Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evaluation of Low-cost, Full HD, CMOS Cameras for Use in the Calcine Retrieval Project - 19530

This paper describes results from radiation testing conducted on low-cost, commercial off-the-shelf, full high-definition (HD) resolution (1920 x 1080 p), complementary metal-oxide-semiconductor (CMOS) camera sensors. The purpose of the testing was to evaluate the sensors' suitability for use in the Calcine Retrieval Project by determining their image quality and life expectancy while operating in an ionizing radiation field of 20.0 Gy/h. The two camera sensors tested were the Axis FA1105 and Axis FA1125. These commercial camera sensors were designed for retail security surveillance and have no radiation-hardened (rad-hard) components. In addition to radiation testing, the sensors' field-of-view, resolution, and low-light image quality were tested at several target distances to ensure they meet project requirements. Testing was divided into two phases. During Phase 1, four FA1105 sensors and four FA1125 sensors were tested simultaneously without any shielding in radiation fields of 25.5 Gy/h and 49.3 Gy/h. In Phase 2, three FA1105 and five FA1125 sensors were shielded by 22.2 mm of lead and tested simultaneously in radiation fields of 26.8 Gy/h, 52.3 Gy/h, 143.0 Gy/h, 200.7 Gy/h, 404.6 Gy/h, and 2,317.5 Gy/h. Dose rate values were established using film dosimetry readings. Apertures in the shielding allowed for a 40-degree field of view while shielding all parts of the sensor except for directly in front of the CMOS sensor array. All testing was conducted at the Idaho Accelerator Center in Pocatello, Idaho, using a 450 keV X-ray generator. Sensor images were automatically captured at regular intervals throughout the testing for qualitative evaluation by the test team. Film dosimetry was placed near the sensors to record actual dose totals. The 450 keV setting generates X-ray radiation with an energy level close to the primary gamma energy level produced by the Cesium-137 isotope in the calcine, which is 662 keV. Results from Phase 1 indicate the sensors failed at an average cumulative dose of 226.3 Gy. For a given 20.0 Gy/h field this results in a mean time to failure (MTTF) of 11.3 hours. Recorded images from all sensors showed minimal image degradation due to radiation-induced noise. When the sensors finally failed, the failure mode was an abrupt loss of video. The image went black suggesting some other component in the sensor head besides the CMOS sensor array was responsible for the failure. During a portion of Phase 1 testing, a commercial, rad-hard camera was irradiated in the 25.5 Gy/h field along with the eight Axis FA series sensors. Image quality from the FA series sensors significantly outperformed the image quality of the rad-hard camera in radiation-induced noise tolerance, image resolution, and dynamic range. During Phase 2 testing, all sensors produced excellent images in radiation fields as high as 404.6 Gy/h. One FA1125 sensor was tested at the highest dose rate of 2,317.5 Gy/h. At this dose rate, the image was color shifted towards red and contained a significant amount radiation-induced noise. The sensor did not fail and was producing usable imagery after one hour, at which time the test was ended due to allotted beam-time at the test facility. Eighteen hours after X-rays were shut off, the sensor image returned to normal color and all eight sensors continued to operate without any visible, permanent image degradation. For Phase 2 testing, it was not possible to establish a MTTF since none of the shielded sensors failed during the allotted test time. However, given the highest cumulative dose of 4,142.1 Gy received by a shielded FA1125 sensor, a minimum life expectancy of 207 hours (8.6 days) is predicted while operating in a 20.0 Gy/h field. Test results indicate the radiation tolerance of the FA series sensor's CMOS array, along with the small form factor, full HD image quality, wide dynamic range, and Ethernet standard makes it suitable for short-term use in monitoring and visually documenting waste remediation efforts for the Calcine Retrieval Project at the INL. The sensor's low-cost of about $140 US, compared to commercial rad-hard cameras costing between $5,000 and $7,000 US each, allow them to be used as an affordable, disposable resource for many short-duration, radioactive waste remediation efforts where decontamination of an expensive, commercial rad-hard camera is undesirable or not possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time-resolved measurements of liquid–vapor thermal interactions throughout the full life-cycle of sliding bubbles at subcooled flow boiling conditions

