Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “band-pass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Imaging Asteroid 4 Vesta Using the Framing Camera

The Framing Camera (FC) onboard the Dawn spacecraft serves a dual purpose. Next to its central role as a prime science instrument it is also used for the complex navigation of the ion drive spacecraft. The CCD detector with 1024 by 1024 pixels provides the stability for a multiyear mission and its high requirements of photometric accuracy over the wavelength band from 400 to 1000 nm covered by 7 band-pass filters. Vesta will be observed from 3 orbit stages with image scales of 227, 63, and 17 m/px, respectively. The mapping of Vesta s surface with medium resolution will be only completed during the exit phase when the north pole will be illuminated. A detailed pointing strategy will cover the surface at least twice at similar phase angles to provide stereo views for reconstruction of the topography. During approach the phase function of Vesta was determined over a range of angles not accessible from earth. This is the first step in deriving the photometric function of the surface. Combining the topography based on stereo tie points with the photometry in an iterative procedure will disclose details of the surface morphology at considerably smaller scales than the pixel scale. The 7 color filters are well positioned to provide information on the spectral slope in the visible, the depth of the strong pyroxene absorption band, and their variability over the surface. Cross calibration with the VIR spectrometer that extends into the near IR will provide detailed maps of Vesta s surface mineralogy and physical properties. Georeferencing all these observation will result in a coherent and unique data set. During Dawn s approach and capture FC has already demonstrated its performance. The strong variation observed by the Hubble Space Telescope can now be correlated with surface units and features. We will report on results obtained from images taken during survey mode covering the whole illuminated surface. Vesta is a planet-like differentiated body, but its surface gravity and escape velocity are comparable to those of other asteroids and hence much smaller than those of the inner planets or

Keller, H. Uwe↗

Ambient-Light-Canceling Camera Using Subtraction of Frames

The ambient-light-canceling camera (ALCC) is a proposed near-infrared electronic camera that would utilize a combination of (1) synchronized illumination during alternate frame periods and (2) subtraction of readouts from consecutive frames to obtain images without a background component of ambient light. The ALCC is intended especially for use in tracking the motion of an eye by the pupil center corneal reflection (PCCR) method. Eye tracking by the PCCR method has shown potential for application in human-computer interaction for people with and without disabilities, and for noninvasive monitoring, detection, and even diagnosis of physiological and neurological deficiencies. In the PCCR method, an eye is illuminated by near-infrared light from a lightemitting diode (LED). Some of the infrared light is reflected from the surface of the cornea. Some of the infrared light enters the eye through the pupil and is reflected from back of the eye out through the pupil a phenomenon commonly observed as the red-eye effect in flash photography. An electronic camera is oriented to image the user's eye. The output of the camera is digitized and processed by algorithms that locate the two reflections. Then from the locations of the centers of the two reflections, the direction of gaze is computed. As described thus far, the PCCR method is susceptible to errors caused by reflections of ambient light. Although a near-infrared band-pass optical filter can be used to discriminate against ambient light, some sources of ambient light have enough in-band power to compete with the LED signal. The mode of operation of the ALCC would complement or supplant spectral filtering by providing more nearly complete cancellation of the effect of ambient light. In the operation of the ALCC, a near-infrared LED would be pulsed on during one camera frame period and off during the next frame period. Thus, the scene would be illuminated by both the LED (signal) light and the ambient (background) light during one frame period, and would be illuminated with only ambient (background) light during the next frame period. The camera output would be digitized and sent to a computer, wherein the pixel values of the background-only frame would be subtracted from the pixel values of the signal-plus-background frame to obtain signal-only pixel values (see figure). To prevent artifacts of motion from entering the images, it would be necessary to acquire image data at a rate greater than the standard video rate of 30 frames per second. For this purpose, the ALCC would exploit a novel control technique developed at NASA s Jet Propulsion Laboratory for advanced charge-coupled-device (CCD) cameras. This technique provides for readout from a subwindow [region of interest (ROI)] within the image frame. Because the desired reflections from the eye would typically occupy a small fraction of the area within the image frame, the ROI capability would make it possible to acquire and subtract pixel values at rates of several hundred frames per second considerably greater than the standard video rate and sufficient to both (1) suppress motion artifacts and (2) track the motion of the eye between consecutive subtractive frame pairs.

