Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capillary flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Drying model of a high salt content cementitious waste form: Effect of capillary forces and salt solution

Highlights: • Drying model for a high salt content cementitious waste form is developed. • Water vapor diffusion and capillary liquid flow are distinguished. • Capillary and salt solution effects are considered in vapor-liquid equilibrium. A water transport model coupling capillary liquid flow with vapor diffusion is developed to describe the drying process for a cementitious waste form with high salinity porewater. Vapor-liquid equilibrium is formulated as the driving force for vapor diffusion and the model accounts for pore capillary and high salinity effects on water thermodynamic activity. Pore filling and porewater surface tension as a function of pore size distribution and water saturation have been quantified for the material. Geochemical speciation modeling is used to simulate porewater activity as a function of composition over the range of saturation. The theoretical relationship between relative humidity and water saturation generally agrees with experimental measurement, and the developed model is capable of predicting drying rates under various external relative humidity conditions. The model was developed to be incorporated into reactive transport models considering the effects of drying such as salt redistribution and efflorescence.

36 MATERIALS SCIENCE↗

Study of vapor flow into a capillary acquisition device

An analytical model was developed that prescribes the conditions for vapor flow through the window screen of a start basket. Several original submodels were developed as part of this model. The submodels interrelate such phenomena as the effect of internal evaporation of the liquid, the bubble point change of a screen in the presence of wicking, the conditions for drying out of a screen through a combination of evaporation and pressure difference, the vapor inflow rate across a wet screen as a function of pressure difference, and the effect on wicking of a difference between the static pressure of the liquid reservoir and the surrounding vapor. Most of these interrelations were verified by a series of separate effects tests, which were also used to determine certain empirical constants in the models. The equations of the model were solved numerically for typical start basket designs, and a simplified start basket was constructed to verify the predictions, using both volatile and nonvolatile test liquids. The test results verified the trends predicted by the model.

Dodge, F. T.↗

Vapor flow into a capillary propellant-acquisition device

An analytical model is described that specifies the conditions needed to cause a flow of vapor through the screens of a start basket. The analytical model is composed of several original submodels that interrelate the evaporation of the liquid in the basket, the bubble-point change of a screen in the presence of wicking, the drying out of a screen through a combination of evaporation and pressure difference, the vapor flow rate across a wet screen as a function of pressure difference, and the effect on wicking of a difference between the static pressure of the liquid reservoir and the vapor surrounding the screen. Most of the interrelations were demonstrated by a series of separate-effects tests, which were also used to determine certain empirical constants. The equations of the model were solved numerically for typical start basket designs. A simplified start basket was constructed and tested to verify these predictions, using both volatile and non-volatile liquids. The test results verified the trends predicted by the model.

Dodge, F. T.↗

A Local Condensation Analysis Representing Two-phase Annular Flow in Condenser/radiator Capillary Tubes

NASA's effort for the thermal environmental control of the Space Station Freedom is directed towards the design, analysis, and development of an Active Thermal Control System (ATCS). A two phase, flow through condenser/radiator concept was baselined, as a part of the ATCS, for the radiation of space station thermal load into space. The proposed condenser rejects heat through direct condensation of ATCS working fluid (ammonia) in the small diameter radiator tubes. Analysis of the condensation process and design of condenser tubes are based on the available two phase flow models for the prediction of flow regimes, heat transfer, and pressure drops. The prediction formulas use the existing empirical relationships of friction factor at gas-liquid interface. An attempt is made to study the stability of interfacial waves in two phase annular flow. The formulation is presented of a stability problem in cylindrical coordinates. The contribution of fluid viscosity, surface tension, and transverse radius of curvature to the interfacial surface is included. A solution is obtained for Kelvin-Helmholtz instability problem which can be used to determine the critical and most dangerous wavelengths for interfacial waves.

Karimi, Amir↗

Characterizing the Effect of Capillary Heterogeneity on Multiphase Flow Pulsation in an Intermediate–Scale Beadpack Experiment using Time Series Clustering and Frequency Analysis

An intermediate-scale beadpack drainage experiment was conducted to investigate how simple layered lamination heterogeneity affects CO 2 flow. Two simple layers of capillary barriers are manually packed in the tank and slow drainage was carried out using analog fluids to mimic the capillary- and gravity-dominated CO 2 upward migration process in deep saline aquifers. Nonwetting phase saturation time series clustering analysis and frequency analysis have been conducted on the experimental data. Additionally, modified invasion percolation numerical simulations were done on a digital model of the beadpack to compare to experimental results. Results show that capillary barriers can lead to strong pulsation behavior, which in turn can cause unexpected early breaching through other barriers. The inlet pressure is found to be able to respond to saturation changes in far regions of the domain, indicating that the wetting phase can transmit pressure changes from the other phase. Although static simulations were not able to capture all the dynamic behavior observed in the experiment, Monte Carlo composite simulation results combining many different realizations can better illustrate how the nonwetting phase will behave in the heterogeneous domain. Furthermore, our results suggest the need for CO 2 storage site selection with preference given to aquifers with more capillary barriers with finer grain sizes to avoid flow pulsation and to retard plume upward migration.

