Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Comparison and calibration of dose delivered by 137 Cs and x-ray irradiators in mice

Objective. The Office of Radiological Security, U.S. Department of Energy's National Nuclear Security Administration, is implementing a radiological risk reduction program which seeks to minimize or eliminate the use of high activity radiological sources, including 137 Cs, by replacing them with non-radioisotopic technologies, such as x-ray irradiators. The main goal of this paper is to evaluate the equivalence of the dose delivered by gamma- and x-ray irradiators in mice using experimental measurements and Monte Carlo simulations. We also propose a novel biophantom as an in situ dose calibration method. Approach. We irradiated mouse carcasses and 3D-printed mouse biophantoms in a 137 Cs irradiator (Mark I-68) and an x-ray irradiator (X-Rad320) at three voltages (160 kVp, 225 kVp and 320 kVp) and measured the delivered radiation dose. A Geant4-based Monte Carlo model was developed and validated to provide a comprehensive picture of gamma- and x-ray irradiation in mice. Main Results. Our Monte Carlo model predicts a uniform dose delivered in soft-tissue for all the explored irradiation programs and in agreement with the absolute dose measurements. Our Monte Carlo model shows an energy-dependent difference between dose in bone and in soft tissue that decreases as photon energy increases. Dose rate depends on irradiator and photon energy. We observed a deviation of the measured dose from the target value of up to –9% for the Mark I-68, and up to 35% for the X-Rad320. The dose measured in the 3D-printed phantoms are equivalent to that in the carcasses within 6% uncertainty. Significance. Our results suggest that 320 kVp irradiation is a good candidate to substitute 137 Cs irradiation barring a few caveats. There is a significant difference between measured and targeted doses for x-ray irradiation that suggests a strong need for in situ calibration, which can be achieved with 3D-printed mouse biophantoms. A dose correction is necessary for bone doses, which can be provided by a Monte Carlo calculation. Lastly, the biological implications of the differences in dose rates and dose per photon for the different irradiation methods should be carefully assessed for each small-animal irradiation experiment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibration verification for stochastic agent-based disease spread models

Accurate disease spread modeling is crucial for identifying the severity of outbreaks and planning effective mitigation efforts. To be reliable when applied to new outbreaks, model calibration techniques must be robust. However, current methods frequently forgo calibration verification (a stand-alone process evaluating the calibration procedure) and instead use overall model validation (a process comparing calibrated model results to data) to check calibration processes, which may conceal errors in calibration. In this work, we develop a stochastic agent-based disease spread model to act as a testing environment as we test two calibration methods using simulation-based calibration, which is a synthetic data calibration verification method. The first calibration method is a Bayesian inference approach using an empirically-constructed likelihood and Markov chain Monte Carlo (MCMC) sampling, while the second method is a likelihood-free approach using approximate Bayesian computation (ABC). Simulation-based calibration suggests that there are challenges with the empirical likelihood calculation used in the first calibration method in this context. These issues are alleviated in the ABC approach. Despite these challenges, we note that the first calibration method performs well in a synthetic data model validation test similar to those common in disease spread modeling literature. We conclude that stand-alone calibration verification using synthetic data may benefit epidemiological researchers in identifying model calibration challenges that may be difficult to identify with other commonly used model validation techniques.

60 APPLIED LIFE SCIENCES↗

Toward Improved Regional Hydrological Model Performance Using State-Of-The-Science Data-Informed Soil Parameters

Accurate soil moisture and streamflow data are an aspirational need of many hydrologically relevant fields. Model simulated soil moisture and streamflow hold promise but models require validation prior to application. Calibration methods are commonly used to improve model fidelity but misrepresentation of the true dynamics remains a challenge. In this study, we leverage soil parameter estimates from the Soil Survey Geographic (SSURGO) database and the probability mapping of SSURGO (POLARIS) to improve the representation of hydrologic processes in the Weather Research and Forecasting Hydrological modeling system (WRF-Hydro) over a central California domain. Our results show WRF-Hydro soil moisture exhibits increased correlation coefficients ( r ), reduced biases, and increased Kling-Gupta Efficiencies (KGEs) across seven in situ soil moisture observing stations after updating the model's soil parameters according to POLARIS. Compared to four well-established soil moisture data sets including Soil Moisture Active Passive data and three Phase 2 North American Land Data Assimilation System land surface models, our POLARIS-adjusted WRF-Hydro simulations produce the highest mean KGE (0.69) across the seven stations. More importantly, WRF-Hydro streamflow fidelity also increases, especially in the case where the model domain is set up with SSURGO-informed total soil thickness. The magnitude and timing of peak flow events are better captured, r increases across nine United States Geological Survey stream gages, and the mean KGE across seven of the nine gages increases from 0.12 to 0.66. Our pre-calibration parameter estimate approach, which is transferable to other spatially distributed hydrological models, can substantially improve a model's performance, helping reduce calibration efforts and computational costs.

