Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capital”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Leveraging State Clean Water Revolving Funds to Expand Clean Energy Financing

To meet clean energy goals, states will need significant capital. Federal funding from the Inflation Reduction Act and the Infrastructure Investment and Jobs Act will help, including by capitalizing clean energy state revolving loan funds (RLFs). States can leverage state clean water revolving funds to finance even more clean energy improvements. New York and Pennsylvania have used this innovative mechanism to extend the impact of their clean energy loan programs. For states looking to extend the reach of their clean energy financing programs, the brief: -Explains how each state leveraged their state revolving funds, -Identifies critical success factors for doing so, and -Offers key elements for replicating this model In New York, New York State Energy Research and Development Authority structured a sale of bonds secured by the repayments from a portfolio of residential energy efficiency loans from its Green Jobs – Green New York Program, with the additional support of a guarantee from the state’s clean water revolving fund. The Pennsylvania Treasury Department received a direct investment of funds from Pennsylvania’s clean water revolving fund to support the relaunch of the Keystone Home Energy Loan Program (HELP), which had previously been shuttered due to lack of support funding. From our review of these two case studies, when facilitating state clean water revolving fund transactions to support clean energy lending, the following critical success factors emerged: -Reference to preventing atmospheric deposition resulting from the combustion of fossil fuels in the state’s Clean Water Act Section 319 Nonpoint Source Pollution Management Plan, which sets out that state’s strategy for reducing pollution into state waterways. -Strong relationships and trust between the clean water revolving fund administrator and the state agency administering the clean energy loan program. -Limited funding exposure for the clean water revolving funds—which are generally large and well capitalized—to ensure that any losses experienced by clean water revolving funds would have a negligible impact on the fund’s ability to support core water and wastewater projects. -Willingness, on the part of the clean water revolving fund administrator, to innovate and engage in careful analysis to support transaction structuring, and support from state energy partner organizations. The brief provides case studies of these states’ experiences, critical success factors, and key elements for replicating the model.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A National Infrastructure for Artificial Intelligence on the Grid (NI4AI) (Final Scientific/Technical Report)

Electric utilities have traditionally taken a very pragmatic yet myopic approach with grid sensors and the resulting collected data. Sensors are purchased and deployed to solve a specific, known problem that has risen to sufficient awareness as to justify the effort of deploying sensors and the needed capital investment. This sensor data flows into proprietary software packages with limited functionality intended only to address the initial problem. This approach aligns with the financial incentives of the utility to deploy capital into fixed hardware assets for which the corporations earn a rate of return. This mentality stands in stark contrast to the big data revolution that started nearly 25 years ago with the rise of Google. In this worldview, data is a fundamental business asset; successful organizations collect, store, explore, merge, and exploit as much data as possible to not only solve problems well understood today but also to tackle new problems that will inevitably rise tomorrow. The ARPA-E Open Innovation 2018 project entitled A National Infrastructure for Artificial Intelligence on the Grid or NI4AI for short was designed to demonstrate this alternative paradigm for using data. To do this, the project was composed of three key thrust areas. The first major component deployed a variety of high-frequency grid sensors and captured terabytes of both wide-scale and localized grid measurements, generating high-value datasets for grid research and algorithm development. The second aspect made available PingThings’ PredictiveGridTM, a horizontally scalable, cloud-based data management and AI platform built for time series data to explore and exploit the collected data. Finally, the project fostered a diverse and open research community composed of experts from numerous fields through focused educational content, code sharing, and data science competitions. Shifting away from “single use” sensors and closed data silos within electric utilities is a major benefit to the public at large. This legacy approach to data is incredibly (1) capital intensive (new sensors must be deployed for each new problem and problems tend to arise continuously) and (2) painfully slow (new problems must be identified first and then new sensors must be deployed to collect data to begin to address the issue). The transition to a carbon neutral grid requires a massive transformation of the existing grid infrastructure and will continue to challenge the legacy grid in unforeseen ways. The only way to make the energy transition cost effective is for utilities to abandon this dated data paradigm and adopt more contemporary approaches. NI4AI has shown that it is technically possible and economically feasible to ingest, explore, and exploit grid data collected from even very high frequency sensing, such as continuous point on wave sensors collecting measurements 10,000 times a second. In fact, the PredictiveGrid platform used is commercially available and deployed at several utilities in the United States. Project accomplishments were numerous and included (1) making available a state of the art time series platform to the community, (2) collecting over 520 streams of time series data from grid sensors totaling over 1 trillion grid measurements, and (3) developing and nurturing a community within the industry focused on the use of data to create value for utilities and, ultimately, end consumers.

