Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “breakdown”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Elemental fractionation in aerosol laser-induced breakdown spectroscopy with nanosecond and femtosecond laser ablation

For the purpose of realizing atmospheric radiation plume tracking, laser-induced breakdown spectroscopy (LIBS) was performed to characterize Cs atomic emissions from airborne nanoparticles in a binary particle matrix using nanosecond and femtosecond laser ablation. As a surrogate to multi-element nuclear fallout particulates, both Cs and Na solutions were mixed with Cu at a 1:1.45 M concentration ratio and aerosolized to study elemental fractionation in atomic emissions, revealing Na I resonance emissions are enhanced whereas Cs I resonance emissions are reduced with Cu present despite sharing similar electronic and chemical properties. Femtosecond laser ablation reduced elemental fractionation effects by more than 50% while retaining the same temporal fractionation trends for Cs and Na. The origin of elemental fractionation in aerosol LIBS was further investigated using Al and Ti aerosols which revealed that the particle matrix induces changes to the local plasma temperature, population of atomic states, and subsequent molecular association and emission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing analytical merits of laser-induced breakdown spectroscopy of hydrogen isotopes using an orthogonal double-pulsing scheme

Accurate detection and quantification of hydrogen isotopes in solid materials are vital for diverse applications, including fusion energy, hydrogen storage, and tritium production. Laser-induced breakdown spectroscopy (LIBS) is a well established, rapid, standoff method for this purpose, but it faces challenges related to the analytical merits required for isotopic analyses. In this study, we enhance the analytical and detection capabilities of traditional single-pulse LIBS by implementing an orthogonal double pulsing approach, focusing on the analysis of a range of 2 H concentrations in Zircaloy-4 substrates (acting as a proxy for 3 H). The double-pulse experiments employed an orthogonal re-heating configuration with two nanosecond Nd:YAG lasers. We systematically evaluated critical parameters affecting the signal intensity in double-pulse LIBS, including interpulse delay, ambient gas pressure, and heating laser energy. Finally, our results demonstrate that employing an orthogonal double-pulse scheme significantly enhances 2 H α emission while minimizing line broadening and self-absorption, ultimately improving the technique’s analytical capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Real-time monitoring of trace noble gases using laser-induced breakdown spectroscopy—An investigation of the impact of bulk gas on plasma properties and sensitivity

The impact of Ar and He bulk gases on laser-induced breakdown spectroscopy (LIBS) real-time monitoring of trace Xe and Kr was assessed. LIBS is being developed as a monitoring tool for measuring noble gas transport in molten salt systems, in which traditional sensors may face challenges associated with radiation, corrosive materials, and/or mixed phases. The plasma temperature and electron densities of LIBS plasmas were measured in both static and various flowing Ar and He streams (0–5 L min −1 ). The use of an Ar bulk gas resulted in higher plasma temperature, greater electron densities by an order of magnitude, and extended plasma lifetime compared with when He bulk gas was used. Gas flow rate was found to have little impact on plasma temperature; however, its effect on electron density was significant, indicating the need to consider flow rate–specific models. Matrix effects on emission peaks were reported for both bulk gases. Due to these matrix effects, multivariate models were developed for Xe and Kr ranging from 0 to 700 ppm in both bulk gases. Although the predictive behavior was similar (root mean square error of prediction ranging from 11.1 to 20.6 ppm), the limits of detection were superior in He (Xe: 22.9 ppm, Kr: 30.4 ppm). Furthermore, these models were employed in demonstrative real-time tests (>1 h), which showed strong predictive precision (relative standard deviation <5 %) regardless of the bulk gas. Ultimately, this study provides a guide for the considerations required when developing gaseous LIBS models for real-time monitoring.

Gas flow effects↗

Calibration-Free Quantitative Analysis of Lithium-Ion Battery (LiB) Electrode Materials Using Laser-Induced Breakdown Spectroscopy (LIBS)

