Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Competitiveness Assessment of Decarbonizing Electricity and Process Heat Supply to a Campus with a Small Nuclear Reactor

This paper analyzes the competitiveness of siting a small nuclear reactor to support decarbonization of sites requiring tens of MW of electricity and/or process heat to support centralized heating and cooling system. This paper focuses on campuses as representative of sites with collections of buildings and research facilities with decarbonization needs represented by buildings heating, and electricity consumption by electrical loads which may include cooling via chilled water (e.g., for air conditioning and to cool down computer clusters). A nuclear reactor can be considered to decarbonize a site’s high-temperature steam generation used mostly for building heating needs, climate control, and hot water, by supplying process heat capabilities, while electricity decarbonization would be achieved mostly by the grid. However, a secondary application can be considered to maximize reactor utilization and avoid ramping down the reactor if the steam demand varies significantly throughout the year. Chilled water generation through steam-driven systems was identified as an attractive secondary option for the site analyzed, due to potential for plant design simplification, while electricity generation could be considered as well to reduce electricity purchases for a wider range of site applications. For a campus with peak 60MW thermal power demand, a small nuclear reactor with similar thermal power rating would almost eliminate CO2 emissions from steam generation and reduce electricity imports for chilled water production. A preliminary techno-economic feasibility study shows that a small nuclear reactor design that is optimized to support process heat can represent an economically feasible option when compared with other decarbonization alternatives.

Stauff, Nicolas E.↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗

Initial Systems-Level Assessment of a Distributed Direct Air Capture System Concept at the Urban-scale (UrbanDAC)

Direct Air Capture (DAC) systems offer a promising solution for mitigating global carbon emissions by directly removing ambient carbon dioxide (CO 2 ) from the atmosphere. While future DAC facilities are typically envisioned as being large and centralized, small-scale systems present an alternative approach with advantages such as adaptability and lower uptake costs. By harnessing waste heat from the built environment, such small-scale systems become distributed DAC at the urban scale (UrbanDAC) that benefit from existing urban infrastructure, while presenting challenges such as identifying eligible buildings and sustainable transportation and storage of captured CO 2 . Collaborating with engineering experts and developers of a DAC unit that can be co-located with cooling towers of existing commercial buildings, this study explores the systems-level implications of UrbanDAC using a geographically explicit multi-decision criteria analysis (MCDA) framework. By considering various infrastructure and environmental factors, network analysis and geospatial techniques are applied to identify optimal building candidates for distributed DAC units within Knoxville, Tennessee, USA, as a representative mid-size city. The selected outputs of the MCDA are used to explore a scenario that assumes a CO 2 collection and transport route for 20 high-ranking candidate buildings; total carbon emissions, EV energy consumption, and net carbon dioxide removal (CDR) are then calculated. Results suggest that the spatial variation of optimal candidates between thriving commercial areas is an important planning consideration. Examining the feasibility of UrbanDAC at an urban planning level provides valuable insights into the barriers and enabling conditions for CDR in cities, where the vast majority of CO 2 emissions are produced, and supports decision-making processes for the implementation of decarbonization initiatives. Through this initial assessment, this research acts as a pilot study for an emerging technology that highlights the importance of distributed DAC technologies in addressing climate change and emphasizes the need for further research and exploration in this domain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

Peak cooling load shift capability of a thermal energy storage system integrated with an active insulation system in US climate zones

This study aims to evaluate a thermal energy storage (TES) system integrated with an active insulation system (AIS) to form a TES + AIS integrated wall system as a partition and as a secondary cooling system to shift the peak load and reduce cooling energy consumption. To understand and demonstrate its cooling performance, the TES + AIS integrated wall system was installed in an office building in Oak Ridge, Tennessee. To investigate the effect of the TES + AIS integrated wall system in a typical office building and various climate zones, the US Department of Energy’s prototype office building model was modified to accommodate the proposed system. In this work, results showed that the minimum size of the proposed system to achieve energy savings varies depending on climate conditions. The minimum size of the proposed system for cooling energy saving and shifting peak cooling demand in climate zones 2, 3, and 5 is 29.7 m 2 , whereas it is 44.6 m 2 in zones 4 and 6. By installing the minimum size of the proposed system, 11.3 % to 16.4 % of cooling energy can be shifted during discharge hours in a representative summer day.

