Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Diagnosing electric and magnetic fields in laser-driven coil targets

Laser-driven capacitor coils are widely used to generate intense magnetic fields for various applications in high-energy-density (HED) physics research. Accurate measurement of the magnetic fields is essential but challenging, due to the overlapping contributions from magnetic and electric fields in proton radiography, which is the primary tool diagnosing the field generation around the coils. In this study, we systematically analyze proton radiographs obtained from laser-driven capacitor-coil targets along two orthogonal axes under various electromagnetic field conditions, including magnetic field only, electric field only, and combined electromagnetic fields. By analyzing key features in the radiographs, we distinguish and characterize the respective contributions from magnetic and electric fields. Using detailed simulations validated by experimental benchmarks, methods to isolate and quantify the magnetic field and electric field are given. The methods are successfully applied to determine the electric current and charge distribution in a double coil configuration. Our findings provide insights into improving the diagnostic capability of proton radiography, potentially leading to more accurate measurements of electromagnetic fields and enhancing the utility of laser-driven capacitor coils in HED experiments.

electromagnetic field diagnostics↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Global stochastic optimization of stellarator coil configurations

In the construction of a stellarator, the manufacturing and assembling of the coil system is a dominant cost. These coils need to satisfy strict engineering tolerances, and if those are not met the project could be cancelled as in the case of the National Compact Stellarator Experiment (NCSX) project. Therefore, our goal is to find coil configurations that increase construction tolerances without compromising the performance of the magnetic field. In this paper, we develop a gradient-based stochastic optimization model which seeks robust stellarator coil configurations in high dimensions. In particular, we design a two-step method: first, we perform an approximate global search by a sample efficient trust-region Bayesian optimization; second, we refine the minima found in step one with a stochastic local optimizer. To this end, we introduce two stochastic local optimizers: BFGS applied to the sample average approximation; and Adam, equipped with a control variate for variance reduction. Numerical simulations performed on a W7-X-like coil configuration demonstrate that our global optimization approach finds a variety of promising local solutions at less than 0.1% of the cost of previous work, which considered solely local stochastic optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

Record magnetic field generation by short-pulse laser-driven capacitor-coil targets

Magnetic fields generated by capacitor-coil targets driven by intense short-pulse lasers have been characterized using ultrafast proton radiography. A 1-kJ, 15-ps laser at a center wavelength of 1053 nm irradiated the back plate of the capacitor with an intensity of ∼8.3 × 10 18 W/cm 2 , creating ultra large currents in the connecting coils. High-quality proton data obtained in the axial probing geometry show definitive signatures of magnetic field generation, allowing precision measurement of the field distribution and strength. The data show a coil current of 120 ± 10 kA producing 200 ± 20 Tesla magnetic fields at the coil center at 1.127 ns after the laser drive. In conclusion, this sets a record for magnetic field generation by the short-pulse-powered capacitor-coil targets.

Gao, Lan [Princeton Plasma Physics Laboratory (PPP↗

Measuring magnetic fields in laser-driven coils with dual-axis proton deflectometry

Abstract By driving hot electrons between two metal plates connected by a wire loop, high power lasers can generate multi-tesla, quasi-static magnetic fields in miniature coil targets. Many experiments involving laser-coil targets rely on proton deflectometry directed perpendicular to the coil axis to extract a measurement of the magnetic field. In this paper, we show that quantitative measurements using perpendicular probing are complicated by the presence of GV m −1 electric fields in the target that develop on sub-ns timescales. Probing parallel to the coil axis with fiducial grids is shown to reliably separate the electric and magnetic field measurements, giving current estimates of I ≈ 5 kA in 1 mm- and 2 mm-diameter wire loops. An analytic model of proton deflection in electric and magnetic fields is used to benchmark results from the particle-in-cell code and help deconvolve the magnetic and electric field deflections. Results are used to motivate a new experimental scheme that combines a single-plate target with axial proton probing and direct current measurements. This scheme has several important advantages over the traditional target and diagnostic set-up, enabling the robust measurement of coil magnetic fields and plasma properties, as well as making it easier to validate different theoretical models at a range of laser intensities.

Bradford, P. (ORCID:0000000296186342)↗

An experimental study to investigate magnetic field and winding force-dependent contact resistance of NI REBCO coil

Abstract This paper reports the magnetic field and winding force-dependent contact resistance, also known as characteristic resistance, of no-insulation (NI) REBCO coil. Three NI coils were wound with different winding forces ( < 1 kgf, 3 kgf, and 5 kgf) using the same REBCO-coated conductor, and they were tested at 4.2 K in a background field of 0, 5, 10, and 14 T. The contact resistance of each coil is measured at each field. As a result of the measurements, we draw two conclusions. First, a quadratic function for magnetic field intensity reasonably reproduces the measurement results of each NI test coil’s magnetic field-dependent contact resistance, where the practical fit function’s coefficients are determined depending on the winding force. Second, the contact resistance of each coil is partially inconsistent with the magnetoresistance of the electroplated material, i.e. copper, of the REBCO-coated conductor. This paper will present the measurement results in detail, discuss them with Kohler’s rule, and formulate the contact resistance using winding force and magnetic field terms.

