Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Prediction of the influence of the heat generated by viscous friction on the efficiency of chromatography columns

The combination of the heat balance in a chromatographic column percolated by a stream of mobile phase and of the model of band migration under linear conditions along such a column permits the calculation of the axial and radial temperature distributions in the column, of the elution band profiles, and of the column efficiency under different sets of experimental conditions. The calculated results are always consistent with the experimental results published by different groups and often in good quantitative agreement. Minor discrepancies arise from difficulties in deriving precise estimates of the heat transfers from the column due to the massive endfittings of the column and to uncontrolled heat transfer from the column tube to ambient air.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A protocol for the measurement of all the parameters of the mass transfer kinetics in columns used in liquid chromatography

Band broadening in chromatography results from the combination of the dispersive effects that are associated with the different steps involved in the migration of compound bands along the column. These steps include longitudinal diffusion, trans-particle mass transfer, external film mass transfer, overall eddy diffusion, including trans-column, short-range inter-channel, trans-channel eddy diffusion, and the possible, additional mass transfer contributions arising from heat friction and the thermal heterogeneity of the column. We describe a series of experiments that provide the data needed to determine the coefficients of the contributions to band broadening of each one of these individual mass transfer steps. This specifically designed protocol can provide key information regarding the kinetic performance of columns used in liquid chromatography and explain why different columns behave so differently. The limitations, accuracy and precision of these methods are discussed. Further avenues of research that could improve the characterization of the mass transfer mechanisms in chromatographic columns, possibly contributing to the development of better columns, are suggested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of thermal processes in very high pressure liquid chromatography for column immersed in a water bath: Application of the selected models

Currently, chromatographic analyses are carried out by operating columns packed with sub-2 {micro}m particles under very high pressure gradients, up to 1200 bar for 5 cm long columns. This provides the high flow rates that are necessary for the achievement of high column efficiencies and short analysis times. However, operating columns at high flow rates under such high pressure gradients generate a large amount of heat due to the viscous friction of the mobile phase stream that percolates through a low permeability bed. The evacuation of this heat causes the formation of significant or even large axial and radial gradients of all the physico-chemical parameters characterizing the packing material and the mobile phase, eventually resulting in a loss of column efficiency. We previously developed and successfully applied a model combining the heat and the mass balances of a chromatographic column operated under very high pressure gradients (VHPLC). The use of this model requires accurate estimates of the dispersion coefficients at each applied mobile phase velocity. This work reports on a modification of the mass balance model such that only one measurement is now necessary to accurately predict elution peak profiles in a wide range of mobile phase velocities. The conditions under which the simple equilibrium-dispersive (ED) and transport-dispersive (TD) models are applicable in VHPLC are also discussed. This work proves that the new combination of the heat transfer and the ED model discussed in this work enables the calculation of accurate profiles for peaks eluted under extreme conditions, like when the column is thermostated in a water bath.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COMPARISONS OF CRYSTALLINE SILICOTITANATE AND RESORCINOL FORMALDEHYDE MEDIA FOR CESIUM REMOVAL BY IN-TANK COLUMN PROCESSING

Chemical and thermal performance of crystalline silicotitanate (CST) and resorcinol-formaldehyde (RF) ion exchange media were predicted for column configurations designed for installation in high level waste tanks and intended for cesium removal from radioactive waste supernates. Modeling predictions for the processing of a known Savannah River Site tank waste composition were generated. In a two column configuration under presumed nominal operating conditions (432 gallon packed bed, 10 gpm liquid flow, 25 C, 45 nCi/g average breakthrough limit) with lead/lag column rotation between processing cycles, approximately two cycles were predicted to treat 1,000,000 gallons of radioactive waste with CST as compared to three cycles predicted for RF. However, this processing mode was shown to be highly unfavorable for RF due to the fact that the lead column is unnecessarily exposed to large radiation doses during movement of the cesium mass transfer zone into the lag column. Thermal modeling calculations indicated that maximum temperatures within stagnant, packed CST and RF columns containing the highest anticipated cesium loading and no active cooling will reach 128 and 78 C, respectively, within 6 days. Active cooling maintains the cesium-saturated CST and RF columns below 88 and 41 C, respectively, under stagnant flow conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A RISING COOL COLUMN AS A SIGNATURE OF HELICAL FLUX EMERGENCE AND FORMATION OF PROMINENCE AND CORONAL CAVITY