The local thermal response of the liquid phase to the presence of sliding bubbles was measured with an infrared camera in subcooled flow-boiling conditions. These measurements were complemented with two high-speed cameras to capture the corresponding bubbles’ dynamics. The liquid–vapor interactions were captured in detail over the full life-cycle of sliding bubbles. Four distinctive phases for the bubble life-cycle were identified: A) Spherical bubble growth with strong attachment, B) Deformed bubble growth with weak attachment, C) Detachment with hot liquid quenching, and D) Cold liquid quenching. Here, to the best of the authors’ knowledge, it is the first time that the “detachment with hot liquid quenching phase has been observed. This phase is characterized by a “hot” thermal footprint during the bubble detachment process. It is believed that this footprint is constituted partially from hot liquid released during the condensation of the recently detached bubble, and from released hot fluid previously collected by the bubble during sliding. In addition, this work reveals that using traditional high-speed visualization techniques (side-view camera only) can lead to an underestimation of approximately 40% of the actual bubble–wall contact diameter (dc) which was inferred from the infrared camera measurements.

42 ENGINEERING↗

On the response of rubbers at high strain rates.

In this report, we examine the propagation of tensile waves of finite deformation in rubbers through experiments and analysis. Attention is focused on the propagation of one-dimensional dispersive and shock waves in strips of latex and nitrile rubber. Tensile wave propagation experiments were conducted at high strain-rates by holding one end fixed and displacing the other end at a constant velocity. A high-speed video camera was used to monitor the motion and to determine the evolution of strain and particle velocity in the rubber strips. Analysis of the response through the theory of finite waves and quantitative matching between the experimental observations and analytical predictions was used to determine an appropriate instantaneous elastic response for the rubbers. This analysis also yields the tensile shock adiabat for rubber. Dispersive waves as well as shock waves are also observed in free-retraction experiments; these are used to quantify hysteretic effects in rubber.

36 MATERIALS SCIENCE↗

High energy X-ray pinhole imaging at the Z facility

A new high photon energy (hν > 15 keV) time-integrated pinhole camera (TIPC) has been developed as a diagnostic instrument at the Z facility. This camera employs five pinholes in a linear array for recording five images at once onto an image plate detector. Each pinhole may be independently filtered to yield five different spectral responses. The pinhole array is fabricated from a 1-cm thick tungsten block and is available with either straight pinholes or conical pinholes. Each pinhole within the array block is 250 μm in diameter. The five pinholes are splayed with respect to each other such that they point to the same location in space, and hence present the same view of the radiation source at the Z facility. The fielding distance from the radiation source is 66 cm and the nominal image magnification is 0.374. Initial experimental results from TIPC are shown to illustrate the performance of the camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the relationship between noise transfer inside the x-ray framing cameras and their imaging ability

We apply a cascaded linear model analysis to a micro-channel plate x-ray framing camera. We establish a theoretical expression of the Noise Power Spectrum (NPS) at the detector’s output and assess its accuracy by comparing it to the NPS of Monte Carlo simulations of the detector’s response to a uniform illumination. We also reflect that fitting the NPS of experimental data against a parametric model based on this expression can yield valuable information on the imaging ability of framing cameras, offering an alternative method to the usual avenue employed to measure their modulation transfer functions.

