Sources of error and methods to improve accuracy in interface state density analysis using quasi-static capacitance–voltage measurements in wide bandgap semiconductors

Characterizing interface trap states in commercial wide bandgap devices using frequency-based measurements requires unconventionally high probing frequencies to account for both fast and slow traps associated with wide bandgap materials. The C - ψs technique has been suggested as a viable quasi-static method for determining the interface trap state densities in wide bandgap systems, but the results are shown to be susceptible to errors in the analysis procedure. Here this work explores the primary sources of errors present in the C - ψs technique using an analytical model that describes the apparent response for wide bandgap MOS capacitor devices. Measurement noise is shown to greatly impact the linear fitting routine of the 1/C$^{*2}_s$ vs Ψ s plot to calibrate the additive constant in the surface potential/gate voltage relationship, and an inexact knowledge of the oxide capacitance is also shown to impede interface trap state analysis near the band edge. In addition, a slight nonlinearity that is typically present throughout the 1/C$^{*2}_s$ vs Ψ s plot hinders the accurate estimation of interface trap densities, which is demonstrated for a fabricated n-SiC MOS capacitor device. Methods are suggested to improve quasi-static analysis, including a novel method to determine an approximate integration constant without relying on a linear fitting routine.

42 ENGINEERING↗

Risk Ratio and Risk Difference Estimation in Case-cohort Studies

Background: In case-cohort studies with binary outcomes, ordinary logistic regression analyses have been widely used because of their computational simplicity. However, the resultant odds ratio estimates cannot be interpreted as relative risk measures unless the event rate is low. The risk ratio and risk difference are more favorable outcome measures that are directly interpreted as effect measures without the rare disease assumption. Methods: We provide pseudo-Poisson and pseudo-normal linear regression methods for estimating risk ratios and risk differences in analyses of case-cohort studies. These multivariate regression models are fitted by weighting the inverses of sampling probabilities. Also, the precisions of the risk ratio and risk difference estimators can be improved using auxiliary variable information, specifically by adapting the calibrated or estimated weights, which are readily measured on all samples from the whole cohort. Finally, we provide computational code in R (R Foundation for Statistical Computing, Vienna, Austria) that can easily perform these methods. Results: Through numerical analyses of artificially simulated data and the National Wilms Tumor Study data, accurate risk ratio and risk difference estimates were obtained using the pseudo-Poisson and pseudo-normal linear regression methods. Also, using the auxiliary variable information from the whole cohort, precisions of these estimators were markedly improved. Conclusion: The ordinary logistic regression analyses may provide uninterpretable effect measure estimates, and the risk ratio and risk difference estimation methods are effective alternative approaches for case-cohort studies. These methods are especially recommended under situations in which the event rate is not low.

60 APPLIED LIFE SCIENCES↗

An airborne study of microwave surface sensing and boundary layer heat and moisture fluxes for Project FIFE

This is the third semiannual status report describing the University of Wyoming participation in project FIFE, under NASA Grant NAG 5-913. The reader is referred to the first and second semiannual status reports for this grant for descriptions of University of Wyoming participation in the field operations of 1987. This report is concerned with continuing analysis of field data. Most of the instrument calibration effort has concentrated on interpretation and use of the high-rate water vapor measurements with the University of Wyoming Lyman-alpha device. In addition, fluxes of water vapor have been corrected for sensible heat flux, and all the high-rate (10 Hz for the Wyoming King Air) data have been filtered before the flux calculations. For each flight the Lyman-alpha data (10 Hz) are calibrated against the Cambridge dew-point hygrometer (1 Hz), by using data from the take-off sounding. The reasoning here is that the takeoff sounding (held to 500 fpm rate-of-climb specifically for the calibration) covers the widest range of humidity conditions of any sequence of the flight. For each takeoff sounding, then, the Lyman-alpha data, averaged to 1 Hz, are matched to the dewpoint data with a second-order least-squares fit. The resulting quadratic equation is then used in all subsequent analyses to convert the Lyman-alpha voltages to vapor desities for that specific flight. An alternative method is to use the range of fluctuation for the same two devices from horizontal passes to establish the calibration function. However, since the Lyman-alpha data are used only in the flux calculations, i.e., only the fluctuation and not the absolute values are used, this method is thought unnecessary.

