Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Optimization of the Geometric Beta for the SSR2 Cavities of the Project X

Project X based on the 3 GeV CW superconducting Linac and is currently in the R&D phase. The CW SC Linac starts from a low-energy SCRF section (2.1 - 165 MeV) containing three different types of resonators. HWR f = 162.5 MHz (2.1 - 11 MeV) having beta= 0.11, SSR1 f = 325 MHz (11 - 35 MeV) having beta = 0.21. In this paper we present the analysis that lead to the final design of SSR2 f = 325 MHz cavity (35 - 165 MeV). We present the results of optimization of the geometric beta and the comparison between single, double and triple spoke resonators used in Project X frontend. A {beta} optimization has been carried out for the last spoke cavity section of Project X front end. The optimization process of {beta}{sub opt} for a single spoke resonator family SSR2 shown that {beta}{sub opt} = 0.47 looks better than the previous choice, which is {beta}{sub opt} = 0.4. This change can save some cavities and provide the same final energy for this section, 160 MeV. Single double and triple spoke resonator performances have been compared. The best option is the single spoke resonator SSR2 because the NTTF of a multi-spoke resonator is much narrower than a single one. In the energy range considered (40-160 MeV) the most efficient resonator is the single spoke one.

43 PARTICLE ACCELERATORS↗

Single Spoke Cavities for Low-energy Part of CW Linac of Project X.

In the low-energy part of the Project X H-linac three families of 325 MHz SC single spoke cavities will be used, having {beta} = 0.11, 0.21 and 0.4. Single spoke cavity was selected for the linac because of higher r/Q. Results of optimization of all cavities are presented. Results of the beam dynamics optimization for initial stage of the linac with beta=0.11 single spoke cavity are presented at poster MOPEC082 (this conference).

43 PARTICLE ACCELERATORS↗

Preparatory procedure and equipment for the European x-ray free electron laser cavity implementation

The European x-ray free electron laser is under construction at Deutsches Elektronen-Synchrotron (DESY). The electron beam energy of up to 17.5 GeV will be achieved by using superconducting accelerator technology. Final prototyping, industrialization, and new infrastructure are the actual challenges with respect to the accelerating cavities. This paper describes the preparation strategy optimized for the cavity preparation procedure in industry. For the industrial fabrication and preparation, several new hardware components have been already developed at DESY. The design and construction of a semiautomated rf-measurement machine for dumbbells and end groups are described. In a collaboration among FNAL, KEK, and DESY, an automatic cavity tuning machine has been designed and four machines are under construction. The functionality of these machines with special attention to safety aspects is described in this paper. A new high pressure rinsing system has been developed and is operational.

43 PARTICLE ACCELERATORS↗

Design and fabrication of robust hybrid photonic crystal cavities

Abstract Heterogeneously integrated hybrid photonic crystal cavities enable strong light–matter interactions with solid state, optically addressable quantum memories. A key challenge to realizing high quality factor ( Q ) hybrid photonic crystals is the reduced index contrast on the substrate compared to suspended devices in air. This challenge is particularly acute for color centers in diamond because of diamond’s high refractive index, which leads to increased scattering loss into the substrate. Here, we develop a design methodology for hybrid photonic crystals utilizing a detailed understanding of substrate-mediated loss, which incorporates sensitivity to fabrication errors as a critical parameter. Using this methodology, we design robust, high-Q, GaAs-on-diamond photonic crystal cavities, and by optimizing our fabrication procedure, we experimentally realize cavities with Q approaching 30,000 at a resonance wavelength of 955 nm.

Abulnaga, Alex↗

Pathways for a compact double-quarter wave cavity with low peak surface fields and large deflecting kick

This paper describes the parameter choices necessary to obtain a compact Double Quarter Wave (DQW) cavity with low peak surface fields – electric and magnetic – and large deflecting kick. The work is motivated by the space limitations and demanding crabbing voltage required for the crabbing system of the Electron-Ion Collider (EIC) and focuses on the optimization of the 197 MHz crab cavities for the EIC’s hadron ring. For a crabbing voltage of 11.5 MV, the optimized cavity is less than one meter long, showing a maximum peak surface magnetic field of 70 mT and a maximum peak surface electric field of 45 MV/m.

