Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “batch sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Sludge Batch 11 Assembly: Tank 35

Savannah River Mission Completion Nuclear Safety and Engineering Integration (SRMC-E) has requested that Savannah River National Laboratory (SRNL) perform Tank 35 characterization analyses in support of Sludge Batch 11 (SB11) assembly. Two Tank 35 samples were delivered to SRNL and composited into a single sample in April 2023. The composite sample was analyzed for the following: density, weight percent solids, chemical composition, radionuclides, supernate corrosion control tests, and x-ray diffraction for burkeite, gibbsite, and boehmite.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fluid Induced Elemental and Mineralogy Alterations of Caney Shale

ABSTRACT: Studies were conducted on cores and rock cuttings recovered from two wells drilled in Caney shale in the Southern Oklahoma. Mineralogical compositions of these samples were obtained by X-Ray Diffraction (XRD) measurements using two methods of sample preparation: conventional powder (by crushing and grinding of rock fragments) and spray-drying of micronized rock powder method. Microstructure and microanalysis were acquired by Scanning Electron Microscopy/Energy Dispersive Spectroscopy (SEM/EDS). Batch experiments were then conducted using selected rock samples and fracturing fluid whilst deionized water was used as control sample for fluid/rock interaction. These were conducted at 95°C and ambient pressure for various time periods to assess the geochemical reactivity of the Caney shale. The rock samples were subsequently recovered from fluid, dried and analysis repeated using identical XRD and SEM/EDS measurements, following the same conditions. Preliminary experimental results show rock mineralogical compositions are predominantly quartz with relatively high clay content. The clay minerals are mainly illite. Carbonate content is less than 10% by weight for most samples, with other non-clay minerals pyrite, albite, dolomite, and some apatite. In general, sprayed samples showed more intense peaks and less full width at half maxima (FWHM) relative to conventional rock-powder samples. Post-experimental mineralogical changes were observed in samples with clay portions breaking down to amorphous entities. As expected, dissolution of carbonates (calcite and dolomite) was observed and newly detected dissolution of biogenic micro quartz resulted in formation of amorphous silica. 1.0 INTRODUCTION Formation of sedimentary rocks involves processes where rock sediments are emplaced with fluids starting interactions that persist over long periods. During the lithification process, sediments and fluids react and attain equilibrium state. This equilibrium is disturbed during drilling, completion, hydraulic fracturing and other operations that involve the introduction of engineered fluids into the subsurface. To return to equilibrium, dissolution and precipitation of minerals may occur. These reactions have implications on the petrophysical properties of the reservoir. Whiles dissolution and precipitation of minerals can enhance porosity and permeability, the reverse can also be true. For example, when acidic fluids are introduced into formations with high carbonate contents, carbonate minerals dissolve into solution thus increasing the porosity and permeability of the formation. In contrast, when alkaline fluids with pH above 11 are introduced into an illite-rich shale formation, the rock-fluid interaction leads to de-flocculation of illite platelets causing substantial increase in clay fines migration, consequently significant reduction in permeability (Salles et al., 2008).

Awejori, G.↗

Sequential polymer infusion into solid substrates (SPISS): Impact of processing on sorbent CO 2 adsorption properties

