Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building operation control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Fault Diagnosis in HVAC Chillers

Modern buildings are being equipped with increasingly sophisticated power and control systems with substantial capabilities for monitoring and controlling the amenities. Operational problems associated with heating, ventilation, and air-conditioning (HVAC) systems plague many commercial buildings, often the result of degraded equipment, failed sensors, improper installation, poor maintenance, and improperly implemented controls. Most existing HVAC fault-diagnostic schemes are based on analytical models and knowledge bases. These schemes are adequate for generic systems. However, real-world systems significantly differ from the generic ones and necessitate modifications of the models and/or customization of the standard knowledge bases, which can be labor intensive. Data-driven techniques for fault detection and isolation (FDI) have a close relationship with pattern recognition, wherein one seeks to categorize the input-output data into normal or faulty classes. Owing to the simplicity and adaptability, customization of a data-driven FDI approach does not require in-depth knowledge of the HVAC system. It enables the building system operators to improve energy efficiency and maintain the desired comfort level at a reduced cost. In this article, we consider a data-driven approach for FDI of chillers in HVAC systems. To diagnose the faults of interest in the chiller, we employ multiway dynamic principal component analysis (MPCA), multiway partial least squares (MPLS), and support vector machines (SVMs). The simulation of a chiller under various fault conditions is conducted using a standard chiller simulator from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). We validated our FDI scheme using experimental data obtained from different types of chiller faults.

Choi, Kihoon↗

Developing Flexible, Networked Lighting Control Systems That Reliably Save Energy in California Buildings

An important strategy to meet California's ambitious energy efficiency goals is to use innovative wireless communications, embedded sensors, data analytics and controls to significantly reduce lighting energy use in commercial buildings. This project developed a suite of networked lighting solutions to further this goal. The technologies include a platform for low-cost sensing, distributed intelligence and communications, the “PermaMote,” which is a self-powered sensor and controller for lighting applications. The project team also developed a task ambient daylighting system that integrates sensors with data-driven daylighting control using an open communication interface, called the “Readings-At-Desk” (RAD) system. To address the problem of building occupants being confused about how to operate traditional lighting control systems, the research team created content that could be the basis for a user interface standard for lighting controls. Finally, to address the difficulty of ensuring that advanced lighting control systems actually deliver their promised energy savings, the project team developed a new method for evaluating and specifying lighting systems’ performance. The research team validated these technologies in the laboratory, showing significant lighting energy savings, up to 73% for the PermaMote sensor system from occupancy control and daylight dimming features, compared to the same light source (LED replacement lamps) operated via simple on/off scheduling. The project team also developed a proposed standard lighting data model and user interface elements, which were contributed to the ANSI Lighting Systems Committee (C137) for standardization. Existing data models are incomplete and inconsistent, whereas the lighting-specific data model developed here is clear and comprehensive, to serve as a starting point for creating common, universally agreed upon semantic definitions of key lighting parameters, to promote interoperability. For the task on verifiable performance of lighting systems, the project team developed a more effective metric for capturing the actual energy impact of a lighting system over time — the energy usage intensity (kWh/ft2/year). Three commercial lighting systems were tested in FLEXLAB® using this new metric, and the tests show a wide range in the accuracy of the self-reported energy-use metric, from 0.5% to 28% error compared to direct measurement of lighting energy using dedicated submeters. Overall, the project team estimates that these advanced technologies can reduce California office lighting energy use by 20% (above and beyond normal advanced lighting controls mandated by Title 24), resulting in about 1,600 GWh/year in savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-driven building energy modeling with feature selection and active learning for data predictive control

Three gaps impede the development of cost-effective and accurate data-driven building energy modeling/models (DBEM) for energy forecasting and predictive control strategies. Gap 1: data bias is common in building operation data, but this topic is hardly studied in DBEM; Gap 2: high data dimensionality is common in DBEM, but a systematic and scalable methodology is lacking to solve the problem; Gap 3: the interactions between data bias and high dimensionality have not been systematically studied for DBEM and predictive control in buildings. In this work, to address the three gaps mentioned above, we develop a framework that integrates active learning and feature selection for DBEM used for whole building data predictive control (or DPC, which is a branch of model predictive control). The framework provides a systematic methodology and automatic workflow that starts with raw data from building automation systems to the establishment of data-driven energy models for DPC controllers. The developed strategies and framework are evaluated in a virtual testbed based on EnergyPlus and BCVTB. Improved performance and reduced computational complexity are observed from the DBEM built with the developed framework, as well as the DPC controller based on that DBEM, indicating the effectiveness of the developed framework.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The noise environment of a school classroom due to the operation of utility helicopters