Kelly, Robert D.↗

Strong Lensing Cosmology with Population-level Calibrated Neural Ratio Estimation

Strong gravitational lensing contains key information about cosmic acceleration. Modern and next-generation galaxy imaging surveys are expected to provide high-quality data on $\mathcal{O}(10^5)$ galaxy-galaxy lensing systems. The plethora and complexity of the data are likely to present computational challenges for parameter inference methods for fitting high-dimensional likelihoods, which are often analytically intractable. Neural Ratio Estimation (NRE) efficiently computes individual likelihood ratios that can be combined into population-level posteriors. We use simulations to study the capacity of NRE to jointly predict the dark energy equation-of-state parameter $w$ and the total matter density $Ω_{m}$ from lensing images and companion spectroscopic information. We also introduce a post hoc posterior coverage calibration procedure that mitigates the model overconfidence that is typically found in neural density estimation applications. Our experiments show that the errors on both parameters decrease with increasing inference population sizes. In particular, for 100 lenses in a standard $Λ$CDM Universe, our calibrated NRE model achieves median fractional uncertainty of $22.8\%$ in $w$ and $2.9\%$ in $Ω_{m}$. This proof of concept demonstrates a potentially scalable approach for efficient cosmological parameter inference with large populations of galaxy-scale lenses observed in future surveys.

Jarugula, Sreevani [Fermilab] (ORCID:0000000253867↗

Wind Tunnel Strain-Gage Balance Calibration Data Analysis Using a Weighted Least Squares Approach

A new approach is presented that uses a weighted least squares fit to analyze wind tunnel strain-gage balance calibration data. The weighted least squares fit is specifically designed to increase the influence of single-component loadings during the regression analysis. The weighted least squares fit also reduces the impact of calibration load schedule asymmetries on the predicted primary sensitivities of the balance gages. A weighting factor between zero and one is assigned to each calibration data point that depends on a simple count of its intentionally loaded load components or gages. The greater the number of a data point's intentionally loaded load components or gages is, the smaller its weighting factor becomes. The proposed approach is applicable to both the Iterative and Non-Iterative Methods that are used for the analysis of strain-gage balance calibration data in the aerospace testing community. The Iterative Method uses a reasonable estimate of the tare corrected load set as input for the determination of the weighting factors. The Non-Iterative Method, on the other hand, uses gage output differences relative to the natural zeros as input for the determination of the weighting factors. Machine calibration data of a six-component force balance is used to illustrate benefits of the proposed weighted least squares fit. In addition, a detailed derivation of the PRESS residuals associated with a weighted least squares fit is given in the appendices of the paper as this information could not be found in the literature. These PRESS residuals may be needed to evaluate the predictive capabilities of the final regression models that result from a weighted least squares fit of the balance calibration data.

calibration analysis↗

An IUE survey of activity in red giants and supergiants

Chromospheric and transition region line activity is examined in apparently single red giants and supergiants using the IUE archives. Low-resolution, large-aperture spectra (mostly short-wavelength) were used to search for variations of emission-line fluxes in time. A series of automatic processing procedures were implemented in order to uniformly calibrate a large number of spectra, fit continua to each of them, determine the fluxes of as many as 18 emission lines, and compare them at different epochs. A method is offered to compute the overall error in the integrated flux, a critical measure of activity, independent of the observing and processing details. This processing was applied to above 120 images of 26 stars taken over a period of 7 yr (1978-1984). Four stars showed UV emission-line flux variations. Alpha Aqr, Beta Peg, and Sigma Oph showed a single enhanced-emission event in all detectable emission lines. Gamma Aql exhibited an increase in the flux level of the O I (1641 A) line in mid-1981 with no comparable change in any other lines. These four stars lie in a region of the H-R diagram in which time-dependent circumstellar absorption lines appear.