Solid sorbents made of small amine molecules and polyamines infused into mesoporous substrates are promising materials for CO 2 capture technologies. To date, their preparation is mainly based on wet infusion with focus on increasing amine content by varying the structure of the amine sorbent and designing solid substrates of various pore parameters. Less explored in the field are changes in processing to afford efficient CO 2 sorbents. In this study, branched poly(ethylenimine) (bPEI, M w = 800 Da) alone and blends with linear poly(propylenimine) (LPPI, M n = 6,700 Da) are infused into solid SBA-15 substrates by a method that varies the solution processing called sequential polymer infusion into solid substrates (SPISS). The reference 40 % bPEI-SBA-15 samples are split by two methods: split batch in dry suspension (SBD) and split batch in liquid suspension (SBL). Sequentially, alcoholic 10% of bPEI (non-blends) and 10% of LPPI (blends) solutions are introduced to afford the desired products. Under dry conditions, the resulting 50% bPEI-SBA-15 SBD & SBL sorbents display high CO 2 capacities up to 3.47 mmol CO 2 /g SiO 2 for simulated flue gas (10% CO 2 ) and 2.62 mmol CO 2 /g SiO 2 for direct air capture (DAC, 400 ppm CO 2 ). Under humid DAC conditions the CO 2 performance is further enhanced with an uptake of 4.62 mmol CO 2 /gSiO 2 and amine efficiency of 0.22 mmol CO 2 /mmol N. Subjected to extended temperature swing adsorption kinetic cycling (20 cycles), the SPISS samples display stable working capacities and retain over 70% (blends) and over 90% (non-blends) of their initial 12 h adsorption performance. LPPI is demonstrated to be an effective water sorption limiting agent using dynamic vapor sorption measurements. Solid state NMR techniques reveal important insights into the dynamics of the amine polymers confined into SBA-15 pores, as impacted by processing conditions. The results suggest that the conformation of the polymers is different depending on the processing method, displaying relatively tight (SBD) and loose (SBL) packing. Finally, the simple solution processing approaches presented here show that processing variations may guide the design of solid amine sorbents with desirable properties relevant for integration into CO 2 capture technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metabolic multireactor: Practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments

We present a system for carrying out small batch reactor oxygen consumption experiments on water and sediment samples for environmental questions. In general, it provides several advantages that can help researchers achieve impactful experiments at relatively low costs and high data quality. In particular, it allows for multiple reactors to be operated and their oxygen concentrations to be measured simultaneously, providing high throughput and high time-resolution data, which can be advantageous. Most existing literature on similar small batch-reactor metabolic studies is limited to either only a few samples, or only a few time points per sample, which can restrict the ability for researchers to learn from their experiments. The oxygen sensing system is based very directly on the work of Larsen, et al. [2011], and similar oxygen sensing technology is widely used in the literature. As such we do not delve deeply into the specifics of the fluorescent dye sensing mechanism. Instead, we focus on practical considerations. We describe the construction and operation of the calibration and experimental systems, and answer many of the questions likely to come up when other researchers choose to build and operate a similar system themselves (questions we ourselves had when we first built the system). In this way, we hope to provide an approachable and easy to use research article that can help other researchers construct and operate a similar system that can be tailored to ask their own research questions, with a minimum of confusion and missteps along the way.

3D printing↗

Mineralogy and reactive fluid chemistry evolution of hydraulically fractured Caney shale of Southern Oklahoma

Here, this study investigates geochemical rock-fluid interactions as a potential cause of rapid loss of permeability and productivity in hydraulically fractured shale reservoirs. It also interrogates the effects of these reactions in transforming depleted shale reservoirs into impermeable carbon storage units. The study employs batch reactor experiments where rock-powder samples are reacted with field fracturing fluid under reservoir temperature (95°C).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Experimental and Modeling Study of Geochemical Reactions of Simple Fracturing Fluids with Caney Shale

Interactions between rock minerals and hydraulic fluids directly impact the geochemical and geomechanical properties of shale formations. However, the mechanisms of geochemical reactions in shale unconventional reservoirs remain poorly understood. Here, to investigate the geochemical reactions between shale and hydraulic fracturing fluids, a series of batch reactor experiments were undertaken. Three rock samples with different mineralogical compositions and three fluid samples of different compositions (deionized water, deionized water + 2% potassium chloride (KCl), and deionized water + 0.5% choline chloride (C 5 H 14 ClNO) were used. Experiments were undertaken at reservoir temperature and atmospheric pressure. Elemental compositions of effluents after 1, 3, 7, 14, 28 days were analyzed using Inductively Couple Plasma Mass Spectrometry (ICP-MS). Medical Computed Tomography (CT) scan and X-ray Fluorescence (XRF) were conducted on the entire core run to help upscale results obtained from rock-fluid interaction experiments. Geochemical modeling using a reactive simulator, TOUGHREACT, was undertaken to corroborate experimental results. Results show that lower pH triggered high dissolution rates in the rock samples, especially the carbonate components. As pH increased, the rate of dissolution declined significantly, though for most cases dissolution still continued. Observed dissolved silica concentrations were much higher than the quartz solubility, suggesting that much of the silica originates from more soluble silica polymorphs and possibly desorption from clay mineral exchange sites. Concentration of most elemental species in solution increased but aluminium and magnesium concentrations declined rapidly following initial entry into solution. Geochemical modeling corroborated the conclusions regarding mineral dissolution and precipitation observed from experiments, notably; the dissolution of calcite and oxidation of pyrite in reacted shale samples, the likely presence of silica polymorphs such as opal, chalcedony or amorphous silica in these samples, and the reduction of Al and Mg concentrations in solution by precipitation of secondary aluminosilicate phases. The de-flocculation of clay minerals during reaction implies fines migration after hydraulic fracturing. This is detrimental to reservoir productivity as clay fines are displaces and lodged within the micro and nano-fractures created during fracturing. The immediate consumption of aluminium and magnesium also has implications on blockage of hydrocarbon pathways due to precipitation of new minerals in these locations.

