Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capillary pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Glass 3D Printing of Microfluidic Pressure Sensor Interrogated by Fiber-Optic Refractometry

This letter reports a novel fused silica microfluidic device with pressure sensing capability that is fabricated by integrated additive and subtractive manufacturing (IASM) method. The sensor consists of a capillary and a 3D printed glass reservoir, where the reservoir volume change under pressure manifests liquid level deviation inside the capillary, thus realizing the conversion between small pressure change into large liquid level variation. Thanks to the design flexibility of this unique IASM method, the proposed microfluidic device is fabricated with liquid-in-glass thermometer configuration, where the reservoir is sealed following a novel 3D printing assisted glass bonding process. And liquid level is interrogated by a fiber-optic sensor based on multimode interference (MMI) effect. This proposed microfluidic device is attractive for chemical and biomedical sensing because it is flexible in design, and maintains good chemical and mechanical stability, and adjustable sensitivity and range.

42 ENGINEERING↗

Water as a gas separation membrane

Efficient gas separation membranes are essential for carbon capture, biogas upgrading, and hydrogen purification. Inspired by how plants absorb CO 2 through water, we present a membrane platform that uses liquid water as the selective layer. Hydrophilic sub-100-nm pores stabilize water through strong capillary forces, enabling operation at feed pressures above 72 bar under dry and humid conditions. Selectivity is governed by gas solubility in water, while permeance is tuned by adjusting the water layer thickness. Reducing this thickness below 200 nm yields CO 2 permeances up to 11,600 gas permeation units with CO 2 :N 2 , CO 2 :CH 4 , and CO 2 :H 2 selectivities of 40, 26, and 31, respectively, surpassing the performance of state-of-the-art membranes. Operation is sustained for over a week without water loss, and performance scales using commercially available porous polymer supports under mixed-gas crossflow conditions. Water’s dissolution-based transport avoids saturation and reaction-rate limits, enabling a robust, high-performance, and environmentally benign gas separation platform.

08 HYDROGEN↗

DOE Award No.: DE-FE0023919 Phase 3 Scientific/Technical Report

This is the Phase 3 Report for the ‘Deepwater Methane Hydrate Characterization and Scientific Assessment or Genesis of Methane Hydrates in the Gulf of Mexico (GOM2)’ research project (DOE Award No. DE-FE0023919). The report summarizes activities from January 16, 2018 to September 30, 2019. The project is led by the University of Texas at Austin (UT). The objective is to gain insight into the nature, formation, occurrence and physical properties of methane hydrate-bearing sediments for the purpose of methane hydrate resource appraisal through the planning and execution of drilling, coring, logging, testing and analytical activities that assess the geologic occurrence, regional context, and characteristics of marine methane hydrate deposits in the Gulf of Mexico outer continental shelf (OCS). We determined that it would not be possible to pursue the project with the International Ocean Discovery Program (IODP) and then developed a revised science and operations plan to maximize the science using a commercial vessel within the budget that is available. We improved the scientific capability of the UT pressure core center by adding the ability to X-ray pressure cores, and the ability to cut and store multiple core samples for experimental analysis. We transferred pressure cores to peer institutions, including the National Energy Technology Lab (NETL) the United States Geological Survey (USGS Woods Hole). We made advances in understanding the composition and source of gasses locked in the methane hydrate from Green Canyon 955 (GC-955). We developed approaches to determine the in-situ salinity of hydrate-bearing samples, revealing that the in situ salinity of the GC 955 reservoir is just above that of seawater. We determined that the GC-955 hydrate reservoir is composed of sandy silt with a high concentration of hydrate interbedded with clayey silt with no hydrate present. We determined that some or all of the intervals bounding the hydrate reservoir are composed of material similar to the reservoir (sandy silt with hydrate and clayey silt with no hydrate), but with a lower net to gross. We determined that the reservoir effective permeability at a hydrate saturation of ~80-90 % is ~0.1 mD (or 1.0×10-16 m2) to ~0.5 mD (or 5.0×10-16 m2) and the intrinsic permeability is ~12 mD (or 1.2×10-14 m2). The GC-955 reservoir in-situ porosity of sandy silt is 0.38 to 0.40 and is largely independent of effective stress, and that the porosity of clayey silt is 0.33 at an in situ effective stress of 3.8 MPa to ~0.37 at zero effective stress. We developed a systematic, repeatable approach to studying hydrate reservoir properties by reconstituting individual lithofacies from dissociated pressure cores. We determined index properties of GC-955 reservoir, including liquid limit and plasticity, porosity, capillary behavior, and particle size distribution. We developed a more robust pressure coring technology. We finalized and published the UT-GOM2-1 Expedition Volume and we finalized a dedicated volume on the UT-GOM2-1 expedition that will be published in the American Association of Petroleum Geologists Bulletin (AAPG) in spring 2020.

