Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Human-in-the-loop Sensing and Control for Commercial Building Energy Efficiency and Occupant Comfort

Most of the existing heating, ventilation and air conditioning (HVAC) systems in commercial buildings operate in a conservative manner by assuming maximum occupancy in each room during pre-specified periods of the week, leading to significant energy being wasted as rooms are over-conditioned compared to the actual requirements of the occupants. Though critical, our understanding of occupancy patterns and thermal comfort needs of the occupants in commercial buildings is lacking and it is well known that both of these quantities are stochastic and time-varying, thus requiring sensing solutions to estimate them. This project had the goal of designing, implementing and evaluating a hardware and software solution to ameliorate this challenge. In particular, a depth camera (one whose pixels reveal distance from the camera as opposed to color values) placed on doorways is used to detect entrance and exit events from thermal zones in the building, and thereby estimate their occupancy levels. This information is then fed to a novel control algorithm that can, through interactions with the HVAC system, learn how to provide control inputs that maximize comfort and minimize energy waste. The resulting system represents a significant improvement over existing controllers for commercial HVAC systems and allowed us to improve our understanding of the design of future human-in-the-loop control solutions. For this solution to be feasible, the project had target metrics for its performance and cost. In particular, entrance and exit events for occupants moving about the building would need to be detected with an accuracy higher than 97%; and the resulting control inputs derived from this information would need to lead to approximately 10% energy savings compared to a schedule-based controller. Furthermore, regarding the final hardware design, the project had a target bill of materials (BOM) cost for the sensing solution of less than US$200 per unit while using less than 25W of power on average. All of these target metrics were met or exceeded by our final proposed solution. We performed evaluations by deploying the system in over 20 rooms of different types across 6 commercial buildings in Pittsburgh, PA over the course of three years, and performing targeted controlled experiments to test its performance along the different metrics. The human-in-the-loop control solutions (both hardware and software) developed through this project are expected to lead to significant improvements in the comfort and energy efficiency of HVAC systems used in commercial buildings. The insights we developed through the project pave the way to HVAC systems that can condition interior spaces according to their real-time utilization and the thermal comfort needs of the occupants, thereby reducing energy use. They also open up a new learning-based way of configuring HVAC controllers without having to manually fine-tune them for each building. These innovations can significantly increase the adoption of novel control solutions by the industry and thereby save resources and reduce costs of operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Imaging on Z LDRD: Design and Development of Self-Emission and Debris Imagers

We present an overview of the design and development of optical self-emission and debris imaging diagnostics for the Z Machine at Sandia National Laboratories. These diagnostics were designed and implemented to address several gaps in our understanding of visibly emitting phenomenon on Z and the post-shot debris environment. Optical emission arises from plasmas that form on the transmission line that delivers energy to Z loads and on the Z targets themselves; however, the dynamics of these plasmas are difficult to assess without imaging data. Addressing this, we developed a new optical imager called SEGOI (Self-Emission Gated Optical Imager) that leverages the eight gated optical imagers and two streak cameras of the Z Line VISAR system. SEGOI is a low cost, side-on imager with a 1 cm field of view and 30-50 µm spatial resolution, sensitive to green light (540-600 nm). This report outlines the design considerations and development of this diagnostic and presents an overview of the first diagnostic data acquired from four experimental campaigns. SEGOI was fielded on power flow experiments to image plasmas forming on and between transmission lines, on an inertial confinement fusion experiment called the Dynamic Screw Pinch to image low density plasmas forming on return current posts, on an experiment designed to measure the magneto Rayleigh-Taylor instability to image the instability bubble trajectory and self-emission structures, and finally on a Magnetized Liner Inertial Fusion (MagLIF) experiment to image the emission from the target. The second diagnostic developed, called DINGOZ (Debris ImagiNG on Z), was designed to improve our understanding of the post-shot debris environment. DINGOZ is an airtight enclosure that houses electronics and batteries to operate a high-speed (10-400 kfps) camera in the Z Machine center section. We report on the design considerations of this new diagnostic and present the first high-speed imaging data of the post-shot debris environment on Z.