Morookian, John Michael↗

Laser-Induced-Fluorescence Photogrammetry and Videogrammetry

An improved method of dot-projection photogrammetry and an extension of the method to encompass dot-projection videogrammetry overcome some deficiencies of dot-projection photogrammetry as previously practiced. The improved method makes it possible to perform dot-projection photogrammetry or videogrammetry on targets that have previously not been amenable to dot-projection photogrammetry because they do not scatter enough light. Such targets include ones that are transparent, specularly reflective, or dark. In standard dot-projection photogrammetry, multiple beams of white light are projected onto the surface of an object of interest (denoted the target) to form a known pattern of bright dots. The illuminated surface is imaged in one or more cameras oriented at a nonzero angle or angles with respect to a central axis of the illuminating beams. The locations of the dots in the image(s) contain stereoscopic information on the locations of the dots, and, hence, on the location, shape, and orientation of the illuminated surface of the target. The images are digitized and processed to extract this information. Hardware and software to implement standard dot-projection photogrammetry are commercially available. Success in dot-projection photogrammetry depends on achieving sufficient signal-to-noise ratios: that is, it depends on scattering of enough light by the target so that the dots as imaged in the camera(s) stand out clearly against the ambient-illumination component of the image of the target. In one technique used previously to increase the signal-to-noise ratio, the target is illuminated by intense, pulsed laser light and the light entering the camera(s) is band-pass filtered at the laser wavelength. Unfortunately, speckle caused by the coherence of the laser light engenders apparent movement in the projected dots, thereby giving rise to errors in the measurement of the centroids of the dots and corresponding errors in the computed shape and location of the surface of the target. The improved method is denoted laser-induced-fluorescence photogrammetry.

Danehy, Paul↗

Multilayer Dielectric Transmissive Optical Phase Modulator

A multilayer dielectric device has been fabricated as a prototype of a low-loss, low-distortion, transmissive optical phase modulator that would provide as much as a full cycle of phase change for all frequency components of a transmitted optical pulse over a frequency band as wide as 6.3 THz. Arrays of devices like this one could be an alternative to the arrays of mechanically actuated phase-control optics (adaptive optics) that have heretofore been used to correct for wave-front distortions in highly precise optical systems. Potential applications for these high-speed wave-front-control arrays of devices include agile beam steering, optical communications, optical metrology, optical tracking and targeting, directional optical ranging, and interferometric astronomy. The device concept is based on the same principle as that of band-pass interference filters made of multiple dielectric layers with fractional-wavelength thicknesses, except that here there is an additional focus on obtaining the desired spectral phase profile in addition to the device s spectral transmission profile. The device includes a GaAs substrate, on which there is deposited a stack of GaAs layers alternating with AlAs layers, amounting to a total of 91 layers. The design thicknesses of the layers range from 10 nm to greater than 1 micrometer. The number of layers and the thickness of each layer were chosen in a computational optimization process in which the wavelength dependences of the indices of refraction of GaAs and AlAs were taken into account as the design was iterated to maximize the transmission and minimize the group-velocity dispersion for a wavelength band wide enough to include all significant spectral components of the pulsed optical signal to be phase modulated.

Keys, Andrew Scott↗

Compact, Pneumatically Actuated Filter Shuttle

A compact, pneumatically actuated filter shuttle has been invented to enable alternating imaging of a wind-tunnel model in two different spectral bands characteristic of the pressure and temperature responses of a pressure and temperature-sensitive paint. This filter shuttle could also be used in other settings in which there are requirements for alternating imaging in two spectral bands. Pneumatic actuation was chosen because of a need to exert control remotely (that is, from outside the wind tunnel) and because the power leads that would be needed for electrical actuation would pose an unacceptable hazard in the wind tunnel. The entire shuttle mechanism and its housing can be built relatively inexpensively [<$500 (prices as of year 2000)] from off-the-shelf parts. The shuttle mechanism (see Figure 1) is contained in a housing that has dimensions of 4 by 6 by 2 in. (about 10 by 15 by 5 cm). Two 2-in. (=5-cm)-diameter standard scientific-grade band-pass filters are mounted on sliding panels in a dual-track frame. The mechanism is positioned and oriented so the panels slide sideways with respect to the optical axis of a charge-coupled-device camera used for viewing the wind-tunnel model. The mechanism includes a pneumatic actuator connected to a linkage. The linkage converts the actuator stroke to a scissor-like motion that places one filter in front of the camera and the other filter out of the way. Optoelectronic sensors detect tabs on the sliding panels for verification of the proper positioning of the filters.