03 NATURAL GAS↗

Design optimization of gap distance for the capillary limitation of a heat pipe with annular-type wick structure

In this study, an experimental investigation was conducted on the rising height and contact angle of fluid in an annular wick-type heat pipe. The annular wick-type heat pipe was characterized by a small gap between the wick structure and tube wall, which compensated for the pressure drop along the porous media and created additional capillary force. To describe and model the advantage of this gap, the rising of a wetting liquid in the gap between a vertical solid plate and a mesh (with a small angle between them) was experimentally measured and analyzed. An additional experiment was performed to investigate the effect of curvature on the capillary rise using tubes and meshes of varying radii. Resultantly, we confirmed that the linear combination of the contact angles of the solid plate and mesh could be applied to calculate the rising height from the Laplace–Young equation. Furthermore, the effect of curvature on the rising height of the liquid was negligible. These results were extended to the investigation of finding the optimal gap distance for the annular wick-type heat pipe by referring to previous studies. We observed that a gap distance of 1.27 mm provided the largest permeability (K) over the effective pore radius (r eff ) value for a heat pipe with ethanol, which in turn resulted in the highest capillary limitation. For a sodium heat pipe, a gap distance of 0.84 mm resulted in the highest capillary limitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating the Feasibility of Measuring and Analyzing Strain Caused by Changes in Barometric Pressure in the Vadose Zone

Changes in barometric pressure propagate into the subsurface where they can affect water level measurements in wells and cause vertical strain. Previous strain sensors were developed to measure vertical strain, but they were limited to measurements at a single depth, making it difficult to evaluate strains from a migrating pressure wave. Technology known as Coherence-length-gated Microwave Photonics Interferometry (CMPI) uses optical fiber sensors to measure strain at multiple locations. It has the potential to detect strain caused by variations in barometric pressure at multiple depths in the subsurface. The goal of this study is to evaluate the feasibility of using this technology to record the changes in vertical strain in the vadose zone from small fluctuations in air pressure. Propagation of these air pressure fluctuations is affected by hydrogeological properties such as water content and permeability. A second goal of this study is to evaluate how these properties affect the air pressure distribution, strain, and gas-phase diffusivity with a long-term goal of using strain to monitor the vadose zone. The focus of this study is on a suite of laboratory experiments that used a sand-filled column with an open head space. The CMPI fiber was packaged and embedded along the axis of the column to measure the strain at multiple locations while air pressure transducers were installed through the wall of the column. Small periodic fluctuations in air pressure, similar to barometric pressure fluctuations, were created in the head space of the column using an audio driven speaker driven at 4 Hz using a sinusoidal signal created by a function generator. Then, the fluctuations propagated along the column where they were measured by the transducers and recorded as functions of time. Initial tests were conducted using dry sand, but then additional tests were conducted after injecting water into the column, which changed the hydrologic and mechanical properties. Another experiment was conducted after creating a thin barrier to air flow, which was designed to simulate a thin layer of saturated ground during rainfall. A final experiment was conducted by changing the grain size of the material to create a heterogeneity in the upper half of the column. The suite of six experiments was conducted to highlight effects of variations in water content and heterogeneities on air pressure and vertical strain. Numerical simulations were also created to evaluate the laboratory data and to provide a baseline analysis for the results. The numerical simulations used the governing equations to linear poroelasticity and two-phase flow with boundary conditions representing the experiments. The conceptual model for strain caused by barometric pressure recognizes that a fluctuating barometric pressure causes fluctuations in the air pore pressure that decrease in amplitude and lag in time with increase depth. The pressure distribution results in two different loads that cause strain: 1.) a mechanical load as the barometric pressure acts on the ground surface; and 2.) pressure loading in the pore space. The results show that the total vertical strain is a contribution of both of these loads, and this is the strain that was observed in the laboratory. The lab experiments show that both air pressure and strain vary as sinusoids that propagate with depth. The amplitude of the air pressure and strain decrease as a function of depth in all the conditions that were evaluate. For example, in the dry sand, the amplitude of the air pressure decreases from 25 Pa at the head space to 5 Pa at a depth of 70 cm, whereas the amplitude of the strain decreases from 0.15 to 0.06 µε over the same depth interval. In many cases the amplitudes decrease is approximately negative exponential functions of depth. When water was injected into the sand and the saturation increased, the amplitude of the air pressure increased in the partially saturated sand but decreased sharply to zero where the soil was saturated. The strain decreased with depth, but the transition from partially to fully saturated conditions had little effect on the strain profile, even though it had a major effect on the air pressure. This apparently is because strain is caused by variations in both water and air pressure. The fluctuating air pressure caused the water pressure to fluctuate, which caused strain throughout the column. Phase delay of the air pressure and the strain both increase as linear to bi-linear functions of depth. The phase delays indicate that pressure propagates at a velocity of 7 to 8 m/s in dry or partially saturated sand, but it drops by more than an order of magnitude in the vicinity of the capillary fringe. The phase delays indicate the strain propagates faster than the pressure. The data indicate that the strain propagates from 1.2 to more than 4x faster than the pressure. Switching from sand to silt in the column caused the velocity of the pressure to drop by roughly half for both pressures, but curiously, it had little effect on the velocity of the strain.