54 ENVIRONMENTAL SCIENCES↗

Simulation, Challenge Testing and Validation of Solutions for Residential and Commercial Occupancy Sensing/Counting and CO2 Sensing (Final Report)

Carbon dioxide sensors used for monitoring and control applications in buildings are known to be sensitive to long term drift and can be affected by variations in temperature, humidity, other gas interferents, pressure and other factors that cannot be corrected through the typical auto-calibration methods often embedded in the sensor electronics. This investigation was part of the Category D defined in the ARPA-E Saving Energy Nationwide in Structures With Occupancy Recognition (SENSOR) Financial Assistance Funding Opportunity Announcement No. DE-FOA-0001737, FFDA No. 81.135, January 18, 2017. The FOA defined target criteria for the evaluation of the Category C commercial CO2 sensors selected for review and development through the ARPA-E SENSOR program and charged the Iowa State Category D team with developing an evaluation methodology for Category C sensors in accordance with these criteria. As part of the work, the Iowa State team chose to engage the standards community in the development of the evaluation methodology. Standard development work in the D22.05 Indoor Air and D22.03 Ambient Atmospheres and Source Emissions subcommittees of ASTM International Committee D22 on Air Quality on the evaluation of low cost sensors and provision of guidance for using indoor carbon dioxide concentrations to evaluate indoor air quality and ventilation is of particular relevance to the Category D efforts. To date, three draft standards with specific input by the Iowa State Category D team have passed the subcommittee balloting stage and are being balloted in December 2022 and January 2023 in the main D22 committee. In addition to the aforementioned standards to which the PI was a contributing author, intellectual property developed in this project pertaining to “An Automated System for Evaluation of the Long Term Performance of Carbon Dioxide Sensors” and “An Automated Ground Truth System for Real-Time Reliability Assessment, Capture of Control Decisions and Energy Savings Measurements for Occupancy Recognition Systems and Other Applications” are the other major deliverables of the project. These standards and the developed intellectual property are expected to benefit the public in a number of ways stemming from their provision of means to benchmark the performance of carbon dioxide and other sensor systems. In particular, there is high interest in techniques to demonstrate the performance of low-cost carbon dioxide sensors which can be used for typical HVAC applications (e.g., demand controlled ventilation, outdoor and indoor air monitoring, estimation of occupancy, etc.).

42 ENGINEERING↗

Lightning radiometry in visible and infrared bands

Calibrated measurements of lightning optical emissions are critical for both quantifying the impacts of lightning in our atmosphere and devising detection instruments with sufficient dynamic range capable of yielding close to 100% detection efficiency. However, to date, there is only a limited number of investigations that have attempted to take such calibrated measurements. Here, in this work, we report the power radiated by lightning in both visible and infrared bands, assuming isotropic emission, and accounting for atmospheric absorption. More precisely, we report peak radiated power and total radiated energy in the combined visible plus near-infrared range (VNIR, 0.34–1.1 μm), around the H α line (652–667 nm), and for the 2–2.5 μm infrared band. The estimated peak power and total energy radiated by negative cloud-to-ground return strokes in the VNIR range is 130 MW and 20 kJ, respectively. Additionally, we detected peak radiated powers of 12 and 0.19 MW in the H α and infrared bands, respectively. We cross-reference the optical data set with peak current reported by a lightning detection network. The resulting trend is that optical power emitted around the H α line scales with peak return stroke current according to a power law with exponent equal to 1.25. This trend, which should be approximately true across the entire visible spectrum, can be attributed to the plasma negative differential resistance of the lightning return stroke channel. We conclude by discussing the challenges in performing calibrated measurements of lightning optical power in different bands and comparing the results with previously-collected data with different experimental setups, observation conditions, and calibration methods.