04 OIL SHALES AND TAR SANDS↗

SSGUI v1.0

SSGUI is a web-based application that integrates the integrative genomics browser (IGV) with upstream alignment pipelines enabling rapid analysis of a batch of next-generation sequencing (NGS) samples. The input to SSGUI is an NGS file system directory that is organized by experiment and reference sequence. The output is an online dashboard containing various sequencing statistics for each sample and an integrated IGV plugin enabling rapid analysis of aligned NGS reads.

Kulawik, Mark↗

Technical note: Optimizing the in situ cosmogenic 36 Cl extraction and measurement workflow for geologic applications

Abstract. In situ cosmogenic 36Cl analysis by accelerator mass spectrometry (AMS) is routinely employed to date Quaternary surfaces and assess rates of landscape evolution. However, standard laboratory preparation procedures for 36Cl dating require the addition of large amounts of isotopically enriched chlorine spike solution; these solutions are expensive and increasingly difficult to acquire from commercial sources. In addition, the typical workflow for 36Cl dating involves measuring both 35Cl/37Cl and 36Cl/Cl concurrently on the high-energy (post-accelerator) end of the AMS system, but 35Cl/37Cl determinations using this technique can be complicated by isotope fractionation and system memory during measurement. The traditional workflow also does not provide 36Cl extraction laboratories with the data needed to calculate native Cl concentrations in advance of 36Cl/Cl measurements. In light of these concerns, we present an improved workflow for extracting and measuring chlorine in geologic materials. Our initial step is to characterize 35Cl/37Cl on sample aliquots of up to ∼1 g prepared in Ag(Cl, Br) matrices, which greatly reduces the amount of isotopically enriched spike solution required to measure native Cl content in each sample. To avoid potential issues with isotope fractionation through the accelerator, 35Cl/37Cl is measured on the low-energy, pre-accelerator end of the AMS line. Then, for 36Cl/Cl measurements, we extract Cl as AgCl or Ag(Cl, Br) in analytical batches with a consistent total Cl load across all samples; this step is intended to minimize source memory effects during 36Cl/Cl measurements and allows the preparation of AMS standards that are customized to match known Cl contents in the samples. To assess the efficacy of this extraction and measurement workflow, we compare chlorine isotope ratio measurements on seven geologic samples prepared using standard procedures and the updated workflow. Measurements of 35Cl/37Cl and 36Cl/Cl are consistent between the two workflows, and 35Cl/37Cl values measured using our methods have considerably higher precision than those measured following standard protocols. The chemical preparation and measurement workflow presented here (1) reduces the amount of isotopically enriched chlorine spike used per rock sample by up to 95 %; (2) identifies rocks with high native Cl concentrations, which may be lower priority for 36Cl surface exposure dating, at an early stage of analysis; and (3) allows laboratory users to maintain control over the total chlorine content within and across analytical batches. These methods can be incorporated into existing laboratory and AMS protocols for 36Cl analyses and will increase the accessibility of 36Cl dating for geologic applications.