Recent years have seen a surge in the demand for high-performance battery electrode materials for automotive and various electronic device applications. Improving battery performance requires precise knowledge of the structure–composition properties of active electrode materials. To this effect, quantitative and precise estimation of the composition of advanced electrode materials, containing trace amounts of dopants, provide immense value toward developing next-generation high-capacity battery materials. Herein, we demonstrate the application of calibration-free laser-induced breakdown spectroscopy (LIBS) as a powerful analytical tool for rapid and reliable quantitative spectrochemical characterizations of layered Li metal oxide cathodes containing Mo and Cr dopants (<5 atom %). Specifically, we employ the LIBS using an internal calibration methodology to establish the quantitative elemental ratios of major (Ni, Mn, Co) and trace dopant (Cr, Mo) transition metals to bulk Li contents in diverse cathode material samples such as LiNi 0.5 Mn 0.5 O 2 (NM-50/50), LiNi 0.33 Mn 0.33 Co 0.33 O 2 (NMC), LiNi 0.317 Mn 0.317 Co 0.317 Cr 0.05 O 2 (Cr-doped NMC), and LiNi 0.5– x /2 Mn 0.5– x /2 Mo x O 2 ( x = 0.03, 0.04, 0.05) (Mo-doped NM-50/50) that were synthesized via sol–gel routes. The LIBS-estimated elemental compositions are in good agreement with the nominal stoichiometric values. Furthermore, ex situ LIBS characterizations presented here pave the path for future high-efficacy application of calibration-free quantitative LIBS for rapid in situ analyses of elemental composition changes in battery electrode materials under operation that need not resort to off-site analytical techniques requiring cumbersome sample preparations and/or external standards.

25 ENERGY STORAGE↗

Single-shot femtosecond laser-induced breakdown spectroscopy in low-density gases

Single-shot fs laser-induced breakdown spectroscopy (LIBS) has been used to interrogate low-density gases of H 2 ⁠, CH 4 ⁠, CO 2 ⁠, and H 2 O ranging from 0.5 × 10 15 to 9.1 × 10 15 cm −3 (15–275 mTorr). Strong spectral signatures were observed above the noise baseline for each test gas at all densities considered. Unique molecular signatures were observed for both CH 4 and CO 2 along with atomic features for each gas. The LIBS intensity response with respect to density was determined for each species using Voigt lineshape fitting or numerical integration. Finally, the collection and analysis of LIBS spectra of composite mixtures of CH 4 –CO 2 and CH 4 –H 2 demonstrates that the extraction of individual densities from gas mixtures is feasible at low densities.

Artificial neural networks↗

Machine Learning–Augmented Laser-Induced Breakdown Spectroscopy for Spectral Discrimination of Iron Oxalates

Enhanced characterization and phase identification of post-PUREX Pu Oxalates (PuOXA) are pivotal for nonproliferation and pre-detonation nuclear forensics. Despite significant advances in the characterization of PuO 2 samples, little is known about the impact of both the chemical structure and oxidation states of PuOXA (i.e., Pu(III) and Pu(IV)) have on optical emission signatures. Here, we demonstrate the analytical capabilities of laser-induced breakdown spectroscopy (LIBS) applied to Fe(II) and Fe(III) oxalate samples as surrogates for PuOXA, highlighting the discriminating features in the LIBS emission spectra arising from differences in the oxidation states within mixed FeOXA samples. We report the enhancement of spectral feature selection using Principal Component Analysis (PCA), which enables the analytical superiority of machine learning algorithms such as Linear Discriminant Analysis (LDA), Quadratic Discriminant Analysis (QDA), Partial Least Squares Regression (PLSR), Support Vector Regression (SVR), and Random Forest Regression (RFR) over conventional univariate techniques for phase discrimination and chemometric analysis. Cluster analysis revealed how both matrix effects and laser ablation influence cluster separability by introducing spectral artifacts that misdirect the maximization of variance. PCA-selected emission lines were used in the regression models, demonstrating that both univariate and multivariate linear regression models (i.e., PLSR and SVR) can achieve acceptable performance, with machine learning models outperforming conventional calibration regressions. Furthermore, the application of non-linearly activated PCA-selected emission lines illustrates how simplifying the data while retaining captured variance enables the use of less complex and more computationally efficient models. Furthermore, this is particularly evident in the underperformance of RFR, which suffers from increased computational costs and overfitting owing to its high complexity.

Oxalates↗

Parametric studies of stream instability-induced higher harmonics in plasma ionization breakdown near an emissive dielectric surface

Here, in this work, we comprehensively investigate the generation of higher harmonic (HH) electric fields normal to the applied rf electric field in multipactor-coexisting plasma breakdown by fully kinetic particle-in-cell (PIC) simulations and a theoretical model. Firstly, a base case at driving frequency 1 GHz, transverse rf electric field amplitude 3 MV m –1 , and background gas pressure 0.2 Torr, is studied in detail. The enhanced harmonic frequency observed is around ten times the fundamental rf frequency, significantly lower than the Langmuir frequency. A theoretical model reveals that the fundamental mechanism of HHs generation is stream–plasma instability, which originates from stream-like secondary electron emission interacting with plasma. The resulting HH frequency and the growth rate of its oscillating amplitude from the theoretical model, agree well with the PIC simulations. With increasing pressure, the HH oscillations are found to be significantly reduced. This is because at higher pressure the gas ionization rate is higher, which causes a more rapidly increasing plasma density, leaving less time for the growth of instability. Furthermore, the parameter space in terms of background gas pressure and rf field amplitude within which the HHs appear is revealed. Finally, the effect of the driving rf frequency on HHs is also investigated, and it is found that the instability-induced oscillating HHs field remains when the driving frequency is increased to 2 GHz, however, it is highly reduced at higher driving frequency of 5 GHz, as oscillations at the fundamental frequency start playing a more important role.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of fluorine distribution in shark teeth by laser-induced breakdown spectroscopy