54 ENVIRONMENTAL SCIENCES↗

Selective transport of light vs. heavy rare earth elements by sulfate/bisulfate complexes in hydrothermal fluids

Here, this study explores the transport of rare earth elements (REE) in acidic sulfate-bearing hydrothermal fluids and the implications for the fractionation of light/heavy REE in critical mineral deposits. The speciation of Nd (light REE) and Yb (heavy REE) sulfate complexes were determined via in situ Raman spectroscopy using fused SiO 2 capillary cells up to 300 ºC at saturated water vapor pressure and in a hydrothermal diamond anvil cell up to 500 ºC and 540 MPa. The REE monosulfate (REESO 4 + ) and REE disulfate (REE(SO 4 ) 2 - ) species are stable below 150 to 250 ºC but become less stable at higher temperatures, particularly the light REE, due to the decreased solubility of REE sulfate solids. At higher pressure, these REE sulfate complexes display an increased stability field up to 400 ℃. The REE bisulfate complex (REEHSO 4 2+ ) was identified with a wide stability field below 400 ºC for the HREE in acidic Yb 2 (SO 4 ) 3 -bearing solutions, whereas in Nd 2 (SO 4 ) 3 -bearing solutions, the LREE bisulfate complex is restricted to below 100 ℃. These results suggest that bisulfate is a previously unrecognized selective ligand for heavy REE transport at low temperature in acidic oxidized hydrothermal fluids. Such fluids are responsible for hydrothermal alteration in many REE deposits. Prediction of phase stabilities across pressure, temperature, and composition space (P-T- x ) is crucial for predicting the role of aqueous REE sulfate complexes in the mobilization of REE in crustal fluids.

58 GEOSCIENCES↗

A new capability for investigating the structure and dynamics of liquids at high pressures

Water and aqueous solutions are critical to many areas of science and technology. As a result, tremendous effort has been devoted to understanding them in detail. Despite over a century of research, fundamental questions about water and aqueous solutions remain unanswered. However, an intriguing possibility – that liquid water can exist in two thermodynamically distinct states – has emerged as the most likely explanation. The problem is that experimental confirmation of this hypothesis requires experiments on water at high pressures and low temperatures, conditions in which liquid water only exists briefly before turning into crystalline ice. This project investigated the feasibility of developing a new capability for study water and aqueous solutions under these challenging conditions. The physical constraints, such as the timescales for crystallization and thermal diffusion in supercooled water, were evaluated along with their impact on the design criteria for the instrument. Several basic design options were considered that could meet the technical requirements. The options were also evaluated with respect to their use of commercially available equipment versus the need for custom designs or in-house development. The project identified two viable options to pursue. The first option would use a high-pressure syringe pump in conjunction with fused silica (or sapphire) capillaries. The second option would use a diamond anvil cell. These options can both be used with optical spectroscopies, such as Raman or Infrared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-nanometer confinement enables facile condensation of gas electrolyte for low-temperature batteries