42 ENGINEERING↗

Infrared MBE-Grown HgCdTe Focal Plane Arrays and Cameras After High Energy Neutron Irradiation

HgCdTe is one of the most important materials for the fabrication of infrared detectors and focal plane arrays (FPAs) deployed in environments where high-energy particles, such as protons and neutrons, are present. We designed and fabricated HgCdTe-based FPAs that can be used in high neutron radiation environments and we measured their characteristics. The influence of the radiation on the infrared FPAs and cameras is investigated. HgCdTe material and devices are capable of maintaining high performances in a high energy neutron irradiation environment. For MWIR FPA directly facing a $2.59 × 10^8$ n/cm$^2$ s neutron flux beam (with the highest energy 66 MeV) for 1 h, the noise equivalent differential temperature (NEDT) increased ~8 times after irradiation. However, NEDT decreased to 33 mK (compared to the original value of 21 mK) after one warming-up (to room temperature) and cooling-down cycle. The NEDT for the MWIR FPAs mounted parallel to the beam did not degrade (16 mK and 28 mK before irradiation, changed to 18 mK and 26 mK after irradiation, respectively).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ePix10k 2-megapixel hard X-ray detector at LCLS

The ePix10ka2M (ePix10k) is a new large area detector specifically developed for X-ray free-electron laser (XFEL) applications. The hybrid pixel detector was developed at SLAC to provide a hard X-ray area detector with a high dynamic range, running at the 120 Hz repetition rate of the Linac Coherent Light Source (LCLS). The ePix10k consists of 16 modules, each with 352 × 384 pixels of 100 µm × 100 µm distributed on four ASICs, resulting in a 2.16 megapixel detector, with a 16.5 cm × 16.5 cm active area and ∼80% coverage. The high dynamic range is achieved with three distinct gain settings (low, medium, high) as well as two auto-ranging modes (high-to-low and medium-to-low). Here the three fixed gain modes are evaluated. The resulting dynamic range (from single photon counting to 10000 photons pixel −1 pulse −1 at 8 keV) makes it suitable for a large number of different XFEL experiments. The ePix10k replaces the large CSPAD in operation since 2011. The dimensions of the two detectors are similar, making the upgrade from CSPAD to ePix10k straightforward for most setups, with the ePix10k improving on experimental performance. The SLAC-developed ePix cameras all utilize a similar platform, are tailored to target different experimental conditions and are designed to provide an upgrade path for future high-repetition-rate XFELs. Here the first measurements on this new ePix10k detector are presented and the performance under typical XFEL conditions evaluated during an LCLS X-ray diffuse scattering experiment measuring the 9.5 keV X-ray photons scattered from a thin liquid jet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-scale temperature-based strategy to map hydrologic exchange flows in highly dynamic systems

Mapping and quantifying hydrologic exchange flows (HEFs) is critical to environmental monitoring and remediation at contaminated sites; however, these objectives are challenging in highly dynamic systems, e.g., along dam-regulated rivers, where HEFs vary rapidly. Direct seepage measurements are labor-intensive and difficult to automate, whereas indirect (e.g., thermal) and remote sensing methods have potential to allow continuous monitoring with limited field effort. We present a preliminary assessment of a multi-scale temperature-based strategy for monitoring HEFs along the Hanford Reach of the Columbia River, in eastern WA, United States. Five thermal methods were assessed. First, a vertical temperature profile (VTP) was installed into the streambed. The VTP data were analyzed using a data assimilation algorithm designed for automated real-time estimation in dynamic systems. Second, a thermal infrared (TIR) camera was used in roving surveys to identify seeps. Third, a TIR camera was stationed at the VTP site to collect images at 1-h intervals. Together, the two TIR datasets provided a basis to assess the potential for drone-based TIR. Fourth, temperature was measured at the sediment/water interface to assess fiber-optic distributed temperature sensing. Fifth, imagery from the ECOSTRESS satellite mission was acquired to assess the potential of spaceborne thermal monitoring. Based on our preliminary assessment, VTP, TIR, and bed temperature measurements provide complementary spatial coverage, temporal sampling, and resolution; these methods have potential for long-term, automated monitoring of HEFs. The publicly available spaceborne imagery, however, proved inadequate because of insufficient spatial resolution and data gaps resulting from cloud cover and revisit frequency.