Leighy, Bradley D.↗

Using Correlated Photons to Suppress Background Noise

A proposed method of suppressing the effect of background noise in an optical communication system would exploit the transmission and reception of correlated photons at the receiver. The method would not afford any advantage in a system in which performance is limited by shot noise. However, if the performance of the system is limited by background noise (e.g., sunlight in the case of a free-space optical communication system or incoherently scattered in-band photons in the case of a fiber-optic communication system), then the proposed method could offer an advantage: the proposed method would make it possible to achieve a signal-to-noise ratio (S/N) significantly greater than that of an otherwise equivalent background- noise-limited optical communication system based on the classical transmission and reception of uncorrelated photons. The figure schematically depicts a classical optical-communication system and a system according to the proposed method. In the classical system, a modulated laser beam is transmitted along an optical path to a receiver, the optics of which include a narrow-band-pass filter that suppresses some of the background noise. A photodetector in the receiver detects the laser-beam and background photons, most or all of which are uncorrelated. In the proposed system, correlated photons would be generated at the transmitter by making a modulated laser beam pass through a nonlinear parametric down-conversion crystal. The sum of frequencies of the correlated photons in each pair would equal the frequency of the incident photon from which they were generated. As in the classical system, the correlated photons would travel along an optical path to a receiver, where they would be band-pass filtered and detected. Unlike in the classical system, the photodetector in the receiver in this system would be one that intrinsically favors the detection of pairs of correlated photons over the detection of uncorrelated photons. Even though there would be no way of knowing the precise location and time of creation of a given pair of correlated signal photons in the nonlinear down-conversion crystal, the fact that the photons are necessarily created at the same time and place makes it possible to utilize conventional geometrical imaging optics to reunite the photons in coincidence in the receiving photodetector. Because most or all of the signal photons would be correlated while most or all of the noise photons would be uncorrelated, the S/N would be correspondingly enhanced in the photodetector output. An additional advantage to be gained by use of a correlated-photon detector is that it could be capable of recovering the signal even in the presence of background light so bright that a classical uncorrelated-photon detector would be saturated. A blocked-impurity-band (BIB) photodetector that preferentially detects pairs of correlated photons over uncorrelated ones and that operates at a quantum efficiency of 88 percent is commercially available. This detector must be cooled to the temperature of liquid helium to obtain the desired low-noise performance. It is planned to use this detector in a proof-of-principle demonstration. In addition, it may be possible to develop GaN-based photodetectors that could offer the desired low-noise performance at room temperature.

Jackson, Deborah↗

Turbulent Statistics from Time-Resolved PIV Measurements of a Jet Using Empirical Mode Decomposition

Empirical mode decomposition is an adaptive signal processing method that when applied to a broadband signal, such as that generated by turbulence, acts as a set of band-pass filters. This process was applied to data from time-resolved, particle image velocimetry measurements of subsonic jets prior to computing the second-order, two-point, space-time correlations from which turbulent phase velocities and length and time scales could be determined. The application of this method to large sets of simultaneous time histories is new. In this initial study, the results are relevant to acoustic analogy source models for jet noise prediction. The high frequency portion of the results could provide the turbulent values for subgrid scale models for noise that is missed in large-eddy simulations. The results are also used to infer that the cross-correlations between different components of the decomposed signals at two points in space, neglected in this initial study, are important.

Dahl, Milo D.↗

Turbulent Statistics from Time-Resolved PIV Measurements of a Jet Using Empirical Mode Decomposition

Empirical mode decomposition is an adaptive signal processing method that when applied to a broadband signal, such as that generated by turbulence, acts as a set of band-pass filters. This process was applied to data from time-resolved, particle image velocimetry measurements of subsonic jets prior to computing the second-order, two-point, space-time correlations from which turbulent phase velocities and length and time scales could be determined. The application of this method to large sets of simultaneous time histories is new. In this initial study, the results are relevant to acoustic analogy source models for jet noise prediction. The high frequency portion of the results could provide the turbulent values for subgrid scale models for noise that is missed in large-eddy simulations. The results are also used to infer that the cross-correlations between different components of the decomposed signals at two points in space, neglected in this initial study, are important.