Abstract Confining molecules in the nanoscale environment can lead to dramatic changes of their physical and chemical properties, which opens possibilities for new applications. There is a growing interest in liquefied gas electrolytes for electrochemical devices operating at low temperatures due to their low melting point. However, their high vapor pressure still poses potential safety concerns for practical usages. Herein, we report facile capillary condensation of gas electrolyte by strong confinement in sub-nanometer pores of metal-organic framework (MOF). By designing MOF-polymer membranes (MPMs) that present dense and continuous micropore (~0.8 nm) networks, we show significant uptake of hydrofluorocarbon molecules in MOF pores at pressure lower than the bulk counterpart. This unique property enables lithium/fluorinated graphite batteries with MPM-based electrolytes to deliver a significantly higher capacity than those with commercial separator membranes (~500 mAh g −1 vs. <0.03 mAh g −1 ) at −40 °C under reduced pressure of the electrolyte.

25 ENERGY STORAGE↗

From Langmuir isotherm to Brunauer–Emmett–Teller isotherm

Abstract Developed for multilayer adsorption, the Brunauer–Emmett–Teller ( BET) isotherm considers the adsorption of the first layer as an equilibrium chemical reaction between adsorbate molecules and adsorption sites and the adsorption of the second and subsequent layers as a condensation–evaporation process. Following the recent development of an activity‐based formulation for the Langmuir isotherm for monolayer adsorption, we present an activity‐based formulation for the BET isotherm in which species concentrations are replaced with species activities. Capturing the adsorbent surface heterogeneity for the adsorption of the first layer, the resulting thermodynamic BET isotherm is shown to accurately represent pure component adsorption isotherms over the relative pressure range of zero to unity or prior to the onset of capillary condensation. The thermodynamic BET isotherm should facilitate accurate estimation of monolayer adsorption capacity and the corresponding adsorbent surface area.

Vyawahare, Pradeep↗

The mechanics of nucleation and growth and the surface tensions of active matter

Homogeneous nucleation, a textbook transition path for phase transitions, is typically understood on thermodynamic grounds through the prism of classical nucleation theory. However, recent studies have suggested the applicability of classical nucleation theory to systems far from equilibrium. Here, in this article, we formulate a purely mechanical perspective of homogeneous nucleation and growth, elucidating the criteria for the properties of a critical nucleus without appealing to equilibrium notions. Applying this theory to active fluids undergoing motility-induced phase separation, we find that nucleation proceeds in a qualitatively similar fashion to equilibrium systems, with concepts such as the Gibbs–Thomson effect and nucleation barriers remaining valid. We further demonstrate that the recovery of such concepts allows us to extend classical theories of nucleation rates and coarsening dynamics to active systems upon using the mechanically derived definitions of the nucleation barrier and surface tensions. Three distinct surface tensions—the mechanical, capillary, and Ostwald tensions—play a central role in our theory. While these three surface tensions are identical in equilibrium, our work highlights the distinctive role of each tension in the stability of active interfaces and the nucleation and growth of motility-induced phases.

Capillary waves↗

Characterizing the Effect of Capillary Heterogeneity on Multiphase Flow Pulsation in an Intermediate–Scale Beadpack Experiment using Time Series Clustering and Frequency Analysis

An intermediate-scale beadpack drainage experiment was conducted to investigate how simple layered lamination heterogeneity affects CO 2 flow. Two simple layers of capillary barriers are manually packed in the tank and slow drainage was carried out using analog fluids to mimic the capillary- and gravity-dominated CO 2 upward migration process in deep saline aquifers. Nonwetting phase saturation time series clustering analysis and frequency analysis have been conducted on the experimental data. Additionally, modified invasion percolation numerical simulations were done on a digital model of the beadpack to compare to experimental results. Results show that capillary barriers can lead to strong pulsation behavior, which in turn can cause unexpected early breaching through other barriers. The inlet pressure is found to be able to respond to saturation changes in far regions of the domain, indicating that the wetting phase can transmit pressure changes from the other phase. Although static simulations were not able to capture all the dynamic behavior observed in the experiment, Monte Carlo composite simulation results combining many different realizations can better illustrate how the nonwetting phase will behave in the heterogeneous domain. Furthermore, our results suggest the need for CO 2 storage site selection with preference given to aquifers with more capillary barriers with finer grain sizes to avoid flow pulsation and to retard plume upward migration.

