Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Nonlinear dynamics of proton beams with hollow electron lens in the CERN high-luminosity LHC

The design stored beam energy in the CERN high-luminosity large hadron collider (HL-LHC) upgrade is about 700 MJ, with about 36 MJ in the beam tails, according to estimates based on scaling considerations from measurements at the LHC. Such a large amount of stored energy in the beam tails poses serious challenges on its control and safe disposal. In particular, orbit jitters can cause significant losses on primary collimators, which can lead to accidental beam dumps, magnet quenches, or even permanent damage to collimators and other accelerator elements. Thus, active control of the diffusion speed of halo particles is necessary and the use of hollow electron lenses (HELs) represents the most promising approach to handle overpopulated tails at the HL-LHC. HEL is a very powerful and advanced tool that can be used for controlled depletion of beam tails, thus enhancing the performance of beam halo collimation. For these reasons, HELs have been recently included in the HL-LHC baseline. In this paper, we present detailed beam dynamics calculations performed with the goal of defining HEL specifications and operational scenarios for HL-LHC. The prospects for effective halo control in HL-LHC are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam halo formation with different cathode distributions

Beam halo refers to the low-density distribution of particles extending beyond the beam core, and its generation and mitigation are important topics in particle accelerator design. Effective mitigation of beam halo is essential for the cooler design based on Energy Recovery Linac (ERL), which must deliver an electron beam with average beam current of 100 mA and a charge 1 nC per bunch. In the ERL injector and booster linacs, space charge effects are stronger due to relatively low beam energy (6 MeV). Additionally, the longer bunch length of approximately 100 ps in this regime vs the RF period of 5.08 ns makes the formation of beam halos more likely. Therefore, effective collimation of beam halo is critical to maintaining the required beam parameters. To design an effective collimation scheme, several halo distributions were generated at the cathode and used to study halo formation within the injector-merger. This paper presents different halo distributions and halo formation, providing insights on halo collimation strategy.

Accelerator Physics↗

A comprehensive final summary of the MCNP calculations performed concerning the UW 137 Cs release event

This document combines and supersedes earlier reports (e.g. LA-UR-19-32358 and LA-UR-20- 22216) that discussed MCNP-calculated conversion factors (count rate per unit activity per unit area) for collimated 2”x2” NaI detectors (Ludlum model 44-10 and Thermo model SPA3) in contact with various surfaces of interest to the University of Washington 137 Cs release event. These surfaces include: Exterior surface of round and rectangular ducts, Exterior surface of outdoor brick work, Exterior surface of cast iron pipes, Exterior surface of an O 2 filter assembly For each surface, the calculated conversion factors allowed inferences on 137 Cs activity on interior surfaces based on exterior contact measurements of the 662 keV photopeak count rate. The MCNP calculations included the effect of attached collimators (i.e. either a Pb/Sb-based Ludlum or a W-based “Rees” model) on detector response. As a consequence, the conversion factors only apply to the appropriate collimated 2”x2” NaI detector operated in pulse height analysis (PHA) mode. Other assumptions affecting the calculations and valid application of the conversion factors will be outlined below.

54 ENVIRONMENTAL SCIENCES↗

Simulations Supporting the Development of Northstar's Indirect Beam Parameters Monitoring System

NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons impinged on the molybdenum target produce bremsstrahlung X-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (and heat deposition in the target), which creates challenging requirements for the cooling of the target. The critical part of the target is the target window. It separates the high-pressure helium cooled target from the vacuum beamline and the subject of structural and thermal stress. The temperature of the target window is proportional to the energy density deposited by the beam, so it is critical to maintain the desired beam profile on the target window. The feasibility of indirectly monitoring the maximum energy density of the beam on the beam window through beam losses at the main collimator (Collimator) before the production target was verified. A model of the NorthStar beam transport line was constructed for this purpose using MAD-X and Tao/Bmad codes. Beam optics were computed for the standard operational scenario, followed by an investigation involving approximately 400 cases with parameter variations in the last tuning quadrupoles. This was done to assess the correlation between losses in the collimator and the peak energy density on the target. We developed a model to explore the potential application of Optical transition radiation (OTR) for controlling beam parameters in the NorthStar beam delivery system. This model was based on a generic formula derived from the fundamental solution of the inhomogeneous wave equation of the vector potential, and allowed us to consider various surfaces, even those with irregular or random features, using numerical integration. We applied the model to OTR generated by relativistic electrons impacting an Inconel® 718 beam window. We examined cases with different levels of the window’s surface roughness, ranging from 0.5 to 3.0 microns of root square mean (RMS) deviation. The results of the OTR simulations provided distributions of OTR photons that can be used to study the limitations of optical systems for controlling beam parameters.