Quantifying the chemical composition of fast-growing hard tissues in the environment can shed valuable information in terms of understanding ecosystems both prehistoric and current. Changes in chemical composition can be correlated with environmental conditions and can provide information about the organism's life. Sharks can lose 0.1 to 1.1 teeth/day, depending on species, which offers a unique opportunity to record environmental changes over a short duration of time. Shark teeth contain a biomineral phase that is made up of fluorapatite [Ca 5 (PO 4 ) 3 F], and the F distribution within the tooth can be correlated to tooth hardness. Typically, this is determined by bulk acid digestion, energy-dispersive X-ray spectroscopy (EDS), or wavelength-dispersive spectroscopy. Here we present laser-induced breakdown spectroscopy (LIBS) as an alternative and faster approach for determining F distribution within shark teeth. Using a two-volume laser ablation chamber (TwoVol3) with innovative embedded collection optics for LIBS, shark teeth were investigated from sand tiger (Carcharias Taurus), tiger (Galeocerdo Cuvier), and hammerhead sharks (Sphyrnidae). Fluorine distribution was mapped using the CaF 603 nm band (CaF, Β 2 Σ + → X 2 Σ + ) and quantified using apatite reference materials. In addition, F measurements were cross referenced with EDS analyses to validate the findings. Distributions of F (603 nm), Na (589 nm), and H (656 nm) within the tooth correlate well with the expected biomineral composition and expected tooth hardness. This rapid methodology could transform the current means of determining F distribution, particularly when large sample specimens (350 mm 2 , presented here) and large quantities of specimens are of interest.

36 MATERIALS SCIENCE↗

Analysis of hydrogen and lithium isotopes using Laser-Induced Breakdown Spectroscopy

The detection and quantification of hydrogen (1,2,3H) and lithium (6,7Li) isotopes are critical to several energy and defense application areas, including hydrogen storage, nuclear forensics, and safeguards/non-proliferation. In this context, laser-induced breakdown spectroscopy (LIBS) is very promising and it comes with certain advantages such as rapid detection, and standoff capability. Although LIBS provides experimental simplicity and is capable of detecting all elements in the periodic table in any phase (solid, liquid, or gas), there exist certain challenges for isotopic analyses of H and Li due to spectral broadening, the presence of closely spaced fine and hyperfine structures, and line distortion effects (e.g., self-absorption and self-reversal) present in laser-produced plasmas. This article reports recent developments in H and Li isotopic analysis using LIBS, and existing challenges.

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Quantification of Lanthanides in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy

To enable the deployment of molten salt reactor technology, the development of off-gas treatment systems and advanced monitoring tools capable of operating with high temperatures and radiation fields while delivering near real-time information is necessary. Here, we aim to fulfill this requirement and proposes laser-induced breakdown spectroscopy (LIBS) for monitoring molten salt aerosol streams. A sheath gas measuring method was developed to protect optical elements from aerosol particles and to ensure a relatively constant aerosol stream for measurement. An aqueous system was studied to demonstrate the utility of LIBS for monitoring possible fission products in an aerosol stream: Gd, Nd, and Sm up to 2000 parts per million (ppm). A calibration model was built using partial least squares (PLS) regression with five, six, and nine latent variables for Gd, Nd, and Sm, respectively. This calibration model successfully estimated the concentrations of three test samples, which were validated with inductively charged plasma optical emission spectroscopy measurements at a 99.9% confidence interval. To enhance these models, a genetic algorithm was used to filter the spectra before entering the PLS model, thereby limiting the spectral features being regressed to those with greater correlations to concentration. This allowed for the number of latent variables used in the PLS models to be reduced to four, three, and three for Gd, Nd, and Sm, respectively. Finally, the genetic algorithm-filtered PLS models were used to predict the concentrations of the aerosol stream on a real-time dataset and resulted in a 73%, 18%, and 25% improvement in root mean squared error of prediction compared to the original PLS models developed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monitoring Noble Gases (Xe and Kr) and Aerosols (Cs and Rb) in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy (LIBS)

