Upper limit for CH/plus/ toward Tau Scorpii

A Fabry-Perot interferometer was used to measure a 2-sigma upper limit of 0.39 mA for CH(plus) toward Tau Sco, a line of sight with a large amount of atomic hydrogen yet only a small amount of molecular hydrogen. The upper limit for the abundance of CH(plus) in a region where hydrogen is primarily atomic shows that no unexpectedly rapid CH(plus) formation processes are occurring and, conversely, that the CH(plus) destruction rate is not smaller than expected. It is argued that either CH(plus) is primarily formed in regions with large amounts of H2 or CH(plus) is formed at least as rapidly as the density-cubes in regions where hydrogen is mostly atomic.

Jura, M.

High spectral resolution Fabry-Perot interferometer measurements of Comet Halley at H-alpha and 6300 A

A 40.6-cm Newtonian telescope was interfaced to the Fabry-Perot interferometer at the Arecibo Observatory to make high-spectral-resolution measurements of Comet Halley emissions at 6562.72 A (H-alpha) and 6300.3 A (O I). The atomic hydrogen outflow velocity was found to be approximately 7.9 + or - 1.0 km/s. In general, the H-alpha spectra are highly structured, and indicative of a multiple component atomic hydrogen velocity distribution. For O (1D), implied production rates of 6.44 + or - 3.0 x 10 to the 28th/s and 5.66 + or - 2.7 x 10 to the 28th/s were found on March 15 and 17, respectively.

Kerr, R. B.

Molecular, atomic, and ionized gas in the NGC 6334 star forming region

NGC 6334 is a nearby (1.7 kpc) giant molecular cloud which contains at least 7 distinct sites of massive star formation. Using the Far-infrared Imaging Fabry-Perot Interferometer (FIFI) on the Kuiper Airborne Observatory we have imaged this region in the FIR fine structure lines of O(0) and C(+). The line intensity ratios are compared with the predicted line ratios from the PDR models of Wolfire, Tielens and Hollenbach (1990) (hereafter WTH) to determine the gas density and UV field strength. The (O I) 63 mu m/ 145 mu m intensity ratio is at least a factor of 10 lower than predicted. We suggest that self-absorption by cooler foreground material suppresses the (O I) 63 mu m line. We have also mapped CO J = 2 to 1 emission with the Caltech Submillimeter Observatory (CSO). In general, we find an anticorrelation of (C II) and CO emission. Particularly striking is a (C II) peak which is not associated with any CO, FIR or radio continuum source. Consequently, there is no local source of hard UV radiation. Either (1) the (C II) peak is illuminated by a cluster of embedded B stars, which radiate enough soft UV photons to ionize carbon, or (2) the (C II) peak is illuminated by a distant O star.

Kraemer, K. E.

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record

Laser-excitation technique for the measurement of absolute transition probabilities of weak atomic lines

A new technique is presented for the measurement of transition probabilities for weak allowed, intersystem, and forbidden lines. The method exploits the fact that oscillator strength is proportional to the number of stimulated absorptions and emissions produced by a narrow-band laser pulse of known energy which is in resonance with an atomic transition. The method is tested for a particular transition of Mg I with a known oscillator strength value and of appropriate magnitude. The number densities are measured using a Mach-Zehnder interferometer and the hook method for the lower level population and by measuring an absorption-equivalent width for the other. The apparatus consisted of a high-power tunable laser and a magnesium oven to produce excited Mg vapor, and a laser-plasma background continuum. The results are in good agreement with theoretical and other experimental data.

Kwong, H. S.