Oznovich, I.↗

XCal: model-based approach to X-ray CT spectral calibration

Transmission X-ray computed tomography (CT) is widely used to quantitatively reconstruct 3D objects composed of multiple materials. However, accurate CT reconstruction requires the system to be calibrated to account for the effective X-ray spectrum. Unfortunately, measurement of the effective spectrum is ill-posed, and existing calibration methods require that the system be recalibrated when the system parameters are changed. In this paper, we propose XCal, a multi-energy model-based spectral calibration approach for X-ray CT. The XCal approach models the effective spectrum using a separable physics-based model of the CT system. The model parameters are then estimated by fitting calibration data with known objects at multiple energies. An important advantage of XCal is that it allows the user to change scanner settings, such as the source voltage or X-ray filters, without the need for recalibration. Evaluations on simulated and measured datasets demonstrate that XCal significantly improves the accuracy of the estimated spectrum as compared to existing calibration methods.

Li, Wenrui [Purdue Univ., West Lafayette, IN (Unit↗

Calibration of the light-flavour jet mistagging efficiency of the b -tagging algorithms with Z+jets events using 139 $\textrm{fb}^{-1}$ of ATLAS proton–proton collision data at $\sqrt{s} = 13$ TeV

The identification of b -jets, referred to as b -tagging, is an important part of many physics analyses in the ATLAS experiment at the Large Hadron Collider and an accurate calibration of its performance is essential for high-quality physics results. This publication describes the calibration of the light-flavour jet mistagging efficiency in a data sample of proton–proton collision events at $\sqrt{s} = 13$ TeV corresponding to an integrated luminosity of 139 fb -1 . The calibration is performed in a sample of Z bosons produced in association with jets. Due to the low mistagging efficiency for light-flavour jets, a method which uses modified versions of the b-tagging algorithms referred to as flip taggers is used in this work. A fit to the jet-flavour-sensitive secondary-vertex mass is performed to extract a scale factor from data, to correct the light-flavour jet mistagging efficiency in Monte Carlo simulations, while simultaneously correcting the b -jet efficiency. With this procedure, uncertainties coming from the modeling of jets from heavy-flavour hadrons are considerably lower than in previous calibrations of the mistagging scale factors, where they were dominant. The scale factors obtained in this calibration are consistent with unity within uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A combined experimental and computational analysis of failure mechanisms in open-hole cross-ply laminates under flexural loading

In this work, integrated experimental tests and computational modeling are proposed to investigate the failure mechanisms of open-hole cross-ply carbon fiber reinforced polymer (CFRP) laminated composites. In particular, we propose two effective methods, which include width-tapered double cantilever beam (WTDCB) and fixed-ratio mixed-mode end load split (FRMMELS) tests, to obtain the experimental data more reliably. We then calibrate the traction-separation laws of cohesive zone model (CZM) used among laminas of the composites by leveraging these two methods. The experimental results of fracture energy, i.e. G Ic and G Tc , obtained from WTDCB and FRMMELS tests are generally insensitive to the crack length thus requiring no effort to accurately measure the crack tip. Moreover, FRMMELS sample contains a fixed mixed-mode ratio of G IIc /G Tc depending on the width taper ratio. Examining comparisons between experimental results of FRMMELS tests and failure surface of B–K failure criterion predicted from a curve fitting, good agreement between the predictions and experimental data has been found, indicating that FRMMELS tests are an effective method to determine mixed-mode fracture criterion. In addition, a coupled experimental-computational modeling of WTDCB, edge notched flexure, and FRMMELS tests are adopted to calibrate and validate the interfacial strengths. Finally, failure mechanisms of open-hole cross-ply CFRP laminates under flexural loading have been studied systematically using experimental and multi-scale computational analyses based on the developed CZM model. The initiation and propagation of delamination, the failure of laminated layers as well as load-displacement curves predicted from computational analyses are in good agreement with what we have observed experimentally.