43 PARTICLE ACCELERATORS↗

Optical fiber connector ferrule assembly having dual reflective surfaces for beam expansion and expanded beam connector incorporating same

An expanded beam ferrule includes a first ferrule halve having first reflective surfaces and a second ferrule halve having second reflective surfaces, which together retain optical fibers. The pair of reflective surfaces output collimated light parallel to the mid-plane of the ferrule. An external sleeve aligns the external surface of two similar ferrules, with corresponding second reflective surfaces of the ferrules facing each other. Output light from an optical fiber held in one ferrule is bent twice by the pair of reflective surfaces, with beam divergence after the first bent, and collimation after the second bent. The collimated light is transmitted to the facing second reflective surface in a facing second ferrule aligned by the sleeve, which is subject to optical reshaping in reverse to that undertaken in the first ferrule, so as to converge and focus light to input to the optical fiber held in the other ferrule.

42 ENGINEERING↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Large Area Picosecond Photodetector for Neutron Transmission Measurements at DICER at LANSCE

The Device for Indirect Capture Experiments on Radionuclides (DICER) is a new instrument that is being developed at the Los Alamos Neutron Science Center (LANSCE) to study neutron capture reactions on short-lived radionuclides. To achieve that, DICER is using an indirect technique based on measuring the neutron transmission through very small samples (0.12–1.2 mm in diameter, $\mu \text{g}$ -mg in mass). The main detection system of DICER consists of two dual photomultiplier (PMT)-based detectors which are sensitive to the scintillation light produced when neutrons interact with 6 Li glass disks. DICER is developing a new collimation system that includes a 0.1-mm collimator. In such small sizes, the need for neutron beam imaging is crucial and necessary to confirm the appropriate alignment between the irradiated sample and the neutron detectors. The large area picosecond photodetector (LAPPD) is a multichannel plate (MCP)-based photodetector, with picosecond-level timing, single-photon detection capabilities, and spatial resolution of the order of 1 mm. Coupling the LAPPD with a 6 Li glass scintillator results in a neutron imaging detector. The first irradiation of the LAPPD at DICER indicated that apart from imaging the beam, the LAPPD can be used as the main neutron detection system. Furthermore, these results were proof of principle measurements demonstrating the capabilities of the beamline, and the challenge with small samples will be addressed in the future. The first efforts and developments, including irradiations of the LAPPD and the first beam images, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and validation of a gamma-ray scanning system for measuring irradiated nuclear fuel

We report a prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Proton irradiation effects in Molybdenum-Carbide-Graphite composites

The High Luminosity upgrade of the Large Hadron Collider (HL-LHC) has prompted the investigation of novel materials for beam-intercepting devices, and in particular for the collimators responsible for protecting the machine from beam losses. The HL-LHC collimation system will inevitably experience increased levels of radiation damage and undergo changes in their crucial physio-mechanical properties. Graphite-matrix composite materials containing molybdenum carbide particles, along with small amounts of titanium carbide, were developed with the objective of enhanced in-beam performance and tested under proton irradiation. The physical degradation observed in early grades of molybdenum carbide compounds, even after modest proton fluences, has prompted the development of advanced compounds. In this work, we examine the effects of proton irradiation on the microstructural and thermophysical properties of new grades of Molybdenum-carbide-graphite compounds up to fluences of ~2 × 10 20 p/cm 2 . Here, we employ a combination of precision dilatometry and high-energy X-ray diffraction to quantify the dimensional stability and crystallographic phase evolution both pre- and post-irradiation. Our results reveal that these new compounds exhibit superior resilience to radiation damage than their predecessors.