Bang, Jeseok (ORCID:0000000247616334)↗

Spaced Orthocyclic Winding Pattern for Improved Die Compressed Coils

Winding fill, coil fill, or packing factor, is critical to the performance of many types of electromagnetic devices from electric machines to actuators, transformers, inductors, etc. One technique to increase the packing of conductors in the winding area is to compress round magnet wire conductors in a die, so that they deform and air voids between coil turns are removed. The winding layout of the coil turns on a bobbin before compression has a direct impact on the achievable coil fill and the damage to the coil insulation or conductors after compression. It is thought that winding the turns in an orthocyclic pattern on the bobbin before compression would minimize damage to the turns. This however causes turns to displace during the winding compression process. A new pre-compression winding pattern is proposed, a spaced orthocyclic winding, to minimize turn displacement and damage. A design of experiments study has been carried out to optimize this winding method and to compare it to the traditional orthocyclic winding.

33 ADVANCED PROPULSION SYSTEMS↗

Encapsulation Residual Stress and Ferrite Loss in Inductive Coil Assemblies

As inductive wireless charging reaches higher power levels, thermal management and mechanical durability become more critical. To address these concerns, past works have demonstrated the benefit of encapsulating coil assemblies in thermally conductive materials. However, due to the sensitivity of the MnZn ferrites commonly used in coil assemblies to mechanical stress, care must be taken to avoid creating large stresses in the ferrite that cause higher hysteresis loss. The stress formation in the encapsulant curing process is overviewed and modeled and an experiment is performed to demonstrate the effect in a small-scale coil assembly. Finally, the effect is shown in the reduced coil-coil efficiency of a first generation high power inductive power transfer prototype using a stiff epoxy compared to better performance in a second prototype using a softer thermally-conductive silicone encapsulant.

Foote, Andrew↗

Design of High-Power Polyphase PCB Coil Systems for Wireless Power Transfer

Printed circuit board (PCB) coils have been proposed prior for implementation as inductive wireless charging coils to minimize size and cost. Utilization of PCBs can allow for a reduced cost, improved manufacturability, and a wide range of geometric customization options. To circumvent material limitations on insulation and thermal performance, parallel paths can be implemented to divide the current per path accordingly. Within this paper, an unconventional high-power PCB coil is designed employing all possible techniques for wiring with axial and radial parallel paths with equivalent transposition to minimize circulating currents. Design studies are simulated in 3D finite element analysis (FEA) to evaluate imbalance between phases with and without transposition. Two experimental prototype coils were fabricated with measurements for self-inductance and mutual inductance between phases. These measurements were validated to be sufficiently consistent with FEA results. Additionally, a method is proposed for a two-step optimization of coupling coefficient and coil losses.

Lewis, Donovin D.↗

Design and Performance Assessment of Intermediary Coils for Misalignment Tolerance Improvement in Wireless Power Transfer Systems

This paper investigates the use of intermediate coils positioned between the primary and secondary coils in Wireless Power Transfer (WPT) systems for electric vehicle (EV) charging, with the objective of improving power transfer efficiency and robustness under misalignment conditions. An optimized 1 kW power system that operates at 85 kHz is developed and the misalignment performance was analyzed and compared with and without intermediate coils. A preliminary increase in efficiency of 2.3% at a misalignment of 52% of the coil radius is shown to be possible for a passive intermediate coil. An experimental prototype is built for design verification.

Sivka, Gozde [ORNL]↗

Elliptic Aperture CCT Coils for HTS Dipole Magnets

High-temperature REBa$_{2}$Cu$_{3}$O$_{7-x}$ (REBCO) superconductors are a route to increase the field of accelerator magnets beyond the 15-16T practical limit of Nb$_{3}$Sn. REBCO cabled in a CORC geometry is a promising fit for this application, enabling the design of low inductance magnets with conductor transposition. However, the use of CORC in coils with the tight conductor bending radii typical of accelerator magnets remains a key challenge, with on-going research both on the conductor development and coil design fronts seeking to address this issue. Here, in this work we explore the tradeoffs between circular and elliptic aperture canted-cosine-theta (CCT) coils when the conductor minimum bending radius is a key consideration, concluding that aperture ellipticity is an important free parameter in the optimization of magnetically efficient CORC dipole magnets. In particular, we show that elliptic bore designs enable a regime of smaller aperture HTS coils, an important result for LTS-HTS hybrid magnets and more generally for accelerator applications benefiting from non-circular magnet apertures. To this end we present an elliptic aperture dipole design optimized for hybrid testing within the US Magnet Development Program (US-MDP) and share 77 K test results of a prototype coil which provides first experimental confirmation of the advantages.