58 GEOSCIENCES↗

Capillary barriers for staged loading of microfluidic devices

Various aspects of the present disclosure are directed toward methods and apparatuses for interacting a first liquid and a second liquid in one or more fluidic channels of a capillary structure. The methods and apparatuses can include providing at least one capillary barrier that positions a meniscus of the first liquid at a fluid-interface region using capillary forces within the capillary structure. Additionally, a path is provided along one of the channels for the second liquid to flow toward the fluid-interface region. Additionally, gas pressure is released, via a gas-outflow port, from the fluid-interface region while flow of the first liquid is arrested. Further, the first liquid and the second liquid contact in the fluid-interface region with the capillary barrier holding the first liquid at the fluid-interface region.

Santiago, Juan G.↗

Plasma facing components with capillary porous system and liquid metal coolant flow

Liquid metal can create a renewable protective surface on plasma facing components (PFC), with an additional advantage of deuterium pumping and the prospect of tritium extraction if liquid lithium (LL) is used and maintained below 450 °C, the temperature above which LL vapor pressure begins to contaminate the plasma. LM can also be utilized as an efficient coolant, driven by the Lorentz force created with the help of the magnetic field in fusion devices. Capillary porous systems can serve as a conduit of LM and simultaneously provide stabilization of the LM flow, protecting against spills into the plasma. Recently, a combination of a fast-flowing LM cooling system with a porous plasma facing wall (CPSF) was investigated [A. Khodak and R. Maingi, Nucl. Mater. Energy 26, 100935 (2021)]. The system takes an advantage of a magnetohydrodynamics velocity profile as well as attractive LM properties to promote efficient heat transfer from the plasma to the LL at low pumping energy cost, relative to the incident heat flux on the PFC. In the case of a disruption leading to excessive heat flux from the plasma to the LM PFCs, LL evaporation can stabilize the PFC surface temperature, due to high evaporation heat and apparent vapor shielding. The proposed CPSF was optimized analytically for the conditions of a fusion nuclear science facility [Kessel et al., Fusion Sci. Technol. 75, 886 (2019)]: 10 T toroidal field and 10 MW/m 2 peak incident heat flux. Finally, computational fluid dynamics analysis confirmed that a CPSF system with 2.5 mm square channels can pump enough LL so that no additional coolant is needed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Facing Components with Capillary Porous System and Liquid Metal Coolant Flow

Liquid metal can create a renewable protective surface on plasma facing components (PFC), with an additional advantage of deuterium pumping and the prospect of tritium extraction if liquid lithium (LL) is used and maintained below 450 C, the temperature above which LL vapor pressure begins to contaminate the plasma. LM can also be utilized as an efficient coolant, driven by the Lorentz force created with the help of the magnetic field in fusion devices. Capillary porous systems can serve as a conduit of LM and simultaneously provide stabilization of the LM flow, protecting against spills into the plasma. Recently a combination of a fast-flowing LM cooling system with a porous plasma facing wall (CPSF) was investigated [Khodak and Maingi (2021)]. The system takes an advantage of a magnetohydrodynamics velocity profile, as well as attractive LM properties to promote efficient heat transfer from the plasma to the LL at low pumping energy cost, relative to the incident heat flux on the PFC. In case of a disruption leading to excessive heat flux from the plasma to the LM PFCs, LL evaporation can stabilize the PFC surface temperature, due to high evaporation heat and apparent vapor shielding. The proposed CPSF was optimized analytically for the conditions of a Fusion Nuclear Science Facility [Kessel et al. (2019)]: 10T toroidal field and 10 MW/m2 peak incident heat flux. Computational fluid dynamics analysis confirmed that a CPSF system with 2.5 mm square channels can pump enough LL so that no additional coolant is needed.