36 MATERIALS SCIENCE↗

Neutron capture measurements at UMass lowell research reactor

A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Gate-tunable Veselago interference in a bipolar graphene microcavity

The relativistic charge carriers in monolayer graphene can be manipulated in manners akin to conventional optics. Klein tunneling and Veselago lensing have been previously demonstrated in ballistic graphene pn-junction devices, but collimation and focusing efficiency remains relatively low, preventing realization of advanced quantum devices and controlled quantum interference. Here, we present a graphene microcavity defined by carefully-engineered local strain and electrostatic fields. Electrons are manipulated to form an interference path inside the cavity at zero magnetic field via consecutive Veselago refractions. The observation of unique Veselago interference peaks via transport measurement and their magnetic field dependence agrees with the theoretical expectation. We further utilize Veselago interference to demonstrate localization of uncollimated electrons and thus improvement in collimation efficiency. Our work sheds new light on relativistic single-particle physics and provide a new device concept toward next-generation quantum devices based on manipulation of ballistic electron trajectory.

36 MATERIALS SCIENCE↗

Low-divergence femtosecond X-ray pulses from a passive plasma lens

Electron and X-ray beams originating from compact laser-wakefield accelerators have very small source sizes that are typically on the micrometre scale. Therefore, the beam divergences are relatively high, which makes it difficult to preserve their high quality during transport to applications. To improve on this, tremendous efforts have been invested in controlling the divergence of the electron beams, but no mechanism for generating collimated X-ray beams has yet been demonstrated experimentally. Here we propose and realize a scheme where electron bunches undergoing focusing in a dense, passive plasma lens can emit X-ray pulses with divergences approaching the incoherent limit. Furthermore, compared with conventional betatron emission, the divergence of this so-called plasma lens radiation is reduced by more than an order of magnitude in solid angle, while maintaining a similar number of emitted photons per electron. This X-ray source offers the possibility of producing brilliant and collimated few-femtosecond X-ray pulses for ultra-fast science, in particular for studies based on X-ray diffraction and absorption spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a narrow stopband filter for spectroscopic fast ion deuterium-alpha measurements

A new technique to attenuate the unshifted deuterium Balmer-alpha (D-alpha) emission is developed and tested for the fast ion D-alpha (FIDA) diagnostic. The unshifted D-alpha emission, at λ = 656.1 nm, is around three orders of magnitude higher than the desired FIDA emission. Blocking the strong emission feature is essential to prevent blooming and light smearing on the CCD chip and scattered light contamination. The new method is a notch filter approach that utilizes the reflection from ultra-narrow bandpass filters to block the saturating signal before it enters the spectrometer. Collimated light from the fibers is reflected off the filter at a 15° angle of incidence. Measurements show that a center wavelength transmission of 0.006 and a blocking full width at half maximum of ~ 1 nm are achieved by using a 200 μm fiber and a 20 mm focal length collimator with two filters.

47 OTHER INSTRUMENTATION↗

Observations of a plectonemic configuration in a stable magnetized plasma jet

Astrophysical jets are collimated high-speed outflows emerging from spinning and accreting matter around celestial objects and may spontaneously result from self-organized processes. Magnetic self-organization is commonly observed in laboratory plasma physics experiments; however, they require close-fitting flux conservers to constrain and stabilize the toroidal or cylindrical structures. Here we report the first observations of a long, stable, free-boundary plasma jet far from chamber walls, embedding a double-helix magnetic structure resembling a force-free plectonemic Taylor state. The jets arise from an experimental setup that mimics an accretion disk and has no close-fitting solid flux conserver. The results support the hypothesis that self-organization could be a universal, intrinsic explanation for jet formation, collimation, and stability and may help explain double-helix features in celestial observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Topography of bent crystals with microradian resolution in one dimension