58 GEOSCIENCES↗

Study of liquid and vapor flow into a Centaur capillary device

The following areas of liquid and vapor flow were analyzed and experimentally evaluated; 1) the refilling of capillary devices with settled liquid, and 2) vapor flow across wetted screens. These investigations resulted in: 1) the development of a versatile computer program that was successfully correlated with test data and used to predict Centaur D-1S LO2 and LH2 start basket refilling; 2) the development of a semi-empirical model that was only partially correlated with data due to difficulties in obtaining repeatable test results. Also, a comparison was made to determine the best propellant management system for the Centaur D-1S vehicle. The comparison identified the basline Centaur D-1S system (using pressurization, boost pumps and propellant settling) as the best candidate based on payload weight penalty. However, other comparison criteria and advanced mission condition were identified where pressure fed systems, thermally subcooled boost pumps and capillary devices would be selected as attractive alternatives.

Blatt, M. H.↗

The impact of capillary heterogeneity on CO 2 flow and trapping across scales

Capillary heterogeneity has been identified over the last decade as a key control on subsurface CO 2 flow behavior during geological CO 2 sequestration. These heterogeneities can be formed in all sedimentary rocks, ranging from slight variations in the sand grain sizes to extensive sequences of interbedded sands, shales, and limestones. Capillary heterogeneity has been largely, although not entirely, overlooked in subsurface flow modeling because it is assumed to only directly influence fluid redistribution over scales of centimeters to meters. However, even small-scale fluid movements can result in dramatic impacts on the mobility and trapping of the CO 2 over kilometers. Therefore, neglecting capillary heterogeneity at multiple scales could potentially lead to errors in modeling and predicting field-scale plume migration. In this review paper, we aim to provide a consistent overview to (1) establish that capillary heterogeneity can have a major impact on CO 2 plume migration, (2) establish the respective length scales at which capillary heterogeneity matters, and (3) provide guidance for numerical modeling. This review covers pertinent literature and extracts key observations from the core to the field scales. Experimental studies have shown that millimeter-decimeter scale capillary heterogeneity can cause the so-called capillary heterogeneity trapping in addition to pore-scale residual trapping. Even at such a small scale, capillary heterogeneity can already lead to complex upscaled constitutive relationships, such as flow-rate dependent and anisotropic relative permeability, which affects field-scale CO 2 migration even when field-scale heterogeneities are present. Under gravity-dominated flow regimes, centimeter-meter scale capillary heterogeneity can entrap a significant amount of CO 2 at field scale, not just after imbibition but also during drainage. In certain cases, the presence of capillary heterogeneity can even completely stop the vertical movement of the CO 2 plume, hence greatly reducing leakage risks. At meter-kilometer scale, the influence of capillary heterogeneity is more pronounced and can hinder or redirect CO 2 migration in both lateral and vertical directions. The impact of capillary heterogeneity across multiple spatial scales poses a great challenge in modeling CO 2 migration at field scale, because it is practically impossible to build a field-scale earth model with grid blocks at millimeter scale. We recommend a hierarchical modeling approach to address this challenge. At field scale, earth models are built to capture geological features and heterogeneities in high but still practical grid resolutions. For each facies or rock type of the field-scale model, high- resolution meter-scale “conceptual” models are built with millimeter-scale grid blocks to capture representative fine-scale bedding geometries and heterogeneities in various environments of deposition, bridging the gap from subcore scale to the size of a field-scale simulation grid block. Upscaling is then used to preserve the smaller-scale flow dynamics of various rock types in field-scale simulations. Here, future work is needed to (1) refine, improve, and validate the hierarchical modeling approach; (2) build libraries of fine-scale bedding models for facies in various environments of deposition; (3) quantify multiscale capillary heterogeneity effects under subsurface uncertainties; (4) gain learning from different storage formations; and (5) establish best practices that balance accuracy and computational speed.

Capillary heterogeneity↗

A new linearized theory of laminar film condensation of two phase annular flow in a capillary pumped loop

Future large space based facilities, such as Space Station, will require energy management systems capable of transporting tens of kilowatts of heat over a hundred meters or more. This represents better than an order of magnitude improvement over current technology. Two-phase thermal systems are currently being developed to meet this challenge. Condensation heat transfer plays a very important role in this system. The present study attempts an analytic solution to the set of linearized partial differential equations. The axial velocity and temperature functions were found to be Bessel functions which have oscillatory behavior. This result agrees qualitatively with the experimental evidence from tests at both NASA Goddard Space Flight Center and elsewhere.