High Heat Flux↗

Dehydration of gas-phase benzyl amine alcohols studied at atmospheric pressure

Gas-phase ion chemistry is a useful approach for the investigation of physical organic chemistry and the study of reactivity, structure, and thermochemical properties of ionic and neutral organic substrates. Herein, one-step dehydration of gas-phase benzyl amine alcohols to give benzazetidines was discovered without the use of catalysts. Mechanistic investigations of the gas-phase dehydration reactions were explored to study the possible influence of charged microdroplet acceleration during electrospray ionization (ESI) and collisions occurring during ion transfer through the atmospheric pressure interface (API) of the mass spectrometer. The product ion distribution was observed to be less sensitive to droplet effects (spray distance and voltage), and temperature of transfer capillary in the API. However, the product ion distribution exhibit high sensitivity to different S-lens radio frequency (RF) voltage of the API, providing evidence that the dehydration reaction is driven by collisions during ion transfer in the API. With this insight, we developed atmospheric pressure thermal dissociation platform that allowed thermal-induced collisions outside of the mass spectrometer when the benzyl amine alcohols are carried through a heated coiled tube. Up to 98% dissociation efficiency was achieved with the coiled tube heated to a temperature of 200 °C, yielding only the desired benzazetidine product. Finally, by performing the atmospheric pressure thermal dissociation experiment outside of the mass spectrometer, we believe it will be straightforward to collect the dehydration product.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical simulation of an atmospheric pressure plasma jet with coaxial shielding gas

A two-dimensional ( r, z ) numerical simulation of the discharge characteristics of an atmospheric pressure plasma jet (APPJ), with coaxial shielding gas, was performed. The helium working gas flowed in a central capillary tube, engulfing a needle electrode powered by 13.7 MHz radio frequency sinusoidal voltage. The N 2 shielding gas flowed in the annular space of a coaxial tube. These gases emerged, in laminar flow, in a 78%N 2 -21%O 2 -1%Ar dry air ambient. The characteristics of the APPJ with shielding gas were compared to those of the APPJ without shielding gas. The nitrogen shielding gas hindered the diffusion of oxygen and argon from the ambient air into the helium jet. With the shielding gas present, more nitrogen penetrated into the helium core, causing a shorter plasma ‘plume’. The flow rates of the working and shielding gas, critically affected the gas temperature, and in turn the discharge characteristics. For a He flow of 2 standard liters per minute (slm), switching on the nitrogen shielding gas flow (at 4.5 slm) reduced the on-axis O 2 and Ar mole fractions from 3.9 × 10 - 4 to 6.8 × 10 - 5 and from 1.9 × 10 - 5 to 3.3 × 10 - 6 , respectively, at an axial distance of 3 mm downstream of the nozzle. The radial profiles of the mole fractions of the ambient gases were monotonically and strongly decreasing towards the system axis, for short axial distances from the nozzle (~1 mm), but became progressively flatter at longer distances from the nozzle (3 mm and 5 mm). Simulation predictions captured the salient features of experimental data of ambient species mole fractions in the plasma jet, and the 706 nm optical emission intensity profiles of the He 3 3 S excited state.

Physics↗

Sockeye Code Validation Against UNIST Heat Pipe - Poster - Internship 2025

Sockeye is an engineering level code being developed under the MOOSE framework for modeling heat pipes. A heat pipe is a sealed tube with a wick structure filled with a working fluid that transfers heat efficiently and passively via phase change of the working fluid. Heat applied to the evaporator end creates a pressure gradient which causes vapor to migrate to the condenser end where the vapor deposits its energy and condenses. Capillary force generated by the wick structure then draws the liquid back to the evaporator. A validation study was performed to compare the Sockeye code against data produced at the Ulsan National Institute of Standards and Technology for a slightly overfilled sodium heat pipe. The heat pipe was operated under natural convection cooling and a decreasing inactive length was observed. The experiment was modeled in Sockeye using the condenser pool model, the front non-condensable gas (NCG) model, and the mixture NCG model separately to reproduce the inactive length phenomenon. Also, a new capability was implemented in MOOSE to allow for conjugate heat transfer from the condenser based on the Churchill-Chu correlation for natural convection. The condenser pool model showed an increasing inactive length, demonstrating that the behavior was likely not caused by a pool of excess liquid. The front NCG model was able to show good agreement with the experiment, but it suffered convergence issues at the front. Finally, the mixture NCG model gave good results when the axial mesh was sufficiently refined. This work culminated in additions to the Sockeye documentation and a contribution to a journal article that will be published later. This poster is a summary of my work which I can take back to my university for presentation.

42 - ENGINEERING↗

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