Continuous observations were performed of a quiescent prominence with the Solar Optical Telescope on board the Hinode satellite on 2006 December 23 and 24. A peculiar slowly rising column of {approx}10{sup 4} K plasma develops from the lower atmosphere during the observations. The apparent ascent speed of the column is 2 km s{sup -1}, while the fine structures of the column exhibit much faster motion of up to 20 km s{sup -1}. The column eventually becomes a faint low-lying prominence. An overlying coronal cavity associated with the appearance of the column seen in the X-ray and EUV moves upward at {approx}5 km s{sup -1}. We discuss the relationship between these episodes and suggest that they are due to the emergence of a helical flux rope that undergoes reconnection with lower coronal fields, possibly carrying material into the coronal cavity. Under the assumption of the emerging flux scenario, the lower velocity of 2 km s{sup -1} and the higher one of 20 km s{sup -1} in the column are attributed to the rising motion of the emerging flux and to the outflow driven by magnetic reconnection between the emerging flux and the pre-existing coronal field, respectively. The present paper gives a coherent explanation of the enigmatic phenomenon of the rising column with the emergence of the helical rope and its effect on the corona. We discuss the implications that the emergence of such a helical rope has on the dynamo process in the convection zone.

79 ASTRONOMY AND ASTROPHYSICS↗

EVIDENCE OF CONTRIBUTION OF INTERVENING CLOUDS TO GAMMA-RAY BURST'S X-RAY COLUMN DENSITY

The origin of excess of X-ray column density with respect to optical extinction in gamma-ray bursts (GRBs) is still a puzzle. A proposed explanation of the excess is the photoelectric absorption due to the intervening clouds along a GRB's line of sight. Here, we test this scenario by using the intervening Mg II absorption as a tracer of the neutral hydrogen column density of the intervening clouds. We identify a connection between the large X-ray column density (and large column density ratio of log (N{sub H,X}/N{sub H{sub I}})∼0.5) and large neutral hydrogen column density probed by the Mg II doublet ratio (DR). In addition, GRBs with large X-ray column density (and large ratio of log (N{sub H,X}/N{sub H{sub I}})>0) tend to have multiple saturated intervening absorbers with DR < 1.2. These results therefore indicate an additional contribution from the intervening system to the observed X-ray column density in some GRBs, although the contribution from the host galaxy alone cannot be excluded based on this study.

79 ASTRONOMY AND ASTROPHYSICS↗

Plant-Scale Concentration Column Designs for SHINE Target Solution

Argonne is assisting Morgridge Institute for Research (MIR) in their efforts to develop SHINE, an accelerator-driven process that will utilize a uranyl-sulfate solution for the production of fission product Mo-99. An integral part of the process is the development of a column for the separation and recovery of Mo-99 followed by a concentration column to reduce the product volume from 15–25 L to less than 1 L. Argonne has collected data from batch studies and breakthrough column experiments to utilize the VERSE (Versatile Reaction Separation) simulation program (Purdue University) to design plant-scale product concentration processes. Plant-scale columns for 2, 4, and 6 hr loading times were designed for separation of Mo-99 from 130 g-U/L uranyl-sulfate solution. The Mo-99 product solution volumes from the recovery of Mo-99 from 260 L of uranyl sulfate are 23.5, 17.6, and 14.5 L for the 2, 4, and 6 hr loadings, respectively; the resulting Mo concentration in 0.1-M NaOH is 2.34 × 10 -2 , 3.13 × 10 -2 , and 3.81 × 10 -2 mM, respectively. The resulting product can be acidified to pH 2 using nitric acid and passed through a concentration column to reduce volume to less than 1 L. Concentration column designs have been generated for each of the three process scenarios (2, 4, and 6 hr). The plant-scale concentration column designs assume loading temperature of 80°C.