54 ENVIRONMENTAL SCIENCES↗

A predictive discrete-continuum multiscale model of plasticity with quantified uncertainty

Multiscale models of materials, consisting of upscaling discrete simulations to continuum models, are unique in their capability to simulate complex materials behavior. The fundamental limitation in multiscale models is the presence of uncertainty in the computational predictions delivered by them. In this work, a sequential multiscale model has been developed, incorporating discrete dislocation dynamics (DDD) simulations and a strain gradient plasticity (SGP) model to predict the size effect in plastic deformations of metallic micro-pillars. The DDD simulations include uniaxial compression of micro-pillars with different sizes and over a wide range of initial dislocation densities and spatial distributions of dislocations. An SGP model is employed at the continuum level that accounts for the size-dependency of flow stress and hardening rate. Sequences of uncertainty analyses have been performed to assess the predictive capability of the multiscale model. The variance-based global sensitivity analysis determines the effect of parameter uncertainty on the SGP model prediction. The multiscale model is then constructed by calibrating the continuum model using the data furnished by the DDD simulations. A Bayesian calibration method is implemented to quantify the uncertainty due to microstructural randomness in discrete dislocation simulations (density and spatial distribution of dislocations) on the macroscopic continuum model prediction (size effect in plastic deformation). Here, the outcomes of this study indicate that the discrete-continuum multiscale model can accurately simulate the plastic deformation of micro-pillars, despite the significant uncertainty in the DDD results. Additionally, depending on the macroscopic features represented by the DDD simulations, the SGP model can reliably predict the size effect in plasticity responses of the micropillars with below 10% of error.

36 MATERIALS SCIENCE↗

The CLAS12 drift chamber system

The CEBAF Large Acceptance Spectrometer at 12~GeV (CLAS12) is located in Hall~B, one of the experimental halls at Jefferson Lab. The forward part of CLAS12 is built around a superconducting toroidal magnet. The six coils of the toroid divide the detector azimuthally into six sectors. Each sector contains three multi-layer drift chambers for reconstructing the trajectories of charged particles originating from a fixed target. Each of the 18 planar chambers has two ``superlayers'' of six layers each, with the wires in the two adjacent superlayers oriented at ± 6° stereo angles. Each layer has 112 hexagonal cells spanning a range from about 5° to 40° in polar angle. The six-layer structure provides redundancy in track segment finding and good tracking efficiency even in the presence of some individual wire inefficiency. The design, construction, operation, and calibration methods are described, and estimates of the efficiency and resolution are presented from in-beam measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Representing Global Soil Erosion and Sediment Flux in Earth System Models

Abstract Soil erosion produces enormous amounts of sediment, carbon, and nutrient fluxes from land to rivers, thus playing crucial roles in global biogeochemical cycles and food security. To predict soil erosion in the context of climate and land use changes, we explicitly parameterize cropland management actions (i.e., irrigation, conserved agriculture, and crop residue management) and geological factors (i.e., lithology and glacier) in the Energy Exascale Earth System Model (E3SM) soil erosion module. The erosion model is calibrated using a global‐scale regionalized parameter calibration method. The spatial variabilities of the modeled and the Revised Universal Soil Loss Equation (RUSLE) based benchmark soil erosion are consistent across vegetation, climate and soil properties. Compared with independent data, our model shows a bias reduction in 59% of the observations relative to the RUSLE‐based soil erosion, with 53% of the bias reduction exceeding 50%. This improvement is mainly due to a better representation of the topographic effect on soil erosion. Our results indicate that conserved agriculture practices have effectively reduced soil erosion in cropland by over 25% in the United States and Argentina. In contrast, irrigation has increased soil erosion in many Asian countries. For upland sediment flux, our model is consistent with the WBMsed benchmark data in inter‐basin variability but could be more skillful in simulating intra‐basin variability because it couples soil erosion and sediment flux explicitly. The developed model provides useful skills for more realistic predictions of soil erosion and river sediment dynamics under environmental changes.

58 GEOSCIENCES↗

Ground far-red sun-induced chlorophyll fluorescence and vegetation indices in the US Midwestern agroecosystems

Abstract Sun-induced chlorophyll fluorescence (SIF) provides an opportunity to study terrestrial ecosystem photosynthesis dynamics. However, the current coarse spatiotemporal satellite SIF products are challenging for mechanistic interpretations of SIF signals. Long-term ground SIF and vegetation indices (VIs) are important for satellite SIF validation and mechanistic understanding of the relationship between SIF and photosynthesis when combined with leaf- and canopy-level auxiliary measurements. In this study, we present and analyze a total of 15 site-years of ground far-red SIF (SIF at 760 nm, SIF 760 ) and VIs datasets from soybean, corn, and miscanthus grown in the U.S. Corn Belt from 2016 to 2021. We introduce a comprehensive data processing protocol, including different retrieval methods, calibration coefficient adjustment, and nadir SIF footprint upscaling to match the eddy covariance footprint. This long-term ground far-red SIF and VIs dataset provides important and first-hand data for far-red SIF interpretation and understanding the mechanistic relationship between far-red SIF and canopy photosynthesis across various crop species and environmental conditions.