54 ENVIRONMENTAL SCIENCES↗

A plano–convex thick-lens velocity map imaging apparatus for direct, high resolution 3D momentum measurements of photoelectrons with ion time-of-flight coincidence

Since their inception, velocity map imaging (VMI) techniques have received continued interest in their expansion from 2D to 3D momentum measurements through either reconstructive or direct methods. Recently, much work has been devoted to the latter of these by relating electron time-of-flight (TOF) to the third momentum component. The challenge is having a timing resolution sufficient to resolve the structure in the narrow (<10 ns) electron TOF spread. Here, we build upon the work in VMI lens design and 3D VMI measurement by using a plano–convex thick-lens (PCTL) VMI in conjunction with an event-driven camera (TPX3CAM) providing TOF information for high resolution 3D electron momentum measurements. We perform simulations to show that, with the addition of a mesh electrode to the thick-lens geometry, the resulting plano–convex electrostatic field extends the detectable electron cutoff energy range while retaining the high resolution. This design also extends the electron TOF range, allowing for a better momentum resolution along this axis. We experimentally demonstrate these capabilities by examining above-threshold ionization in xenon, where the apparatus is shown to collect electrons of energy up to ∼7 eV with a TOF spread of ∼30 ns, both of which are improved compared to a previous work by factors of ∼1.4 and ∼3.75, respectively. Finally, the PCTL-VMI is equipped with a coincident ion TOF spectrometer, which is shown to effectively extract unique 3D momentum distributions for different ionic species in a gas mixture. These techniques have the potential to lend themselves to more advanced measurements involving systems where the electron momentum distributions possess non-trivial symmetries.

Instruments & Instrumentation↗

Double Image Polarimeter—Ultra Fast: Simultaneous Three-color (BVR) Polarimeter with Electron-multiplying Charge-coupled Devices

We describe a new instrument capable of high-precision (10{sup −5}) polarimetric observations simultaneously in three passbands (BVR). The instrument utilizes electron-multiplying charge-coupled device (EM CCD) cameras for high efficiency and fast image readout. The key features of the Double Image Polarimeter—Ultra Fast (DIPol-UF) are: (i) the optical design with high throughput and inherent stability; (ii) great versatility, which makes the instrument optimally suitable for observations of bright and faint targets; and (iii) a control system, which allows the use of the polarimeter remotely. Examples are given of the first results obtained from high signal-to-noise observations of bright nearby stars and of fainter sources such as X-ray binaries in their quiescent states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A low noise CMOS camera system for 2D resonant inelastic soft X-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) is a powerful spectroscopic technique to study quantum properties of materials in the bulk. A novel variant of RIXS, called 2D RIXS, enables concurrent measurement of the scattered X-ray spectrum for a wide range of input energies, improving on the typically low throughput of 1D RIXS. In the soft X-ray domain, 2D RIXS demands an X-ray camera system with small pixels, large area, high quantum efficiency and low noise to limit the false detection rate in long duration exposures. We designed and implemented a 7.5 Megapixel back-illuminated CMOS detector with 5 μm pixels and high quantum efficiency in the 200–1,000 eV X-ray energy range for the QERLIN 2D RIXS spectrometer at the Advanced Light Source. The QERLIN beamline and detector are currently in commissioning. The camera noise from in-situ 3 s long dark exposures is 7e - or less and the leakage current is 6.5 × 10 -3 e - /(pixel ∙ s). For individual 500 eV X-rays, the expected efficiency is greater than 75% and the false detection rate is ~1 × 10 -5 per pixel.