In this study with surrogate materials we show that laser-induced breakdown spectroscopy (LIBS) is a robust tool with promising capability toward monitoring gaseous (Xe and Kr) and aerosol (Cs and Rb) species in an off-gas stream from a molten salt reactor (MSR). MSRs will continually evolve fission products into the cover gas flowing across the reactor headspace. The cover gas entrains Xe and Kr gases, along with aerosol particles, before passing into an off-gas treatment system. Univariate models of Xe and Kr peaks showed a strong correlation to concentration indicated by their coefficients of determination of 0.983 and 0.997, respectively. Multivariate models were built for all four analytes using partial least squares regression coupled with preprocessing steps including normalization, trimming, and/or genetic algorithm derived filters. The models were evaluated by predicting the concentrations of the analytes in four validation samples, in which all calibration models were successfully validated at a confidence interval of 99.9%. Finally, pressure controllers were used to regulate the mass flow rate of Kr flowing into the measurement cell in sinusoidal and stepwise waveforms to test the real-time monitoring capabilities of the regression models. Both univariate and partial least squares Kr models were able to successfully quantify the gas concentration in the real-time evaluation. The root mean squared error of prediction (RMSEP) values for these real-time tests were calculated to be 0.051, 0.060, and 0.121 mol% demonstrating the measurement systems’ capability to perform online monitoring with acceptable accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantification of Rare Earth Elements in the Parts Per Million Range: A Novel Approach in the Application of Laser-Induced Breakdown Spectroscopy

This work extends a previous percentage level concentration study of the optical emission spectra for six rare earth elements, europium (Eu), gadolinium (Gd), lanthanum (La), praseodymium (Pr), neodymium (Nd), and samarium (Sm), along with the transition metal, yttrium (Y) using laser-induced breakdown spectroscopy (LIBS). The concentration of these six rare earth elements and yttrium has been attempted for the first time systematically down to parts per million (ppm) concentration levels ranging from 30 to 300 ppm. In this study, the authors have developed multivariate models for each element capable of predicting concentration with acceptable to excellent levels of accuracy. Additionally, partial least squares regression coefficients were used to identify key spectral features able to be used in this lower concentration regime. This study has demonstrated that it is conceivable to quantify the six rare earth elements along with yttrium at low concentrations in the parts per million levels.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization and Optimization of a Spectral Window for Direct Gaseous Uranium Hexafluoride Enrichment Assay Using Laser-Induced Breakdown Spectroscopy

Through a systematic scanning of 235 U and 238 U emission lines between 280 nm and 745 nm, the optimal emission line for direct gaseous uranium hexafluoride (UF 6 ) enrichment assay using laser-induced breakdown spectroscopy (LIBS) was found. Screening for spectral features that are potentially useful for U isotopic analysis was gauged from the magnitude of the 235 U– 238 U isotopic shift and the signal-to-background ratio of the emission line through a parameter termed ΔSBR 235U–238U . The ΔSBR spectrum shows peaks at wavelength positions where there are strong lines with significant 235 U– 238 U shifts. The screening identified 13 spectral-window candidates, which were down selected based on their overall accuracy in predicting the 235 U enrichment of three UF 6 samples of natural (0.720 atom% 235 U) and low-enriched (4.675 atom% and 9.157 atom% 235 U) grades. The U(I) 646.498 nm emission line, with a determined 235 U– 238 U isotopic shift of -17.7 pm, was found to be the optimal spectral window for direct UF 6 enrichment assay. The root mean square error for enrichment assays on the three natural and low-enriched UF 6 samples, with each sample measured in six replicates, was 0.31% in absolute 235 U content. Each measurement comprised LIBS signals accumulated from 3000 laser shots. In conclusion, the analytical bias and precision were better than 0.5% and 0.3%, respectively, in absolute [ 235 U/( 235 U + 238 U)] ratios. Specific for the two low-enriched UF 6 samples, the relative standard deviations from six replicated measurements were around 2%.

47 OTHER INSTRUMENTATION↗

Detection of Off-Gassed Products From Molten Salts Using Laser-Induced Breakdown Spectroscopy

The detection of off-gassed sodium from molten sodium nitrate (NaNO 3 ) at temperatures between 330 °C and 505 °C and off-gassed calcium from molten lithium chloride–potassium chloride eutectic (LKE) mixtures at 510 °C with laser-induced breakdown spectroscopy (LIBS) was demonstrated. NaNO 3 and LKE samples were melted in a custom-built crucible that promoted the generation of off-gassed products from the molten sample. The off-gassed products were analyzed with a LIBS system designed to probe the high-temperature environment. Na D emission lines, Na(I)588.99 nm and Na(I) 589.59 nm, were detected from the NaNO 3 samples after reaching a temperature threshold, which indicated the occurrence of phase change. In LKE mixtures, the detection of Ca impurities at a concentration of 78 mg/kg was possible using the emission lines Ca(II) 393.66 nm and Ca(II) 395.85 nm. Furthermore, this work demonstrates the real-time monitoring capabilities of LIBS in high-temperature environments that simulate the conditions of molten salt reactors.