97 MATHEMATICS AND COMPUTING↗

Economic Evaluation of a Coupled Nuclear Power Plant and Hydrogen Production Facility: A Case Study

This study optimized the design sizes and operation of a power-to-hydrogen-to-power integrated energy system to allow a baseload power plant to operate flexibly in the energy market. In collaboration with a utility industry partner, the system, consisting of an electrolyzer, compressors, storage tank, and fuel cell, was optimized under conditions specific to the proposed project at the site of a nuclear power plant. The Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems (DISPATCHES) maximized net present value by optimizing sizing of components and dispatch decisions. Revenues included sale of electricity, capacity payments typical of the New York Independent System Operator, and the section 45V hydrogen production tax credit of the Inflation Reduction Act of 2022 (the tax credit was assumed to be available to legacy plants in the absence of clear guidance at present). Under default assumptions which excluded many capital expenditures, the base case optimized solution had a net present value of $\$$1.4 million over a 30 year lifetime, with a 0.365 MW fuel cell operating nearly continuously and 85% of revenues supplied by the hydrogen production tax credit (which was counted as a revenue regardless of profit, thus assuming credit monetization or offset of taxes within the larger firm was possible in all years). Beyond the base case, a sensitivity study elucidated drivers of the economics as capacity payment rate and hydrogen production tax credit rate vary. Additional sensitivity studies also extended results to variation of other, previously fixed parameters, including the fuel cell capital cost, and to imposition of further constraints. Optimization was also repeated for the default assumptions but recognizing tax credits upon use of hydrogen rather than upon its production, producing no change in the optimal solution. Most notably, capacity payments above $\$$15/kW-month drove optimal fuel cells multiple times larger than those with the default estimated capacity payment of $\$$2.5/kW-month (approaching 11 vs. 0.365 MW), and these larger fuel cells operated rarely (capacity factors of ~0.03). Furthermore, when the hydrogen production tax credit was provided for only 10 years, under the specific assumptions of this study (e.g., neither site preparation costs nor electrolyzer capital cost counted), the optimal solution avoided economic loss by ceasing system operation after the 10th year. Viewed broadly, this study demonstrated the capabilities of DISPATCHES, which can be user-adapted to serve other industrial case studies.

08 HYDROGEN↗

Logging Crew Attributes by Region in the Southeast USA

Urbanization, shrinking markets, and reduced forestry investment may affect harvesting efficiency in regions of the US South. To monitor these conditions, logging businesses have been tracked by surveys conducted by universities and trade associations. This project used a sampling approach coordinated with FIA utilization studies to sample logging crews based on a harvesting location. The approach was used to develop relationships among firm attributes and site attributes in six southeastern states (AL, GA, FL, NC, SC, and VA) from 2011 to 2018. The data included harvest attributes (location, harvest size and stand type) and logging firm attributes (production, crew labor, crew number, the number of machines by type, and machine age). For crew capital value, an equation was developed for this study using machine number and average machine age. The data from logging crews on 419 harvests were analyzed by region, harvest size, and stand type. Mean values for crew labor ranged from 3.1 to 7.1 workers. The average capital value per crew ranged from $\$220,000$ to $\$524,000$ per crew in the Coastal Plain with a narrower range in the Piedmont. In the Coastal Plain, higher productivity was detected for larger harvests and pine versus hardwood and mixed stands; however, in the Piedmont those trends were less obvious. Ratio of feller-bunchers, skidders and loaders were mostly 1:1:1 or 1:2:1 with 41% and 24% of samples, respectively. There were notable trends among Coastal Plain loggers regarding capital value and productivity with evidence supported by a production function. The differences in Piedmont (e.g., ownership size, market access, terrain, population density, etc.) may combine to limit daily production and labor productivity.

