Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compact heat exchangers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Cryogenic hydrogen-induced air-liquefaction technologies for combined-cycle propulsion applications

Given here is a technical assessment of the realization of cryogenic hydrogen induced air liquefaction technologies in a prospective onboard aerospace vehicle process setting. The technical findings related to the status of air liquefaction technologies are reviewed. Compact lightweight cryogenic heat exchangers, heat exchanger atmospheric constituent fouling alleviation measures, para/ortho-hydrogen shift-conversion catalysts, cryogenic air compressors and liquid air pumps, hydrogen recycling using slush hydrogen as a heat sink, liquid hydrogen/liquid air rocket-type combustion devices, and technically related engine concepts are discussed. Much of the LACE work is related to aerospaceplane propulsion concepts that were developed in the 1960's. Emphasis is placed on the Liquid Air Cycle Engine (LACE).

Escher, William J. D.↗

Microlith-Based Catalytic Reactor for Air Quality and Trace Contaminant Control Applications

Traditionally, gaseous compounds such as methane, carbon monoxide, and trace contaminants have posed challenges for maintaining clean air in enclosed spaces such as crewed spacecraft cabins as they are hazardous to humans and are often difficult to remove by conventional adsorption technology. Catalytic oxidizers have provided a reliable and robust means of disposing of even trace levels of these compounds by converting them into carbon dioxide and water. Precision Combustion, Inc. (PCI) and NASA - Marshall (MSFC) have been developing, characterizing, and optimizing high temperature catalytic oxidizers (HTCO) based on PCI's patented Microlith® technology to meet the requirements of future extended human spaceflight explorations. Current efforts have focused on integrating the HTCO unit with a compact, simple recuperative heat exchanger to reduce the overall system size and weight while also reducing its energy requirements. Previous efforts relied on external heat exchangers to recover the waste heat and recycle it to the oxidizer to minimize the system's power requirements; however, these units contribute weight and volume burdens to the overall system. They also result in excess heat loss due to the separation of the HTCO and the heat recuperator, resulting in lower overall efficiency. Improvements in the recuperative efficiency and close coupling of HTCO and heat recuperator lead to reductions in system energy requirements and startup time. Results from testing HTCO units integrated with heat recuperators at a variety of scales for cabin air quality control and heat melt compactor applications are reported and their benefits over previous iterations of the HTCO and heat recuperator assembly are quantified in this paper.

Vilekar, Saurabh↗

Energy Efficient Microlith-Based Catalytic Reactor and Recuperator for Air Quality Control Applications

Precision Combustion, Inc. (PCI) and NASA’s Marshall Space Flight Center (MSFC) have been developing, characterizing, and optimizing high temperature catalytic oxidizers (HTCO) based on PCI’s patented Microlith technology to meet the requirements of future extended human spaceflight explorations. Previous efforts focused on integrating PCI’s HTCO unit with a compact, simple recuperative heat exchanger to reduce the overall system size and weight. Significant improvement was demonstrated over traditional approaches of integrating the HTCO with an external recuperative heat exchanger. While the critical target performance metrics were achieved, the thermal effectiveness of PCI’s recuperator remained a potential area of improvement to further reduce the energy requirements of the integrated system. Using the same material combinations and an improved recuperator design, the redesigned prototype has experimentally demonstrated 20 – 30% reduction (flow dependent) in steady state power consumption compared to the earlier prototype without compromising the destruction efficiency of methane and volatile organic compounds (VOCs). Moreover, design modifications and improvements allow our redesigned prototype to be more easily manufactured compared to traditional brazed plate-fin recuperator designs. The redesigned prototype was delivered to MSFC for validation testing. Here, we report and discuss the performance of the improved prototype HTCO unit with a high efficiency recuperative heat exchanger based on testing at PCI and MSFC. The device is expected to provide a reliable and robust means of disposing of trace levels of methane and VOCs by oxidizing them into carbon dioxide and water in order to maintain clean air in enclosed spaces, such as crewed spacecraft cabins.