25 ENERGY STORAGE↗

Coupling subsurface and above-surface models for optimizing the design of borefields and district heating and cooling systems in the presence of varying water-table depth. In: Proceedings, 46th Workshop on Geothermal Reservoir Engineering

Dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes, without flow of groundwater. On the other hand, detailed simulation tools for subsurface heat and mass transfer exist, but these fall short in simulating above-surface energy systems. To support the design and operation of such systems, we have developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the ground. For the first, we use the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, we use the TOUGH simulator. TOUGH can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. In previous work, we described the coupling of these software packages, including how time-dependent boundary conditions for the borehole walls are synchronized for use in Modelica and TOUGH. We verified that the coupled Modelica/TOUGH code produced consistent results with the original Modelica code for an idealized problem in which heat transfer was purely by conduction in a uniform geologic medium. Here, we examine less idealized problems for which TOUGH’s advanced capabilities for modeling fluid flow are required. The first problem has a shallow vadose zone, and the second problem has a thicker vadose zone with a water-table depth that varies in time, which requires a fine vertical grid discretization for the TOUGH model.

Doughtry, Christine↗

An optimization framework for the network design of advanced district thermal energy systems

In this work, a topology optimization framework for district thermal energy systems is presented. The framework seeks to address the questions, for a given district, "What is the best subset of buildings to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?" A particle swarm optimization approach is validated to address the selection of the subset of buildings, and a graph theory-based heuristic is validated for selection of the network topology for any candidate subset of buildings. The framework is applied to a prototypical urban district for illustrative purposes. Additionally, modeling of prototypical districts revealed reductions in source energy use intensity for heating and cooling of 21-25% through the use of advanced district energy systems relative to code-compliant, building level systems. The framework identifies solutions with life cycle cost values 14% to 72% lower than that of base case scenarios based on conventional design approaches, depending on the base case scenario selected. Analysis of the search space indicates that topology optimization facilitates reductions in life cycle cost, source energy use intensity, and carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comminty Geothermal: Planning and Design of a Heating and Cooling System in Framingham, Massachusetts

These reports, plans, and drawings review the achievements of Home Energy Efficiency Team (HEET) and its partners to plan and design a network of interconnected ground-source heat pump systems, or geothermal network, in an area encompassing multiple environmental justice (EJ) neighborhoods in the City of Framingham, MA. The materials provided in this dataset include, a) stakeholder and design best practices, b) study on optimal method to interconnect geothermal loops, c) guidelines for monitoring and metering, d) operations and maintenance plans, e) permitting guidelines and f) 10-day driller tutorial curriculum. These materials can guide the efficient and ethical design of future geothermal networks nationwide. The capacity of the system is estimated at 217 tons and is designed to provide 100% of heating and cooling needs for the buildings connected to the loop. In this project, 80 boreholes are used as the main thermal resources, the distribution system (or loop) consists of 0.61 miles of an 8-inch single-pipe at ambient temperature, with the capacity to connect 44 buildings, including 13 apartment buildings from the Framingham Housing Authority, one transitional home, one school building and 29 single family homes. While Framingham already has a geothermal network loop that is currently in the commissioning stage, our proposed project is unique because it is the first utility-led expansion loop (2nd loop) project that will connect to an adjacent existing geothermal loop (1st loop) in a pre-existing neighborhood. Both the 1st and 2nd loops are being installed, owned and operated by Eversource Energy, the utility Deployment Partner.