54 ENVIRONMENTAL SCIENCES↗

Numerical Model Development of a Variable-Geometry Attenuator Wave Energy Converter: Preprint

Because the wave energy industry is still in its infancy, an optimal design for wave energy converters (WECs) has yet to be established; more work is needed to explore various cost reduction pathways. The primary cost-reduction pathway considered for this work is the optimization of the geometric profile on an attenuator WEC to maximize power production while, at the same time, minimizing capital expenditures through the use of variable-geometry modules. In this investigation, the variable geometry modules consist of inflatable bags placed on either side of a base central steel cylinder that would be inflated in low moderate sea states to maximize power capture and then deflated in moderate-extreme sea states to minimize wave loading. The numerical model and simulation of the attenuator WEC were developed and completed using WEC-Sim, which is an open-source code that is appropriate for use in evaluating the dynamic response of the different WEC models in operational seas. The power production estimates were obtained from the Wave Energy Prize (WEP) sea states, which are representative of U. S. deployment sites, to calculate the average climate capture width that is used in the WEP ACE calculation. Preliminary capital expenditure costs were obtained assuming the base central steel cylinder mass was equal to the fluid displaced mass, minus the mass of the variable-geometry bags. The additional weight required to offset the additional buoyancy from the variable-geometry bags was assumed to come from the addition of seawater ballast. The variable-geometry attenuator model was found to have a similar power capture efficiency as a fixed-body model, but is expected to have a lower characteristic capital expenditure given its more streamlined profile, which demonstrates that variable-geometry modules may provide a realistic cost-reduction pathway to help design a more cost-competitive WEC.

50 EE - Wind and Water Power Program - Water (EE-4↗

Development and Application of a Risk Analysis Toolkit for Plant Resources Optimization

This report summarizes the R&D activities of the Risk Informed Asset Management (RIAM) project during fiscal year 2020 (FY20). This project focuses on the development of methods designed to optimize plant operations (e.g., maintenance/replacement schedule, optimal maintenance posture) provided system/component health/cost data. This project development lives in cooperation with the Plant Health Management (PHM) project which focuses on the development of methods that integrate component health data and propagate such information at the system level to evaluate most relevant sources of risk. This year’s activities for the RIAM project focused on the continuation of schedule optimization algorithms developed in FY19. While in FY19 we focused on both deterministic and stochastic capital budgeting methods, in FY20 we moved forward by implementing two versions of schedule optimization methods. The first one reformulates the capital budgeting problem in a distributionally robust form which allows the user to rely on data directly rather than proposing a distribution from the data itself. The second version reformulates the capital budgeting explicitly using risk measures as variables to maximize/minimize. Lastly, we focused on the development of methods designed to identify the optimal maintenance posture based on the Pareto Frontier analysis. Rather than performing a tradeoff analysis (i.e., identify the absolute best posture), the Pareto Frontier analysis performs a trade space exploration approach (i.e., identify value and costs of several postures and have the analyst perform the task of imposing desired value and cost constraints). This is performed by identifying maintenance postures that maximize value (e.g., system availability) and minimize operational costs, i.e., the Pareto frontier in a value-cost trade space.

97 MATHEMATICS AND COMPUTING↗

Effect of Power Plant Capacity on the CAPEX, OPEX, and LCOC of the CO2 Capture Process in Pre-Combustion Applications - Abstract