59 BASIC BIOLOGICAL SCIENCES↗

J-PLUS: Systematic impact of metallicity on photometric calibration with the stellar locus

Here, we present the photometric calibration of the twelve optical passbands for the Javalambre Photometric Local Universe Survey (J-PLUS) second data release (DR2), comprising 1088 pointings of two square degrees, and study the systematic impact of metallicity on the stellar locus technique. The [Fe/H] metallicity from the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) for 146 184 high-quality calibration stars, defined with signal-to-noise ratio larger than ten in J-PLUS passbands and larger than three in Gaia parallax, was used to compute the metallicity-dependent stellar locus (ZSL). The initial homogenization of J-PLUS photometry, performed with a unique stellar locus, was refined by including the metallicity effect in colors via the ZSL. The variation of the average metallicity along the Milky Way produces a systematic offset in J-PLUS calibration. This effect is well above 1% for the bluer passbands and amounts 0.07, 0.07, 0.05, 0.03, and 0.02 mag in u, J0378, J0395, J0410, and J0430, respectively. We modeled this effect with the Milky Way location of the J-PLUS pointing, also providing an updated calibration for those observations without LAMOST information. The estimated accuracy in the calibration after including the metallicity effect is at 1% for the bluer J-PLUS passbands and below for the rest. Photometric calibration with the stellar locus technique is prone to significant systematic bias in the Milky Way for passbands bluer than λ = 4500 Å. The calibration method for J-PLUS DR2 reaches 1–2% precision and 1% accuracy for 12 optical filters within an area of 2176 square degrees.

79 ASTRONOMY AND ASTROPHYSICS↗

Alternatives to NIST Cf-252 Iirradiations for Transfer Calibration of S-32 Neutron Monitors

Gas-flow proportional counting systems are used by the Radiation Metrology Laboratory (RML) at Sandia National Laboratories for reactor fluence monitoring with the 32 S(n,p) 32 P reaction. Calibration of these systems has traditionally been accomplished by fluence-transfer irradiations at the NIST 252 Cf facility. Such calibrations have become increasingly difficult as the NIST 252 Cf source decayed to unusable levels. To minimize the risk to the testing programs from an inability to properly calibrate these systems, the RML has developed two alternative calibration techniques: 1) development and implementation of certified 32 P sources for activity calibrations and subsequent calculation of neutron fluence, and 2) direct counting of non-certified reactor-irradiated sulfur pellets by liquid scintillation counting to determine 32 P activity for the subsequent calibration of gas-flow proportional counters. Preliminary comparisons show that the several calibration methods are capable of overall uncertainties within about 5 percent.

Vehar, David W.↗

Phonon-mediated quantum efficiency measurement in semiconductors

Accurate quantum efficiency measurement not only provides crucial information for the photovoltaic cell industry but also supports experiments aimed at directly detecting dark matter and elastic neutrino interactions. The dark matter direct searches paradigm has recently expanded to include particles with masses below 1,MeV/c2, where the expected signal in an electron–recoil interaction is approximately in the eV range, just above the energy gap for silicon and germanium. A robust calibration method for ionization signals in this lower energy region is essential. This paper presents a method for measuring quantum efficiency and yield (q/E) in semiconductors using phonon-mediated calorimetry. The Neganov–Trofimov–Luke phonon amplification method in low-temperature semiconductor crystals has been employed to indirectly measure ionization down to single-electron accuracy. Specifically, at zero bias, the phonon readout directly quantifies the total energy deposited within the detector, independent of the ionization yield. This eliminates a significant source of systematic uncertainty in quantum efficiency estimates associated with total energy uncertainty. The paper includes results from an updated ionization efficiency measurement in a germanium detector.