Stepinski, Dominique C.↗

Final Technical Report: Moving ASR Cloud Microphysical Retrievals Beyond the Vertical Column

Clouds of all types play important roles in atmospheric heating, surface heating and emission of radiation, hence energy, to space. Clouds not only affect atmospheric heating via their impacts on solar and terrestrial radiation, they also release kinetic energy to the atmosphere when they form and they extract kinetic energy from the atmosphere when they evaporate. To understand the impacts of clouds on weather and climate, one must be able to make accurate observations of the amount of water associated with them and the impact of this water on atmospheric and surface heating rates. One important cloud type is liquid water clouds. Liquid clouds are often found in the boundary layers of Earth at altitudes from just above the surface to approximately 2000 m above it, at a variety of temperatures, including temperatures below the freezing point of liquid water (0 °C). As a result, they are important constituents over the world’s oceans as well as over cold, ice-covered surfaces such as in the Arctic. Observationally estimating the total amount of liquid contained in a column through a liquid water cloud can now be accomplished to acceptable accuracies (except for the thinnest, lowest liquid containing clouds) using instruments called passive microwave radiometers. However, observationally determining the spatial distribution of liquid within these columns has proven to be difficult. The focus of this project was on the application of two radars operating at two different frequencies to retrieve the distribution of liquid water within columns passing through liquid water clouds. Motivation in this project for using two different radars operating at different frequencies is that as overlapping (in space) beams from the two radars pass through the same column of liquid water cloud absorption of power from one beam (the 94-GHz beam) is greater than absorption of power from the other beam (the 35-GHz beam). Therefore, the difference in returned powers between the two radar beams with distance from the radars is proportional to the amount of liquid water that the two beams have passed through. Therefore, one can use the differences in power between the two beams with distance through a liquid water cloud to determine the distribution of liquid water throughout the cloud. The two radars used in this study are the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Program Ka-band Scanning ARM Cloud Radar (Ka-SACR) and the W-band Scanning ARM Cloud Radar (W-SACR). When this projected started in 2013, the Ka- and W-band SACRs were new technology, state-of-the-art sensors. To put together a sufficiently diverse and big set of test cases for the study, data from the SACRs deployed to NSA, SGP, TCAP and MAGIC were used, leading to a test set composed of 65 hours of suitable data spread over approximately 17 case study days. Using the Ka- and W-band SACR data from the case study periods, vertical distributions of liquid water content through liquid water clouds were retrieved. Because there are no other data sets with which to compare the retrievals, distributions of liquid water through a column were summed and compared to the total amounts of liquid water obtained by retrievals applied to passive microwave radiometer observations. The total amounts of liquid water (in units of millimeters, or the thickness in millimeters of the total liquid water in a vertical column if allowed to pool at the bottom of the column) between the two retrievals agreed to within 0.060 mm with a standard deviation of 0.31 mm, or to within 0.016 mm with a standard deviation of 0.12 mm once outliers were removed. The standard deviation of 0.12 mm was fairly independent of the total amount of liquid water in the clouds, indicating that retrieval errors were larger for clouds with smaller amounts of liquid in them. Errors in the retrieved total amounts of liquid were also found to be sensitive to the a priori information that was fed into the retrieval approach. Overall, standard deviations of 0.12 mm are sufficient for some cloud studies but for radiation studies standard deviations on the order of 0.02 mm need to be achieved for clouds with the lowest amounts of liquid water. Many modifications to the retrieval approach were tested subsequently in an attempt to reduce the standard deviations relative to the radiometer retrievals below 0.12 mm but none of them worked reliably. We decided to wait until the DOE ARM Program deployed its second generation SACR2s to its NSA and ENA sites for further retrieval evaluation. The SACR2s were engineered to better synchronize data between the Ka- and W-band radars, reducing potential sources of noise for radar retrieval of liquid water distributions within clouds. The SACR2s have improved in reliability recently and the system deployed to ENA is best positioned to provide the data to advance research on this path. This will be an ongoing research activity beyond the project because of the promise in SACR2 data from the DOE ARM ENA Facility.