Shock compression of crystalline TeO 2 to the high-pressure fluid regime: Insights from ab initio molecular dynamics simulations

The shock response of fully-dense and porous crystalline tellurium dioxide (TeO 2 ⁠) to the high-pressure and high-temperature fluid regime was investigated within the framework of density functional theory with Mermin’s generalization to finite temperatures. The principal and porous shock Hugoniot curves were predicted from canonical ab initio molecular dynamics (AIMD) simulations, with the phase space sampled along isotherms up to 80 000 K, for densities ranging from ρ = 3 to 17 g/cm 3 . The polymorphs investigated are α-TeO 2 paratellurite (⁠P4 1 2 1 2), TeO 2 cotunnite (⁠Pnma⁠), and TeO 2 post-cotunnite (⁠P2 1 /m⁠). Based on the discontinuity found in the calculated U s – u p slope of TeO 2 post-cotunnite at a shock velocity of U s ≃ 8.35km/s and a particle velocity of u p ≃ 3.64 km/s, the shock melting temperature and pressure are predicted to be ≃ 6500 K and ≃ 170 GPa. Results from the AIMD simulations are in line with the static compression data of TeO 2 paratellurite and cotunnite, and with the recent shock Hugoniot data for single-crystal α- TeO 2 for pressures up to 85 GPa, obtained using the inclined-mirror method and the velocity interferometer system for any reflector combined with powder gun and two-stage light-gas gun.

74 ATOMIC AND MOLECULAR PHYSICS

Application of Fabry-perot Spectrometers for Measurement of Upper Atmosphere Temperatures and Winds

The mechanisms giving rise to certain airglow and auroral emissions and their height distribution are briefly surveyed. The basic principles of operation of scanning Fabry-Perot spectrometers are outlined in order to illustrate the calibration and use of such instruments to measure Doppler broadening and shift of atomic emission lines in the spectrum of the airglow and aurora and hence to infer atmospheric temperatures and wind velocities. Technical details of some specific instruments are given. Brief mention is made of the use of wide angle Michelson interferometers for the same application. Emphasis is given to the future importance of imaging Fabry-Perot spectrometers to permit the detailed mapping of temperature and wind velocity, especially in the auroral regions.

F Jacka

Atomic emission spectroscopy

The relationship between the Slater-Condon theory and the conditions within the atom as revealed by experimental data was investigated. The first spectrum of Si, Rb, Cl, Br, I, Ne, Ar, and Xe-136 and the second spectrum of As, Cu, and P were determined. Methods for assessing the phase stability of fringe counting interferometers and the design of an autoranging scanning system for digitizing the output of an infrared spectrometer and recording it on magnetic tape are described.

Andrew, K. H.

Preliminary Analysis of Images from the Thermospheric Temperature Image on Fast, Affordable, Science and Technology Satellite (FASTSAT)

The Thermospheric Temperature Imager (TTI) on Fast, Affordable, Science and Technology SATellite (FASTSAT) measures the upper atmospheric atomic oxygen emission at 135.6 nm and the molecular nitrogen LBH emission at 135.4 nm to determine the atmospheric O/N2 density ratio. Observations of variations in this thermospheric ratio correspond to electron density variations in the ionosphere. The TTI design makes use of a Fabry-Perot interferometer to measure Doppler widened atmospheric emissions to determine neutral atmospheric temperature from low Earth orbit. FASTSAT launched November 10, 2010 and TTI is currently observing geomagnetic signatures in the aurora and airglow. This work is supported by NASA.

