Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Annealing of focused ion beam damage in gold microcrystals: an in situ Bragg coherent X-ray diffraction imaging study

Focused ion beam (FIB) techniques are commonly used to machine, analyse and image materials at the micro- and nanoscale. However, FIB modifies the integrity of the sample by creating defects that cause lattice distortions. Methods have been developed to reduce FIB-induced strain; however, these protocols need to be evaluated for their effectiveness. Here, non-destructive Bragg coherent X-ray diffraction imaging is used to study the in situ annealing of FIB-milled gold microcrystals. Two non-collinear reflections are simultaneously measured for two different crystals during a single annealing cycle, demonstrating the ability to reliably track the location of multiple Bragg peaks during thermal annealing. The thermal lattice expansion of each crystal is used to calculate the local temperature. This is compared with thermocouple readings, which are shown to be substantially affected by thermal resistance. To evaluate the annealing process, each reflection is analysed by considering facet area evolution, cross-correlation maps of the displacement field and binarized morphology, and average strain plots. The crystal's strain and morphology evolve with increasing temperature, which is likely to be caused by the diffusion of gallium in gold below ~280°C and the self-diffusion of gold above ~280°C. The majority of FIB-induced strains are removed by 380–410°C, depending on which reflection is being considered. These observations highlight the importance of measuring multiple reflections to unambiguously interpret material behaviour.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Adaptive shape control of wavefront-preserving X-ray mirrors with active cooling and heating

This article describes the development and testing of a novel, water cooled, active optic mirror system (called “REAL: Resistive Element Adjustable Length”) that combines cooling with applied auxiliary heating, tailored to the spatial distribution of the thermal load generated by the incident beam. This technique is theoretically capable of sub-nanometer surface figure error control even at high power density. Tests conducted in an optical metrology laboratory and at synchrotron X-ray beamlines showed the ability to maintain the mirror profile to the level needed for the next generation storage rings and FEL mirrors.

42 ENGINEERING↗

Disruption Prediction and Avoidance in High Beta Long Pulse KSTAR Plasmas

DoE Grant DE-SC0016409 (Disruption Prediction and Avoidance in High Beta Long Pulse KSTAR Plasmas) supported a collaboration among Columbia University, the Princeton Plasma Physics Laboratory (PPPL), and the Plasma Science and Fusion Center (PSFC) at MIT to conduct research on the KSTAR tokamak at the National Fusion Research Institute (NFRI) in Korea to improve predictive capability for disruptions in tokamaks. This initiative included upgrades to kinetic diagnostics at KSTAR whose measurements form the basis for the disruption prediction models. The major thrust of the PPPL and PSFC work was implementing a capability at KSTAR to allow partially-polarized background light seen by the KSTAR Motional Stark Effect (MSE) diagnostic to be compensated by ‘wavelength interpolation’ rather than the traditional ‘beam modulation’ technique. This objective was completed on time and on budget, and the MSE Background Polychromator is currently functioning at KSTAR. Primary responsibility for maintaining and operating the MSE-BP was transferred to Nova Photonics, Inc. in 2019.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring internal structures and properties of terpolymer fibers via real-space characterizations

While significant research has investigated the processing and properties of high-performance terpolymer fibers, much remains to be understood about the internal nano- and microstructures of these fibers, and how these morphologies relate to fiber properties. Here we use a focused ion beam notch technique and multifrequency atomic force microscope mapping to characterize the internal structure and local mechanical properties within Technora ® fibers. We find a highly fibrillated structure that appears to connect with both the fiber’s molecular chemistry and full-fiber mechanical properties. In addition, through detailed comparisons with Kevlar ® K29 fibers, we find remarkable differences between the internal structures of the two fibers, and posit connections between our measurements and multifunctional performance studies from the literature.

36 MATERIALS SCIENCE↗

Serial Moire scanning phase contrast x-ray imaging

Method include emitting x-rays from an x-ray source, directing a first portion of the x-rays through an object grating situated adjacent to an object while the object is scanned relative to the object grating along a scan direction, directing a second portion of the x-rays through the object and subsequently through a detector grating without transmitting through the object grating, wherein the object grating and detector grating are adjacently arranged in a field of view of the x-rays sequentially with respect to each other in the scan direction, and receiving the first portion transmitted through the object and object grating with a first portion of a detector and receiving the second portion transmitted through the object and the detector grating with a second portion of the detector adjacent to the first portion of the detector. Systems are also disclosed, along with related techniques for beam hardening correction.