58 GEOSCIENCES↗

Simple but tricky: Investigations of terephthalic acid purity obtained from mixed PET waste

In this study, we report for the first time, the basic depolymerization of mixed waste-polyethylene terephthalate (PET) by hydrolysis and subsequent terephthalic acid monomer recovery at high purity using benign reaction conditions. Several conditions were tested for depolymerization such as PET chips size, concentration of aqueous sodium hydroxide (20 or 30%), organic co-solvent (ethylene glycol or ethanol), temperature at which the reaction was run and duration of the heating. More importantly, several batches of PET were utilized as starting materials including a commercial PET, chopped PET obtained from clean bottles whose caps and labels were removed and the purity of the product from each condition was evaluated via nuclear magnetic resonance (1HNMR and 13CNMR), differential scanning calorimetry (DSC) and powder Xray diffraction (XRD). Unsurprisingly, the conversion of PET is dependent on the particle size varying from 100% conversion for fine powder to 73% conversion for (300 µm, mesh 6 – 20 or mesh 14-20). Ethanol appears to be more efficient as a co-solvent than ethylene glycol, with higher PET depolymerization conversions (94% versus 75-80%), shorter reaction times (2h versus 6h) and lower temperatures (80 °C versus 110 °C). The terephthalic acid (TPA) recovered appeared to have only subtle differences among the batches, most notably a pink color when the reaction was run in ethanol/base. The DSC of the compounds produced in ethylene glycol water appear to display a melting point (280-288 °C) while the samples prepared in ethanol as well as a commercial sample did not. Overall, the purity of the various TPA batches is comparable, and similar to commercial TPA, demonstrating the utility of the method to depolymerize realistic waste streams. The method is simple, demonstrated on multigram scale (15-30g) and allows for the complete removal of waste other than PET unaffected by alkaline conditions.

Cosimbescu, Lelia↗

Active Learning‐Driven Inkless Additive Nanomanufacturing for Printed Electronics

Inkless additive nanomanufacturing for printed electronics promises broad material and substrate versatility, yet the high-dimensional print parameter space makes tuning print parameters time-intensive. We present a Bayesian optimization study that constructs a digital twin from printed-silver data to benchmark surrogate models, acquisition functions, and batch sizes head-to-head to achieve user-specified target resistance. Tested surrogate models included Gaussian process, random forest, and Bayesian neural network surrogates with expected improvement and confidence bound acquisition functions. In total, we evaluate 48 unique model configurations alongside a random sampling baseline for comparison. For printed silver, the Bayesian neural network with a batch size of one achieved the lowest average cumulative regret, approximately four times more efficient on average than random sampling. To balance performance and substrate space, a random forest model with expected improvement and a batch size of four was chosen as the model for validation testing. Applying this chosen configuration to copper with an additional print parameter, the model achieved a resistance within 0.15 Ω of a 1 Ω target in fewer than 30 printed lines across five validation sets. Altogether, the workflow yields a tuned and validated model that efficiently guides experiments toward the target while simultaneously learning the parameter space.

Bevel, Colton [Auburn University, AL (United State↗

Decadal-Scale Hydrothermal Alteration of Basalt: Implications for Long-Term Reactivity in Subsurface Technologies

Global demands to secure critical mineral supply chains and managing water resources require innovative resource management strategies. Subsurface basalt reservoirs offer a dual-purpose application, where CO2 enhanced critical metal recovery can be coupled with water remediation strategies for the extraction of economically important and environmentally relevant elements. This study utilizes static batch experiments conducted on Columbia River Basalt Group samples to evaluate long-term fluid–rock interactions relevant to coupled subsurface applications. Samples were reacted under elevated temperature and pressure conditions, for 296 and 4,061 days, providing a unique dataset to assess geochemical evolution, element partitioning, and aqueous chemistry over decadal timescales. The alteration was dominated by silicate, aluminosilicate, and oxide phases. Progressive hydrothermal alteration increased the cation exchange capacity through the formation of secondary minerals (e.g. clays and zeolites), influencing solute retention, ion exchange behavior, and aqueous chemistry. Grain-scale and bulk analyses revealed selective cation release and retention patterns, establishing a mechanistic baseline for predicting element mobility. These geochemical constraints inform the prospective use of CO2-enhanced metal recovery for critical resources (e.g. Co, Ni, Mn, Mg, Ti, Fe) and associated water-quality impacts, providing a foundation for the design and management of engineered fluid–rock systems in basalt reservoirs.