Noise measurements under controlled conditions have been made inside and outside of a school building during flyover operations of four different helicopters. The helicopters were operated at a condition considered typical for a police patrol mission. Flyovers were made at an altitude of 500 ft and an airspeed of 45 miles per hour. During these operations acoustic measurements were made inside and outside of the school building with the windows closed and then open. The outside noise measurements during helicopter flyovers indicate that the outside db(A) levels were approximately the same for all test helicopters. For the windows closed case, significant reductions for the inside measured db(A) values were noted for all overflights. These reductions were approximately 20 db(A); similar reductions were noted in other subjective measuring units. The measured internal db(A) levels with the windows open exceeded published classroom noise criteria values; however, for the windows-closed case they are in general agreement with the criteria values.

Hilton, D. A.↗

Online transfer learning strategy for enhancing the scalability and deployment of deep reinforcement learning control in smart buildings

In recent years, advanced control strategies based on Deep Reinforcement Learning (DRL) proved to be effective in optimizing the management of integrated energy systems in buildings, reducing energy costs and improving indoor comfort conditions when compared to traditional reactive controllers. However, the scalability and implementation of DRL controllers are still limited since they require a considerable amount of time before converging to a near-optimal solution. This issue is currently addressed in literature through the offline pre-training of the DRL agent. However this solution results in two main critical issues: (1) the need to develop a building surrogate model to perform the training task, and (2) the need to perform a fine-tuning process over several training episodes to obtain a near-optimal control policy. In this context, this paper introduces an Online Transfer Learning (OTL) strategy that exploits two knowledge-sharing techniques, weight-initialization and imitation learning, to transfer a DRL control policy from a source office building to various target buildings in a simulation environment coupling EnergyPlus and Python. A DRL controller based on discrete Soft Actor–Critic (SAC) is trained on the source building to manage the operation of a cooling system consisting of a chiller and a thermal storage. Several target buildings are defined to benchmark the performance of the OTL strategy with that of a Rule-Based Controller (RBC) and two DRL-based control strategies, deployed in offline and online fashion. The strategy adopted for OTL emulates the real world implementation with a simulation process by implementing the transferred DRL agent for a single episode in the target buildings. Target buildings have the same geometrical features and are served by the same energy system as the source building, but differ in terms of weather conditions, electricity price schedules, occupancy patterns, and building envelope efficiency levels. The results show that the OTL strategy can reduce the cumulated sum of temperature violations on average by 50% and 80% respectively when compared to RBC and online DRL while enhancing the energy system operation with electricity cost savings ranging between 20% and 40%. Furthermore, the OTL agent performs slightly worse than the offline DRL controller but it does not require any modeling effort and can be implemented directly on target buildings emulating a real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flexibility Estimation and Control of Thermostatically Controlled Loads with Lock Time for Regulation Service

A virtual battery model is a simple and general method to quantify aggregate flexibility from thermostatically controlled loads (TCLs), enabling grid operators to effectively coordinate a large number of flexible building loads with supplyside resources in power systems. Lockout controls are designed to avoid wear and tear resulting from short-cycling of hardware. The lock on/off time could significantly affect aggregate flexibility from TCLs to provide ancillary services and may even fail control algorithms designed without considering the lock time constraints. This paper focuses on flexibility estimation and control design for TCLs with lock time constraints to provide frequency regulation service. We first investigate the potential impacts of lock time on TCLs’ aggregate flexibility and control performance. Both control-dependent and control-independent power bounds are derived, based on either previous TCL switching operations or regulation signals. While the control-dependent method provides aggregate flexibility for a given control method, the control-independent method calculates the theoretical maximum of power bounds. Two control algorithms are proposed to better distribute flexibility over time and thereby improve signal tracking performance. The proposed methods are illustrated and validated through simulations.