42 ENGINEERING↗

Design of a Molten Salt Flow Cell for Combined Absorbance and Laser-Induced Breakdown Spectroscopy for Online Measurements

A novel flow cell allowing for multiple optical spectroscopy measurements on flowing molten salts was designed, and demonstrative calibrations of impurities in aqueous samples were performed. Online compositional measurements of molten salts are of high interest to monitor the state of relevant solar and nuclear systems. Here, the Spectroscopic Configuration for Optical Real-Time Characterization of High-Temperature (SCORCH) fluids cell was designed to meet this need by providing optical access to a high-temperature molten salt sample stream without physical contact between the sample and window materials. Laser-induced breakdown spectroscopy (LIBS) was utilized to quantify Li, Cr, Fe, Ni, Sr, and Pr at concentrations ranging nominally from 0 to 315 mmol L −1 . Laser power, frequency, and plasma position were optimized to mitigate challenges associated with sample splashing. Univariate calibration models were built with R 2 > 0.98, percent root mean square error of cross-validation (%RMSECV) as low as 2.7%, and limits of quantification (LOQs) down to 4.1 mmol L −1 . Simultaneously, absorbance calibrations were developed for the applicable analytes (Cr, Ni, and Pr) using Beer’s law with a pathlength of 4.41 ± 0.10 mm. These models provide excellent quantification performance with R 2 > 0.999, %RMSECV as low as 0.6%, and LODs down to 0.08 mmol L −1 . Although these calibrations were performed for each spectroscopic technique separately, the two methods may be combined in the future through multivariate modeling and sensor fusion to provide more robust models with the benefits of both techniques (e.g., absorbance: oxidation state concentrations, LIBS: elemental concentration). Additionally, optimized spectrometers may be deployed to enhance sensitivity.

absorbance spectroscopy↗

Prediction of Breakdown in Air and Solid Dielectrics: A Complete Plasma Model from Discharge Initiation to Flashover (Final Technical Report)

A major challenge for most of the technologies of today, and the technologies of the future, is the compact and reliable design of electrical insulation systems for their electrical components. Although controlled low-temperature plasmas (LTPs) or non-thermal plasmas in air at atmospheric pressure are of interest for a wide range of technologies, the appearance of such discharges is considered highly undesirable in insulation systems because they are precursors of a breakdown or flashover, where complete insulation failure takes place. For non-thermal plasmas, often only one mechanism, or the transition from one discharge mechanism to another, has typically been studied to date. On the other hand, in the case of thermal plasma applications, the conditions following the occurrence of an electric arc or flashover have always been considered. Here, there is a big technical gap: there is no paper describing a complete plasma model simulating all discharge mechanisms and their transitions from discharge initiation to electrical arc and flashover. To address this gap, a complete plasma model for both thermal and non-thermal plasmas should be developed using a hydrodynamic approach. The project aimed to build the model. The work has the potential to address industrial applications and is of great importance to higher voltage systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Concept for an irradiation experiment to test a laser-induced breakdown spectroscopy off-gas sensor for molten salt systems

This paper focuses on laser-induced breakdown spectroscopy (LIBS) as an off-gas sensor and details a conceptual irradiation experiment to evaluate its performance in an environment that is more realistic of an operational molten salt reactor (MSR). MSRs are a promising advanced nuclear design that use high-temperature liquid salts as the coolant, fuel, or a combination of both. They will generate and subsequently evolve fission products into the reactor headspace during operation. These evolved fission products will necessitate an online off-gas system to treat the reactor cover gas before recycling it to the core. Such a system, especially during the early deployment phase, will benefit from online sensors to inform operators of the treatment system’s performance. Optical spectroscopy is well-suited to fit this task as it can be remotely deployed using fiber-optics and can detect most species at high frequencies. LIBS can detect nearly every element on the Periodic Table, stable or radioactive, making it an ideal candidate. The provided conceptual experiment discusses the facility requirements, salt capsule design, and detailed testing campaigns with corresponding simulated LIBS spectra.

47 OTHER INSTRUMENTATION↗