36 MATERIALS SCIENCE↗

The Use of Absolute-Value Terms in Regression Modeling of Multi-Piece Force Balances

Different aspects of the use of absolute-value terms in regression models of the electrical outputs of multi-piece force balance calibration data are discussed. First, characteristics of a variety of regression model term combinations with absolute-value terms are reviewed that are currently used in the aerospace testing community to fit the gage outputs of a balance. Then, a semi-empirical test is presented that quantifies bidirectional characteristics of the balance bridge outputs. Several diagnostic methods are discussed to assess the severity of near-linear dependencies between regressors of models with absolute-value terms. In particular, connections between the linear, absolute-value, quadratic, signed quadratic, and cubic terms are studied in greater detail. Data from an automated calibration of NASAs MK29B force balance are used to illustrate the most important observations and results. Rules of thumb that variance-inflation factors be less than 10 must be relaxed when using absolute-value terms to describe bidirectional balances.

calibration analysis↗

Mid-Latitude Temperatures at 87 km: Results From Multi-Instrument Fourier Analysis

Using a novel Fourier fitting method we combine two years of mid-latitude temperature measurements at 87 km from the High Resolution Doppler Imager, the Colorado State University lidar, and the Peach Mountain Interferometer. After accounting for calibration bias, significant local-time variations on the order of 10 K were observed. Stationary planetary waves with amplitudes up to 10 K were observed during winter, with weaker wave amplitudes occurring during other seasons. Because of calibration biases among these instruments, we could estimate the annual mean temperature to no better than 193.5 plus or minus 8.5 K.

FOURIER ANALYSIS↗

Calibration and Data Analysis of the MC-130 Air Balance

Design, calibration, calibration analysis, and intended use of the MC-130 air balance are discussed. The MC-130 balance is an 8.0 inch diameter force balance that has two separate internal air flow systems and one external bellows system. The manual calibration of the balance consisted of a total of 1854 data points with both unpressurized and pressurized air flowing through the balance. A subset of 1160 data points was chosen for the calibration data analysis. The regression analysis of the subset was performed using two fundamentally different analysis approaches. First, the data analysis was performed using a recently developed extension of the Iterative Method. This approach fits gage outputs as a function of both applied balance loads and bellows pressures while still allowing the application of the iteration scheme that is used with the Iterative Method. Then, for comparison, the axial force was also analyzed using the Non-Iterative Method. This alternate approach directly fits loads as a function of measured gage outputs and bellows pressures and does not require a load iteration. The regression models used by both the extended Iterative and Non-Iterative Method were constructed such that they met a set of widely accepted statistical quality requirements. These requirements lead to reliable regression models and prevent overfitting of data because they ensure that no hidden near-linear dependencies between regression model terms exist and that only statistically significant terms are included. Finally, a comparison of the axial force residuals was performed. Overall, axial force estimates obtained from both methods show excellent agreement as the differences of the standard deviation of the axial force residuals are on the order of 0.001 % of the axial force capacity.

Booth, Dennis↗

On-Orbit Calibration of Redundant Spacecraft Gyros by Optimal Reduction to Three Axes

The Aqua spacecraft will carry four single-axis gyros configured with three orthogonal axes and one skew axis. This redundancy presents a challenge for batch methods of on-orbit gyro calibration that use a spacecraft rotation model deterministically related to gyro data, in that sensor data can respond to at most three angular velocity components. When the number of gyros, N, is greater than 3, the 3xN matrix, G, that reduces the N gyro measurements to three body-frame angular-velocity components cannot be fully determined by such methods; there are many such matrices that produce essentially the same angular velocity history. In such a case, spacecraft operators require information about the Nx3 gyro linear response matrix, R, that relates gyro outputs to the body-frame angular velocities causing them. This matrix provides sufficient information to determine multiple reduced-dimension G-matrices for use in case of failure or degradation of one or more gyros, as well as to determine an optimal 3xN G for the fully-functional configuration. A viable proposal is to apply a 3xN pre-filter matrix, F, to the N gyro outputs before carrying out a conventional gyro calibration procedure. The angular-velocity history emerging from conventional calibration may then be used as input data, together with the same gyro data that generated it, to fit the alignment, scale-factor, and bias parameters of each gyro axis in turn. A difficulty of such a proposal is the arbitrariness in the choice of F. Due to gyro noise, different pre-filter matrices produce different calibrations. This paper presents a method of choosing F that is based on optimizing gyro consistency in the limit of infinite weight on gyro data, as compared to sensor data. The choice of F is independent of a priori alignment and is based on the gyro data alone. The method is applicable to any N of three or more, but reduces to conventional batch-estimation methodologies when N = 3. Results of computational comparison among calibration simulations using various choices of F will be presented for the Aqua gyro configuration with N = 4.