Vilekar, Saurabh A.↗

Particle Vertical Mixing and Horizontal Conveyance Within an Ambient Temperature Fluidized Bed

Previous studies have shown the advantages of particle-to-sCO2 fluidized bed (FB) heat exchangers, which include high heat transfer coefficients, low material cost, and the ability to horizontally convey solid particles. This paper outlines the design and testing of a compact cold flow FB test apparatus to characterize horizontal conveyance through convolutions within a 100 kWth FB heat exchanger design. Horizontal conveyance is an advantage in FBs because it enables more compact designs for heat exchangers. Two mass flow rates, 0.5 & 1 kg/s, at the inlet & outlet of the FB. To determine consistency of the flow rates, Student’s t-tests were used to assess whether the inlet & outlet values were statistically similar. The mass flow rate exiting the bed was statistically similar to the flow rate entering the bed for both cases, but each case featured a wider range and standard deviation. The range and standard deviation of the 1 kg/s flow rate was 0.69-1.23 kg/s and 0.12 kg/s respectively, and the 0.5 kg/s test featured a range and standard deviation of 0.37-0.73 kg/s and 0.09 kg/s, respectively. These measurements provide confidence that large-scale designs can successfully horizontally convey particles at ````~1.5x minimum fluidization velocity (U­mf) without significant variation in flow rate. A method to characterize the degree of particle vertical mixing and bubble frequency within the FB is also introduced. By using a high-resolution camera together with particle velocimetry, particle motion in the X and Y directions can be estimated to assess bed mixing and bubble frequency.

Khalaf, Jawad↗

Development of an Integrated Thermal Energy Storage Heat Exchanger for Concentrating Solar Power

In this design and development effort a latent-heat energy storage heat exchanger was designed for a 10MW e sCO 2 power plant as a basis for detailed design and testing of a new phase-change heat exchanger technology. High efficiency thermal conductors of graphite foam or folded copper were employed within chloride salt phase-change volumes bounded by alternating high density compact plate-fin heat exchange cells in this new heat exchanger technology. Test articles were constructed at Brayton Energy and tested at Argonne National Laboratory. Copper-conducting samples were constructed and tested at Brayton Energy.

14 SOLAR ENERGY↗

A high-performance lung-inspired ceramic 3D-printed heat exchanger for high-temperature energy-efficient systems

The thermal-to-electric conversion efficiency of next-generation supercritical carbon dioxide and concentrated solar power plants is significantly augmented by operating at temperatures exceeding 1000 °C if durable, compact, high-temperature heat exchangers (HXs) are developed. Whereas metal 3D-printed HXs fail to operate under extreme temperature conditions, ceramic 3D-printed HXs are deemed promising candidates for high-temperature, highly oxidizing environments. Ceramic 3D-printed HXs, however, exhibit a high gas permeability issue through hot and cold separating walls due to an excessive non-volatile photopolymer content utilized. Here, in this work, a novel leak-free lung-inspired ceramic 3D-printed HX employing a highly complex heat transfer topology is introduced for high-temperature energy-efficient systems. The high permeability issue of ceramic 3D-printed HXs is fully eliminated through a uniform zinc-based coating. It was determined that the effective thermal conductivity of the sintered ceramic heat exchangers is affected by the coated layer. The high-temperature thermal and hydraulic characteristics of the lung-inspired ceramic 3D-printed HX are comprehensively examined and compared against a millichannel 3D-printed HX module. Experimental results indicated that the lung-inspired 3D-printed ceramic HX significantly outperforms its millichannel counterpart. The lung-inspired HX shows a volume-based power density of 8.2 MW/m3 at a hot-side inlet air temperature of 700°C, a 71 % improvement compared with that of the millichannel HX. More importantly, the higher thermal duty of the lung-inspired 3D-printed HX is realized at a lower normalized pressure drop penalty of 510 Pa/W, 22 % lower than that of the millichannel ceramic HX. This study accelerates the advancement of high-performance ceramic 3D-printed HXs with complex topologies for high-temperature energy-efficient systems and/or corrosive environments.