Dahl, Milo D.↗

Turbulent Statistics From Time-Resolved PIV Measurements of a Jet Using Empirical Mode Decomposition

Empirical mode decomposition is an adaptive signal processing method that when applied to a broadband signal, such as that generated by turbulence, acts as a set of band-pass filters. This process was applied to data from time-resolved, particle image velocimetry measurements of subsonic jets prior to computing the second-order, two-point, space-time correlations from which turbulent phase velocities and length and time scales could be determined. The application of this method to large sets of simultaneous time histories is new. In this initial study, the results are relevant to acoustic analogy source models for jet noise prediction. The high frequency portion of the results could provide the turbulent values for subgrid scale models for noise that is missed in large-eddy simulations. The results are also used to infer that the cross-correlations between different components of the decomposed signals at two points in space, neglected in this initial study, are important.

Dahl, Milo D.↗

System and Method for Generating a Frequency Modulated Linear Laser Waveform

A system for generating a frequency modulated linear laser waveform includes a single frequency laser generator to produce a laser output signal. An electro-optical modulator modulates the frequency of the laser output signal to define a linear triangular waveform. An optical circulator passes the linear triangular waveform to a band-pass optical filter to filter out harmonic frequencies created in the waveform during modulation of the laser output signal, to define a pure filtered modulated waveform having a very narrow bandwidth. The optical circulator receives the pure filtered modulated laser waveform and transmits the modulated laser waveform to a target.

Pierrottet, Diego F.↗

Observing Tsunamis in the Ionosphere Using Ground Based GPS Measurements

Ground-based Global Positioning System (GPS) measurements of ionospheric Total Electron Content (TEC) show variations consistent with atmospheric internal gravity waves caused by ocean tsunamis following recent seismic events, including the Tohoku tsunami of March 11, 2011. We observe fluctuations correlated in time, space, and wave properties with this tsunami in TEC estimates processed using JPL's Global Ionospheric Mapping Software. These TEC estimates were band-pass filtered to remove ionospheric TEC variations with periods outside the typical range of internal gravity waves caused by tsunamis. Observable variations in TEC appear correlated with the Tohoku tsunami near the epicenter, at Hawaii, and near the west coast of North America. Disturbance magnitudes are 1-10% of the background TEC value. Observations near the epicenter are compared to estimates of expected tsunami-driven TEC variations produced by Embry Riddle Aeronautical University's Spectral Full Wave Model, an atmosphere-ionosphere coupling model, and found to be in good agreement. The potential exists to apply these detection techniques to real-time GPS TEC data, providing estimates of tsunami speed and amplitude that may be useful for future early warning systems.

total electron content (TEC)↗

Inter-Calibration and Concatenation of Climate Quality Infrared Cloudy Radiances from Multiple Instruments

A change in climate is not likely captured from any single instrument, since no single instrument can span decades of time. Therefore, to detect signals of global climate change, observations from many instruments on different platforms have to be concatenated. This requires careful and detailed consideration of instrumental differences such as footprint size, diurnal cycle of observations, and relative biases in the spectral brightness temperatures. Furthermore, a common basic assumption is that the data quality is independent of the observed scene and therefore can be determined using clear scene data. However, as will be demonstrated, this is not necessarily a valid assumption as the globe is mostly cloudy. In this study we highlight challenges in inter-calibration and concatenation of infrared radiances from multiple instruments by focusing on the analysis of deep convective or anvil clouds. TRMM/VIRS is potentially useful instrument to make correction for observational differences in the local time and foot print sizes, and thus could be applied retroactively to vintage instruments such as AIRS, IASI, IRIS, AVHRR, and HIRS. As the first step, in this study, we investigate and discuss to what extent AIRS and VIRS agree in capturing deep cloudy radiances at the same local time. The analysis also includes comparisons with one year observations from CrIS. It was found that the instruments show calibration differences of about 1K under deep cloudy scenes that can vary as a function of land type and local time of observation. The sensitivity of footprint size, view angle, and spectral band-pass differences cannot fully explain the observed differences. The observed discrepancies can be considered as a measure of the magnitude of issues which will arise in the comparison of legacy data with current data.