Radomski, M. S.↗

The gas-phase mass–metallicity relation of dwarf galaxies across large-scale environments using the CAVITY parent sample

Context. The gas-phase mass–metallicity relation (MZR) of galaxies shows a noticeable break in slope and an increased scatter at low stellar masses, suggesting that the physical processes governing chemical enrichment differ between dwarf and high-mass systems. Dwarf galaxies, in particular, are highly susceptible to both internal and environmental mechanisms due to their shallow potential wells. Aims. The primary aim of this work is to assess whether a single, universal MZR can describe dwarf galaxies across diverse large-scale environments, or whether systematic environmental variations emerge. To probe these, we examine the MZR and star formation rate (SFR) of dwarf galaxies with stellar masses in the range of 8.9 < log(M ★ /M ⊙ ) < 9.5. Methods. Using optical spectra from the Sloan Digital Sky Survey, we measured the fluxes of key emission lines via the pyPipe3D full spectral fitting pipeline. Aperture-corrected fluxes, along with multiple metallicity indicators and calibrations, were used to derive the MZR and the SFR for 353, 311, and 22 dwarf galaxies located in voids, filaments, and clusters, respectively. Results. We find a systematic variation in the MZR slope, steeper in voids (0.28 ± 0.03) and progressively flatter in clusters (0.17 ± 0.08), indicating a dependence of the MZR on the large-scale environment in this mass regime. When galaxies are separated by local density, no significant differences are observed between isolated and non-isolated dwarfs in voids. Isolated dwarf galaxies in filaments also exhibit properties similar to those of their counterparts in voids. However, non-isolated filament galaxies exhibit similar MZR slopes comparable to those of cluster dwarfs and flatter slopes than their counterparts in voids. Conclusions. We report both large- and local-scale environmental dependencies in the gas-phase metallicity and in the slope of the MZR for dwarf galaxies. Consistent with the general consensus on the pre-processing of galaxies in filaments, our results indicate that the influence of the local environment becomes increasingly significant within the filamentary regions of the cosmic web, affecting the chemical enrichment and star formation activity of low-mass systems. These findings further suggest that a portion of the scatter commonly observed in the MZR of dwarf galaxies arises from environmental effects.