Hsu, Y. K.↗

Capillary electrophoresis: Imaging of electroosmotic and pressure driven flow profiles in fused silica capillaries

This study is a continuation of the summer of 1994 NASA/ASEE Summer Faculty Fellowship Program. This effort is a portion of the ongoing work by the Biophysics Branch of the Marshall Space Flight Center. The work has focused recently on the separation of macromolecules using capillary electrophoresis (CE). Two primary goals were established for the effort this summer. First, we wanted to use capillary electrophoresis to study the electrohydrodynamics of a sample stream. Secondly, there was a need to develop a methodology for using CE for separation of DNA molecules of various sizes. In order to achieve these goals we needed to establish a procedure for detection of a sample plug under the influence of an electric field Detection of the sample with the microscope and image analysis system would be helpful in studying the electrohydrodynamics of this stream under load. Videotaping this process under the influence of an electric field in real time would also be useful. Imaging and photography of the sample/background electrolyte interface would be vital to this study. Finally, detection and imaging of electroosmotic flow and pressure driven flow must be accomplished.

Williams, George O., Jr.↗

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen↗

Measurements of He-Ar, He-N 2 , and He-air thermal creep slip and accommodation coefficients at high temperatures

Understanding gas flows in capillaries has many applications in modeling the transport of gases in nano-structured, porous, or fractured media. A network of capillaries can often approximate these media, and also information on gas-surface interactions obtained from capillary experiments can be used for modeling flows in these media. Experimental data on flows of different mixtures of He-Ar, He-N 2 , and He-air in the slip regime and in stainless steel capillaries at high temperatures were obtained by using a two-bulb apparatus. An accurate expression for the thermal creep slip coefficients with the Lennard-Jones potential parameters and diffuse-specular reflection gas-surface interaction conditions were then used to obtain the accommodation coefficients for the different gases. The experimental data are best described with values of accommodation coefficients in the range of 0.1–0.3 for He and 0.5–1.0 for Ar, N 2 , and air. Further, the use of values in this range is suggested for modeling gaseous flows in capillaries and nano-structured, porous, or fractured media if other direct measured values for a particular medium are unavailable.

42 ENGINEERING↗

Dynamics of electromechanical flow structures.

Free-surface gravity flows and capillary wicking provide examples of flow structures with fluid partially ducted at free surfaces by external forces. Wall-less electromechanical flow structures are developed which have a similar nature, but with polarization forces providing the orientation at free surfaces. Like their mechanical counterparts, these have the ability to ingest liquid or expel vapor through their walls. The structures consist of electrodes running in the flow direction z with slowly varying cross sections in a plane transverse to the flow. A formulation is given of the long-wave nonlinear (principal mode) dynamics, with use made of energy functions to represent a broad class of possible mechanical and electrical structure geometries.

Jones, T. B., Jr.↗

Dissipative heating effects and end corrections for viscous Newtonian flow in high shear capillary tube viscometry

The effect of dissipation heating on the apparent viscosity measured in capillary tube viscometry is described in this paper. Conditions of low Reynolds number and high shear are assumed. End corrections to the tube flow are incorporated. The flow curves show decreasing apparent viscosity when the shear stress increases. The configuration of the flow curves plotted in logarithmic presentation are found to be identical for fluids with Newtonian behavior. Convection is the predominant mechanism in removal of the heat in short capillary tube. The estimated upper bound for the shear stress obtainable in short length capillary tubes appears to be of the order of magnitude of 10 MPa limited primarily by the pressure drop associated with the constant end correction from the flat ended inlet and exit of the tube.

Jakobsen, J.↗

The Dynamics of Miscible Interfaces: Simulations

The goal of this experimental/computational investigation (joint with Prof Maxworthy at USC) has been to study the dynamics of miscible interfaces, both from a scientific and a practical point of view, and to prepare a related experiment to be flown on the International Space Station. In order to address these effects, we have focused experimental and computational investigations on miscible displacements in cylindrical capillary tubes, as well as in Hele-Shaw cells. Regarding the flow in a capillary tube, the question was addressed as to whether Korteweg stresses and/or divergence effects can potentially account for discrepancies observed between conventional Stokes flow simulations and experiments for miscible flows in capillary tubes. An estimate of the vorticity and streamfunction fields induced by the Kortewegs stresses was derived, which shows these stresses to result in the formation of a vortex ring structure near the tip of the concentration front. Through this mechanism the propagation velocity of the concentration front is reduced, in agreement with the experimental observations. Divergence effects, on the other hand, were seen to be very small, and they have a negligible influence on the tip velocity. As a result, it can be concluded that they are not responsible for the discrepancies between experiments and conventional Stokes simulations. A further part of our investigation focussed on the development of high-accuracy three-dimensional spectral element simulation techniques for miscible flows in capillary tubes, including the effects of variable density and viscosity. Towards this end, the conservation equations are treated in cylindrical coordinates.

Meiburg, Eckart↗