Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “communication protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Control And Optimization Modular Modeling Application For Nuclear Deployment

The purpose of the COMMAND code is to provide a flexible, scalable tool for use in developing, integrating, and testing the technologies necessary for achieving autonomous operations of advanced nuclear reactors. The code enables users to efficiently implement custom simulations and experiments by combining key methods from different software modules. These modules are focused on: modeling and simulation tools, such as nuclear simulation tools used for high-fidelity modeling (e.g., Reactor Excursion and Leak Analysis Program [RELAP5-3D] and Monte Carlo N-Particle [MCNP]); machine learning and optimization tools (e.g., anomaly detection and data-driven modeling techniques); advanced control in its digital, high-performance, and supervisory control forms (e.g., proportional integral derivative (PID) control and model predictive control (MPC); and integration with hardware through industrial communication protocols. To ensure flexibility and scalability, COMMAND was designed to be both modular—the software “pieces” all inherit from generic building blocks and can be combined and connected to create complicated simulations—and high performing—designed for parallel processing, enabling simulations and experiments to take advantage of multi-core computers, servers, and nodes. The code is written in the Python programming language due to the language's popularity, active community, and open-source and cross-platform nature. Maintaining consistency with other simulation tools used within the nuclear energy community, users implement simulations and experiments through text input files, which define components, parameters, connections, etc., through lines of text. Given that COMMAND is written in Python, these input files are native Python scripts, and so use the standard Python structure and formatting. This also enables users to take advantage of Python's extensive package library to develop custom capabilities for their specific use cases.

Faber, Jacob [Idaho National Laboratory (INL), Ida↗

EnergyPlus Model Context Protocol Server (EnergyPlus-MCP) v0.1

EnergyPlus-MCP is the first open-source Model Context Protocol server specifically designed for EnergyPlus building energy simulation. This innovative software enables AI assistants and other applications to interact programmatically with EnergyPlus through a standardized, secure interface, eliminating traditional technical barriers in building energy modeling. The software provides specialized tools across five functional domains: server management, model configuration and loading, comprehensive building component inspection, systematic model modification, and simulation execution with results visualization. Key features include automated HVAC system discovery and topology mapping, advanced schedule analysis, intelligent model validation, and interactive visualization capabilities. EnergyPlus-MCP's layered architecture ensures robust separation between protocol communication and domain expertise, enabling scalable deployment across organizations, educational institutions, and research teams. Unlike direct LLM approaches that suffer from inconsistent results and security gaps, EnergyPlus-MCP provides validated, reliable interactions while maintaining scientific rigor. This democratizes sophisticated building energy analysis, making EnergyPlus accessible to broader audiences through conversational interfaces and streamlined workflows.

Li, Han [Lawrence Berkeley National Laboratory (LB↗

Dual Event Generator Support (dual-evg-support) v1.0

Dual Event Generator Support is an EPICS support module that implements the communication protocol to interface with the Dual EVG projects (already open source at https://github.com/BerkeleyLab/LBNL-Dual-EVG).

Russo, Lucas [Lawrence Berkeley National Laborator↗

Building a controlled-NOT gate between polarization and frequency

By harnessing multiple degrees of freedom (DoFs) within a single photon, controlled quantum unitaries, such as the two-qubit controlled-NOT ( cnot ) gate, play a pivotal role in advancing quantum communication protocols such as dense coding and entanglement distillation. In this work, we devise and realize a cnot operation between polarization and frequency DoFs by exploiting directionally dependent electro-optic phase modulation within a fiber Sagnac loop. Alongside computational basis measurements, we validate the effectiveness of this operation through the synthesis of all four Bell states in a single photon, all with fidelities greater than 98%. This demonstration opens new avenues for manipulating hyperentanglement across these two crucial DoFs, marking a foundational step toward leveraging polarization-frequency resources in fiber networks for future quantum applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field Demonstration of the Brick Ontology to Scale up the Deployment of ASHRAE Guideline 36 Control Sequences