Bidaran, Bahar [Dpto. de Física Teórica y del Cosm↗

New Capability at ORNL: High Precision Uranium Titration

Destructive analytical measurements establish a nuclear facility’s nuclear material inventory and inventory differences for Nuclear Material Accountancy and Control. A nuclear laboratory’s ability to perform accurate high-precision analytical measurements is key for tracking large inventories within a facility’s material balance areas and during production to track material movement through dynamic processes. For uranium, these measurements are made by using several established high-precision measurement protocols. These include isotope dilution mass spectrometry, gravimetry, and potentiometric titrations. Whatever measurement technique a nuclear lab chooses to use, reference materials (RMs) with certified attributes and accompanying uncertainties are used to calibrate measurement systems, and are the cornerstone for accurate results. In addition to calibration, RMs provide for metrological traceability, are used for method development and validation, and thus provide critical evaluations of the appropriateness and performance of analytical processes used. Evaluations may include validation that a method is fit-for-purpose, quantification of systematic and random biases, and the evaluation of long-term and short-term performance metrics. High-precision measurement techniques require that measured attributes be certified to a high degree of precision in the RMs used—ultimately, to a higher degree than that of the measurement technique itself. The US authority on the production of special nuclear material Certified Reference Materials is the NBL Program Office (NBLPO), formally known as New Brunswick Laboratory (NBL). The NBLPO is responsible for the sales and distribution of existing NBL certified reference materials (CRMs) and for the production of the next generation of nuclear RMs. To accomplish its mission, NBLPO is establishing key base capabilities within the DOE laboratory complex that formerly existed at the NBL laboratory. The Nuclear Analytical Chemistry (NAC) section within the Chemical Sciences Division (CSD) at Oak Ridge National Laboratory (ORNL) is currently working with NBLPO to set up laboratory and measurement capabilities to provide measurements and capabilities for production and/or recertification of existing and future CRMs for uranium assay. The NBL-developed high-precision titration (HPT) method is a critically-evaluated, extremely precise and accurate primary method utilized for the determination of uranium content in a variety of uranium materials. The HPT method, combined with detailed balance weighing protocols, provides for an analytical methodology that is unsurpassed in precision and one in which all sources of error have been evaluated, a requirement of CRM certification. HPT capability within the United States was lost with the closure of the labs at NBL. The NAC has been collaborating with NBLPO to stand up and demonstrate the capability to perform uranium assay via HPT at ORNL. HPT can produce results with an expanded uncertainty of approximately 0.01% for pure uranium compounds, with typical precisions of <0.006%. The major tasks required to stand up the method at ORNL were the refurbishment of a dedicated lab and equipment setup, procedure development, analyst training, establishing method-specific quality assurance, and qualification of an analyst to perform the method. This report summarizes these tasks, outlines the documents drafted, and gives the outcome of the qualification titrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Strain gage selection in loads equations using a genetic algorithm

Traditionally, structural loads are measured using strain gages. A loads calibration test must be done before loads can be accurately measured. In one measurement method, a series of point loads is applied to the structure, and loads equations are derived via the least squares curve fitting algorithm using the strain gage responses to the applied point loads. However, many research structures are highly instrumented with strain gages, and the number and selection of gages used in a loads equation can be problematic. This paper presents an improved technique using a genetic algorithm to choose the strain gages used in the loads equations. Also presented are a comparison of the genetic algorithm performance with the current T-value technique and a variant known as the Best Step-down technique. Examples are shown using aerospace vehicle wings of high and low aspect ratio. In addition, a significant limitation in the current methods is revealed. The genetic algorithm arrived at a comparable or superior set of gages with significantly less human effort, and could be applied in instances when the current methods could not.

Source record↗

Photometric calibration in u -band using blue halo stars

ABSTRACT We develop a method to calibrate u-band photometry based on the observed colour of blue Galactic halo stars. The Galactic halo stars belong to an old stellar population of the Milky Way and have relatively low metallicity. The ‘blue tip’ of the halo population – the main sequence turn-off (MSTO) stars – is known to have a relatively uniform intrinsic edge u-g colour with only slow spatial variation. In SDSS data, the observed variation is correlated with Galactic Latitude, which we attribute to contamination by higher metallicity disc stars and fit with an empirical curve. This curve can then be used to calibrate u-band imaging if g-band imaging of matching depth is available. Our approach can be applied to single-field observations at |b| > 30°, and removes the need for standard star observations or overlap with calibrated u-band imaging. We include in our method the calibration of g-band data with ATLAS-Refcat2. We test our approach on stars in KiDS DR 4, ATLAS DR 4, and DECam imaging from the NOIRLab Source Catalog (NSC DR2), and compare our calibration with SDSS. For this process, we use synthetic magnitudes to derive the colour equations between these data sets, in order to improve zero-point accuracy. We find an improvement for all data sets, reaching a zero-point precision of 0.016 mag for KiDS (compared to the original 0.033 mag), 0.020 mag for ATLAS (originally 0.027 mag), and 0.016 mag for DECam (originally 0.041 mag). Thus, this method alone reaches the goal of 0.02 mag photometric precision in u-band for the Rubin Observatory’s Legacy Survey of Space and Time (LSST).

79 ASTRONOMY AND ASTROPHYSICS↗

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ^(2) method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ^(2) method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ^(2) method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

Shinya Yamada↗