58 GEOSCIENCES↗

Chromatographic Modeling of 1-Foot Detritiation Test Column Results for the Optimization of Regeneration Time

This report documents the methods and results of a modeling study on a series of data generated by 1-foot test columns for the Water Detritiation project. In order to compliment modeling work already in progress on this project, a purely empirical curve-fitting approach is used in this study to determine chromatographic performance indicators such as retention time, curve width, and the number of chromatographic stages. The data used in this study comes from four sets of chromatographic test separations performed in March through May of 2017 using 1-foot columns. All are using the same flow rates and temperature (room temperature, nominally 25 C°). The first set of data (referred to in this report as the Column 1 data) is a series of twelve breakthrough curve measurements. Prior to each of these twelve runs, the column was regenerated by flowing hydrogen gas through the column, for increasing amounts of time, ranging from 2 hours to 25 hours. The second set of data (referred to as the Column 2 data) is comprised of five measurements of breakthrough curves measured in similar fashion as the Column 1 data, across a range of regeneration times from 2 to 21 hours. The third set of data (referred to as the Purge data) is of three breakthrough curves, measured after a regeneration time of 8 hours, which takes place after a nitrogen purge of 15, 30, or 45 minutes. The fourth data set is a series of five breakthrough curve measurements using a 2 nd batch of stationary phase, taken after regeneration times ranging from 2 to 20 hours. The overall modeling approach is as follows. First, the data is pre-processed for formatting, artifact removal, and is normalized. The data is then fit by integrated versions of four common chromatographic models. The best model is chosen based on the predictive performance of the model, and chromatographic performance values are calculated based on the best model’s fit parameters. Each of these processes are detailed below.

42 ENGINEERING↗

Stability and dynamic analysis of a slender column with curved longitudinal stiffeners

The results of a stability design study are presented for a slender column with curved longitudinal stiffeners for large space structure applications. Linear stability analyses are performed using a link-plate representation of the stiffeners to determine stiffener local buckling stresses. Results from a set of parametric analyses are used to determine an approximate explicit expression for stiffener local buckling in terms of its geometric parameters. This expression along with other equations governing column stability and mass are assembled into a determinate system describing minimum mass stiffened column design. An iterative solution is determined to solve this system and a computer program incorporating this routine is presented. Example design problems are presented which verify the solution accuracy and illustrate the implementation of the solution routine. Also, observations are made which lead to a greatly simplified first iteration design equation relating the percent increase in column mass to the percent increase in column buckling load. From this, generalizations are drawn as to the mass savings offered by the stiffened column concept. Finally, the percent increase in fundamental column vibration frequency due to the addition of deployable stiffeners is studied.

Lake, Mark S.↗

Sources of Variability in the Stratospheric Column of Nitrogen Dioxide

Instruments such as the Global Ozone Monitoring Experiment (GOME, on the European Remote Sensing Satellite (ERS-2), launched 1995), the Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY, on ENVISAT, to be launched July 2001) and the Ozone Monitoring Instrument (OMI on EOS Aura, to be launched 2003) make measurements of the total column of NO2. There is interest in separating the stratospheric and tropospheric contributions to the column, as the tropospheric column provides a measure of pollution. We are using a 3D chemistry and transport model driven by winds from the Goddard Space Flight Center Data Assimilation System to examine variability in the stratospheric NO2 column. Model results for NOx = NO + NO2 + 2N2O5 will be shown to compare well with sunset observations from the Halogen Occultation Experiment on the Upper Atmosphere Research Satellite, and to exhibit similar temporal and spatial dependence. Partitioning between NO, NO2, and N2O5 is also shown to compare well with observations. This good agreement supports the use of simulated fields in the stratosphere to derive the tropospheric column from the total column. Preliminary comparisons of the tropospheric column with model simulations for the troposphere will also be shown.