cloudy radiance↗

Observing Traveling Ionospheric Disturbances Caused by Tsunamis Using GPS TEC Measurements

Ground-based Global Positioning System (GPS) measurements of ionospheric Total Electron Content (TEC) show variations consistent with atmospheric internal gravity waves caused by ocean tsunamis following two recent seismic events: the American Samoa earthquake of September 29, 2009, and the Chile earthquake of February 27, 2010. Fluctuations in TEC correlated in time, space, and wave properties with these tsunamis were observed in TEC estimates processed using JPL's Global Ionospheric Mapping Software. These TEC estimates were band-pass filtered to remove ionospheric TEC variations with wavelengths and periods outside the typical range of internal gravity waves caused by tsunamis. Observable variations in TEC appear correlated with the tsunamis in certain locations, but not in others. Where variations are observed, the typical amplitude tends to be on the order of 1% of the background TEC value. Variations with amplitudes ~ 0.1 - 0.2 TECU are observable with periods and timing affiliated with the tsunami. These observations are compared to estimates of expected tsunami-driven TEC variations produced by Embry Riddle Aeronautical University's Spectral Full Wave Model, an atmosphere-ionosphere coupling model, and found to be in good agreement in some locations, though there are cases when the model predicts an observable tsunami-driven signature and none is observed. These TEC variations are not always seen when a tsunami is present, but in these two events the regions where a strong ocean tsunami was observed did coincide with clear TEC observations, while a lack of clear TEC observations coincided with smaller tsunami amplitudes. There exists the potential to apply these detection techniques to real-time GPS TEC data, providing estimates of tsunami speed and amplitude that may be useful for early warning systems.

Galvan, David A.↗

Ocular Vestibular Evoked Myogenic Potentials Using Head Striker Stimulation

Introduction: Over the last two decades, several studies have been published on the impact of long-duration (i.e., 22 days or longer) spaceflight on the central nervous system (CNS). In consideration of the health and performance of crewmembers in flight and post-flight, we are conducting a controlled prospective longitudinal study to investigate the effects of spaceflight on the extent, longevity and neural bases of sensorimotor, cognitive, and neural changes. Multiple studies have demonstrated the effects of spaceflight on the vestibular system. One of the supporting tests conducted in this protocol is the Vestibular Evoked Myogenic Potential (VEMP) test that provides a unilateral measure of otolith (saccule and utricle) function. A different approach was taken for ocular VEMP (oVEMP) testing using a head striker system (Wackym et al. 2012). The oVEMP is generally considered to be a measure of utricle function. The the otolithic input to the inferior oblique muscle is predominately from the utricular macula. Thus, quantitatively, oVEMP tests utricular function. Another practical extension of these relationships is that the oVEMP reflects the superior vestibular nerve function. Methods: Ground testing was administered on 16 control subjects and for 8 subjects over four repeated sessions spanning 70 days. The oVEMP was elicitied via a hand held striker by a vibrotactile pulse presented at the rate of 1 Hz for 24 seconds on the side of the head as subjects lay supine on a gurney. Subjects were directed to gaze approximately 25 degrees above straight ahead in semi-darkness. For the oVEMP electromyograms will be recorded with active bipolar electrodes (Delsys Inc., Boston, MA) on the infra-orbital ridge 1 cm below the eyelid with a reference electrode on the below the knee cap. The EMG potentials were amplified; band-pass filtered using a BagnoliTM Desktop EMG System (Delsys Inc., Boston, MA, USA). This EMG signal is sampled at 10 kHz and the data stimulus onset to 100 MS was averaged over 24 trial repetitions for the vibrotactile VEMP. The typical oVEMP EMG response is an excitatory potential with first peak occurring at 11-12 ms and second peak at 18 ms. This requires a total recording time of approximately 29 seconds per trial which includes 5 seconds of no vibrotactile stimulation at the beginning of the protocol. The primary dependent measures consist of the latency and peak-to-peak amplitude from the EMG signals, which will be normalized to EMG levels at the beginning of the protocol. Data were collected for 3 repeated trials with striker stimulation on both the left and right side of the head Results: The oVEMP p1 range was observed at 3-14 ms and n1 at 7-19 ms. The striker system provided a consistent and rapid method for oVEMP testing. Discussion: Crew testing is in progress to determine changes in results between pre and post flight.