Miller, Erin A.↗

Radiation Effects in Used Next Generation Nuclear Fuel Reprocessing Strategies

Given global commitments to significantly increase nuclear energy capacity, it is now more important than ever to develop efficient used nuclear fuel (UNF) management strategies to encourage widespread adoption of closed fuel cycles. To achieve this ambitious goal, a comprehensive understanding of radiation effects is essential for these next generation technologies, as radiolysis often limits longevity and performance. Here, we present new findings on: (i) the radiation robustness and performance of advanced sulfur chloride-based chlorination processes in the presence of nuclear materials (Fig. 1A); and (ii) the impacts of voloxidized uranium and rhenium complexation on monoamide-based UNF direct dissolution strategies (Fig 1B). These studies employed a combination of time-resolved electron pulse and dose accumulation gamma and electron beam irradiation techniques.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Optical Characterization of the Keck Array and BICEP3 CMB Polarimeters from 2016 to 2019

The BICEP/Keck experiment (BK) is a series of small-aperture refracting telescopes observing degree-scale cosmic microwave background (CMB) polarization from the South Pole in search of a primordial B-mode signature. This B-mode signal arises from primordial gravitational waves interacting with the CMB and has amplitude parametrized by the tensor-to-scalar ratio r. Since 2016, BICEP3 and the Keck Array have been observing with 4800 total antenna-coupled transition-edge sensor detectors, with frequency bands spanning 95, 150, 220, and 270 GHz. Here we present the optical performance of these receivers from 2016 to 2019, including far-field beams measured in situ with an improved chopped thermal source and instrument spectral response measured with a field-deployable Fourier transform spectrometer. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We generate per-detector far-field beam maps and the corresponding differential beam mismatch that is used to estimate the temperature-to-polarization leakage in our CMB maps and to give feedback on detector and optics fabrication. The differential beam parameters presented here were estimated using improved low-level beam map analysis techniques, including efficient removal of non-Gaussian noise as well as improved spatial masking. These techniques help minimize systematic uncertainty in the beam analysis, with the goal of constraining the bias on r induced by temperature-to-polarization leakage to be subdominant to the statistical uncertainty. This is essential as we progress to higher detector counts in the next generation of CMB experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Sub-THz passive detector performance evaluation with RadiaBeam photoinjector

Wakefield accelerators, based on THz and mm-wave structures, promise to reach the highest energies in record small footprints. However, operation at such frequencies is associated with strong generation of dipole modes that can destroy the beams, which requires controlling the electron beam position at the micron scale. The existing conventional techniques for electron beam position monitoring are not applicable for sub-THz structures due to the space constraints. Here, on the other hand, if dipole modes amplitudes can be measured precisely at different planes, one can derive beam position relative to the central axis. For such a technique a reliable and cost-effective sensor capable of operating in high repletion rate regime is required. In this paper we review the experimental evaluation of a passive sensor candidate for such applications using RadiaBeam 4.5 MeV photoinjector.

Accelerator↗

Optimization of DARHT Axis 1 Injector Voltage

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injector electron beam energy. The technique for time resolved measurement of the electron beam energy using electron Permanent Magnet Spectrometer (ePMSpec) has been developed. The electron energy then is used to infer the voltage produced by the injector pulsed power. The injector pulsed power of DARHT I consists of a 1.5-MV, glycol-insulated Blumlein that is pulsecharged by a step-up transformer and switched by four, laser-triggered spark gaps. A series of increasing impedance transmission lines are used to transform the output voltage of the Blumlein to a maximum of 3.8MV at the diode. Figure 1a shows a graphic of the Axis-1 prime power tank, Blumlein and downstream transmission lines. The injector pulse power is designed to produce voltage on a velvet cathode located in the vacuum vessel. The specifications of the voltage-pulse flat-top over 60ns is +/-1%. A key element in the high-voltage circuit is the ethylene glycol Blumlein. The outer volume, adjacent to the laser triggered switches of the Blumlein, is a peaking capacitor. This is an independent volume that contains a mixture of ethylene glycol and water to make it an adjustable capacitor of 380 to 750 pF.

43 PARTICLE ACCELERATORS↗

Suppression of Helium Induced Cracking in Laser Repair Welding of Highly Irradiated Stainless Steels

Welding repair of irradiated nuclear reactor materials such as austenitic stainless steels used for the reactor internals has been challenging due to irradiation generated helium in the material matrix over an extended period of time. In this study, improved laser welding techniques, including the novel Auxiliary Beam Stress Improved (ABSI) technique that proactively manages the stresses during laser repair welding is investigated to substantially reduce or avoid the occurrence of intergranular helium-induced cracking (HeIC). Here, laser weld cladding, with and without ABSI technique, was applied to deposit weld metal on irradiated stainless steel (Type 304 L) blocks with various helium concentrations up to approximately 20 atomic parts per million (appm). Welded samples were cross-sectioned and analyzed using optical and electron microscopes. It was found that, with the improved laser welding techniques, no macroscopic (millimeter-sized) cracks were observed in any of the samples. Microscopic (less than 50 μm) cracks were present in the heat affected zone. Statistical analysis on the sample with the highest helium concentration (~20 appm) reveals that the ABSI technique could effectively reduce the size and amounts of microscopic cracks.