15 GEOTHERMAL ENERGY↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

Datasets of a Multizone Office Building under Different HVAC System Operation Scenarios

Abstract This study provides an open-source dataset of the measured weather data, building indoor data, and system data under the different test settings. The test building is the two-story Flexible Research Platform building at the US Department of Energy’s Oak Ridge National Laboratory, in Oak Ridge, Tennessee. Four heating tests and three cooling tests were conducted. The 1-min interval of weather, building indoor data, and system data from each test setting are provided. Actual weather data were collected from a weather station installed on the roof. This paper describes information on the test building and installed sensors, data collection method, and data validation. The provided dataset can be employed to understand HVAC system conditions and building indoor conditions under different HVAC system operations and the performance of building envelope without HVAC system operation using free-floating test data. Additionally, it can be used for empirical validation of the building energy modelling engine.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling Subsurface and Above-Surface Models for Optimizing the Design of Borefields and District Heating and Cooling Systems

Accurate dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange for seasonal energy storage. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes without flowing groundwater. While detailed simulation tools for subsurface heat and mass transfer exist, these fall short in simulating above-surface energy systems. To support the design and operation of such systems, the study developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the subsurface. For the first, it uses the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, it uses the TOUGH simulator. The TOUGH family of codes can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. The study validated the coupled modeling approach by comparing the simulation results with one from the g-function based ground response model. It then looked into effects when the water table and the regional groundwater flow are considered in the ground, from the perspective of heat exchange between borehole and ground, and the electrical consumption of the district heating and cooling systems. To access the simulation models, please find the links in the submission: -- For coupled approach validation: see model Buildings.Fluid.Geothermal.Borefields.Examples.BorefieldsWithTough and Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from the "Modelica Building Library" resource, branch issue1495_tough_interface, commit a2667c0. -- For the study of the effect of water table: see model Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO, commit 760de49. -- For the study of the effect of regional groundwater flow: see Buildings.Examples.DistrictReservoirNetworks.Examples.Reservoir3Variable_TOUGH from he "Modelica Building Library" resource, branch issue1495_tough_interface_moreIO_3D, commit c2a2d2a. The coupling interface script "GrounResponse.py" can be found from the above links in the folder Buildings/Resources/Python-Sources. Also, the needed files for TOUGH simulation are in the folder Buildings/Resources/Python-Sources/ToughFiles that can be accessed through the above links. A brief description of these files is given below; detailed specifications for the first three files may be found in the TOUGH3 Users Guide (Jung et al., 2018) https://tough.lbl.gov/documentation/tough-manuals/. (1) INCON - initial conditions for each grid block (2) INFILE - main input file with material properties and control parameters (3) MESH - description of the computational grid (4) readsave - Modelica/TOUGH interface program: read the final output of TOUGH simulation after TOUGH time step and prepare for transfer to Modelica for next Modelica time step (5) readsave.inp - input parameters for program readsave (6) writeincon - Modelica/TOUGH interface program: write the output of Modelica after Modelica time step and prepare for transfer to TOUGH as initial conditions for the next TOUGH step (7) writeincon.inp - input parameters for program writeincon

15 GEOTHERMAL ENERGY↗

Staying cool: The development of India's pioneering energy efficiency policy for chillers

Abstract Chillers are the key energy‐consuming piece of equipment in most large space cooling systems. They can account for more than 40% of total energy consumption in any typical commercial building and in specific industrial building installations depending on the product and process. With climate change driving rapidly rising demand for commercial and industrial cooling, especially in emerging economies, energy efficiency policies for chillers are crucial to moderate future electricity demand and thereby minimize greenhouse gas emissions. However, most developing and emerging economies lack energy efficiency policies for this significant and growing cooling equipment sector. India recently announced new energy efficiency policies for chillers, projected to avoid 28 TWh of electricity consumption and 23 million tons of CO 2 emissions cumulatively through 2030. This article presents a case study of the unique challenges and solutions required to design a new energy efficiency policy for chillers in India. First, the energy consumed in chiller systems is sensitive to building occupancy, load changes, seasonal variations, operation and maintenance, and climatic conditions. In order to address these sensitivities, the chiller testing standard in India factors local weather and temperature conditions into energy performance ratings to account for these sensitivities. Further, every large chiller is a customized product, therefore developing a viable policy and implementation process required collaboration with international and national experts in standardization, manufacturers, building consultants, and testing laboratories. This article is categorized under: Energy Efficiency > Economics and Policy Solar Energy: Thermal ‐‐> Climate and Environment

Mukherjee, P. K.↗