Many commercial buildings have a vast network of sensors as part of their building automation systems (BAS) that allows opportunities for energy consumption and cost savings by deploying advanced control sequences. However, this resource is often underutilized since BAS are typically programmed with simple control sequences with limited potential to deliver on these opportunities. The recent availability of ASHRAE Guideline 36 (G36) with advanced HVAC control sequences supports control retrofits in existing buildings to unlock much of the savings potential. However, barriers such as the lack of standard naming convention of building assets and data points, proprietary equipment and BAS, and the inherent uniqueness of buildings and their systems prevent building stakeholders from adopting any “plug-and-play” implementation of G36. Instead, control vendors must often undertake the manual and labor-intensive point mapping process to identify a data stream’s functional and spatial relationship within the HVAC system along with other relevant contexts and map it to the new control sequences. The vendor must carry out the point mapping process in each individual building since the mapping is unlikely to port over to another building. Even for the same building, the point mapping process can occur multiple times if various control vendors implement different control retrofits and/or multiple control retrofits happen over the lifecycle of the building. Then, there is the likelihood that G36 control sequences are programmed uniquely to the building, preventing the same implementation from being reused in another. Therefore, this paper presents a field demonstration of how we leveraged the Brick ontology with BACnet, OpenBuildingControl’s Control Description Language (CDL), and open-source support tools to implement scalable and portable advanced building controls. These tools provide standardized semantic descriptions and relationships of the building’s assets and data points (Brick), standardized communication protocol to read from and write to the building’s BAS (BACnet), and standardized code implementations (CDL) of standardized advanced control strategies (G36). We implemented G36’s hot water supply temperature setpoint reset in a Berkeley, CA building for this field demonstration. This field demonstration aims to show how integrating these tools may streamline the deployment of advanced control sequences such as G36 in a consistent manner regardless of differences found across buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Blockchain based Communication Architectures with Applications to Private Security Networks

Existing communication protocols in high consequence security networks are highly centralized. While this naively makes the controls easier to physically secure, external actors require fewer resources to disrupt the system because there are fewer points in the system can be destroyed or interrupted without the entire system failing. We present a solution to this problem using a proof-of-work-based blockchain implementation built on MultiChain. We construct a test-bed network containing two types of data input: visual imagers and microwave sensor information. These data types are ubiquitous in perimeter intrusion detection security systems and allow a realistic representation of a real-world network architecture. The cameras in this system use an object detection algorithm to nd important targets in the scene. The raw data from the camera and the outputs from the detection algorithm are then placed in a transaction on the distributed ledger. Similarly, microwave data is used to detect relevant events and are placed in a transaction. These transactions are then bundled into blocks and broadcast to the rest of the network using the Bitcoin-based MultiChain protocol. We develop five tests to examine the security metrics of our network. We performed the five security metric test using different sized networks from 7 to 39 nodes to determine how the metrics scale with respect to size. We nd that when compared to a centralized architecture our implementation provides a resiliency increase that is expected from a blockchain-based protocol without slowing the system so much that a human operator would notice. Furthermore, our approach is able to detect tampering in real time. Based on these results, we theorize that security networks in general could use a blockchain-based approach in a meaningful way.

97 MATHEMATICS AND COMPUTING↗

Recommendations for Distributed Energy Resource Access Control

Cybersecurity for internet - connected Distributed Energy Resources (DER) is essential for the safe and reliable operation of the US power system. Many facets of DER cybersecurity are currently being investigated within different standards development organizations, research communities, and industry committees to address this critical need. This report covers DER access control guidance compiled by the Access Controls Subgroup of the SunSpec/Sandia DER Cybersecurity Workgroup. The goal of the group was to create a consensus - based technical framework to minimize the risk of unauthorized access to DER systems. The subgroup set out to define a strict control environment where users are authorized to access DER monitoring and control features through three steps: (a) user is identified using a proof-of-identity, (b) the user is authenticated by a managed database, (c) and the user is authorized for a specific level of access. DER access control also provides accountability and nonrepudiation within the power system control environment that can be used for forensic analysis and attribution in the event of a cyber-attack. This paper covers foundational requirements for a DER access control environment as well as offering a collection of possible policy, model, and mechanism implementation approaches for IEEE 1547-mandated communication protocols.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

ManiPIO - Manipulate Process I/O for Industrial Control Systems

The Manipulate Process Input/Output (IO) (ManiPIO) program allows users to develop custom scripts to execute Industrial Control System (ICS) manipulations. The driving development principles of ManiPIO are modularity and ease of use. Currently the program can utilize the Modbus TCP communication protocol, but its modular programming structure allows other protocols to be quickly and easily implemented. Additional functionality can be added to fit specific user needs, due to the usage of Python classes. The input configuration instructions are human readable and allow the user to create a complex series of control system manipulations.