Douglass, Anne↗

Formaldehyde Distribution over North America: Implications for Satellite Retrievals of Formaldehyde Columns and Isoprene Emission

Formaldehyde (HCHO) columns measured from space provide constraints on emissions of volatile organic compounds (VOCs). Quantitative interpretation requires characterization of errors in HCHO column retrievals and relating these columns to VOC emissions. Retrieval error is mainly in the air mass factor (AMF) which relates fitted backscattered radiances to vertical columns and requires external information on HCHO, aerosols, and clouds. Here we use aircraft data collected over North America and the Atlantic to determine the local relationships between HCHO columns and VOC emissions, calculate AMFs for HCHO retrievals, assess the errors in deriving AMFs with a chemical transport model (GEOS-Chem), and draw conclusions regarding space-based mapping of VOC emissions. We show that isoprene drives observed HCHO column variability over North America; HCHO column data from space can thus be used effectively as a proxy for isoprene emission. From observed HCHO and isoprene profiles we find an HCHO molar yield from isoprene oxidation of 1.6 +/- 0.5, consistent with current chemical mechanisms. Clouds are the primary error source in the AMF calculation; errors in the HCHO vertical profile and aerosols have comparatively little effect. The mean bias and 1Q uncertainty in the GEOS-Chem AMF calculation increase from <1% and 15% for clear skies to 17% and 24% for half-cloudy scenes. With fitting errors, this gives an overall 1 Q error in HCHO satellite measurements of 25-31%. Retrieval errors, combined with uncertainties in the HCHO yield from isoprene oxidation, result in a 40% (1sigma) error in inferring isoprene emissions from HCHO satellite measurements.

Millet, Dylan B.↗

Analysis of Satellite-Derived Arctic Tropospheric BrO Columns in Conjunction with Aircraft Measurements During ARCTAS and ARCPAC

We derive tropospheric column BrO during the ARCTAS and ARCPAC field campaigns in spring 2008 using retrievals of total column BrO from the satellite UV nadir sensors OMI and GOME-2 using a radiative transfer model and stratospheric column BrO from a photochemical simulation. We conduct a comprehensive comparison of satellite-derived tropospheric BrO column to aircraft in-situ observations ofBrO and related species. The aircraft profiles reveal that tropospheric BrO, when present during April 2008, was distributed over a broad range of altitudes rather than being confined to the planetary boundary layer (PBL). Perturbations to the total column resulting from tropospheric BrO are the same magnitude as perturbations due to longitudinal variations in the stratospheric component, so proper accounting of the stratospheric signal is essential for accurate determination of satellite-derived tropospheric BrO. We find reasonably good agreement between satellite-derived tropospheric BrO and columns found using aircraft in-situ BrO profiles, particularly when satellite radiances were obtained over bright surfaces (albedo> 0.7), for solar zenith angle < 80 and clear sky conditions. The rapid activation of BrO due to surface processes (the bromine explosion) is apparent in both the OMI and GOME-2 based tropospheric columns. The wide orbital swath of OMI allows examination of the evolution of tropospheric BrO on about hourly time intervals near the pole. Low surface pressure, strong wind, and high PBL height are associated with an observed BrO activation event, supporting the notion of bromine activation by high winds over snow.

