining↗

Characterization and Electrochemical Analysis of Acidic Condensate-Induced Corrosion on Aluminized Coating on Steel in Residential Heaters

Condensing furnace residential heaters are starting to replace outdated and less efficient non-condensing units in homes across the US. However, the burning of natural gas in these new units produces acidic gases, which can form acid droplets (H 2 SO 4 , HNO 3 , H 2 CO 3 , etc.) that are corrosive to low-grade heat exchanger metallic materials. Type-1 aluminized steel has been used in industrial applications, such as marine, heating, and automobile parts, due to its resistance to oxidation at elevated temperature. Many components of the condensing furnaces, including heat exchangers, are made from type-1 aluminized steel. We investigated the interaction of type-1 aluminized steel substrates with two acidic condensate liquids by 500 h corrosion exposures as well as short-term electrochemical impedance measurements. SEM plan and cross-sectional view images revealed damage to the Al-Si rich layer and exposure of the steel substrate. The non-uniform damage in the Al-Si rich layer was likely attributed to a pitting corrosion mechanism and induced by high acidity of the condensate liquid. Electrochemical impedance measurements in an acidic condensate revealed lower corrosion resistance of the aluminized steel surface with a weld line, identifying welded sections as preferential corrosion initiation sites.

36 MATERIALS SCIENCE↗

Switchable Wettability for Condensation Heat Transfer

Condensation proceeds as dropwise or filmwise depending on the wettability of the condensing surface. These two modes of condensation have disparate heat transfer coefficients, with dropwise often exceeding filmwise. This work reports a surface with switchable superhydrophilic to hydrophobic wetting behavior that can exhibit both modes of condensation. Relative to the highly-wetting state which yields filmwise condensation, the non-wetting state exhibits dropwise condensation and twice the heat transfer coefficient. Relevance to thermal management is additionally discussed.

Heat transfer↗

CFD Validation and Scaling of a Condenser Used in an ISRU Propellant Production System

This work develops a Computational Fluid Dynamics (CFD) model of a Commercial-Off-The-Shelf (COTS) condenser used for ground-based testing of an In-Situ Resource Utilization (ISRU) propellant production system. STAR-CCM+ was used to simulate water condensing through the condenser downstream of a methanation reactor. The computational data of the digital model is validated with test cases using nitrogen and water in ambient conditions. After validation with the test data, the digital model can be used to predict scale at higher production targets. The StarCCM+ simulation of the digital model shows good agreement with the test data provided. From the simulation, the condensation rate calculated was 18.3 g/hr and the process gas mass flow rate was 709.2 g/hr. The test data measured an average 16.9 g/hr condensation rate and 693.6 g/hr process gas mass flow rate. The simulation shows a 7.3% error in the water condensation and 2.2% error in the process gas at the outlet.

Condenser↗

Consequences of Intrapore Liquids on Reactivity, Selectivity, and Stability for Aldol Condensation Reactions on Anatase TiO 2 Catalysts

Abstract This study provides evidence and mechanistic interpretations for the significant consequences of intrapore non‐polar liquids on acetone aldol condensation turnover rates, selectivity to primary dimer products, and catalyst stability for reactions at Lewis acid‐base site pairs on TiO 2 surfaces. These non‐polar liquids confer such benefits through the preferential stabilization of transition states (TS) for adsorption (“entry”) and desorption (“exit”) steps, which place their respective reactants or products within a solvating outer sphere environment. The extent to which non‐polar fluids ( n ‐heptane) form an intrapore liquid phase within TiO 2 voids was obtained from N 2 uptakes using established formalisms that consider the different molal volume, surface tension, and volatility between N 2 and n ‐heptane. Acetone condensation rates are limited by C−H activation, an “entry” step that forms bound prop‐1‐en‐2‐olates via a TS stabilized by intrapore liquids, leading to higher aldol condensation turnover rates as n ‐heptane pressure increases and active TiO 2 surfaces become increasingly immersed within a non‐polar liquid phase. These liquids solvate the late TS structures that mediate the desorption of primary C 6 condensation products even more effectively than those involved in prop‐1‐en‐2‐olate formation or in nucleophilic attack events that later form C−C bonds. Such preferential solvation favors desorption over C−C coupling events, thus disfavoring the formation of larger oligomers that become stranded at active sites, thus leading to much slower deactivation. Moreover, solvation by non‐polar liquids also leads to C 6 alkanones as the sole products formed in a single surface sojourn. These effects of a non‐polar dense phase circumvent the inherent stability, reactivity, and selectivity hurdles that have precluded practical aldol condensation catalysis on Lewis acid‐base pairs at oxide surfaces; these consequences are demonstrated here for TiO 2 catalysts, acetone aldol condensation reactions, and n ‐heptane as the non‐polar liquid but through strategies, concepts, and mechanistic features that extend to other systems. More generally, these observations and their mechanistic origins demonstrate how a contacting liquid preferentially solvates TS structures for elementary steps that involve either reactants arriving from or products entering into an outer sphere environment that contains a dense non‐polar phase.

Kadam, Shashikant A.↗