Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Structure–function relationships for squid skin-inspired wearable thermoregulatory materials

Wearable thermoregulatory technologies have attracted widespread attention because of their potential for impacting individual physiological comfort and for reducing building energy consumption. Within this context, the study of materials and systems that can merge the advantageous characteristics of both active and passive operating modes has proven particularly attractive. Accordingly, our laboratory has drawn inspiration from the appearance-changing skin of Loliginidae (inshore squids) for the introduction of a unique class of dynamic thermoregulatory composite materials with outstanding figures of merit. Herein, we demonstrate a straightforward approach for experimentally controlling and computationally predicting the adaptive infrared properties of such bioinspired composites, thereby enabling the development and validation of robust structure–function relationships for the composites. Our findings may help unlock the potential of not only the described materials but also comparable systems for applications as varied as thermoregulatory wearables, food packaging, infrared camouflage, soft robotics, and biomedical sensing.

Liu, Panyiming (ORCID:0000000242223670)↗

Transactive HVAC Agent - Design and Performance Evaluation

Transactive energy systems are playing an increasingly important role in the efficient and reliable marketbased operation of the power grid. Since a significant portion of the residential building energy consumption is from heating ventilation and air conditioning (HVAC) systems, HVAC is one of the most promising resources to provide load flexibility. However, utilizing HVAC flexibility to provide various grid services while simultaneously maintaining consumer comfort and cost-reductions is challenging. This paper presents a design of a transactive HVAC agent (T-HVAC) to be used as a supervisory control for the HVAC system that can simultaneously ensure comfort and cost-reduction. In particular, the T-HVAC a) estimates HVAC thermal dynamics, b) ensures optimal operations of the HVAC system, and c) participates into markets, and d) implements a market-based control via controlling the thermostat temperature set-point. The T-HVAC performance is demonstrated through multiple scenarios and illustrations.

Demand flexibility, distribution system, HVAC, Tra↗

transBEAM

Toolkit to implement and explore transfer learning-based strategies to address unsatisfactory accuracy of models for estimating building energy consumption when available field data for training is sparse or of unacceptable quality

Jain, Milan↗

Surrogate Model of Flexible Research Platform EnergyPlus Models to Enable Sensitivity Analysis

This letter report describes the surrogate models developed from the EnergyPlus model of Oak Ridge National Laboratory’s Flexible Research Platform. Two data-driven black-box models were developed, and the outputs of the surrogate models were compared with the EnergyPlus model. The two models developed are a multilayer perceptron deep learning model, and a long short-term memory (LSTM) neural network model. The three factors for selecting the black-box models are scalability, computation time, and accuracy. A total of 107 input variables were the dominant variables in determining the outputs of building energy consumptions and thermal comfort. A total of 54 output variables were identified as the prediction targets, including the system- and zone-level outputs. The large set of the simulation cases were generated by integrating sensor errors into an emulator based on EnergyPlus and Python EMS, which includes advanced control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. The surrogate models were developed based on a set of large-scale simulation runs (i.e., 4,000 runs) on a cloud platform. The comparison analysis shows that the two black-box models had good accuracy for predicting new outputs for sensitivity analysis using the root mean square error metric. As a next step, the developed surrogate models will be used to perform sensitivity analysis for different sensor impacts (e.g., sensor types, sensor locations).

42 ENGINEERING↗

Electrohydrodynamic Enabled Electrochemical Membrane Dehumidifier for Separate Sensible and Latent Cooling

In hot and humid parts of the world, air conditioning is a necessity for an adequate standard of living. Cooling and heating represent one-third of building energy consumption. When cooling humid air, a substantial amount of the cooling energy is absorbed by water vapor condensation. The dehumidification cooling load is referred to as the latent cooling load and the dry bulb cooling load is referred to as the sensible cooling load. In most residential applications, the total cooling load is processed by a vapor compression cycle. Processing the latent load separately would not only reduce energy consumption. It would also reduce the required refrigeration capacity. Refrigerants often have adverse ecological impacts, contributing to the greenhouse effect and depletion of the ozone layer. Reduction of the cooling capacity in a system could reduce the amount of refrigerant charge required.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype Courthouse Building Energy Model: Building Characteristics and Energy Simulation Results