47 OTHER INSTRUMENTATION↗

Development of Short-Pulse Laser-Based Diagnostics for Pulsed Power-Driven Warm Dense Matter

This report summarizes a research project conducted at the Physics Department’s Zebra Pulsed Power Laboratory (ZPPL) at the University of Nevada Reno, aimed at developing short-pulse laser-based diagnostics to probe pulsed-power-driven warm dense matter. ZPPL combines a MegaAmpere (MA) pulsed power generator, Zebra, and a relativistic intensity, short-pulse laser, Leopard, offering a unique university-scale platform for high energy density physics, laboratory astrophysics, and inertial fusion energy research. The project focused on establishing a hard X-ray radiographic capability using high-intensity, short-pulse laser-generated X-rays to probe warm dense matter created by the Zebra current. Initial experiments produced X-ray radiographs of a static (cold) aluminum wire using silver and gold foil and wire targets, but intense background radiation from Zebra shots overwhelmed the laser-produced X-rays. To mitigate this, a radiationhardened detector housing was designed and implemented. Additional diagnostic, including a filter stack bremsstrahlung spectrometer and an X-ray pinhole camera, were developed to characterize laser-produced hard X-ray spectra and locate hard X-ray sources in the vacuum chamber. These revealed that strong hard X-rays (> 20 keV) originated near the anode cap, bombarded by energetic electrons. Due to laser unavailability during some experiments, detector performance was successfully tested using hard X-ray sources from the Zebra current, demonstrating their readiness for coupled experiments. The project supported one Ph.D. student (Dr. Lei Chen), who conducted experimental and numerical research, and provided training opportunities and data for three undergraduate senior theses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Billion-pixel x-ray camera (BiPC-X)

The continuing improvement in quantum efficiency (above 90% for single visible photons), reduction in noise (below 1 electron per pixel), and shrink in pixel pitch (less than 1 μm) enable billion-pixel x-ray cameras (BiPC-X) based on commercial complementary metal–oxide–semiconductor (CMOS) imaging sensors. We describe BiPC-X designs and prototype construction based on flexible tiling of commercial CMOS imaging sensors with millions of pixels. Device models are given for direct detection of low energy x rays (<10 keV) and indirect detection of higher energies using scintillators. Modified Birks’s law is proposed for light yield non-proportionality in scintillators as a function of x-ray energy. Single x-ray sensitivity and spatial resolution have been validated experimentally using a laboratory x-ray source and the Argonne Advanced Photon Source. Possible applications include wide field-of-view or large x-ray aperture measurements in high-temperature plasmas, the state-of-the-art synchrotron, x-ray free electron laser, and pulsed power facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of the Crab Nebula with the 9.7 m prototype Schwarzschild-Couder telescope

The Schwarzschild-Couder Telescope (SCT) is a telescope concept proposed for the Cherenkov Telescope Array. It employs a dual-mirror optical design to remove comatic aberrations over an 8° field of view, and a high-density silicon photomultiplier camera (with a pixel resolution of 4 arcmin) to record Cherenkov emission from cosmic ray and gamma-ray initiated particle cascades in the atmosphere. Additionally, the prototype SCT (pSCT), comprising a 9.7 m diameter primary mirror and a partially instrumented camera with 1536 pixels, has been constructed at the Fred Lawrence Whipple Observatory. The telescope was inaugurated in January 2019, with commissioning continuing throughout 2019. We describe the first campaign of observations with the pSCT, conducted in January and February of 2020, and demonstrate the detection of gamma-ray emission from the Crab Nebula with a statistical significance of 8.6σ.

79 ASTRONOMY AND ASTROPHYSICS↗

FiberFlex: Real-time FPGA-based Intelligent and Distributed Fiber Sensor System for Pedestrian Recognition