Brouwer, L. [Lawrence Berkeley National Laboratory↗

Eddy Current Model of a Coil Over An Infinite Perfectly Electrical Conductor (PEC) Half-Plane

Eddy current sensors measure the lift-off or distance between the sensor and a conducting surface. They operate on the principle of an alternating current in a conduction coil inducing a magnetic field within the surface. An eddy current is set up in the surface to counter the incident magnetic field which, in turn, sets up a magnetic field which counters that of the coil. This changes the coil impedance which is a function of the lift-off. As the lift-off increases, the effect of the eddy current magnetic field on the coil magnetic field weakens, resulting in a higher inductance and lower resistance. Thus, the lift-off may be derived from an impedance measurement. Dodd and Deeds developed an analytic model for an eddy current sensor coil impedance with an air core which has been implemented in MATLAB. LLNL assembled an eddy current sensor with a mu-metal core for which there is no analytic model. Rather than derive an analytic model which includes the mu-metal core, analytic empirically based functions are derived to map the Dodd and Deeds model to measured inductance and resistance.

42 ENGINEERING↗

Miniature Coil for Wireless Power and Data Transfer through Aluminum

This paper presents the design and development of miniature coils for wireless power and data transfer through metal. Our coil has a total size of 15 mm × 13 mm × 6 mm. Experimental results demonstrate that we can harvest 440 mW through a 1 mm-thick aluminum plate. Aluminum and stainless-steel barriers of different thicknesses were used to characterize coil performance. Using a pair of the designed coils, we have developed a through-metal communication system to successfully transfer data through a 1 mm-thick aluminum plate. A maximum data rate of 100 bps was achieved using only harvested power. To the best of our knowledge, this is the first report that demonstrates power and data transfer through aluminum using miniature coils.

42 ENGINEERING↗

A 12 coil superconducting bumpy torus magnet facility for plasma research

A summary is presented of the performance of the two-coil superconducting pilot rig which preceded the NASA Lewis bumpy torus. This pilot rig was operated for 550 experimental runs over a period of 7 years. The NASA Lewis bumpy torus facility consists of 12 superconducting coils, each with a 19 cm in diameter and capable of producing magnetic field strengths of 3.0 teslas on their axes. The magnets are equally spaced around a major circumference 1.52 m in diameter, and are mounted with the major axis of the torus vertical in a single vacuum tank 2.59 m in diameter. The design value of maximum magnetic field on the magnetic axis (3.0 teslas) was reached and exceeded. A maximum magnetic field of 3.23 teslas was held for a period of 60 minutes, and the coils did not go to normal. When the coils were charged to a maximum magnetic field of 3.35 teslas, the coil system was driven normal without damage to the facility.

Roth, J. R.↗

Processing and plating helical metallic coils

The results of research efforts to develop an optimized nickel cobalt coating suitable as a recording medium are outlined. The coating is to be used directly on a BeCu helical coil substrate of a helical coil NASA recorder. Specifically, efforts were made to: optimize the coating thickness; establish processes and techniques adaptable for the production of finalized plated helical coils; design and fabricate the equipment required for production and testing of the coils; and deliver finalized helical coils to NASA.

Source record↗

Technique for the efficient and reproducible fabrication of electromagnetic levitation coils

A technique has been developed for fabricating electromagnetic induction coils in a reproducible manner. The process utilizes a split mandrel that can be disassembled to remove the mandrel from the coil. The technique has increased coil production rates by a factor of 8 over the freehand winding method. The success rate for producing a functional levitation coil has been increased from 50 percent to 95 percent. The levitation coil designed during this work has successfully levitated and melted a variety of alloys including Cu, Ag, Ag-Ni, Cu-Fe, Fe-C, and Nb-Ge. W was also levitated but not melted at temperatures as high as 2700 C. The highest sample melt temperature achieved was 2400 C for the Nb-Ge samples.

Ethridge, E. C.↗

A comparison of ASTROMAG coils made with aluminum and copper based superconductor

The use of an aluminum matrix superconductor in the coils for the ASTROMAG magnet will increase the integrated field for conducting particle astrophysics experiments in space as compared to equal mass coils made with a copper matrix superconductor. The increased ability to detect charged particles can be achieved without decreasing the current margin of the superconductor in the coils. The use of a low-resistivity aluminum matrix conductor increases the energy needed to initiate a quench by two orders or magnitude. The current decay time constant during a quench is substantially increased. As a result, the quench energy dumped into the helium tank is reduced (the ASTROMAG coils are thermally decoupled from the helium tank), and the forces on the shield and shells due to eddy currents will be lower. A description is also given of the problems associated with the use of an aluminum matrix superconductor in the coils.

Green, M. A.↗