Choi, S.↗

Spatial and Temporal Variability of Ground and Satellite Column Measurements of NO2 and O3 over the Atlantic Ocean During the Deposition of Atmospheric Nitrogen to Coastal Ecosystems Experiment

In situ measurements of O3 and nitrogen oxides (NO + NO2=NOx) and remote sensing measurements of total column NO2 and O3 were collected on a ship in the North Atlantic Ocean as part of the Deposition of Atmospheric Nitrogen to Coastal Ecosystems (DANCE) campaign in July August 2014,100 km east of the mid-Atlantic United States. Relatively clean conditions for both surface in situ mixing ratio and total column O3 and NO2 measurements were observed throughout the campaign. Increased surface and column NO2 and O3 amounts were observed when a terrestrial air mass was advected over the study region. Relative to ship-based total column measurements using a Pandora over the entire study, satellite measurements overestimated total column NO2 under these relatively clean atmospheric conditions over offshore waters by an average of 16. Differences are most likely due to proximity, or lack thereof, to surface emissions; spatial averaging due to the field of view of the satellite instrument; and the lack of sensitivity of satellite measurements to the surface concentrations of pollutants. Total column O3 measurements from the shipboard Pandora showed good correlation with the satellite measurements(r 0.96), but satellite measurements were 3 systematically higher than the ship measurements, in agreement with previous studies. Derived values of boundary layer height using the surface in situ and total column measurements of NO2 are much lower than modeled and satellite-retrieved boundary layer heights, which highlight the differences in the vertical distribution between terrestrial and marine environments.

Martins, Douglas K.↗

Radiography in High Mass X-Ray Binaries: Micro-Structure of the Stellar Wind Through Variability of the Column Density

Context. In high mass X-ray binaries, an accreting compact object orbits a high mass star, which loses mass through a dense and in homogeneous wind. Aims. Using the compact object as an X-ray backlight, the time variability of the absorbing column density in the wind can be exploited in order to shed light on the micro-structure of the wind and obtain unbiased stellar mass-loss rates for high mass stars. Methods. We developed a simplified representation of the stellar wind where all the matter is gathered in spherical “clumps” that are radially advected away from the star. This model enables us to explore the connections between the stochastic properties of the wind and the variability of the column density for a comprehensive set of parameters related to the orbit and to the wind micro-structure, such as the size of the clumps and their individual mass. In particular, we focus on the evolution with the orbital phase of the standard deviation of the column density and of the characteristic duration of enhanced absorption episodes. Using the porosity length, we derive analytical predictions and compare them to the standard deviations and coherence time scales that were obtained. Results. We identified the favorable systems and orbital phases to determine the wind micro-structure. The coherence time scale of the column density is shown to be the self-crossing time of a single clump in front of the compact object. We thus provide a procedure to get accurate measurements of the size and of the mass of the clumps, purely based on the observable time variability of the column density. Conclusions. The coherence time scale grants direct access to the size of the clumps, while their mass can be deduced separately from the amplitude of the variability. We further show how monitoring the variability at superior conjunctions can probe the onset of the clump-forming region above the stellar photosphere. If the high column density variations in some high mass X-ray binaries are due to unaccreted clumps which are passing by the line-of-sight, this would require high mass clumps to reproduce the observed peak-to-peak amplitude and coherence time scales. These clump properties are marginally compatible with the ones derived from radiative-hydrodynamics simulations. Alternatively, the following components could contribute to the variability of the column density: larger orbital scale structures produced by a mechanism that has yet to be identified or a dense environment in the immediate vicinity of the accretor, such as an accretion disk, an outflow, or a spherical shell surrounding the magnetosphere of the accreting neutron star.

stars: mass loss↗

Airborne HSRL Assessment of CALIOP Aerosol Extinction Retrievals Constrained by Column AOD