36 MATERIALS SCIENCE↗

Optimizing 4d Emittance Measurements Using the Pinhole Scan Technique

Accurate measurement of electron beam emittance is essential for optimizing high-brightness electron sources. The Pinhole Scan Technique measures the 4D phase space and hence the emittance by measuring the beam profile after clipping the beam using a pinhole followed by a drift section and then scanning the beam over the pinhole. This technique has been implemented in low energy (< 200 keV) beamlines at both Cornell University and Arizona State University. However, the technique poses several practical challenges. In this work, we analyze and address key issues affecting the 4D phase space and emittance measurements using this technique. We identify and investigate sources of inaccuracies like the pinhole aspect ratio, beam divergence, position-momentum correlations in the phase space, and the point-spread-function of the detector and suggest techniques to minimize them. Our findings offer a pathway to more accurate 4D phase space characterization in advanced electron beam systems.

42 ENGINEERING↗

Generation of Neutron Airy Beams

The Airy wave packet is a solution to the potential-free Schrödinger equation that exhibits remarkable properties such as self-acceleration, nondiffraction, and self-healing. Although Airy beams are now routinely realized with electromagnetic waves and electrons, the implementation with neutrons has remained elusive due to small transverse coherence lengths, low fluence rates, and the absence of neutron lenses. In this Letter, we overcome these challenges through a holographic approach and present the first experimental demonstration of neutron Airy beams. The presented techniques pave the way for fundamental physics studies with Airy beams of nonelementary particles, the development of novel neutron optics components, and the realization of neutron Airy-vortex beams. Published by the American Physical Society 2025

Sarenac, Dusan (ORCID:0000000185753367)↗

Atomically precise synthesis of oxides with hybrid molecular beam epitaxy

Advancements in synthesis science are revolutionizing the way we create atomically precise materials. Techniques like molecular beam epitaxy (MBE) have set the benchmark for addressing long-standing questions in materials science by leveraging improved control over the composition and structure of existing materials and enabling materials discovery. In this review, we discuss recent innovations in MBE that are redefining its capabilities, enabling the fabrication of ultra-pure, defect-engineered films and the stabilization of metastable phases that were previously unattainable. These advancements are unlocking new opportunities in electronic, magnetic, and quantum technologies, where the precise tuning of material properties is essential for advancing device functionality and performance.

complex oxides↗

Impact of fused silica debris shields and enhanced mitigation techniques on large-aperture beam-sampling optics for the National Ignition Facility

Here, we show that the large-scale routine use of the fused silica debris shield (FSDS) maintains the ∼100× reduction in damage initiation rate and 70% increase in the install lifetime of a new grating debris shield (GDS) observed during pilot operations. Furthermore, we show that the install lifetimes of recycled GDS optics are nearly tripled using additional mitigation strategies such as expanding mitigation processing to include all damage sites larger than 10 μm (LT10) rather than just larger than 50 μm (LT50) and FSDS. We note that there is still a 50% difference between new and recycled optic installation lifetimes. We show that recycled optics have a 3.5× higher apparent initiation rate than new optics when exposed to nominally identical laser conditions.

FSDS↗

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large-Angle Rocking Beam Electron Diffraction of Large Unit Cell Crystals Using Direct Electron Detector

We report a large-angle rocking beam electron diffraction (LARBED) technique for electron diffraction analysis. Diffraction patterns are recorded in a scanning transmission electron microscope (STEM) using a direct electron detector with large dynamical range and fast readout. We use a nanobeam for diffraction and perform the beam double rocking by synchronizing the detector with the STEM scan coils for the recording. Using this approach, large-angle convergent beam electron diffraction (LACBED) patterns of different reflections are obtained simultaneously. By using a nanobeam, instead of a focused beam, the LARBED technique can be applied to beam-sensitive crystals as well as crystals with large unit cells. Here, this paper describes the implementation of LARBED and evaluates the performance using silicon and gadolinium gallium garnet crystals as test samples. We demonstrate that our method provides an effective and robust way for recording LARBED patterns and paves the way for quantitative electron diffraction of large unit cell and beam-sensitive crystals.

4DSTEM↗