42 ENGINEERING↗

Multi-Material Topology Optimization for High Performance Heat Exchangers

This award allowed RTX Technology Research Center to demonstrate several key objectives related to the design and manufacture of additive heat exchangers. The focus of the project was on creating a multi-physics, multi-material topology optimization tool, then using it to create an ultra-compact, optimized, fully additive heat exchanger.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical and Experimental Study of a Novel Additively Manufactured Metal-Polymer Composite Heat-Exchanger for Liquid Cooling Electronics

In order to meet increasing power-dissipation requirements of the electronics industry, compact, low-cost, and lightweight heat exchangers (HXs) are desired. With proper design, materials, and manufacture, polymer composite heat exchangers could meet these requirements. This paper presents a novel crossflow air-to-water, low-cost, and lightweight metal-polymer composite HX. This HX, which is entirely additively manufactured, utilizes a novel cross-media approach that provides direct heat exchange between air and liquid sides by using connecting fins. A robust numerical model was developed, which includes the dimensional effects of additive manufacturing. The study consists of a simplified 3D CFD model based on ellipsoidal-shaped staggered tube banks for the laminar range. It then uses an analytical approach to compute entire HX performance. The model is validated experimentally within 8% for thermal performance, 12% for air-side impedance, and 18% for water-side impedance. Finally, HX is compared with a conventional CPU radiator and performs within 10% of the conventional unit for reasonable flow rates and pressure-drop ranges. Moreover, HX also provides added design and cost advantages over the conventional unit, which makes the HX a potential candidate for electronic cooling applications.

30 DIRECT ENERGY CONVERSION↗

A Scalable Compact Additively Manufactured Molten Salt to Supercritical Carbon Dioxide Heat Exchanger for Solar Thermal Application

Design of an additively manufactured molten salt (MS) to supercritical carbon dioxide (sCO 2 ) primary heat exchanger (PHE) for solar thermal power generation is presented. The PHE is designed to handle temperatures up to 720 °C on the MS side and an internal pressure of 200 bar on the sCO 2 side. In the core, MS flows through a three-dimensional periodic lattice network, while sCO 2 flows within pin arrays. The design includes integrated sCO 2 headers located within the MS flow, allowing for a counterflow design of the PHE. The sCO 2 headers are configured to enable uniform flow distribution into each sCO 2 plate while withstanding an internal pressure of 200 bar and minimizing obstruction to the flow of MS around it. The structural integrity of the design is verified on additively manufactured (AM) 316 stainless steel sub-scale specimens. An experimentally validated, correlation-based sectional PHE core thermofluidic model is developed to study the impact of flow and geometrical parameters on the PHE performance, with varied parameters including the mass flowrate, surface roughness, and PHE dimensions. A process-based cost model is used to determine the impact of parameter variation on build cost. The model results show that a heat exchanger with a power density of 18.6 MW/m 3 (including sCO 2 header volume) and effectiveness of 0.88 can be achieved at a heat capacity rate ratio of 0.8. As a result, the impact of design and AM machine parameters on the cost of the PHE are assessed.

14 SOLAR ENERGY↗

Experimental Investigation of the Heat Transfer between Finned Tubes and a Bubbling Fluidized Bed with Horizontal Sand Mass Flow

The sandTES technology utilizes a fluidized bed counter current heat exchanger for thermal energy storage applications. Its main feature is an imposed horizontal flow of sand (SiO2) particles fluidized by a vertical air flow across a heat exchanger consisting of several horizontal rows of tubes. Past international research on heat transfer in dense fluidized beds has focused on stationary (stirred tank) systems, and there is little to no information available on the impact of longitudinal or helical fins. Previous pilot plant scale experiments at TU Wien led to the conclusion that the currently available correlations for predicting the heat transfer coefficient between the tube surface and the surrounding fluidized bed are insufficient for the horizontal sand flow imposed by the sandTES technology. Therefore, several smaller test rigs were designed in this study to investigate the influence of different tube arrangements and flow conditions on the external convective heat transfer coefficient and possible improvements by using finned tubes. It could be shown that helically finned tubes in a transversal arrangement, where the horizontal sand flow is perpendicular to the tube axes, allows an increase in the heat transfer coefficient per tube length (i.e., the virtual heat transfer coefficient) by a factor of 3.5 to about 1250 W/m2K at ambient temperature. Based on the literature, this heat transfer coefficient is expected to increase at higher temperatures. The new design criteria allow the design of compact, low-cost heat exchangers for thermal energy storage applications, in particular electro-thermal energy storage.