Gibson, Marie N.↗

Establishing the Quality Assurance programme for the strip sensor production of the ATLAS tracker upgrade including irradiation with neutrons, photons and protons to HL-LHC fluences

The successful pre-production delivery of strip sensors for the new Inner Tracker (ITk) for the upgraded ATLAS detector at the High Luminosity LHC (HL-LHC) at CERN was completed and based on their performance full production has commenced. The overall delivery period is anticipated to last 4 years to complete the approximately 22000 sensors required for the ITk. For Quality Assurance (QA), a number of test structures designed by the collaboration, along with a large area diode and miniature version of the main sensor, are produced in every wafer by the foundry Hamamatsu Photonics K.K (HPK). As well as Quality Control (QC) checks on every main sensor, samples of the QA pieces from each delivery batch are tested both before and after irradiation with results after exposure to neutrons, gammas or protons to fluences and doses corresponding to those anticipated after operation at the HL-LHC to roughly 1.5 times the ultimate integrated luminosity of 4000 fb -1 . In this paper the procedures are presented and the studies carried out to establish that the seven ITk QA Strip Sensor irradiation and test sites meet all the requirements to support this very extensive programme throughout the strip sensor production phase for the ITk project.

47 OTHER INSTRUMENTATION↗

Sequencing and analysis of 131 SARS-CoV-2 isolates in previously sampled and unsampled regions of Jordan from 2020 to 2023

The Hashemite Kingdom of Jordan remains an understudied country for next generation sequencing analysis of SARS-CoV-2 genomes collected during the 2019 pandemic. Here we provide 131 additional reference genomes collected between 2020–2023 from SARS-CoV-2-positive patients across Jordan. Phylogenetic analysis supports existing pandemic narratives of changing clade dominance over time and adds genomes in novel Jordanian locations and timepoints to make Jordan SARS-CoV-2 databases more comprehensive. Samples from the less-sequenced cities of Ajloun, Jaresh, Karak, and Madaba identified previously unreported lineages while Amman, Irbid, and Zarqa have existing sequencing efforts bolstered. Despite many incomplete patient records and a relatively small sample size, we observe interesting symptom patterns that support existing global and Jordanian pandemic narratives. We note how in-country COVID-19 pandemic genomic studies showcase Jordan’s efforts to expand next generation sequencing capabilities, especially through the leveraging of EDGE COVID-19, a bioinformatics platform for performing rapid, batched analysis of SARS-CoV-2 sequencing that streamlines sample processing prepared from a network of hospital locations.

60 APPLIED LIFE SCIENCES↗

Design and Validation of a High-Throughput Reductive Catalytic Fractionation Method

Reductive catalytic fractionation (RCF) is a promising method to extract and depolymerize lignin from biomass, and bench-scale studies have enabled considerable progress in the past decade. RCF experiments are typically conducted in pressurized batch reactors with volumes ranging between 50 and 1000 mL, limiting the throughput of these experiments to one to six reactions per day for an individual researcher. Here, we report a high-throughput RCF (HTP-RCF) method in which batch RCF reactions are conducted in 1 mL wells machined directly into Hastelloy reactor plates. The plate reactors can seal high pressures produced by organic solvents by vertically stacking multiple reactor plates, leading to a compact and modular system capable of performing 240 reactions per experiment. Using this setup, we screened solvent mixtures and catalyst loadings for hydrogen-free RCF using 50 mg poplar and 0.5 mL reaction solvent. The system of 1:1 isopropanol/methanol showed optimal monomer yields and selectivity to 4-propyl substituted monomers, and validation reactions using 75 mL batch reactors produced identical monomer yields. To accommodate the low material loadings, we then developed a workup procedure for parallel filtration, washing, and drying of samples and a 1H nuclear magnetic resonance spectroscopy method to measure the RCF oil yield without performing liquid-liquid extraction. As a demonstration of this experimental pipeline, 50 unique switchgrass samples were screened in RCF reactions in the HTP-RCF system, revealing a wide range of monomer yields (21-36%), S/G ratios (0.41-0.93), and oil yields (40-75%). These results were successfully validated by repeating RCF reactions in 75 mL batch reactors for a subset of samples. We anticipate that this approach can be used to rapidly screen substrates, catalysts, and reaction conditions in high-pressure batch reactions with higher throughput than standard batch reactors.