Aspen Plus v8.8 was used to simulate the pre-combustion CO2 capture process from a typical fuel gas stream at different power plant capacities ranging from 54.3 to 543 MW. Polyethylene glycol polydimethyl siloxane (PEGPDMS-1) was used as a physical solvent to capture CO2 in a countercurrent packed-bed absorber containing a structured packing (Mellapak 250Y). The process pressure was 51.4 bar and the solvent temperature was varied from 10 to 40 <sup>o</sup>C. The internal diameter of the absorber ranged from 1.9 to 7 m and the packing height from 13.9 to 45.5 m. The physico-chemical properties were obtained and modeled using the Perturbed Chain-Statistical Associating Fluid Theory (PC-SAFT) Equation-of-State (EOS).<p> Four process constraints were imposed in Aspen Plus: (1) no flooding in the absorber, (2) the absorber height to diameter ratio (H/D) is greater than or equal 6, (3) at least 90 mol% of the CO2 capture from the fuel gas stream, and (4) the CO2 stream destined to sequestration sites should contain less than 600 ppm water concentration and less than or equal 0.5 mol% of fuel gases (H2, CO, CH4). The plant lifetime was assumed to be 30 years with an annual discount rate of 10% and an annual maintenance cost of 4% of the total capital expenses.</p><p> Seven power plants with different capacities were used and for each plant, the corresponding CO2 capture process was simulated. The absorber flooding was checked using the generalized pressure drop correlation (GPDC) by Leva [1] and the capital expenditure (CAPEX), operating expenditure (OPEX), and levelized costs per ton of CO2 captured (LCOC) were calculated [2-5]. Normalized by the largest power plant capacity (543 MW) used in the simulation, the results indicated that the capital and operating expenditures increased, however, the LCOC decreased with increasing plant capacity. This behavior was due to the increased annual tonnage of the CO2 captured with plant capacity as shown in Figure 1. The calculated CAPEX, OPEX, LCOC and the tonnage of CO2 captured for the 543 MW power plant were about 52 MM$, 22 MM$/year, 7.46 $/ton and 4 MM ton/year.</p>

Ashkanani, Husain↗

Wash Vehicle Fleet Sizing for Contingency Planning Against Dust Storms: Preprint

Wash vehicles containing either high- or low-pressure water sprayers, a collection of rotating brushes, or a combination of these, are frequently utilized in concentrating solar power (CSP) plants to maintain a high level of optical efficiency in the solar field. In recent years, multiple modeling approaches have been developed to obtain fleet sizes and mirror-washing schedules that optimize the tradeoff of vehicle capital and use costs and labor versus lost revenues due to soiling. These planning models cover normal operating conditions well but do not consider rare events such as dust storms which can a significant reduction in receiver productivity, or shut down operations until most or all of the solar field’s mirrors have been cleaned. To that end, we propose a methodology that evaluates whether additional capital should be deployed to hedge against these events by weighing the net present value of the expected benefits against the capital costs. The output of this method is a breakeven frequency, a metric we sue to determine whether an additional vehicle should be purchased to address the contingency of dust storms by comparing it to the expected annual storm frequency We develop a small collection of case studies using commercial-scale CSP tower plants and obtain breakeven frequencies that mostly fall between 0.1 and 1.0 storms per year, depending on the existing fleet size and storm severity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Advancing Clean Energy Equity

This year’s Financial Innovations Roundtable (June 16-17, 2022) focused on advancing clean energy equity and was co-hosted by the University of New Hampshire's Carsey School of Public Policy and the Federal Reserve Bank of New York. Clean energy technologies are better than ever, with costs continuing to decline. Yet the low-income and under-resourced communities – particularly communities of color, Native communities, and other traditionally marginalized populations – that are disproportionately impacted by climate and severe weather-related events lag in clean energy investments. Community Development Financial Institutions (CDFIs) have a long track record of providing access to capital to low- and moderate-income communities nationwide. Green Banks, established at state and local levels, use innovative financing to attract private capital and incentivize investments in clean and renewable energy. Together, the nation's network of more than 1,300 CDFIs and 21 Green Banks have the financing expertise and deep market understanding and relationships to finance a transition to clean energy. This event explored how Green Banks and CDFIs can funnel creditworthy projects to market and efficiently raise capital for them. Building on the Carsey School White Paper, Clean Energy Project Development for Low-Income Communities: Strengthening the Ecosystem for Delivering Solar Energy and Deep Efficiency Retrofits (Hangen, 2022), the FIR sought to identify options and create opportunities for Green Banks, CDFIs, and impact investors to collaborate in offering a range of products, approaches, and tools to better serve communities and individuals who have thus far been left out of the transition to clean energy. The event had 101 participants from a variety of sectors including CDFIs, Green Banks, mission-driven clean energy organizations, government agencies, banks, and impact investment professionals.

