Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Application and evaluation of a pattern-based building energy model calibration method using public building datasets

Building performance simulation has been adopted to support decision making in the building life cycle. An essential issue is to ensure a building energy simulation model can capture the reality and complexity of buildings and their systems in both the static characteristics and dynamic operations. Building energy model calibration is a technique that takes various types of measured performance data (e.g., energy use) and tunes key model parameters to match the simulated results with the actual measurements. This study performed an application and evaluation of an automated pattern-based calibration method on commercial building models that were generated based on characteristics of real buildings. A public building dataset that includes high-level building attributes (e.g., building type, vintage, total floor area, number of stories, zip code) of 111 buildings in San Francisco, California, USA, was used to generate building models in EnergyPlus. Monthly level energy use calibrations were then conducted by comparing building model results against the actual buildings' monthly electricity and natural gas consumption. The results showed 57 out of 111 buildings were successfully calibrated against actual buildings, while the remaining buildings showed opportunities for future calibration improvements. Enhancements to the pattern-based model calibration method are identified to expand its use for: (1) central heating, ventilation and air conditioning (HVAC) systems with chillers, (2) space heating and hot water heating with electricity sources, (3) mixed-use building types, and (4) partially occupied buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic and rapid calibration of urban building energy models by learning from energy performance database

Urban building energy modeling (UBEM) is attracting increasing attention in the energy modeling filed. Unlike modeling a single building using detailed building systems information, UBEM generally uses limited high-level building stock data to infer default assumptions about building characteristics and operations. Additionally, this practice inherently brings uncertainty to UBEM. This study introduced a novel method of automatic and rapid calibration of UBEM based on the annual electricity and natural gas energy use data by learning the correlations between crucial model input parameters and the building energy use from the reference building models. A case study was presented to calibrate 72 large office buildings built before 1978 in San Francisco. Seventeen model parameters were selected and Monte Carlo sampling was used to create 1000 samples that reasonably represent the parameter space. Then 1000 simulations were performed for the reference building model to create an energy performance database. The results showed that by learning from the energy performance database, it took less than four simulation runs on average to calibrate a building model. After the calibration, the distributions of each parameter were obtained to replace their single predefined default values. For example, the default lighting power density of 21.39 W/m 2 was calibrated to be 7.50 W/m 2 on average. The case study successfully demonstrated the effectiveness of the novel calibration method for UBEM in the mild climate. The method will be further tested in future for other climate zones and other building types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bayesian calibration of a physics-based crystal plasticity and damage model

In this work, we present a model parameter calibration procedure for a physics-based crystal plasticity model. The calibration process utilizes a powerful statistics-based Bayesian calibration method. Calibration of the crystal plasticity parameters makes use of experimentally-measured data, i.e. compressive stress–strain response, from $\langle$100$\rangle$ and $\langle$123$\rangle$ single crystal copper dynamically loaded via Kolsky bar tests. The calibration of damage parameters is achieved using experimentally-measured free-surface velocity history data from plate impact test on $\langle$100$\rangle$ and $\langle$110$\rangle$ single crystal copper, which generates shock compression followed by dynamic tensile failure. A validation assessment is then carried out by comparing the calibrated model predictions and experimental measurements of the dynamic tensile damage generated in an impacted bicrystal copper plate. Lastly, a model-informed rationale for the experimentally-observed dependence of the spatial distribution of ductile damage (porosity) on crystallography is provided.

42 ENGINEERING↗

A rigorous physics-based enhanced parameter estimation (EPE) methodology for calibration of building energy simulations

Buildings rarely perform as designed/simulated and there are numerous tangible benefits if this gap is reconciled. A new scientifically rigorous yet pragmatic methodology for calibrating building energy simulations - called Enhanced Parameter Estimation (EPE) - is proposed that allows physically relevant parameter estimation rather than a blind force-fit to energy use data. Starting with a rapidly created simulation model, calibration is performed in two stages: (a) building shell calibration with the HVAC system replaced by an ideal system that meets the loads (b) HVAC system calibration with the building shell and all internal loads replaced by a box with only process loads. In the first stage, EPE identifies a small number of high-level heat flows in the energy balance, calculates them with specifically tailored individual driving functions, introduces physically significant parameters to best accomplish energy balance, and, estimates the parameters and their uncertainty bounds. Calibration is thus done with corrective heat flows without any arbitrary tuning of input parameters. Calibration accuracy is enhanced by machine learning of the residual errors. The EPE methodology is demonstrated by means of: a synthetic building and an actual 75,000 sq. ft. building in Pennsylvania. Future work needed for widespread application is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. Here, the expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