Wang, Peng↗

Build Orientation Dependent Microstructure in Polymer Laser Sintering: Relationship to Part Performance and Evolution with Aging

Laser sintering (LS) is widely used to produce functional polymeric parts; however, the resulting parts are often limited by their porous structure, and performance of the part may be strongly anisotropic. Relating the structural features of parts to build process conditions or powder feedstock has been explored previously. In contrast, little is known regarding how the unique internal structures of LS parts evolve and relate to their performance later in their life cycle, for example, after use in a real-world operating environment. In this study, a tightly controlled LS build process and measurement campaign by standard X-ray computed tomography (XCT), supported by high-resolution synchrotron XCT, was used to benchmark the internal microstructure (e.g. porosity) as a function of four different build orientations in printed polyamide-12 (PA-12) parts. The initial performance of the parts after printing was characterized by tensile testing and dynamic mechanical analysis (DMA). Arrays of PA-12 parts in different build orientations were exposed to steam (under pressure) and air across multiple temperature and time points for the purposes of accelerated aging through oxidative and hydrolytic breakdown. Exposing parts to steam dramatically altered the internal microstructure and functional properties such as the glass transition temperature, tensile properties, and damping behavior. Notably, post-aging XCT revealed large microstructural changes after only 40 h of steam treatment relative to the as-printed specimens. Furthermore, pore reorganization and changes in crystallinity occurred regardless of whether the steam temperature was aggressive enough to induce a significant loss in mechanical properties. The build orientation dependence on the aging rate was minimal with the relative trend in performance persisting across most metrics among the different orientations even after aging.

36 MATERIALS SCIENCE↗

Evaluation of Initial and Mid-Term Air Traffic Procedures for Urban Air Mobility Operations

Urban air mobility (UAM) operations are expected to expand in scale over the next several years as novel aircraft types, including electric vertical takeoff and landing aircraft, are certified and begin operations. These new aircraft may increase safety, decrease noise, and lower operating costs compared with helicopters, allowing them to operate in ways existing aircraft do not. It is vital that these expanded operations are compatible with and do not disrupt existing operations or the air traffic management system. To study the ways in which scaled UAM operations can best integrate in the national airspace system, NASA and Joby Aviation partnered to conduct a high-fidelity air traffic controller-in-the-loop study. Building on air traffic procedures used to manage high tempo operations in other parts of the airspace, new procedures, routes, and communications protocols were developed and tested by retired controllers in NASA’s Future Flight Central tower simulation facility. In addition, new cooperative airspace constructs in the form of corridors were developed to understand their potential contributions to even greater scales of operation. The controllers managed traffic scenarios in the Dallas-Fort Worth and Dallas Love Field airports consisting of fleets of up to 100 UAM aircraft operating alongside traditional traffic . Metrics for air traffic controller workload, duration of communications, departure delays, and other measures of allowable aircraft throughput were collected. The analysis indicates that using today’s procedures for initial UAM operations under nominal conditions could enable up to 40 operations per hour to an airport’s central terminal area if that involved crossing a runway and up to 55operations per hour if reaching the central terminal did not involve crossing a runway. Operations at these tempos did not delay or otherwise interfere with simulated runway traffic and were rated acceptable by the air traffic controllers. The new corridor constructs dramatically lowered controller workload in certain circumstances, suggesting they may be effective in further increasing the allowable scale of operations.

Urban Air Mobility↗

Evaluation of Initial and Mid-Term Air Traffic Procedures for Urban Air Mobility

Urban air mobility (UAM) operations are expected to expand in scale over the next several years as novel aircraft types, including electric vertical takeoff and landing aircraft, are certified and begin operations. These new aircraft may increase safety, decrease noise, and lower operating costs compared with helicopters, allowing them to operate in ways existing aircraft do not. It is vital that these expanded operations are compatible with and do not disrupt existing operations or the air traffic management system. To study the ways in which scaled UAM operations can best integrate in the national airspace system, NASA and Joby Aviation partnered to conduct a high-fidelity air traffic controller-in-the-loop study. Building on air traffic procedures used to manage high tempo operations in other parts of the airspace, new procedures, routes, and communications protocols were developed and tested by retired controllers in NASA’s Future Flight Central tower simulation facility. In addition, new cooperative airspace constructs in the form of corridors were developed to understand their potential contributions to even greater scales of operation. The controllers managed traffic scenarios in the Dallas-Fort Worth and Dallas Love Field airports consisting of fleets of up to 100 UAM aircraft operating alongside traditional traffic. Metrics for air traffic controller workload, duration of communications, departure delays, and other measures of allowable aircraft throughput were collected. The analysis indicates that using today’s procedures for initial UAM operations under nominal conditions could enable up to 40 operations per hour to an airport’s central terminal area if that involved crossing a runway and up to 55 operations per hour if reaching the central terminal did not involve crossing a runway. Operations at these tempos did not delay or otherwise interfere with simulated runway traffic and were rated acceptable by the air traffic controllers. The new corridor constructs dramatically lowered controller workload in certain circumstances, suggesting they may be effective in further increasing the allowable scale of operations.