97 MATHEMATICS AND COMPUTING↗

Distributed Energy Resource Cybersecurity Standards Development [Final Report]

Currently, the solar industry is operating with little application-specific guidance on how to protect and defend their systems from cyberattacks. This 3-year Department of Energy (DOE) Solar Energy Technologies Office-funded project helped advance the distributed energy resource (DER) cybersecurity state-of-the-art by (a) bolstering industry awareness of cybersecurity concepts, risks, and solutions through a webinar series and (b) developing recommendations for DER cybersecurity standards to improve the security performance of DER products and networks. Drafting DER standards is a lengthy, consensus-based process requiring effective leadership and stakeholder participation. This project was designed to reduce standard and guide writing times by creating well-researched recommendations that could act as a starting place for national and international standards development organizations. Working within the SunSpec/Sandia DER Cybersecurity Workgroup, the team produced guidance for DER cybersecurity certification, communication protocol standards, network architecture s, access control, and patching. The team also led subgroups within the IEEE P 1547.3 Guide for Cybersecurity of Distributed Energy Resources Interconnected with Electric Power Systems committee and pushed a draft to ballot in October 2021.

14 SOLAR ENERGY↗

Barriers to Broader Utilization of Fault Detection Technologies for Improving Residential HVAC Equipment Efficiency

Faults in residential heating, ventilating, and air conditioning (HVAC) equipment may occur due to poor installation practices or develop over time, and these faults can negatively impact system efficiency, thermal comfort, and equipment lifespan. Automated fault detection and diagnostic (AFDD) technologies identify energy wasting HVAC faults, such as low indoor airflow and improper refrigerant charge, and guide technicians in improving system efficiency. For residential HVAC, AFDD consists of a range of fault detecting and diagnostic capabilities, sensor configurations, and target applications. AFDD technology can either be permanently installed by the original equipment manufacturer (OEM) using embedded sensors or as an add-on product either during or after installation. Additionally, several advanced installation tools and refrigerant gauge sets include AFDD features for temporary use during equipment installation and tune-ups. Some technologies can detect a fault but have limited diagnostic capabilities. For example, a single-point measurement from the home's thermostat or energy monitor can provide certain fault detection capability by analyzing the equipment runtime or energy consumption. These technologies, though limited at determining the cause of a given fault, may have significant energy savings potential due to their low cost and prevalence in the residential HVAC market. Despite the potential benefits, fault detection technologies face many technical and market barriers preventing broad adoption. Beyond the cost barriers due to the added sensor requirements and technology development, fault detection technologies face many implementation and adoption barriers such as installer training, customer awareness, standardized communication protocols, and methods of test for evaluating accuracy. The purpose of this whitepaper is to characterize market and technical barriers impeding broader utilization of fault detection technology for residential HVAC energy efficiency applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

State of Common Grid Services Definitions

This document is prepared as part of the Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) 2.5.2 project, whose goal is to develop and socialize a common set of grid service definitions relevant to grid-related interactions with distributed energy resources (DER: responsive generation, storage, and loads), and to advance the concept and requirements of the Energy Services Interface (ESI) to the point of launching related interface standards and guides that can be implemented in communication protocols and business process definitions. The notion of “grid services” is integral to the definition of an ESI because a key principle of the ESI is that it permits coordination between grid operators and DER facilities in a way that is service-oriented, with an understanding of performance expectations. This document reviews the current state of grid service definitions, including those actively used in the market today as well as new services that have been proposed for future implementation. The document describes grid services used in transmission as well as distribution systems. In defining grid services, this document also distinguishes between two fundamental concepts: an “operational objective” and a “grid service,” which describes a generator’s or customer’s expected physical performance in delivering power to or consuming power from the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CRADA Number NFE-20-08292 with Quantum Lock Technologies LLC (CRADA Final Report)

At Quantum Lock Technologies, our mission is to use future-proof hardware and software to bridge the gap between physical access control and cyber security. Physical security includes access to doors, lockboxes/containers, and machinery/robots. Connecting physical access control to the cloud allows for remote detection, fast ledger updates, and mobile or remote access. However, this also opens physical security up to the world of cyber-attacks. At Quantum Lock, we use quantum random number generation to generate completely random and unpredictable digital keys to be used by connected equipment in a facility. This quantum technology is then paired with end-to-end encryption and a one-time-key communication protocol to ensure the highest level of security. Through the Innovation Crossroads program at Oak Ridge National Laboratory, we have developed benchtop prototypes of our technology, connected with utility boards as our first target customers, and prepared for our first pilot with customers (target end of summer 2022).