25 ENERGY STORAGE↗

MO-A-BRD-01: An Investigation of the Dynamic Response of a Novel Acousto-Optic Liquid Crystal Detector for Full-Field Transmission Ultrasound Breast Imaging

Purpose: To characterize the dynamic response of a novel acousto-optic (AO) liquid crystal detector for high-resolution transmission ultrasound breast imaging. Transient and steady-state lesion contrast were investigated to identify optimal transducer settings for our prototype imaging system consistent with the FDA limits of 1 W/cm{sup 2} and 50 J/cm{sup 2} on the incident acoustic intensity and the transmitted acoustic energy flux density. Methods: We have developed a full-field transmission ultrasound breast imaging system that uses monochromatic plane-wave illumination to acquire projection images of the compressed breast. The acoustic intensity transmitted through the breast is converted into a visual image by a proprietary liquid crystal detector operating on the basis of the AO effect. The dynamic response of the AO detector in the absence of an imaged breast was recorded by a CCD camera as a function of the acoustic field intensity and the detector exposure time. Additionally, a stereotactic needle biopsy breast phantom was used to investigate the change in opaque lesion contrast with increasing exposure time for a range of incident acoustic field intensities. Results: Using transducer voltages between 0.3 V and 0.8 V and exposure times of 3 minutes, a unique one-to-one mapping of incident acoustic intensity to steady-state optical brightness in the AO detector was observed. A transfer curve mapping acoustic intensity to steady-state optical brightness shows a high-contrast region analogous to the linear portion of the Hurter-Driffield curves of radiography. Using transducer voltages between 1 V and 1.75 V and exposure times of 90 s, the lesion contrast study demonstrated increasing lesion contrast with increasing breast exposure time and acoustic field intensity. Lesion-to-background contrast on the order of 0.80 was observed. Conclusion: Maximal lesion contrast in our prototype system can be obtained using the highest acoustic field intensity and the longest breast exposure time allowable under FDA standards. Department of Defense (DOD) Breast Cancer Research Program IDEA Award W81XWH-11-1-0332; National Institutes of Health (NIH) Grant T32 EB002103-21 from the National Institute of Biomedical Imaging and Bioengineering (NIBIB)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oak Ridge Site Specific Advisory Board Adapts To Engage - 16459

Environmental Management (EM) Site Specific Advisory Boards (SSABs) are representative of their communities and exist for the purpose of advising DOE EM. As such they are the conduits between the public and the DOE EM. To remain relevant to the community they cannot exist in a vacuum and the public needs to be aware of the Boards' function, purpose, and progress and have opportunities for input. Since the SSABs generally deal with fairly complex issues related to environmental cleanup, and the members of the Boards represent a diversity of background, there are many challenges associated with informing and eliciting input from Board members as well as informing and engaging the public. To that end, Oak Ridge SSAB (ORSSAB) has instituted changes to facilitate Board and public engagement. As the ORSSAB has matured and the work has become routine, it has become a challenge to keep members interested and invested. So the Board asks its members to provide input on how to make the process better. Through our annual member surveys and facilitated meetings, we query the board for ideas, and the results of these surveys and meetings are discussed at the annual planning meetings. Agreed changes are instituted in the following year. Recently the ORSSAB has instituted positive changes in the meeting structure, locations, and content. There are fewer formal meetings and these meetings are shorter. The board has also incorporated field trips to specific sites prior to presentations on those areas to further enhance membership understanding of the problems at hand, site conditions, and enormity and scope of the work to be undertaken. Changes of meeting location have occurred. Instead of the standard meeting room, the ORSSAB has met at local restaurants (in private rooms) where food service is available, and the atmosphere is more relaxed and informal. This gives members an opportunity to interact with each other rather than sitting in designated places at a formal meeting with video cameras rolling. Not only are the members more at ease, the presenters are more relaxed in their response to questions. Open discussion sessions have also been added to the meeting agendas. The ORSSAB participates in both public outreach and public engagement. Public outreach activities have included: presentations to local citizens groups; televising meetings on public access cable channels in three local communities; publishing The Advocate, a quarterly newsletter; and recently setting up and maintaining a Facebook page. Activities related to public engagement included the Board's participation at a DOE-sponsored community budget workshop. The ORSSAB strives for value and relevancy, attempting to convey a clear message to the community and to DOE. It also strives to inform its membership in a way that allows for clarity of understanding, and above all it tries to be enjoyable to its membership. The ORSSAB listens to its membership and has evolved its process to allow for effective advocacy. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)↗

Influencing Activity of Bats by Dimly Lighting Wind Turbine Surfaces with Ultraviolet Light