43 PARTICLE ACCELERATORS↗

Quest for an Optimal Methane Hydrate Formation in the Pores of Hydrolytically Stable Metal–Organic Frameworks

Porous metal–organic frameworks (MOFs) capable of storing a relatively high amount of dry methane (CH 4 ) in the adsorbed phase are largely explored; however, solid CH 4 storage in confined pores of MOFs in the form of hydrates is yet to be discovered. Here we report a rational approach to form CH 4 hydrates by taking advantage of the optimal pore confinement in relatively narrow cavities of hydrolytically stable MOFs. Unprecedentedly, we were able to isolate methane hydrate (MH) nanocrystals with an sI structure encapsulated inside MOF pores with an optimal cavity dimension. Furthermore, it was found that confined nanocrystals require cavities slightly larger than the unit cell crystal size of MHs (1.2 nm), as exemplified in the experimental case study performed on Cr- soc -MOF-1 vs smaller cavities of Y- shp -MOF-5. Under these conditions, the excess amount of methane stored in the pores of Cr- soc -MOF-1 in the form of MH was found to be ≈50% larger than the corresponding dry adsorbed amount at 10 MPa. More importantly, the pressure gradient driving the CH 4 storage/delivery process could be drastically reduced compared to the conventional CH 4 -adsorbed phase storage on the dry Cr- soc -MOF-1 (≤3 MPa vs 10 MPa).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design Optimization of Superconducting Parallel-bar Cavities

The parallel-bar structure is a new superconducting geometry [1] whose features and properties may have significant advantages over conventional superconducting deflecting and crabbing cavities for a number of applications. Jefferson Lab is in need for a 499 MHz, 11 GeV rf separator as part of its 12 GeV upgrade program. We report on design optimization studies performed to-date for this and other applications.

43 PARTICLE ACCELERATORS↗

50% continuous-wave wallplug efficiency from 1.53μm-emitting broad-area diode lasers

Long-wavelength InP-based diode lasers emitting at 1.53 μm have been optimized for maximum continuous-wave (CW) electrical-to-optical power conversion efficiency, so-called wallplug efficiency (WPE). Efficient electron and hole capture into a single-quantum-well (SQW) active region as well as suppression of electron and hole leakage out of the SQW result in high values for the internal differential efficiency: ∼97% for long-cavity (≥2 mm) uncoated-facet devices and ∼85%–89% for short-cavity (1.5 mm) optimized facet-coated devices. The characteristic temperature of the slope efficiency, T{sub 1}, reaches a high value of 323 K. Doping-level optimization of the p-cladding layer and the use of the SQW result in low values for the internal loss coefficient: ∼1.1 cm{sup −1} for long-cavity (≥2 mm) uncoated-facet devices and ∼1.5–2.0 cm{sup −1} for short-cavity (1.5 mm) optimized facet-coated devices. In turn, a maximum CW WPE value of 50% is achieved at room temperature and ∼1 W output power from conductively-cooled 100 μm-wide-aperture devices. The maximum CW power is 2.5 W. One beneficial byproduct of the CW-WPE maximization process is a large transverse spot size which, in turn, provides a very narrow transverse beamwidth: 26° full width half maximum. Reliability tests show no degradation when devices are run CW at high currents (4–5 A) and high temperatures (40–50 °C) for over 4000 h, at ∼2 W output power.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimal feedback in efficient ring double-cavity optical parametric oscillators

It is shown that the use of two feedback circuits with matched transfer constants and optimal phase incursions in a nondegenerate optical parametric oscillator (OPO) makes it possible to localise the extremes of intensity distributions of interacting waves on the output face of a nonlinear crystal, which provides maximum possible conversion efficiency of pump energy. The optimisation procedure in this case is rather flexible because it is reduced to ambiguous matching of the period and shift of the extremes of exact analytic solutions of the corresponding problem in the form of cnoidal waves with respect to the nonlinear crystal position. Unlike the single-cavity OPO scheme, both these parameters can substantially exceed the nonlinear crystal length and even tend to infinity, which corresponds to solitary soliton-like solutions. (optical parametric oscillators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of phonon reservoir on photon blockade in a driven quantum dot-cavity system

We theoretically investigate the influence of the phonon bath on photon blockade in a simultaneously driven dot-cavity system. An optimal condition for avoiding two-photon excitation of a cavity field is put forward which can be achieved by modulating the phase difference and the strengths of the driving fields. The second-order correlation function and the mean photon number of the cavity field are discussed. In the absence of phonon effect, the strong photon blockade in a moderate quantum dot (QD)-cavity coupling regime occurs, which can be attributed to the destructive quantum interference arisen from different transition paths induced by simultaneously driving the dressed QD-cavity system. The participation of acoustic-phonon reservoir produces new transition channels for the QD-cavity system, which leads to the damage of destructive interference. As a result, the photon blockade effect is hindered when taking the electron-phonon interaction into account. It is also found that the temperature of the phonon reservoir is disadvantageous for the generation of photon blockade.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A holey cavity for single-transducer 3D ultrasound imaging with physical optimization

Within the compressive sensing (CS) framework, one effective way to increase the likelihood of successful signal reconstruction is to employ random processes in the construction of the sensing matrix. This work presents a 3D holey cavity, with diverse frequency modes, to spectrally code, that is, randomize, the ultrasound wave fields. The simulated results show that the use of such a cavity enables imaging simple or complex targets, such as spheres or the letter E, by only a single transceiver—something that is not possible without the use of a coding structure like the cavity. The effect of noise on imaging results and the size of the targets on the first-order Born approximation (BA) are also investigated. Moreover, this study attempts to optimize the cavity, based on a single numerical metric, such as the sum of singular values (SSV) or mutual coherence (MC). Yet, it will be shown that neither of these metrics can consistently compare the norm-one imaging performance between two cavities of different materials or hole sizes. This leaves finding a quantitative metric for these kinds of optimizations an open problem.