In recent years, security monitoring of public places and critical infrastructure has heavily relied on the widespread use of cameras, raising concerns about personal privacy violations. To balance the need for effective security monitoring with the protection of personal privacy, we explore the potential of optical fiber sensors for this application. This article proposes FiberFlex, an intelligent and distributed fiber sensor system. Ultizing Field Programmable Gate Arrays (FPGA) high-level synthesis (HLS) acceleration, FiberFlex offers real-time pedestrian detection by co-designing the entire pipeline of optical signal acquisition, processing, and recognition networks based on the principles of optical fiber sensing. As a promising alternative to traditional camera-based monitoring systems, FiberFlex achieves pedestrian detection by analyzing the vibration patterns caused by pedestrian footsteps, enabling security monitoring while preserving individual privacy. FiberFlex comprises three modules: First , fiber-optic sensing system: A fiber-optic distributed acoustic sensing (DAS) system is built and used to measure the ground vibration waves generated by people walking. Second , algorithms: We first collect the training data by measuring the ground vibration waves, label the data, and use the data to train the neural network models to perform pedestrian recognition. Third , hardware accelerators: We use HLS tools to design hardware modules on FPGA for data collection and pre-processing and integrate them with the downstream neural network accelerators to perform in-line real-time pedestrian detection. The final detection results are sent back from FPGA to the host CPU. We implement our system FiberFlex with the in-house built DAS system and AMD/Xilinx Kintex7 FPGA KC705 board and verify the whole system using the real-world collected data. We conduct recognition tests on five test subjects of varying ages, heights, and weights in a fixed sensing area. Each subject experienced 20 real-time recognition tests using their daily walking habits, and the subjects were given adequate rest between tests. After 100 tests on five test subjects, the overall real-time recognition accuracy exceeded \(88.0\%\) . The whole system uses 55 W of power, 33 W in the optical DAS system and 22 W in the FPGA. Relying on its end-to-end interdisciplinary design, FiberFlex seamlessly combines fiber-optic sensors with FPGA accelerators to enable low-power real-time security monitoring without compromising privacy, making it a valuable addition to the existing security monitoring network. According to FiberFlex, more valuable research can be conducted in the future, such as fall monitoring for the elderly, migration of identification networks between different application scenarios, and improvement of anti-interference performance in more complex environments. In future perception networks, where the “eyes” are not feasible, let’s use fiber optic touch instead.

Distributed↗

Towards Three-Dimensional Neutron Imaging with Light-field Technology

A broad range of applications in nuclear safeguards and security can benefit from compact, fast neutron imagers with large angular acceptance. However, accurate 3D multi-vertex reconstruction in a monolithic detector remains a significant barrier to realization. Current approaches, such as the centroiding approach and the use of shadow masks, have not yet resulted in a successful demonstration in a light-starved environment. This project explored the use of cutting-edge technology—a light field camera—which inherently preserves both the spatial and directional information of incident light. Such technology can, in principle, resolve multi-vertex events and offer accurate position reconstruction in 3D with relatively simple readout electronics. Since the project's inception in May 2023, we have built an experimental setup to calibrate and characterize a commercial light-field camera (Lytro Illum). We assessed its 3D event reconstruction capability in a relatively low-light intensity environment by analyzing the cross-correlation of a series of 2D images of a characterized tunable light source taken at various distances. A sub-cm resolution, lower than typical neutron interaction separations in a compact scintillator volume, was observed with the LED light source, suggesting the promising capability of its nominal optics design to provide the adequate resolution required for a compact monolithic neutron directional detector. However, using a light-field-based readout for a neutron camera requires incorporating an ultra-low-noise light sensor, which is beyond the scope of this project. We also initiated the development of a 3D light-field-based reconstruction algorithm tailored to sparse scenes, as expected from particle interactions in a scintillator medium. Additionally, we demonstrated the capability of the algorithm to replicate the ground truth. Finally, we began the development of a neutron directional detector simulation to determine the performance criteria for light-field-based reconstruction that allows for good neutron directional reconstruction. This Feasibility Study has led to a successful follow-up project under the DNN R&D innovation portfolio starting May 2024.

42 ENGINEERING↗

Characterization of MKIDs for CMB Observation at 220 GHz With the South Pole Telescope

We present an updated design of the 220 GHz microwave kinetic inductance detector (MKID) pixel for SPT-3G+, the next-generation camera for the South Pole Telescope. We show results of the dark testing of a 63-pixel array with mean inductor quality factor $Q_{i} = 4.8 \times 10^{5}$, aluminum inductor transition temperature $T_{c} = 1.19$K, and kinetic inductance fraction $\alpha _{k} = 0.32$. We optically characterize both the microstrip-coupled and CPW-coupled resonators, and find both have a spectral response close to prediction with an optical efficiency of $\eta \sim 70\%$. However, we find slightly lower optical response on the lower edge of the band than predicted, with neighboring dark detectors showing more response in this region, though at level consistent with less than 5% frequency shift relative to the optical detectors. The detectors show polarized response consistent with expectations, with a cross-polar response of $\sim 10\%$for both detector orientations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The One-hundred-deg 2 DECam Imaging in Narrowbands (ODIN): Survey Design and Science Goals