14 SOLAR ENERGY↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Internal Financing for Carbon Reduction Projects

This fact sheet summarizes 6 common internal financing modes and provides examples for each: Capital Expenditure/Operating Outlay, Self-Funded Energy Performance Contracts (ESPC), Carbon Fee Funds, Green Bonds, Green Revolving Funds, and Capital Investment Funds.

financing, carbon reduction, carbon emissions, ESP↗

Decarbonization of the Electric Power Sector and Implications for Low-Cost Hydrogen Production from Water Electrolysis

Increasing development of wind and solar generation in the power sector can create economic opportunities for the deployment of water electrolyzers that produce hydrogen. Temporal variation in the marginal cost of energy in future decarbonized grids can make it favorable for electrolyzers to dispatchably ramp hydrogen production up and down in response to low- and high-cost times. Using this strategy, low-cost hydrogen production is enabled by electrolyzers that are low-capital cost and tolerant to frequent on/off cycling. Ramping down hydrogen production to a designated turndown ratio can avoid performance degradation caused by on/off cycling by not shutting the electrolyzer completely off. This comes with a slight cost penalty which can be minimized if the turndown ratio is low (i.e., the system ramps down hydrogen production to close to zero). These results suggest that electrolyzers integrated into future power systems are likely to benefit from the ability to ramp operation up and down quickly and operate in a standby mode. This analysis forms a basis for comparative tradeoffs between electrolyzer capital cost, operating strategy, and system durability and demonstrates the importance of considering all three factors in technoeconomic analysis.

capital cost↗

Techno-economic analysis of advanced small modular nuclear reactors

Here, small modular nuclear reactors (SMRs) represent a robust opportunity to develop low-carbon and reliable power with the potential to meet cost parity with conventional power systems. This study presents a detailed, bottom-up economic evaluation of a 12 × 77 MW e (924 MW e total) light-water SMR (LW-SMR) plant, a 4 × 262 MW e (1,048 MW e ) gas-cooled SMR (GC-SMR) plant, and a 5 × 200 MW e (1,000 MW e total) molten salt SMR (MS-SMR) plant. Cost estimates are derived from equipment costs, labor hours, material inputs, and process-engineering models. The advanced SMRs are compared to natural gas combined cycle plants with and without post-combustion carbon capture and a conventional large nuclear reactor. Overnight capital cost (OCC) and levelized cost of energy (LCOE) estimates are developed. The OCC of the LW-SMR, GC-SMR, and MS-SMR are found to be $\$4,844$/kW, $\$4,355$/kW, and $\$3,985$/kW respectively. The LCOE of the LW-SMR, GC-SMR, and MS-SMR are found to be $\$89.6$/MWh, $\$81.5$/MWh, and $\$80.6$/MWh respectively. A Monte Carlo analysis is performed, for which the OCC and construction time of the LW-SMR is found to have a lower mean and standard deviation than a conventional large reactor. The LW-SMR OCC is found to have a mean of $\$5,233$/kW with a standard deviation of $\$658$/kW and a 90 % probability of remaining between $\$4,254$/kW and $\$6,399$/kW, while the construction duration is found to have a mean of 4.5 years with a standard deviation of 0.8 years and a 90 % probability of remaining between 3.4 and 6.0 years. The economic impact of economies of scale, simplification, modularization, and construction time for SMRs are discussed. Additionally, policy implications for direct SMR capital subsidies and the impact of a carbon tax on natural gas emissions are explored.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Techno-economic analysis of non-aqueous hybrid redox flow batteries

Renewable energy has become indispensable to improving human life, but its growth is hampered by a lack of cost-effective energy storage systems to solve the intermittency problem. Non-aqueous hybrid redox flow batteries (NAqHRFBs), based on lithium metal anode and organic redox molecules (redoxmers), have been investigated as an attractive energy storage option because of their high cell voltages and energy densities compared to other redox flow battery candidates. However, little is known about the economic potential of NAqHRFBs, as well as the operational and materials impacts. This research establishes a techno-economic model to analyze the capital costs of NAqHRFBs with selected organic redoxmers, including 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO). Sensitivity analyses for current density, area-specific resistance, cell voltage, electrolyte composition, redoxmer price, and equivalent molecular weight indicate the key factors in controlling NAqHRFB capital cost. To make the current NAqHRFB cost-effective, the first priority is to increase the operation current density over 10 times of those used in lab-scale tests, followed by adjusting redoxmer-related characteristics to afford more cost reduction space such as decreasing the unit price by ~20 fold. The results have shed light on potential material development and system engineering directions to make NAqHRFBs viable for renewable energy storage.