25 ENERGY STORAGE↗

Partial equilibrium model for predicting concentration of CO in combustion

A simple kinetic model, based upon the concept of partial equilibrium, is developed for predicting carbon monoxide concentrations in such steady-flow hydrocarbon-air combustion systems as gas-turbine combustors. The only two kinetic constraints used in the model are on the rate of change of the total number of gaseous particles in the system, and on the rate of change of the CO concentration. The accuracy of the model is verified by comparison with experimental results obtained by burning kerosene with air in a 130,000 Btu/hr atmospheric-pressure steady-flow burner. Burnt-gas cooling rates of 1,000,000 K/sec, about the magnitude encountered in the dilution zone of gas-turbine combustors, were obtained with a compact water-cooled heat exchanger. Good agreement between measured CO concentrations and the values predicted by the partial-equilibrium model was obtained.

Morr, A. R.↗

Thermohydraulic experiments on a supercritical carbon dioxide–air microtube heat exchanger

Heat exchangers are critical components in supercritical CO 2 Brayton cycles and provide necessary heat input, recovery, and dissipation. Tubular heat exchangers with unconventionally small tube sizes (tube diameters less than 5 mm) are promising components for supercritical CO 2 cycles and potentially provide excellent structural stability with wide scope of application. This paper provides essential design and fabrication guidelines for a compact shell-and-tube heat exchanger with microtubes (with an inner diameter equal to 1.75 mm). A heat exchanger test rig is used to evaluate the thermohydraulic performance of this heat exchanger with supercritical CO 2 and air as working fluids. Thermohydraulic data are reported for more than forty sets of experiments with varying Reynolds numbers for shell and tube flows. Critical performance metrics are calculated from the data and compared with predictions from a previously described numerical model. The average deviations between the experimental and model results fall within 10% for all critical metrics. This excellent agreement validates the numerical model for supercritical CO 2 heat exchanger optimization and scale-up.

42 ENGINEERING↗

High effectiveness liquid droplet/gas heat exchanger for space power applications

A high-effectiveness liquid droplet/gas heat exchanger (LDHX) concept for thermal management in space is described. Heat is transferred by direct contact between fine droplets (approximately 100-300 microns in diameter) of a suitable low vapor pressure liquid and an inert working gas. Complete separation of the droplet and gas media in the zero-g environment is accomplished by configuring the LDHX as a vortex chamber.The large heat transfer area presented by the small droplets permits heat exchanger effectiveness of 0.9-0.95 in a compact, lightweight geometry which avoids many of the limitations of conventional plate and fin or tube and shell heat exchangers, such as their tendency toward single point failure. The application of the LDHX in a high temperature Brayton cycle is discussed to illustrate the performance and operational characteristics of this new heat exchanger concept.

Bruckner, A. P.↗

Sockeye Heat Pipe Analysis Code Verification and Validation

Some of the most promising microreactor designs currently under development utilize heat pipe technology to transfer heat from the reactor core to the secondary side heat exchanger, due to the technology’s compactness, efficiency, passivity, and reliability. Sockeye is an engineering-scale heat pipe tool developed under the Nuclear Energy Advanced Modeling and Simulation Program to be used for the design and safety analysis of microreactors. Sockeye’s core capability lies in a 1D, two-phase, compressible flow model, used to simulate the working fluid inside the heat pipe. Sockeye is built on the Multiphysics Object-Oriented Simulation Environment framework, which allows for seamless multiphysics coupling with other Nuclear Energy Advanced Modeling and Simulation tools and can thus be used in a full-scale simulation of a microreactor assembly, which can include hundreds of heat pipes. This paper presents some initial verification and validation assessments performed for Sockeye. We demonstrate good agreement between Sockeye’s numerical results and steady-state analytic solutions for velocity and pressure drop, with differences attributable to the underlying assumptions made by the analytic solutions. We also show that Sockeye reproduces analytic predictions of key operational limits, such as the capillary limit and the sonic limit. Finally, we compare Sockeye results to experimental data for the SAFE-30 heat pipe module test.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Direct contact droplet heat exchangers for thermal management in space

A liquid droplet heat exchanger for space applications is described which transfers heat between a gas and a liquid metal dispersed into droplets. The ability of the droplet heat exchanger to transfer heat between two media in direct contact over a wide temperature range circumvents many of the material limitations of conventional tube-type heat exchangers and does away with complicated plumbing systems and their tendency toward single point failure. Droplet heat exchangers offer large surface to volume ratios in a compact geometry, very low gas pressure drop, and high effectiveness. The application of the droplet heat exchanger in a high temperature Brayton cycle is discussed to illustrate its performance and operational characteristics.