We describe the survey design and science goals for One-hundred-deg 2 DECam Imaging in Narrowbands (ODIN), a NOIRLab survey using the Dark Energy Camera (DECam) to obtain deep (AB ~ 25.7) narrowband images over an unprecedented area of sky. The three custom-built narrowband filters, N419, N501, and N673, have central wavelengths of 419, 501, and 673 nm and respective FWHM of 7.5, 7.6, and 10.0 nm, corresponding to Lyα at z = 2.4, 3.1, and 4.5 and cosmic times of 2.8, 2.1, and 1.4 Gyr, respectively. When combined with even deeper, public broadband data from the Hyper Suprime-Cam, DECam, and in the future, the Legacy Survey of Space and Time, the ODIN narrowband images will enable the selection of over 100,000 Lyα-emitting (LAE) galaxies at these epochs. ODIN-selected LAEs will identify protoclusters as galaxy overdensities, and the deep narrowband images enable detection of highly extended Lyα blobs (LABs). Primary science goals include measuring the clustering strength and dark matter halo connection of LAEs, LABs, and protoclusters, and their respective relationship to filaments in the cosmic web. The three epochs allow for the redshift evolution of these properties to be determined during the period known as Cosmic Noon, where star formation was at its peak. The narrowband filter wavelengths are designed to enable interloper rejection and further scientific studies by revealing [O II] and [O III] at z = 0.34, Lyα and He II 1640 at z = 3.1, and Lyman continuum plus Lyα at z = 4.5. Ancillary science includes similar studies of the lower-redshift emission-line galaxy samples and investigations of nearby starforming galaxies resolved into numerous [O III] and [S II] emitting regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Time‐Lapse Image Classification Using a Diffractive Neural Network

Diffractive deep neural networks (D 2 NNs), comprised of spatially engineered passive surfaces, collectively process optical input information at the speed of light propagation through a thin diffractive volume, without any external computing power. Diffractive networks were demonstrated to achieve all‐optical object classification and perform universal linear transformations. Herein, a “time‐lapse” image classification scheme using a diffractive network is demonstrated for the first time, significantly advancing its classification accuracy and generalization performance on complex input objects by using the lateral movements of the input objects and/or the diffractive network, relative to each other. In a different context, such relative movements of the objects and/or the camera are routinely being used for image super‐resolution applications; inspired by their success, a time‐lapse diffractive network is designed to benefit from the complementary information content created by controlled or random lateral shifts. The design space and performance limits of time‐lapse diffractive networks are numerically explored, revealing a blind testing accuracy of 62.03% on the optical classification of objects from the CIFAR‐10 dataset. This constitutes the highest inference accuracy achieved so far using a single diffractive network on the CIFAR‐10 dataset. Time‐lapse diffractive networks will be broadly useful for the spatiotemporal analysis of input signals using all‐optical processors.

36 MATERIALS SCIENCE↗

Novel Technology of Non-Contact Real-Time Radiation Damage Sensor for High Power Targets

High-power proton beams planned for forthcoming long-baseline neutrino experiments will subject solid targets to unprecedented radiation damage, threatening reliability and increasing costs. To address this challenge, we are building a real-time, non-contact sensor that tracks damage by measuring broadband laser reflectivity changes from the target surface. A low-power super-continuum Class 3B laser illuminates the sample inside a vacuum test chamber while a high-resolution fiber-coupled spectrometer captures S- and P-polarized light; spectral shifts reveal defect-driven variations in optical constants. My internship goal is to design, build, and commission this prototype by implementing a laser-safety interlock and light shield, integrating remote-operation cameras, and fabricating modular 3-D-printed mounts that enable tool-free swaps without disturbing alignment. The laser, spectrometer, and vacuum chamber have been delivered; interlock hardware, cameras, and mounts are in final assembly, and leak testing of the chamber is underway. Upcoming work will focus on initial calibration of the sensor and executing first beam-irradiation studies.

Pumarino, Rafael↗