97 MATHEMATICS AND COMPUTING↗

Common Grid Services: Terms and Definitions Report

This document is prepared as part of the Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) 2.5.2 project, whose goal is to develop and socialize a common set of grid service definitions relevant to grid-related interactions with distributed energy resources (DER: responsive generation, storage, and loads) and to advance the concept and requirements of the Energy Services Interface (ESI) to the point of launching related interface standards and guides that can be implemented in communication protocols and business process definitions. The notion of grid services is associated with the definition of an ESI because a key principle of the ESI is that it permits coordination between grid operators and DER facilities in a way that is service-oriented with an understanding of performance expectations. The project investigated the current state of North American grid service definitions from various market operators and utilities, as well as the Federal Energy Regulatory Commission and the North American Electric Reliability Corporation, actively used today (Liu et al. 2022). This document builds on that work to propose terms and definitions for a set of grid service types that address operational objectives commonly found in power system operations. These grid service types derive from existing grid services used in bulk electric market operations, recognizing that each operational authority uses somewhat different names with variations on service performance parameters. Finding commonality at the wholesale or bulk system operation level will hopefully engender progress in seeking agreement on grid services for DER engagement at the distribution level in the emerging retail marketplace.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Radiation-Hardened GaN-Based Wireless Communications Architectures for Terrestrial Nuclear Reactor Sensing and Instrumentation

Wireless technologies have become increasingly common in applications, ranging from close proximity inductive communication links in medical devices to short-range Bluetooth and WiFi communications and longer-range cellular communications. Nonetheless, these technologies are unsuitable for use in or around nuclear reactors due to the extreme radiation and temperatures inherent in these environments and their associated significant degradative effects on electronics hardware. However, recent work in wide bandgap– based electronics has shown promise for gallium nitride (GaN) as an emerging technology for the realization of practical wireless communications systems for use in harsh environments. This report presents initial progress on the development of wireless communications architectures designed specifically for nuclear reactor application, based on inherently radiation-hardened (rad-hard) GaN technology. Prior work on rad-hard analog communications topologies is reviewed, and several digital modulation and encoding schemes that utilize GaN-based electronics devices are newly proposed for application in reactor environments. Continuous-time and discrete-time system simulations were performed, and results are presented for the preliminary transmitter and receiver designs, respectively. In addition, an overview of a software-defined radio testbed, designed for communications protocol development, is provided. Future work will focus on implementing candidate radiation-resistant wireless architectures using a research AlGaN/GaN high electron mobility transistor (HEMT) integrated circuit process, which is available at the Ohio State University, and irradiation studies will be carried out to assess the true potential of this technology for reactor application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Large-Scale Hydrogen Storage Cyber Risk Assessment

Hydrogen storage systems may become more widely deployed throughout the country, and so it is possible that individual and interconnected systems will be exposed to cyber-attacks. These events can cause physical and financial harm to employees, people in the vicinity of the facility, and the company that owns the facility. The two main ways bad actors may access information or control from a hydrogen storage facility are through information technology and operations technology devices, the former of which refers to data and information from networked devices and the latter of which refers to onsite controls for the physical system. Both types of entryways into the system should be considered when companies conduct cyber risk assessments and when regulators develop or revise relevant codes and standards. This report analyzes cybersecurity risks associated with a generic hydrogen storage system by outlining the system's purpose and the importance of its cybersecurity. The hydrogen storage system architecture and communication protocols are provided to understand potential cyber vulnerabilities. Later, an event tree analysis is performed on hydrogen operation to identify system weaknesses by outlining potential attack scenarios. This report also identifies critical cyber assets related to different hydrogen operations followed by an examination of potential threats, and the impact of cyber assets on those operational assets.