To coordinate commercial building energy research activities, the US Department of Energy uses a suite of commercial prototype building models, which includes 16 building types and covers 80% of US commercial floorspace. Efforts are underway to expand this suite by developing prototype models for additional building types, including a courthouse. Informed by building design guides, databases, documented projects, and personal communication with courthouse design experts, a 3-story, 4-courtroom, 69,324 ft 2 building was considered as the prototype courthouse to represent an average-sized courthouse in the United States. This report documents the building and system characteristics of the prototype courthouse model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. To verify the energy simulation results, energy use statistics of existing courthouses from different building database are also presented. Based on the simulated energy use, the site energy use intensity of the prototype courthouse ranged from 45 to 159 kBtu/ft 2 compared with the average energy use intensity of 94.7 kBtu/ft 2 for the courthouse building type in the 2012 Commercial Building Energy Consumption Survey (CBECS) Data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Application of Schema Based Occupant-Centric Building Performance Metrics

Occupant behavior can significantly influence the operation and performance of buildings. Many occupant-centric key performance indicators (KPIs) rely on having accurate counts of the number of occupants in a building, which is very different to how occupancy information is currently collected in the majority of buildings today. To address this gap, the authors develop a standardized methodology for the calculation of percent space utilization for buildings, which is formulated with respect to two prevalent operational data schemas: the Brick Schema and Project Haystack. The methodology is scalable across different levels of spatial granularity and irrespective of sensor placement. Moreover, the methods are intended to make use of typical occupancy sensors that capture presence level occupancy and not counts of people. Since occupant-hours is a preferable metric to use in KPI calculations, a method to convert between percent space utilization and occupant-hours using the design occupancy for a space is also developed. The methodology is demonstrated on a small commercial office space in Boulder, Colorado using data collected between June 2018 and February 2019. A multiple linear regression is performed that shows strong evidence for a relationship between building energy consumption and percent space utilization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hygrothermal Performance of Bio-Based Materials in Residential Building Wall Envelope Systems

In the United States, building envelope systems contribute approximately 28% of building energy consumption, with walls being a primary factor. As the construction industry explores new approaches to lower the energy intensity needed to manufacture materials and, in turn, reduce energy consumption, bio-based materials are gaining attention as a promising alternative. While prior studies have demonstrated that bio-based materials can decrease material energy intensity, their long-term hygrothermal behavior within a whole residential wall system is not yet fully understood. This study aims to evaluate the potential of replacing Oriented Strand Board (OSB) and drywall in residential wall systems with bio-based alternatives. The research focuses on two bio-based materials, assessing their hygrothermal performance under Chicago climate condition (Climate Zone 5). To achieve that, a series of laboratory experiments were conducted to measure key properties of the bio-based materials such as thickness, dimensions, density, thermal conductivity (as a function of temperature and humidity), moisture-dependent permeance and water vapor permeability (WVP), and sorption isotherms. These properties were then used in WUFI® simulations to predict the moisture durability of a standard residential wall system in Climate Zone 5. Results show that substituting OSB and drywall with bio-based materials can achieve acceptable moisture durability, effectively mitigating risks of mold growth and structural damage over time.

Palani, Hevar [ORNL] (ORCID:0000000220211994)↗

Smart and Efficient Building Envelopes: Thermal Switches and Thermal Storage for Energy Savings and Load Flexibility

The building envelope has traditionally been seen as a static component. Much of the past thermal advancements in building envelopes has consisted of developing higher R/inch insulation. While a suitable approach for static situations, it does not consider the dynamic nature of the ambient environment or the varying needs of the electrical grid. This paper will examine three possible ways that building envelopes can be actively managed: 1. thermal switches, 2. thermal storage, and 3. the coupling of the two. Spurring innovation to make building envelopes smarter will help reduce building energy consumption and peak energy usage and contribute to flexibility in energy demand in the future.