42 ENGINEERING↗

Qualification of niobium materials for superconducting radio frequency cavity applications: View of a condensed matter physicist

We address the issue of qualifications of the niobium materials to be used for superconducting radio frequency (SCRF) cavity fabrications, from the point of view of a condensed matter physicist/materials scientist. We focus on the particular materials properties of niobium required for the functioning a SCRF cavity, and how to optimize the same properties for the best SCRF cavity performance in a reproducible manner. In this way the niobium materials will not necessarily be characterized by their purity alone, but in terms of those materials properties, which will define the limit of the SCRF cavity performance and also other related material properties, which will help to sustain this best SCRF cavity performance. Furthermore we point out the need of standardization of the post fabrication processing of the niobium-SCRF cavities, which does not impair the optimized superconducting and thermal properties of the starting niobium-materials required for the reproducible performance of the SCRF cavities according to the design values.

43 PARTICLE ACCELERATORS↗

Optimal feedback in efficient single-cavity optical parametric oscillators

An approach based on the description of competition of quadratic processes of merging and decomposition of quanta resulting in the formation of cnoidal waves on an effective cascade cubic Kerr-type nonlinearity is used to optimise the scheme of a single-cavity optical parametric oscillator. It is shown that the use of a feedback circuit (cavity) decreases the period of cnoidal waves produced in a nonlinear crystal, while the optimisation procedure of the transfer constant of this circuit (reflectivity of the output mirror of the cavity) is reduced to matching this period with the nonlinear crystal length. (optical parametric oscillators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and demonstration of a distributed-coupling linear accelerator structure

We present a topology for linear accelerators (linacs) in which the power is distributed to the cavities through a waveguide with periodic apertures that guarantees the correct phases and amplitudes along the structure length. Unlike conventional traveling and standing-wave linacs, the presented topology allows the cavity shapes to be designed without the constraints applied to the coupling between cells to transfer power from one cell to the next. Therefore, the topology permits more degrees of freedom for the optimization of individual cavity shapes in comparison with conventional linacs. The cavity shapes can be optimized for power consumption and efficiency, and/or the manipulation of the surface fields for high gradient operation. This topology also provides a possibility for low-temperature manufacturing techniques that prevent the annealing of the material during typical brazing processes; hence, the material could retain its original properties such as hardness. We present a design and an experimental demonstration of this linac.

43 PARTICLE ACCELERATORS↗

Multiwall carbon nanotube microcavity arrays

Periodic highly dense multi-wall carbon nanotube (MWCNT) arrays can act as photonic materials exhibiting band gaps in the visible regime and beyond terahertz range. MWCNT arrays in square arrangement for nanoscale lattice constants can be configured as a microcavity with predictable resonance frequencies. Here, computational analyses of compact square microcavities (≈0.8 × 0.8 μm{sup 2}) in MWCNT arrays were demonstrated to obtain enhanced quality factors (≈170–180) and narrow-band resonance peaks. Cavity resonances were rationally designed and optimized (nanotube geometry and cavity size) with finite element method. Series (1 × 2 and 1 × 3) and parallel (2 × 1 and 3 × 1) combinations of microcavities were modeled and resonance modes were analyzed. Higher order MWCNT microcavities showed enhanced resonance modes, which were red shifted with increasing Q-factors. Parallel microcavity geometries were also optimized to obtain narrow-band tunable filtering in low-loss communication windows (810, 1336, and 1558 nm). Compact series and parallel MWCNT microcavity arrays may have applications in optical filters and miniaturized optical communication devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal Thermal Gradient for Flux Expulsion in 600°C Heat-treated CEBAF 12 GeV Upgrade Cavities

We will present results on measurement of flux expulsion in CEBAF 12 GeV upgrade cavities and original CEBAF cavities and the search for optimal thermal gradient for reducing the trapped flux in cavities installed in CEBAF linacs. Preliminary measurements of one C100 cavities has shown that a nearly perfect flux expulsion can be achieved at an optimal thermal gradient - a surprising result contrary to the expectation of zero flux expulsion for 600°C heat treated niobium cavities. These results could lead to a cost-effective path for improving the quality factor of cavities installed in CEBAF and ultimately saving accelerator operation cost.

Geng, R.↗