Advanced Air Mobility↗

Stripping off the implementation complexity of physics-based model predictive control for buildings via deep learning

Over the past decade, model predictive control (MPC) has been considered as the most promising solution for intelligent building operation. Despite extensive effort, transfer of this technology into practice is hampered by the need to obtain an accurate controller model with minimum effort, the need of expert knowledge to set it up, and the need of increased computational power and dedicated software to run it. A promising direction that tackles the last two problems was proposed by approximate explicit MPC where the optimal control policies are learned from MPC data via a suitable function approximator, e.g., a deep learning (DL) model. The main advantage of the proposed approach stems from simple evaluation at execution time leading to low computational footprints and easy deployment on embedded HW platforms. We present the energy savings potential of physics-based (also called 'white-box') MPC applied to an office building in Belgium. Moreover, we demonstrate how deep learning approximators can be used to cut the implementation and maintenance costs of MPC deployment without compromising performance. We also critically assess the presented approach by pointing out the major challenges and remaining open-research questions.

Drgona, Jan↗

Fault-Tolerant Operation of Bosonic Qubits with Discrete-Variable Ancillae

Fault-tolerant quantum computation with bosonic qubits often necessitates the use of noisy discrete-variable ancillae. In this work, we establish a comprehensive and practical fault-tolerance framework for such a hybrid system and synthesize it with fault-tolerant protocols by combining bosonic quantum error correction (QEC) and advanced quantum control techniques. We introduce essential building blocks of error-corrected gadgets by leveraging ancilla-assisted bosonic operations using a generalized variant of path-independent quantum control. Using these building blocks, we construct a universal set of error-corrected gadgets that tolerate a single-photon loss and an arbitrary ancilla fault for four-legged cat qubits. Notably, our construction requires only dispersive coupling between bosonic modes and ancillae, as well as beam-splitter coupling between bosonic modes, both of which have been experimentally demonstrated with strong strengths and high accuracy. Moreover, each error-corrected bosonic qubit is comprised of only a single bosonic mode and a three-level ancilla, featuring the hardware efficiency of bosonic QEC in the full fault-tolerant setting. We numerically demonstrate the feasibility of our schemes using current experimental parameters in the circuit-QED platform. Finally, we present a hardware-efficient architecture for fault-tolerant quantum computing by concatenating the four-legged cat qubits with an outer qubit code utilizing only beam-splitter couplings. Our estimates suggest that the overall noise threshold can be reached using existing hardware. These developed fault-tolerant schemes extend beyond their applicability to four-legged cat qubits and can be adapted for other rotation-symmetrical codes, offering a promising avenue toward scalable and robust quantum computation with bosonic qubits. Published by the American Physical Society 2024

Physics↗

Towards Learning-Based Architectures for Sensor Impact Evaluation in Building Controls

Advanced control algorithms for building systems are known to have significant potential in reducing energy consumption while optimizing thermal comfort. The success of such algorithms is critically contingent on several different types of sensor systems, which are in turn, used for continuous monitoring, identification and estimation of several important building states, such as temperatures, humidity, air quality, power consumption and occupancy status. Nonidealities in any of these sensors can lead to significant performance degradation of the control functionalities, and may lead to unwanted sub-optimal building operation. In this paper, we provide a simulation example with a high-fidelity building model, for a particular use-case of advanced optimization-based control in buildings, i.e., occupancy-based controls. We show how imperfections in occupancy sensing can offset performance. Subsequently, we discuss a novel learning-based architecture to efficiently evaluate the impact of sensor nonidealities for building systems, in context of advanced control algorithms.