47 OTHER INSTRUMENTATION↗

Spatiotemporal Automatic Calibration of Infrastructure Lidar, Radar, and Camera with a Global Navigation Satellite System

Robust and accurate perception is important for modern intelligent transportation systems (ITS), which use sensors of various modalities for data fusion to create a digital twin of an intersection. Sensor calibration is an important process that creates a unified coordinate frame for the sensor output data so that it can be used for data fusion. Classical approaches for sensor calibration are time-consuming, require an overlapping field of view for feature matching, and are not feasible for ITS application as they cause disruptions in the flow of traffic. In this paper, we present a spatiotemporal automatic calibration approach to calibrate multiple infrastructure lidar, radar, and cameras installed at a traffic intersection. The approach uses global navigation satellite system (GNSS) positioning information shared by connected vehicles, and when the vehicle is detected by the sensor, we match the sensor detections with the GNSS coordinates. The proposed algorithm is evaluated with a real-world dataset utilizing detections from two radars, cameras, and lidars with a test vehicle instrumented with a post-processing kinematic (PPK)-corrected GNSS driving past the sensors installed at a four-way traffic intersection. The experimental results show that the proposed automatic calibration approach can achieve the transformation with a root mean squared error of less than 0.5 for radar and lidar and less than 2 for camera detections. The ability to rapidly calibrate sensors not only benefits initial installations, but can also be used for system health monitoring, while utilizing available connected vehicle data to test the real-time sensor fidelity and operational status.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Revised astrometric calibration of the Gemini Planet Imager

We present a revision to the astrometric calibration of the Gemini Planet Imager (GPI), an instrument designed to achieve the high contrast at small angular separations necessary to image substellar and planetary-mass companions around nearby, young stars. We identified several issues with the GPI data reduction pipeline (DRP) that significantly affected the determination of the angle of north in reduced GPI images. As well as introducing a small error in position angle measurements for targets observed at small zenith distances, this error led to a significant error in the previous astrometric calibration that has affected all subsequent astrometric measurements. We present a detailed description of these issues and how they were corrected. We reduced GPI observations of calibration binaries taken periodically since the instrument was commissioned in 2014 using an updated version of the DRP. These measurements were compared to observations obtained with the NIRC2 instrument on Keck II, an instrument with an excellent astrometric calibration, allowing us to derive an updated plate scale and north offset angle for GPI. This revised astrometric calibration should be used to calibrate all measurements obtained with GPI for the purposes of precision astrometry.

79 ASTRONOMY AND ASTROPHYSICS↗

A Technical basis for in-house calibration of 252 Cf neutron source emission rates

10CFR835 stipulates that radiation protection instruments must be calibrated at least annually. Accordingly, calibration of dose rate instruments are reliant on well-known reference fields. The neutron-free-in-air facility (NFIA) located at TA36-0214 provides such a capability for neutron remmeters. One of the reference NFIA sources, 252 Cf, must be replaced every 8-10 years due to its relatively short half-life (2.645 ± 0.008 y). In the past, each newly purchased 252 Cf source has been calibrated at NIST using the Mn-bath technique prior to shipping to LANL. However, because of COVID-19 complications, the most recently acquired 252 Cf source (FTC-CF-7167) has been stored at LANL pending approval to ship to NIST for calibration. Due to the considerable expense in transporting the source to and from NIST, this TBD was written to demonstrate that new sources can be accurately calibrated via intercomparison measurements with older NIST-calibrated 252 Cf sources. It had been previously noted that such measurements yielded emission rates that agreed very well with the official rates established by NIST