Wind energy producers need deployable devices for wind turbines that prevent bat fatalities. Based on the speculation that bats approach turbines after visually mistaking them for trees, we tested a potential light-based deterrence method. It is likely that the affected bats see ultraviolet (UV) light at low intensities. Here, we present the results of a multi-month experiment to cast dim, flickering UV light across wind turbine surfaces at night. Our objectives were to refine and test a practical system for dimly UV-illuminating turbines while testing whether the experimental UV treatment influenced the activity of bats, birds, and insects. We mounted upward-facing UV light arrays on turbines and used thermal-imaging cameras to quantify the presence and activity of night-flying animals. The results demonstrated that the turbines can be lit to the highest reaches of the blades with “invisible” UV light, and the animal responses to such experimental treatment can be concurrently monitored. The UV treatment did not significantly change nighttime bat, insect, or bird activity at the wind turbine. Our findings show how observing flying animals with thermal cameras at night can help test emerging technologies intended to variably affect their behaviors around wind turbines.

17 WIND ENERGY↗

Antenna-coupled TES bolometers used in BICEP2, Keck Array, and Spider

We have developed antenna-coupled transition-edge sensor bolometers for a wide range of cosmic microwave background (CMB) polarimetry experiments, including Bicep2, Keck Array, and the balloon borne Spider. These detectors have reached maturity and this paper reports on their design principles, overall performance, and key challenges associated with design and production. Our detector arrays repeatedly produce spectral bands with 20%–30% bandwidth at 95, 150, or 230 GHz. The integrated antenna arrays synthesize symmetric co-aligned beams with controlled side-lobe levels. Cross-polarized response on boresight is typically ∼0.5%, consistent with cross-talk in our multiplexed readout system. End-to-end optical efficiencies in our cameras are routinely 35% or higher, with per detector sensitivities of NET ∼ 300 μK{sub CMB}√s. Thanks to the scalability of this design, we have deployed 2560 detectors as 1280 matched pairs in Keck Array with a combined instantaneous sensitivity of ∼9 μK{sub CMB}√s, as measured directly from CMB maps in the 2013 season. Similar arrays have recently flown in the Spider instrument, and development of this technology is ongoing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-MGy Radiation Hardened Camera for Nuclear Facilities

There is an increasing interest in developing cameras for surveillance systems to monitor nuclear facilities or nuclear waste storages. Particularly, for today's and the next generation of nuclear facilities increasing safety requirements consecutive to Fukushima Daiichi's disaster have to be considered. For some applications, radiation tolerance needs to overcome doses in the MGy(SiO{sub 2}) range whereas the most tolerant commercial or prototypes products based on solid state image sensors withstand doses up to few kGy. The objective of this work is to present the radiation hardening strategy developed by our research groups to enhance the tolerance to ionizing radiations of the various subparts of these imaging systems by working simultaneously at the component and system design levels. Developing radiation-hardened camera implies to combine several radiation-hardening strategies. In our case, we decided not to use the simplest one, the shielding approach. This approach is efficient but limits the camera miniaturization and is not compatible with its future integration in remote-handling or robotic systems. Then, the hardening-by-component strategy appears mandatory to avoid the failure of one of the camera subparts at doses lower than the MGy. Concerning the image sensor itself, the used technology is a CMOS Image Sensor (CIS) designed by ISAE team with custom pixel designs used to mitigate the total ionizing dose (TID) effects that occur well below the MGy range in classical image sensors (e.g. Charge Coupled Devices (CCD), Charge Injection Devices (CID) and classical Active Pixel Sensors (APS)), such as the complete loss of functionality, the dark current increase and the gain drop. We'll present at the conference a comparative study between these radiation-hardened pixel radiation responses with respect to conventional ones, demonstrating the efficiency of the choices made. The targeted strategy to develop the complete radiation hard camera electronics will be exposed. Another important element of the camera is the optical system that transports the image from the scene to the image sensor. This arrangement of glass-based lenses is affected by radiations through two mechanisms: the radiation induced absorption and the radiation induced refractive index changes. The first one will limit the signal to noise ratio of the image whereas the second one will directly affect the resolution of the camera. We'll present at the conference a coupled simulation/experiment study of these effects for various commercial glasses and present vulnerability study of typical optical systems to radiations at MGy doses. The last very important part of the camera is the illumination system that can be based on various technologies of emitting devices like LED, SLED or lasers. The most promising solutions for high radiation doses will be presented at the conference. In addition to this hardening-by-component approach, the global radiation tolerance of the camera can be drastically improve by working at the system level, combining innovative approaches eg. for the optical and illumination systems. We'll present at the conference the developed approach allowing to extend the camera lifetime up to the MGy dose range. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Co-occurrence of native white-tailed deer and invasive wild pigs: Evidence for competition?