De Dios, Y. E.↗

Improving Photometric Calibration of Meteor Video Camera Systems

We present the results of new calibration tests performed by the NASA Meteoroid Environment Oce (MEO) designed to help quantify and minimize systematic uncertainties in meteor photometry from video camera observations. These systematic uncertainties can be categorized by two main sources: an imperfect understanding of the linearity correction for the MEO's Watec 902H2 Ultimate video cameras and uncertainties in meteor magnitudes arising from transformations between the Watec camera's Sony EX-View HAD bandpass and the bandpasses used to determine reference star magnitudes. To address the rst point, we have measured the linearity response of the MEO's standard meteor video cameras using two independent laboratory tests on eight cameras. Our empirically determined linearity correction is critical for performing accurate photometry at low camera intensity levels. With regards to the second point, we have calculated synthetic magnitudes in the EX bandpass for reference stars. These synthetic magnitudes enable direct calculations of the meteor's photometric ux within the camera band-pass without requiring any assumptions of its spectral energy distribution. Systematic uncertainties in the synthetic magnitudes of individual reference stars are estimated at 0:20 mag, and are limited by the available spectral information in the reference catalogs. These two improvements allow for zero-points accurate to 0:05 􀀀 0:10 mag in both ltered and un ltered camera observations with no evidence for lingering systematics.

Ehlert, Steven↗

In-Flight Performance of the Soft X-Ray Spectrometer Detector System on ASTRO-H

The SXS instrument was launched aboard the Astro-H observatory on February 17, 2016. The SXS spectrometer is based on a high sensitivity x-ray calorimeter detector system that has been successfully deployed in many ground and sub-orbital spectrometers. The instrument was to provide essential diagnostics for nearly every class of x-ray emitting objects from the atmosphere of Jupiter to the outskirts of galaxy clusters, without degradation for spatially extended objects. The SXS detector system consisted of a 36-pixel cryogenic microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the detector system demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous band-pass from below 0.3 keV to above 12 keV with a timing precision better than 100 microsecond. In addition, a solid-state anti-coincidence detector was placed directly behind the detector array for background suppression. The detector error budget included the measured interference from the SXS cooling system and the spacecraft. Additional margin for on-orbit gain-stability, and on-orbit spacecraft interference were also included predicting an on-orbit performance that meets or exceeds the 7 eV FWHM at 6 keV requirement. The actual on-orbit spectral resolution was better than 5 eV FWHM at 6 keV, easily satisfying the instrument requirement. Here we discuss the actual on-orbit performance of the SXS detector system and compare this to performance in pre-flight testing and the on-orbit predictions. We will also discuss the on-orbit gain stability, additional on-orbit interference, and measurements of the on-orbit background.

X-ray astrophysics↗

System and Method for Generating a Frequency Modulated Linear Laser Waveform

A system for generating a frequency modulated linear laser waveform includes a single frequency laser generator to produce a laser output signal. An electro-optical modulator modulates the frequency of the laser output signal to define a linear triangular waveform. An optical circulator passes the linear triangular waveform to a band-pass optical filter to filter out harmonic frequencies created in the waveform during modulation of the laser output signal, to define a pure filtered modulated waveform having a very narrow bandwidth. The optical circulator receives the pure filtered modulated laser waveform and transmits the modulated laser waveform to a target.

Pierrottet, Diego F.↗

Enhanced Aluminum Reflecting and Solar-Blind Filter Coatings for the Far-Ultraviolet

The advancement of far-ultraviolet (FUV) coatings is essential to meet the specified throughput requirements of the Large UV/Optical/IR (LUVOIR) Surveyor Observatory which will cover wavelengths down to the 100 nm range. The biggest constraint in the optical thin film coating design is attenuation in the Lyman-Alpha Ultraviolet range of 100-130 nm in which conventionally deposited thin film materials used in this spectral region (e.g. aluminum [Al] protected with Magnesium fluoride [MgF2]) often have high absorption and scatter properties degrading the throughput in an optical system. We investigate the use of optimally deposited aluminum and aluminum tri-fluoride (AlF3) materials for reflecting and solar blind band-pass filter coatings for use in the FUV. Optical characterization of the deposited designs has been performed using UV spectrometry. The optical thin film design and optimal deposition conditions to produce superior reflectance and transmittance using Al and AlF3 are presented.

optical thin films↗