25 ENERGY STORAGE↗

Compact Absorber Technology Leads to Significant Reduction in the Cost of Point Source CO 2 Capture

The size of columns in traditional absorption-based processes for CO 2 capture contributes significantly to the overall capital cost. A demonstrated method to reduce the cost of point source CO 2 capture, focusing on reducing the absorber height by increasing the liquid-to-gas reaction contact area and decreasing the CO 2 diffusion resistance without increasing gas-side pressure drop is presented along with techno-economic analysis results. Bench-scale tests on the unique Compact Absorber showed overall CO 2 mass transfer enhancement of varying degrees compared to a traditional packed column for similar process conditions, demonstrating that a 60+% reduction in size of a typical post-combustion absorber with a packing height of 70-100 ft and total height of 150-180 ft can be achieved. The techno-economic analysis showed significant cost reductions when the Compact Absorber is combined with other transformative aspects of the University of Kentucky Institute for Decarbonization and Energy Advancement point source CO 2 capture process compared to the U.S. Department of Energy National Energy Technology Laboratory pertinent reference case for pulverized coal plants with CO 2 capture. Here, a levelized cost of electricity excluding CO 2 transportation and storage of $\$95.6$/MWh was estimated, which is a 9% reduction, with a total capital cost contribution of $45/MWh, which is a 12% reduction. Additionally, a breakeven CO 2 sales price also referred to as the cost of CO 2 capture, of $36.70/tonne was estimated when the UK hindered primary amine solvent is used, which is a 20% reduction compared to the reference case.

CO2 capture↗

Prime Impact Fund (Final Technical Report)

PRIME Coalition Inc. constructed a first-of-its-kind impact investment fund comprised exclusively of charitable capital from grant and program-related investment-makers (private foundations, community foundations, corporate foundations, donor-advised funds, an d other corporate, family office, and individual donors). Prime Impact Fund was purpose-built to address the "innovation valley of death" in the energy sector, stepping into the capital gap with a new investment model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

US Potable Water Reuse System Costs

This submission contains a set of U.S.-specific potable reuse capital and operations and maintenance (O&M) cost data ($2020) found in published presentations and reports from engineering consulting firms, utility and water agency press releases or websites, and literature. For any unbuilt facilities, the reported costs found in technical documents are mostly engineer estimates and may be subject to change as construction proceeds. This data set contains a mix of both facility specific and total capital costs, which include conveyance infrastructure. Note that this dataset does not include detailed cost breakdowns for each of the facilities. This submission also contains the sources used to build this dataset in pdf format.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Cost-Performance Analysis of a Sodium Heat Engine for Distributed Concentrating Solar Power

We present that a sodium thermal electrochemical converter (Na-TEC) generates electricity directly from heat through isothermal expansion of sodium ions across a beta"-alumina solid-electrolyte. This heat engine has been considered for use with conventional concentrating solar power (CSP) systems before. However, unlike previous single-stage devices, the improved design uses two stages with an interstage reheat, allowing more economical and efficient conversion up to 29% at a hot side temperature of 850 °C. Herein, a cost-performance analysis for this improved design assesses opportunities for distributed-CSP in the context of micro-combined heat and power systems. A high-level techno-economic analysis (TEA) is presented that explores four scenarios where a Na-TEC is used as the heat engine for a distributed-CSP system. Overnight capital cost and levelized cost of electricity (LCOE) are estimated for a system lifetime of 30 years, revealing that overnight capital costs in a range from $3.57 to $17.71 per W e are feasible, which equate to LCOEs from 6.9 to 17.2 cents kWh e -1 . This analysis makes a significant contribution by concurrently quantifying the efficiency and unit costs for a range of multistage configurations, and demonstrating that a Na-TEC may be a promising alternative to Stirling engines for distributed-CSP systems at residential scale of 1–5 kW e .

14 SOLAR ENERGY↗