Mumme, Sven↗

The Building Science Advisor: A Web-Based Tool to Assess the Durability of Building Envelope Components

The Department of Energy (DOE) and Oak Ridge National Laboratory (ORNL) have developed an innovative new design tool that will put building science expert advice in the hands of every building designer who cares to manage moisture risk in high-R envelope components. As modern buildings become increasingly more airtight, constructed with modern labor-saving materials, and equipped with air-conditioning, they have become less forgiving to moisture intrusion. The Building Science Advisor (BSA) provides building science knowledge and advice based on expert experience, field measurements, laboratory tests, and computer simulations.BSA users are prompted to enter relevant information about the building location, design, and material selection options like cladding, structural system, and insulation. Influential factors such as climate, building air tightness, material properties, and internal moisture loads are also considered to estimate and compare the moisture durability performance of several design options. If the BSA deems the assembly’s performance unsatisfactory, it will provide the reasons why, and suggest necessary changes to wall design to ensure more robust performance.Using the BSA tool enables building designers to confidently select assembly design characteristics that achieve their design goals with the least moisture durability risk. Links to design-specific guidance are also be provided to help users manage any remaining risk. This tool will further enable DOE’s Building Technologies Office (BTO) to meet its long-term energy goal of a 50% reduction in building energy consumption by reducing builder concern about using highly energy efficient wall systems.

Desjarlais, Andre Omer↗

A Modularized Urban Scale Building Energy Modeling Framework Designed with An Open Mind

In recent years, physics-based building energy modeling (BEM) has started being used to evaluate the performance of buildings in the context of connected communities and on an urban scale to study their aggregated energy use, interactions, and impacts on the energy supply infrastructure and environment. The development of urban-scale BEM solutions needs extensive effort. Existing attempts tend to focus on different aspects of BEM on an urban scale, such as collecting as-built building data from different information sources, integrating geometry modeling with geographic information systems (GISs), representing operational and occupancy profiles, automating workflow, processing and visualizing the results, and conducting large-scale simulations. Urban-scale BEM development would benefit from multi-disciplinary research areas and from an open platform to adopt advancements on data sources and tools. For these purposes, this research proposes a modularized bottom-up model creation and simulation framework that is built on the state-of-the-art BEM tools and can accommodate different building stock data. This framework uses a standardized schema to describe building design and operational characteristics, and it can be instantiated from different building survey datasets with heterogeneous structures. The paper demonstrates how thousands of surveyed buildings from the 2012 U.S. Energy Information Administration’s Commercial Buildings Energy Consumption Survey (CBECS) were one-to-one converted to EnergyPlus models through the schema and the model generation process, then simulated with distributed computing, and their results are summarized.

Lei, Xuechen↗

Energy consumption program: A computer model simulating energy loads in buildings

The JPL energy consumption computer program developed as a useful tool in the on-going building modification studies in the DSN energy conservation project is described. The program simulates building heating and cooling loads and computes thermal and electric energy consumption and cost. The accuracy of computations are not sacrificed, however, since the results lie within + or - 10 percent margin compared to those read from energy meters. The program is carefully structured to reduce both user's time and running cost by asking minimum information from the user and reducing many internal time-consuming computational loops. Many unique features were added to handle two-level electronics control rooms not found in any other program.

Stoller, F. W.↗

Analysis of the Financial Impacts of Building Performance Standard Penalties on Commercial Buildings in Aurora, Colorado

Buildings are responsible for 30% of total energy consumption worldwide. To address building energy, jurisdictions in the USA have enacted Building Performance Standards (BPS) legislation. The objective of BPS is to reduce energy consumption in buildings, thereby reducing the energy burden on utility infrastructure and other externalities. This is accomplished by setting mandatory energy use limits coupled with penalties for exceeding those limits. One of the key questions in BPS policymaking is how these penalties might impact the finances of building owners and tenants. This paper presents an analysis of BPS penalties in Aurora, Colorado, specifically targeting buildings impacted by the adopted statewide BPS legislation. Several BPS penalty structures were applied to the affected building stock in Aurora, and the potential impacts on building owner returns and tenant rents were estimated. The results show that for some combinations of building types and penalty structures, potential rent increases due to penalties could match or exceed typical yearly rent increases. The results also show that in most cases, for Aurora, there was no statistically significant difference in impact between buildings located in under-resourced and well-resourced areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