Bruckner, A. P.↗

A Mass Computation Model for Lightweight Brayton Cycle Regenerator Heat Exchangers

Based on a theoretical analysis of convective heat transfer across large internal surface areas, this paper discusses the design implications for generating lightweight gas-gas heat exchanger designs by packaging such areas into compact three-dimensional shapes. Allowances are made for hot and cold inlet and outlet headers for assembly of completed regenerator (or recuperator) heat exchanger units into closed cycle gas turbine flow ducting. Surface area and resulting volume and mass requirements are computed for a range of heat exchanger effectiveness values and internal heat transfer coefficients. Benefit cost curves show the effect of increasing heat exchanger effectiveness on Brayton cycle thermodynamic efficiency on the plus side, while also illustrating the cost in heat exchanger required surface area, volume, and mass requirements as effectiveness is increased. The equations derived for counterflow and crossflow configurations show that as effectiveness values approach unity, or 100 percent, the required surface area, and hence heat exchanger volume and mass tend toward infinity, since the implication is that heat is transferred at a zero temperature difference. To verify the dimensional accuracy of the regenerator mass computational procedure, calculation of a regenerator specific mass, that is, heat exchanger weight per unit working fluid mass flow, is performed in both English and SI units. Identical numerical values for the specific mass parameter, whether expressed in lb/(lb/sec) or kg/(kg/sec), show the dimensional consistency of overall results.

Juhasz, Albert J.↗

A Mass Computation Model for Lightweight Brayton Cycle Regenerator Heat Exchangers

Based on a theoretical analysis of convective heat transfer across large internal surface areas, this paper discusses the design implications for generating lightweight gas-gas heat exchanger designs by packaging such areas into compact three-dimensional shapes. Allowances are made for hot and cold inlet and outlet headers for assembly of completed regenerator (or recuperator) heat exchanger units into closed cycle gas turbine flow ducting. Surface area and resulting volume and mass requirements are computed for a range of heat exchanger effectiveness values and internal heat transfer coefficients. Benefit cost curves show the effect of increasing heat exchanger effectiveness on Brayton cycle thermodynamic efficiency on the plus side, while also illustrating the cost in heat exchanger required surface area, volume, and mass requirements as effectiveness is increased. The equations derived for counterflow and crossflow configurations show that as effectiveness values approach unity, or 100 percent, the required surface area, and hence heat exchanger volume and mass tend toward infinity, since the implication is that heat is transferred at a zero temperature difference. To verify the dimensional accuracy of the regenerator mass computational procedure, calculation of a regenerator specific mass, that is, heat exchanger weight per unit working fluid mass flow, is performed in both English and SI units. Identical numerical values for the specific mass parameter, whether expressed in lb/(lb/sec) or kg/ (kg/sec), show the dimensional consistency of overall results.

Juhasz, Albert J.↗

High effectiveness liquid droplet/gas heat exchanger for space power applications

A high-effectiveness liquid droplet/gas heat exchanger (LDHX) concept for thermal management in space is described. Heat is transferred by direct contact between fine droplets (approx. 100 to 300 micron diameter) of a suitable low vapor pressure liquid and an inert working gas. Complete separation of the droplet and gas media in the zero-g environment is accomplished by configuring the LDHX as a vortex chamber. The large heat transfer area presented by the small droplets permits heat exchanger effectiveness of 0.9 to 0.95 in a compact, lightweight geometry which avoids many of the limitations of conventional plate and fin or tube and shell heat exchangers, such as their tendency toward single point failure. The application of the LDHX in a high temperature Bryaton cycle is discussed to illustrate the performance and operational characteristics of this heat exchanger concept.

Bruckner, A. P.↗