Physics↗

Spin echo small-angle neutron scattering using superconducting magnetic Wollaston prisms

Here, we show the implementation of superconducting magnetic Wollaston prisms for spin echo small-angle neutron scattering. Two calibration methods for the spin echo length are presented: one utilizing spin echo modulated small-angle neutron scattering and the other based on the neutron refraction by quartz wedge crystals. Our experimental results with polystyrene nano-particle colloids showcase the system’s efficacy in measuring both dilute and concentrated colloidal systems. Additionally, investigations into the pore diameter and pitch of a nano-porous alumina membrane demonstrate its capability in analyzing nano-porous materials. Furthermore, we discuss potential optimizations to further extend the accessible spin echo length.

47 OTHER INSTRUMENTATION↗

Broadband optical modulation and control at millikelvin temperatures

A universal experimental challenge in studying radiation effects on cryogenic devices is precisely and accurately characterizing the position-dependent device response near the energy detection threshold. Here, we have developed a compact cryogenic optical beam steering system that can be used to generate O (μs) pulses of small numbers of photons over the energy range of 1.3–3.4 eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including superconducting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric field dependence of nanoscale cathodoluminescence inside Cr doped β-Ga 2 O 3 interfaces

Chromium (Cr) is a common impurity in β-Ga 2 O 3 crystals, where its characteristic R1 and R2 luminescence lines are susceptible to both the host crystal field and externally applied fields. Here, in this work, we demonstrate that the Cr cathodoluminescence (CL) quenches toward the bulk of the crystal but enhances with applied reverse bias, reflecting the effect of free carrier depletion with increasing electric field. Furthermore, we illustrate that the R1/R2 CL intensity ratio, measured as the integrated area ratio of R1 to R2, can be used as a direct probe of the electric field in a Ni-β-Ga 2 O 3 : Cr Schottky diode. This optical calibration method provides a complementary approach to conventional C–V and I–V measurements for determining electric field strength in the depletion region of β-Ga 2 O 3 -based Schottky diodes and can be extended to other semiconductors and multilayer device structures.

36 MATERIALS SCIENCE↗

Coherent microwave scattering from resonance enhanced multi-photon ionization (Radar REMPI): A review

Coherent microwave scattering from laser-induced plasmas, including weakly ionized plasma, laser sparks, Multiphoton Ionization (MPI), and Resonance Enhanced Multi-Photon Ionizations (Radar REMPI) has achieved much successes in plasma, reactive and nonreactive flow diagnostics. Under illumination of microwaves (Radar), electrons inside the laser-induced plasma oscillate with the electric field of the microwave and re-radiate from the electrons forming coherent scattering. In the far-field approximation, the microwave scattering from the small volume plasma reflects the generation and evolution of unbounded electrons inside the plasma, when the microwave wavelength is much greater than the size of the plasma and the skin layer depth at the microwave frequency is larger than the size of the plasma. Laser excitation schemes, microwave detection methods, calibration of microwave scattering, and the novel applications of the technique have been significantly expanded and improved. Furthermore, this review paper summarizes physical principles, various REMPI excitation schemes for atomic and molecular species, and temperature measurements in plasma and reactive flows. Discussions on new research directions and applications are given at the end.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A long path-length optical property measurement device for highly transparent detector media

Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.

47 OTHER INSTRUMENTATION↗

The DEHVILS survey overview and initial data release: high-quality near-infrared Type Ia supernova light curves at low redshift

ABSTRACT While the sample of optical Type Ia supernova (SN Ia) light curves (LCs) usable for cosmological parameter measurements surpasses 2000, the sample of published, cosmologically viable near-infrared (NIR) SN Ia LCs, which have been shown to be good ‘standard candles,’ is still ≲ 200. Here, we present high-quality NIR LCs for 83 SNe Ia ranging from 0.002 < z < 0.09 as a part of the Dark Energy, H0, and peculiar Velocities using Infrared Light from Supernovae (DEHVILS) survey. Observations are taken using UKIRT’s WFCAM, where the median depth of the images is 20.7, 20.1, and 19.3 mag (Vega) for Y, J, and H-bands, respectively. The median number of epochs per SN Ia is 18 for all three bands (Y,J, and H) combined and 6 for each band individually. We fit 47 SN Ia LCs that pass strict quality cuts using three LC models, SALT3, snoopy, and B ayeSN and find scatter on the Hubble diagram to be comparable to or better than scatter from optical-only fits in the literature. Fitting NIR-only LCs, we obtain standard deviations ranging from 0.128 to 0.135 mag. Additionally, we present a refined calibration method for transforming 2MASS magnitudes to WFCAM magnitudes using HST CALSPEC stars that results in a 0.03 mag shift in the WFCAM Y-band magnitudes.

Astronomy & Astrophysics↗