Optimum performance in x-ray imaging and spectroscopy of plasmas with bent crystals is achievable only when the crystal reflects the x rays theoretically perfectly across its entire surface. However, typical thin quartz (101̄1) crystal samples kept flat by direct attachment to a flat substrate reflect 8 keV x rays differently across their surface, on a scale comparable to the ideal rocking curve. Additional processing improves the uniformity. Irradiation of flat crystals with collimated, monochromatic x rays in rocking curve topography shows such problems directly, with microradian resolution. Nonuniform x-ray reflection is more difficult to document for strongly bent crystals because, then, monochromatic, collimated x rays satisfy the Bragg condition only along a narrow stripe that may be too narrow to resolve with the available cameras. However, it can be resolved with a knife edge that moves through the reflected x rays with the necessary spatial precision as demonstrated here for a bent silicon crystal. This shows qualitatively similar imperfections in the reflection as flat quartz and as the bent quartz analyzers reported on previously with lower resolution.

Pereira, N. R. (ORCID:0000000290569596)↗

First measurements of energetic protons in Mega Amp Spherical Tokamak Upgrade (MAST-U)

First proton production rates from the d(d,p)t reaction in the Mega Amp Spherical Tokamak Upgrade (MAST-U) are measured. The data were taken during the MAST-U experimental campaign with an upgraded version of the proton detector (PD) previously used in MAST. The new detector array consists of three collimated silicon surface barrier detectors with a depletion depth of 300 μm and a collimated 120 μm thick diamond detector, mounted on the MAST-U reciprocating probe arm. This array measures the energies of unconfined energetic 3 MeV protons and 1 MeV tritons mainly produced by beam-thermal DD reactions during neutral beam injection heating. Diamond detectors have the potential to be uniquely suited to detect charged fusion products as they promise to be much more radiation resistant and much less sensitive to temperature variations compared to silicon-based detectors. Using silicon and diamond-based detectors simultaneously allowed us to directly compare the performance of these two detector types. PD particle rates measured during different plasma scenarios are presented and compared to neutron rates measured using the neutron camera upgrade and TRANSP predictions.

Instruments & Instrumentation↗

First simultaneous observation of co- and counter-current fast-ion losses in the ASDEX Upgrade tokamak

In ITER and future fusion power plants, the source of the fusion born alpha particles is almost isotropic in pitch angle, thus having co- and counter-current populations. For trapped ions, the co-current side of the orbit corresponds to its outer leg, while the counter-current side corresponds to the inner leg. Understanding the mechanisms responsible for the fast-ion losses (FILs) is critical for future magnetically confined fusion power plants. To further study the interplay of fast ions with plasma instabilities, a double pinhole collimator has been developed for a Fast-Ion Loss Detector (FILD) in the ASDEX Upgrade tokamak (AUG). This new FILD opens the operational window to simultaneous measurements of the co- and counter-current ion velocity-space. In this paper, the first results for the AUG double collimator FILD detector are shown. The commissioning of this new probe is carried out in H-mode plasmas with an on-axis magnetic field $B_0 = -2.5$ T, and a plasma current $I_{\textrm{p}} = 0.7$ MA. Simultaneous co- and counter-current FILs have been measured. Both have shown a similar dependence on Ion Cyclotron Resonance Heating (ICRH) power, where the main difference is the intensity of the losses, with the co-losses being an order of magnitude larger. Toroidal Alfvén eigenmode-coherent ICRH-only losses have been identified for the co-current ions. Additionally, the presence of Edge Localized Modes during the discharge were shown to increment Neutral Beam Injection prompt losses, while partially mitigating ICRH-driven losses on both co- and counter- sides of the velocity-space. Finally, a very trapped and high gyroradius losses, with an unclear origin, have been measured in the co- and counter-current velocity-space. The computed ion trajectories show that these ions remain permanently near the vessel wall, suggesting that they are accelerated within the scrape-off layer.

ELM↗