Understanding whether invasive and native species compete for shared resources where they co-occur is essential for mitigating the negative impacts of invasive species on native ecosystems. Here, we examined how the presence and density of an invasive species, wild pigs (Sus scrofa), affect native white-tailed deer (Odocoileus virginianus; hereafter, deer) on the Savannah River Site, SC, USA. We examined potential changes in deer areas of use, temporal overlap, and occupancy to evaluate the effects of wild pig occurrence and density on deer space use, diel activity, and co-occurrence with wild pigs across 9 months during 2018 and 2019. Wild pig density had the strongest effect on deer space use in high- and moderate-use areas. Declines in deer space use in response to wild pig density were most pronounced in March and October 2018 and April 2019 for females, while male space use declined in response to wild pig density in October and December 2018. Both species were largely nocturnal with high overlap in diel activity across months. Deer occupancy responses to wild pig density varied across months, with negative responses in May and October 2018 and positive responses in July 2018 and April 2019. Deer and wild pigs co-occurred at 30%–59% of camera stations across months, with broadscale co-occurrence patterns being unaffected by changes in shared cover or wild pig occurrence. Overall, our results suggest that deer make fine-scale behavioral adjustments to avoid wild pigs, providing evidence that competition is likely occurring even where wild pig density is relatively low. Such fine-scale behavioral plasticity in deer appears to mitigate the costs of competition with wild pigs and may be a mechanism enabling long-term co-existence of deer and wild pigs. Our study provides novel insight on the complexities of spatiotemporal relationships between invasive wild pigs and native deer and suggests that the negative effects of interactions between deer and wild pigs may be more pronounced when deer life history needs are particularly demanding. In areas where eradication of invasive wild pigs may be impossible, maintaining low wild pig densities may help mitigate, but may not eliminate, the negative effects of wild pigs on deer.

resource partitioning↗

High Dose-Per-Fraction Irradiation of Limited Lung Volumes Using an Image-Guided, Highly Focused Irradiator: Simulating Stereotactic Body Radiotherapy Regimens in a Small-Animal Model

Purpose: To investigate the underlying biology associated with stereotactic body radiotherapy (SBRT), both in vivo models and image-guided, highly focal irradiation systems are necessary. Here, we describe such an irradiation system and use it to examine normal tissue toxicity in a small-animal model at lung volumes similar to those associated with human therapy. Methods and Materials: High-dose radiation was delivered to a small volume of the left lung of C3H/HeJCr mice using a small-animal stereotactic irradiator. The irradiator has a collimation mechanism to produce focal radiation beams, an imaging subsystem consisting of a fluorescent screen coupled to a charge-coupled device camera, and a manual positioning stage. Histopathologic examination and micro-CT were used to evaluate the radiation response. Results: Focal obliteration of the alveoli by fibrous connective tissue, hyperplasia of the bronchiolar epithelium, and presence of a small number of inflammatory cells are the main reactions to low-volume/high-dose irradiation of the mouse lung. The tissue response suggested a radiation dose threshold for early phase fibrosis lying between 40 and 100 Gy. The irradiation system satisfied our requirements of high-dose-rate, small beam diameter, and precise localization and verification. Conclusions: We have established an experimental model and image-guided animal irradiation system for the study of high dose per fraction irradiations such as those used with SBRT at volumes analogous to those used in human beings. It will also allow the targeting of specific anatomical structures of the thorax or ultimately, orthotopic tumors of the lung.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single crystal diamond detector measurements of deuterium-deuterium and deuterium-tritium neutrons in Joint European Torus fusion plasmas