BIOMASS FUELS,INORGANIC, ORGANIC, PHYSICAL, AND AN↗

M-Star® Software Test and Verification for Impeller Mixing in a Tank

Before a sample of the Slurry Mix Evaporator (SME) can be taken, the SME product sampling procedure requires that the agitator power be stable between 20 and 30 kW for at least one hour. The SME transfer to Melter Feed Tank (MFT) procedure also requires the SME agitator power be stabilized between 20 and 30 kW prior to transfer. These requirements are specified to ensure samples are homogeneous, as discussed in the Waste Form Qualification Report. During SME Batch 804, the agitator power dropped to 19 kW and struggled to achieve and maintain 20 kW. It was later discovered that the cause of the power drop was due to one of the bottom blades of the agitator breaking off. Both the sample and the transfer occurred without the power stabilizing between 20 and 30 kW. Therefore, the quality of SME Batch 804 is indeterminate, and homogeneity was questionable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

M-Star ® Modeling of SME Mixing with Three Impeller Blades

Before a sample of the Slurry Mix Evaporator (SME) can be taken, the SME product sampling procedure requires that the agitator power be stable between 20 and 30 kW for at least one hour. The SME transfer to Melter Feed Tank (MFT) procedure also requires the SME agitator power be stabilized between 20 and 30 kW prior to transfer. These requirements are specified to ensure samples are homogeneous, as discussed in the Waste Form Qualification Report. During SME Batch 804, the agitator power dropped to 19 kW and struggled to achieve and maintain 20 kW. It was later discovered that the cause of the power drop was due to one of the bottom blades of the agitator breaking off. Both the sample and the transfer occurred without the power stabilizing between 20 and 30 kW. Therefore, the quality of SME Batch 804 is indeterminate, and homogeneity was questionable. To evaluate mixing in the SME with a broken agitator containing only three blades (90 degrees apart with space for a missing blade) on the bottom impeller, the Savannah River National Laboratory (SRNL) was requested to perform computer simulations of impeller mixing in the SME using M-Star ® software. The simulations will be used to determine if SME Batch 804 was well mixed and satisfies homogeneity requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Active Learning-Based Streaming Pipeline for Reduced Data Training of Structure Finding Models in Neutron Diffractometry

Structure determination workloads in neutron diffractometry are computationally expensive and routinely require several hours to many days to determine the structure of a material from its neutron diffraction patterns. The potential for machine learning models trained on simulated neutron scattering patterns to significantly speed up these tasks have been reported recently. However, the amount of simulated data needed to train these models grows exponentially with the number of structural parameters to be predicted and poses a significant computational challenge. To overcome this challenge, we introduce a novel batch-mode active learning (AL) policy that uses uncertainty sampling to simulate training data drawn from a probability distribution that prefers labelled examples about which the model is least certain. We confirm its efficacy in training the same models with ∼ 75% less training data while improving the accuracy. We then discuss the design of an efficient stream-based training workflow that uses this AL policy and present a performance study on two heterogeneous platforms to demonstrate that, compared with a conventional training workflow, the streaming workflow delivers ∼ 20% shorter training time without any loss of accuracy.

Wang, Tianle [Brookhaven National Laboratory (BNL)↗

Optode performance data associated with: Metabolic Multireactor: practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments

This data package is associated with the publication “Metabolic Multireactor: practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments”, submitted to PlosONE (Kaufman et al. 2023; 10.1101/2023.03.28.534656).We carried out many testing and calibration experiments on a system of small oxygen consumption batch reactors designed for use with water and sediment samples for environmental questions. The oxygen sensing system is based very directly on the work of Larsen, et al. [2011], and similar oxygen sensing technology is widely used in the literature. Our primary focus was on practical considerations, such as temperature effects, lighting angle effects, sterilization, and other similar situations that a user may find useful. Most of the tests required comparing “base” calibration curves to “treatment” calibration curves to determine the extent to which the treatment impacted the reported measurements. This data package contains the performance and calibration data collected for that purpose.This dataset is comprised of one data folder containing (1) file-level metadata; (2) data dictionary; (3) readme; (4) diffusion test result files; (5) limit of detection test result files; (6) temperature impact files; (7) a main data file that contains test results for all other tests; and (8) an R script that uses Kolmogorov-Smirnov tests to determine whether treatment calibrations are significantly different from their respective base calibrations. All files are .csv, .txt, .Rmd, or .pdf.

54 ENVIRONMENTAL SCIENCES↗