252cf↗

Towards Robust Calibration of the AWSD Reactive Burn Model

Calibration of a reactive burn model for detonation of high explosive is an important step towards predictive hy drodynamic simulations of detonation. A typical calibration consists of varying model parameters (e.g., rate constants, activation energies) until results of hydrodynamic simulations match the experimental data for a certain set of ex periments. Hydrodynamic simulations of the dependence of steady detonation velocity on the radius of a cylindrical high-explosive charge - often used in such calibrations - can be computationally expensive. In this work, we propose a method where such expensive simulations are performed infrequently, and only to parameterize and refine a surrogate model for the dependence of the detonation velocity on calibrated parameters. The method is developed, implemented and applied to an example problem - calibration of the AWSD reactive burn model for important high explosive PBX 9502. Two different flavors of the surrogate model are investigated, and the calibration is performed successfully.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Additional Calibration of the Ultraviolet Imaging Telescope on Board AstroSat

Results of the initial calibration of the Ultra-Violet Imaging Telescope (UVIT) were reported earlier by Tandon et al. The results reported earlier were based on the ground calibration as well as the first observations in orbit. Some additional data from the ground calibration and data from more in-orbit observations have been used to improve the results. In particular, extensive new data from in-orbit observations have been used to obtain (a) new photometric calibration that includes (i) zero points, (ii) flat fields, and (iii) saturation; (b) sensitivity variations; (c) spectral calibration for the near ultraviolet (NUV; 2000–3000 Å) and far ultraviolet (FUV; 1300–1800 Å) gratings; (d) point-spread function; and (e) astrometric calibration including distortion. Data acquired over the last three years show continued good performance of UVIT with no reduction in sensitivity in both UV channels.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatiotemporal Automatic Calibration of Infrastructure Lidar, Radar, and Camera with a Global Navigation Satellite System: Preprint

Robust and accurate perception is important for modern intelligent transportation systems (ITS), which use sensors of various modalities for data fusion to create a digital twin of an intersection. Sensor calibration is an important process that creates a unified coordinate frame for the sensor output data so that it can be used for data fusion. Classical approaches for sensor calibration are time-consuming, require an overlapping field of view for feature matching, and are not feasible for ITS application as they cause disruptions in the flow of traffic. In this paper, we present a spatiotemporal automatic calibration approach to calibrate multiple infrastructure lidar, radar, and cameras installed at a traffic intersection. The approach uses global navigation satellite system (GNSS) positioning information shared by connected vehicles, and when the vehicle is detected by the sensor, we match the sensor detections with the GNSS coordinates. The proposed algorithm is evaluated with a real-world dataset utilizing detections from two radars, cameras, and lidars with a test vehicle instrumented with a post-processing kinematic (PPK)-corrected GNSS driving past the sensors installed at a four-way traffic intersection. The experimental results show that the proposed automatic calibration approach can achieve the transformation with a root mean squared error of less than 0.5 for radar and lidar and less than 2 for camera detections. The ability to rapidly calibrate sensors not only benefits initial installations, but can also be used for system health monitoring, while utilizing available connected vehicle data to test the real-time sensor fidelity and operational status.

ADVANCED PROPULSION SYSTEMS↗

Application of Indirect Quantification of 133mXe to Calibration of HPGe Detector

The INL Noble Gas Laboratory provides intercomparison samples for the noble gas analysis laboratories as part of the CTBTO PrepCom IMS. Xe-133m is one of the four relevant radionuclides in nuclear explosion monitoring. Without commercially available Xe-133m calibration standards laboratories must create and improve calibration methods. Improvements in calibration methods at the INL NGL benefit the CTBTO PrepCom through better certified values for Xe-133m intercomparison samples. Calibration of High Purity Germanium detectors for Xe-133m quantification is complicated by the coexistence of Xe-133 in samples under analysis. Xe-133 is typically produced in larger quantities, has higher gamma emission probabilities, and its gammas are detected more efficiently than Xe-133m. Xe-133m activity of samples can be indirectly inferred through the 133:133m activity ratio of a batch of material, and the Xe-133 counts in the assay of a small aliquot of the same material. This indirect quantification method can be leveraged to perform detector calibrations for quantification of Xe-133m. Calibrations can be performed by inferring the Xe-133m to certify the sample, and direct counting to determine detector efficiency. A comparison of method results will be shown.