First simultaneous measurements of deuterium-deuterium (DD) and deuterium-tritium neutrons from deuterium plasmas using a Single crystal Diamond Detector are presented in this paper. The measurements were performed at JET with a dedicated electronic chain that combined high count rate capabilities and high energy resolution. The deposited energy spectrum from DD neutrons was successfully reproduced by means of Monte Carlo calculations of the detector response function and simulations of neutron emission from the plasma, including background contributions. The reported results are of relevance for the development of compact neutron detectors with spectroscopy capabilities for installation in camera systems of present and future high power fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional AXUV-based radiated power density diagnostics on NSTX-U

A new set of radiated-power-density diagnostics for the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak have been designed to measure the two-dimensional poloidal structure of the total photon emissivity profile in order to perform power balance, impurity transport, and magnetohydrodynamic studies. Multiple AXUV-diode based pinhole cameras will be installed in the same toroidal angle at various poloidal locations. The local emissivity will be obtained from several types of tomographic reconstructions. The layout and response expected for the new radially viewing poloidal arrays will be shown for different impurity concentrations to characterize the diagnostic sensitivity. The radiated power profile inverted from the array data will also be used for estimates of power losses during transitions from various divertor configurations in NSTX-U. The effect of in-out and top/bottom asymmetries in the core radiation from high-Z impurities will be addressed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Images of the laser entrance hole from the static x-ray imager at NIF

The static x-ray imager at the National Ignition Facility is a pinhole camera using a CCD detector to obtain images of Hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters, combined with the CCD response, allow recording images in the x-ray range of 3-5 keV with 60 {mu}m spatial resolution. The routines used to obtain the apparent size of the backlit LEH and the location and intensity of beam spots are discussed and compared to predictions. A new soft x-ray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition Hohlraum) is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MEMS terahertz-to-infrared band converter using frequency selective planar metamaterial

A MEMS terahertz-to-infrared converter has been developed based on the unique properties of metamaterials that allow for selective control of the absorptivity and emissivity of the sensors. The converter consists of a sensing element structurally made of planar metamaterial membranes, connected to a substrate frame by four symmetrically-located thermal insulators. Upon THz absorption, the temperature of the sensing element increases and the outward infrared flux from the backside of the element is read by a commercial long-wave infrared camera. Two configurations were designed and fabricated with metamaterial absorptivity optimized for 3.8THz and 4.75THz quantum cascade lasers. The first sensor, fabricated with an oxidized aluminum backside, exhibits higher responsivity, but lower conversion efficiency than the second sensor, fabricated with a metamaterial backside. The spectral characteristics of the metamaterial on the two sides can be optimized to improve both responsivity and sensitivity, while keeping the sensors’ thermal time constant sufficiently small for real time imaging. No dedicated electronics or optics are required for readout making metamaterial-based MEMS THz-to-IR converters very attractive for THz imaging as means of a simple attachment to commercial IR cameras.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thomson spectrometer-microchannel plate assembly calibration for MeV-range positive and negative ions, and neutral atoms

We report on the absolute calibration of a microchannel plate (MCP) detector, used in conjunction with a Thomson parabola spectrometer. The calibration delivers the relation between a registered count numbers in the CCD camera (on which the MCP phosphor screen is imaged) and the number of ions incident on MCP. The particle response of the MCP is evaluated for positive, negative, and neutral particles at energies below 1 MeV. As the response of MCP depends on the energy and the species of the ions, the calibration is fundamental for the correct interpretation of the experimental results. The calibration method and arrangement exploits the unique emission symmetry of a specific source of fast ions and atoms driven by a high power laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