Bhattacharya, Saptarshi↗

Empower Wall: Active insulation system leveraging additive manufacturing and model predictive control

Buildings are one of the largest energy consumers worldwide, using large amounts of energy during their construction and for climate control during operation. Active insulation systems (AIS) have been shown to reduce the energy needed for climate control in buildings by dynamically regulating the heat transferred between a building’s interior and exterior. Infrastructure-scale additive manufacturing (AM) has the potential to reduce the resources needed for building construction. Combining these two technologies into a single building envelope would create a path towards more sustainable buildings. A test was conducted for the Federal Energy Management Program (FEMP) Energy Exchange training and trade show, in August 2021, to investigate a new building envelope design, termed the Empower Wall, that utilized an AIS and was constructed using AM. Model predictive control was implemented to manage operation of the Empower Wall in concert with the existing HVAC system. Finally, the prototype system demonstrated that the Empower Wall lowered total energy consumption and reduced the cost of energy used.

36 MATERIALS SCIENCE↗

Cost Reduction of School Bus Fleet Electrification With Optimized Charging and Distributed Energy Resources: Preprint

Considerations for electrifying school buses are presented with an analysis of battery sizing to match bus driving requirements. The charging and vehicle-to-building dispatch of the electric school buses were optimized to evaluate the potential to reduce the impact of the bus charging on the school's electric utility bill. Distributed energy resources (DER) and flexible building loads were also considered with the school bus electrification to evaluate the further reduction in energy costs with enhanced system integration and optimized dispatch. The effect of degradation on the school bus batteries was analyzed to determine if the smart charging and vehicle-to-building battery operation decreases the life of the battery. The results show that there is an opportunity to mitigate the increase of electric utility bills with improved charging controls and bi-directionally operating the school bus batteries to reduce building demand charges. The battery degradation analysis using dispatch with optimized charging and discharging shows acceptable battery life.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ACTIVE

The Automated Control Testbed for Integration, Verification, and Emulation (ACTIVE) framework is a software platform designed to support the optimized operation and management of a wide range of building types. It enables the development, testing, and validation of diverse control strategies, including AI-based, rule-based, and model-based approaches. The platform facilitates a seamless transition from simulation-based evaluation of control strategies to real-world field validation and deployment. ACTIVE supports the full building management lifecycle, encompassing data acquisition and management, system monitoring, optimized control, adaptive learning services, device dispatch and coordination, as well as advanced analytics and visualization. Together, these capabilities provide an integrated environment for improving building performance, operational efficiency, reducing energy cost, and reliability.

Smith, Robert [Oak Ridge National Laboratory (ORNL↗

Impact of Control on Availability and Cycling of Residential HVAC in a Real-World Experiment

Demand response is an important emerging part of smart grids and there is a large stream of research from theoretical and modeling perspectives. However, there is relatively little experimental evidence that could help researchers and building operators make informed decisions on best practices for modeling, developing, and deployment of control mechanisms. We contribute to the body of experimental research by providing numerical insights into the role and availability of residential HVAC systems for control. We share the findings on the duration of the cooling cycle, off cycle, and temperature settling time of HVAC systems from data collected from a smart neighborhood located in Atlanta, GA.

cycling↗

A three-year dataset supporting research on building energy management and occupancy analytics

Abstract This paper presents the curation of a monitored dataset from an office building constructed in 2015 in Berkeley, California. The dataset includes whole-building and end-use energy consumption, HVAC system operating conditions, indoor and outdoor environmental parameters, as well as occupant counts. The data were collected during a period of three years from more than 300 sensors and meters on two office floors (each 2,325 m 2 ) of the building. A three-step data curation strategy is applied to transform the raw data into research-grade data: (1) cleaning the raw data to detect and adjust the outlier values and fill the data gaps; (2) creating the metadata model of the building systems and data points using the Brick schema; and (3) representing the metadata of the dataset using a semantic JSON schema. This dataset can be used in various applications—building energy benchmarking, load shape analysis, energy prediction, occupancy prediction and analytics, and HVAC controls—to improve the understanding and efficiency of building operations for reducing energy use, energy costs, and carbon emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