Current operational CALIOP aerosol extinction profile retrievals usually rely on accurately specifying the relationship between aerosol extinction and backscattering (i.e. lidar ratio). Uncertainties in the assigned lidar ratios are typically the largest source of systematic error (~30-50%) in the CALIOP retrievals of aerosol extinction, backscatter, and aerosol optical depth. Alternatively, column aerosol optical depth (AOD) can be used to solve the lidar equation and obtain column-equivalent lidar ratios and retrieve aerosol extinction profiles from the CALIOP attenuated backscatter profiles. These derived lidar ratios correspond to the aerosols in the altitude range from 0-7 km. We derive column-equivalent aerosol lidar ratios and aerosol extinction profiles from CALIOP attenuated backscatter profiles constrained using co-located column AODs provided by several instruments/techniques: Synergized Optical Depth of Aerosols (SODA), Ocean-Derived Column Optical Depths (ODCOD), MODIS (dark target), MODIS (Multi-Angle Implementation of Atmospheric Correction-MAIAC), and PARASOL (Generalized Retrieval of Aerosol and Surface Properties-GRASP). These various retrievals of AOD and the column-average aerosol lidar ratios and aerosol extinction profiles derived from CALIOP using these AOD constraints are evaluated using the extensive record of coincident and co-located airborne HSRL measurements of AOD, aerosol lidar ratio, and aerosol extinction profiles acquired during more than 140 HSRL underflights of CALIPSO since 2006. The HSRL technique allows for the independent measurement of extinction and backscatter without the need for external constraints or assumptions regarding the lidar ratios. Initial comparisons with these coincident HSRL aerosol extinction profiles show that the CALIOP aerosol extinction profiles retrieved using these various AOD constraints are generally in better agreement with the HSRL measurements than aerosol extinction profiles from the operational techniques. The quality of agreement depends on the accuracy and magnitude of the AOD constraint. We present these comparisons of AOD, column aerosol lidar ratio, and aerosol extinction profiles for each of the AOD constraints described above.

lidar↗

Multiphase computational fluid dynamics modeling of reacting flows in absorption columns for carbon capture

First-principles derived computational fluid dynamics (CFD) simulations have been proposed as a fundamental tool for investigating solvent-based CO 2 absorption in packed columns due to their ability to accurately represent the underlying nonlinear, multiscale dynamics. Numerous studies have previously utilized such CFD simulations to investigate hydrodynamics of columns with structured and random packings by assessing the key hydrodynamic metrics such as the interfacial and wetted areas. While mapping such metrics for different conditions is essential to the optimization of absorption columns, it is not sufficient, as the CO 2 capture rate depends also on the coupled, nonlinear dynamics from the underlying chemical reaction kinetics, thermodynamics, and heat-transfer rates. In this work, we present detailed CFD simulation results augmented by incorporating the effects of interfacial physical mass transfer of CO 2 , heat release from chemical reaction kinetics, and thermophysical property variations from resulting temperature gradients. We demonstrate the applicability of the proposed approach in numerically assessing the performance of packed columns by evaluating key hydrodynamic quantities, CO 2 absorption rates, and temperature rise in a reference column with packings that are structurally similar to the Sulzer Mellapak™ 250.Y packing, for different solvent inflow velocities and temperatures. Predictions from simulation results are found to be consistent with the trends in experimental observations from the literature, suggesting that the predictive capabilities of the simulation framework can be leveraged to guide the future development of absorber-column designs and optimized process flowsheets.

Absorption columns↗

Reproducible automated renewable column generation

Preparation of chromatographic columns requires considerable time during chemical separation procedures. Automated systems capable of repeatedly generating renewable, uniformly packed columns would find widespread use in analytical laboratories. Here, a fully automated commercial-off-the-shelf (COTS) system was utilized to pack and unpack 1 mL TEVA and UTEVA columns. To accurately determine the reproducibility of the resin load per column, studies were conducted over several weeks. Method optimization yielded an improvement in loading from 15–19% to 3–5% relative standard deviation. Furthermore, availability of automated COTS equipment capable of reproducibly generating separation columns has the potential to reduce time and costs associated with column separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