133mXe↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emulator-based Bayesian calibration of a subglacial drainage model

Subglacial drainage models, often motivated by the relationship between hydrology and ice flow, sensitively depend on numerous unconstrained parameters. We explore using borehole water-pressure time series to calibrate the uncertain parameters of a popular subglacial drainage model, taking a Bayesian perspective to quantify the uncertainty in parameter estimates and in the calibrated model predictions. To reduce the computation time associated with Markov Chain Monte Carlo sampling, we construct a fast Gaussian process emulator to stand in for the subglacial drainage model. We first carry out a calibration experiment using synthetic observations consisting of model simulations with hidden parameter values as a demonstration of the method. Using real borehole water pressures measured in western Greenland, we find meaningful constraints on four of the eight model parameters and a factor-of-three reduction in uncertainty of the calibrated model predictions. These experiments illustrate Gaussian process-based Bayesian inference as a useful tool for calibration and uncertainty quantification of complex glaciological models using field data. However, significant differences between the calibrated model and the borehole data suggest that structural limitations of the model, rather than poorly constrained parameters or computational cost, remain the most important constraint on subglacial drainage modelling.

58 GEOSCIENCES↗

Machine Learning Calibration of Groundwater Table Depth in ELM: Impact on Land Surface Hydrology and Land‐Atmosphere Fluxes

Accurate representation of groundwater table depth (GWTD) is crucial for simulating hydrological cycling in Earth system models (ESM). Nevertheless, there is a notable gap in the literature regarding the validation of GWTD simulations in ESMs and their subsequent impact on downstream hydrological components. This study explores the calibration of parameterization of global GWTD using machine learning within the Energy Exascale Earth System Model (E3SM) Land Model (ELM). Despite achieving significant gains in simulating GWTD through calibration, offline ELM simulations unexpectedly show that these improvements do not translate to substantial enhancements in model performance for other key hydrological variables, including soil moisture (SM), runoff, groundwater contribution to runoff or base flow index (BFI), and evapotranspiration and its partitioning. The performance in SM and runoff was even degraded in some regions, while BFI was mostly overestimated. Although there is significant improvement in GWTD within the critical range of 1–5 m, where groundwater traditionally influences land surface energy fluxes, these improvements occurred mostly in humid areas where the impact of GWTD on surface processes is minimal. Although the impacts of model calibration are generally small in offline ELM simulations, coupled land-atmosphere simulations exhibit much stronger responses to GWTD calibration, highlighting the role of land-atmosphere feedbacks in Earth system modeling. These findings underscore the need for integrated calibration strategies that simultaneously optimize multiple hydrological variables. However, if a single-variable approach is necessary, it is crucial to establish clear priorities for calibration, identifying the most critical variables that have the greatest impact on overall model performance.

Fang, Yilin [Pacific Northwest National Laboratory↗

Calibrating Microscopic Car-Following Models for Adaptive Cruise Control Vehicles: Multiobjective Approach

Adaptive cruise control (ACC) vehicles are the first step toward comprehensive vehicle automation. However, the impacts of such vehicles on the underlying traffic flow are not yet clear. Therefore, it is of interest to accurately model vehicle-level dynamics of commercially available ACC vehicles so that they may be used in further modeling efforts to quantify the impact of commercially available ACC vehicles on traffic flow. Importantly, not only model selection but also the calibration approach and error metric used for calibration are critical to accurately model ACC vehicle behavior. In this work, we explore the question of how to calibrate car following models to describe ACC vehicle dynamics. Specifically, we apply a multi-objective calibration approach to understand the tradeoff between calibrating model parameters to minimize speed error vs. spacing error. Three different car-following models are calibrated for data from six vehicles. The results are in line with recent literature and verify that targeting a low spacing error does not compromise the speed accuracy whether the opposite is not true for modeling ACC vehicle dynamics.

33 ADVANCED PROPULSION SYSTEMS↗