08 HYDROGEN↗

Large-Scale Hydrogen Storage Cyber Risk Assessment

Hydrogen storage systems are becoming more widely deployed throughout the country, and as their presence continues to grow, it is possible that individual and interconnected systems will be exposed to cyber-attacks. These events can cause physical and financial harm to employees, people in the vicinity, and to the company that owns the facility. The two main mechanisms malicious actors may access information or control from a hydrogen storage facility are through information technology and operations technology devices, the former of which refers to data and information from networked devices and the latter of which refers to onsite controls for the physical system. Both types of entryways into the system should be considered when facility managers conduct cyber risk assessments and when regulators develop or revise relevant codes and standards. This report analyzes cybersecurity risks applicable to a wide variety of hydrogen storage systems by outlining the system's purpose and the importance of its cybersecurity. The hydrogen storage system architecture and communication protocols are provided to understand potential cyber vulnerabilities. Later, an event tree analysis is performed on hydrogen operation to identify system weaknesses by outlining potential attack scenarios. This report also identifies critical cyber assets related to different hydrogen operations followed by an examination of potential threats, and the impact of cyber assets on those operational assets.

08 HYDROGEN↗

EV Charging Infrastructure Energization An Overview of Approaches for Simplifying and Accelerating Timelines to Processing EV Charging Load Service Requests

The United States has seen significant growth in electric vehicle (EV) adoption, leading to increased demand for EV charging infrastructure. Over the past decade, EV charging infrastructure site developers, site hosts, and electric distribution utilities have navigated the process to integrate chargers onto the electric grid. Site developers and site hosts have raised the alarm that the integration process for high-powered EV charging projects does not meet the needs of the EV market for timeliness or cost. High-powered charging stations typically require a load service request or an agreement with the local utility to connect to the grid. The process of energizing a new high-powered charging site can be complex and time-consuming, often taking up to 2 years. This timeline is the result of current utility energization processes having been designed for construction projects that take longer to build (i.e., buildings). The specific challenges stem from various factors, including compartmentalization in application processes, the integration of EV charging process approvals with other distributed energy resources (DERs), and the need to ensure grid reliability. The energization process needs to evolve to meet the growing demand for high-powered EV charging. This white paper compiles information gathered through various conversations with key stakeholders, including utilities, utility regulators, EV charging operators, site developers, and authorities having jurisdiction (AHJ) as well as through an extensive literature review. This document identifies the challenges and provides potential solutions to streamline the process of connecting EV charging infrastructure to the power grid in the United States, serving as a starting point for future conversations around these solutions. The solutions noted in this white paper require collaborative efforts among utilities, regulators, and EV charging infrastructure developers to streamline the grid connection process for EV charging infrastructure. They are broadly organized into four areas: 1. Increase data access and transparency: Develop automated load service request tools, integrate hosting capacity and load service request analyses, incorporate EV adoption forecasts, and provide transparency on the processing queue. 2. Improve energization processes and timing: Create fast-track options based on prescreening criteria, provide flexibility or phased approvals in the load service request/interconnection process, build internal knowledge within utilities about EV charging technologies, and provide standardized workforce training. 3. Promote economic efficiency: Right size distribution components to accurately reflect the load requirements of EV charging infrastructure, make proactive investments in grid infrastructure based on EV adoption forecasts and growth projections, and consider energy equity and environmental justice factors such as equitable access to EV charging when planning infrastructure. 4. Improve grid reliability and resilience: Use load management/power control systems (PCS) at EV charging stations, adopt and implement harmonized standards for communication protocols and information models between the EV charging and grid control infrastructure, and address cybersecurity considerations by implementing robust security measures and standards for EV charging infrastructure—with particular emphasis on clarifying the security requirements for the interface to the grid. The objective of the solutions proposed in this white paper is to accelerate the timeline and decrease costs associated with connecting EV charging infrastructure to the grid. Electric utilities, utility regulators, EV charging infrastructure developers, and site hosts will first need to understand which solutions are available in their service territory, and if warranted, which combination of solutions would support their specific needs. Through the successful implementations of solutions at scale detailed here, industry will demonstrate a new and innovative ecosystem where timely deployment and energization of EV charging infrastructure with greater grid resiliency and reliability is a reality.

24 POWER TRANSMISSION AND DISTRIBUTION↗