Rodriquez, Marcello

Post sunset behavior of the 6300 A atomic oxygen airglow emission

A theoretical model of the 6300 A OI airglow emission was developed based on the assumptions that both the charged and neutral portions of the Earth's upper atmosphere are in steady state conditions of diffusive equilibrium. Intensities of 6300 A OI emission line were calculated using electron density true height profiles from a standard C-4 ionosonde and exospheric temperatures derived from Fabry-Perot interferometer measurements of the Doppler broadened 6300 A emission line shape as inputs to the model. Reaction rate coefficient values, production mechanism efficiencies, solar radiation fluxes, absorption cross sections, and models of the neutral atmosphere were varied parametrically to establish a set of acceptable inputs which will consistently predict 6300 A emission intensities that closely agree with intensities observed during the post-sunset twilight period by an airglow observatory consisting of a Fabry-Perot interferometer and a turret photometer. Emission intensities that can only result from the dissociative recombination of molecular oxygen ions were observed during the latter portion of the observational period. Theoretical calculations indicate that contamination of the 6300 A OI emission should be on the order of or less than 3 percent; however, these results are very sensitive to the wavelengths of the individual lines and their intensities relative to the 6300 A OI intensity. This combination of a model atmosphere, production mechanism efficiencies, and quenching coefficient values was used when the dissociative photoexcitation and direct impact excitation processes were contributing to the intensity to establish best estimates of solar radiation fluxes in the Schumann--Runge continuum and associated absorption cross sections. Results show that the Jacchia 1971 model of the upper atmosphere combined with the Ackerman recommended solar radiation fluxes and associated absorption cross sections produces theoretically calculated intensities that more closely agree with the observed intensities than all the other combinations.

Smith, R. E.

Coaxial injector spray characterization using water/air as simulants

Quantitative information about the atomization of injector sprays is required to improve the accuracy of computational models that predict the performance and stability of liquid propellant rocket engines. An experimental program is being conducted at NASA-Lewis to measure the drop size and velocity distributions in shear coaxial injector sprays. A phase/Doppler interferometer is used to obtain drop size data in water air shear coaxial injector sprays. Droplet sizes and axial component of droplet velocities are measured at different radii for various combinations of water flow rate, air flow rate, injector liquid jet diameter, injector annular gap, and liquid post recess. Sauter mean diameters measured in the spray center 51 mm downstream of the liquid post tip range from 28 to 68 microns, and mean axial drop velocities at the same location range from 37 to 120 m/s. The shear coaxial injector sprays show a high degree of symmetry; the mean drop size and velocity profiles vary with liquid flow rate, post recess, and distance from the injector face. The drop size data can be used to estimate liquid oxygen/hydrogen spray drop sizes by correcting property differences between water-air and liquid oxygen/hydrogen.

Zaller, Michelle M.

Measurements of the Michigan Airglow Observatory from 1971 to 1973 at Ester Dome Alaska

The Michigan Airglow Observatory (MAO) was located at Ester Dome Observatory, College, Alaska (latitude: 64 deg 53'N, longitude: 148 deg 03'W) since October, 1971. The MAO houses a 6-inch Fabry-Perot interferometer, a 2-channel monitoring photometer and a 4-channel tilting filter photometer. The Fabry-Perot interferometer was used extensively during the winter observing seasons of 1971-72 and 1972-73 to measure temperature and mass motions of the neutral atmosphere above approximately 90 kilometers altitude. Neutral wind data from the 1971-72 observing season as measured by observing the Doppler shift of the gamma 6300 A atomic oxygen emission line are presented.

Mcwatters, K. D.

Neutral winds in the polar thermosphere as measured from Dynamics Explorer

Possibilities for experimental investigations related to the study of the dynamics of the thermosphere have been markedly improved by the new instrumentation deployed on the Dynamics Explorer Satellite (DE). The Fabry-Perot interferometer (FPI) on DE measures altitude profiles of the meridional component of the neutral wind below the spacecraft by remotely sensing the Doppler shift of the thermospheric O(1D). The Wind and Temperature Spectrometer (WATS) measures the in situ zonal component of the neutral wind by measuring the angle of arrival of the beam of neutral atoms entering the aperture to a mass spectrometer. A description is provided of data handling procedures, and the first results obtained by combining the data sets from the two instruments are presented. Acquisition and determination of neutral wind vectors from the remote (FPI) and in-situ (WATS) measurements requires careful handling of the data to ensure that the two components relate to the same volume of space.

Killeen, T. L.

Development of a wide bandwidth heterodyne dispersion interferometer for electron density measurement of atmospheric pressure plasmas

One of the challenges of electron density measurements of an atmospheric pressure plasma (APP) with a laser interferometer is the significant and unwanted phase shift caused by changes in the neutral gas density. These unwanted phase shifts can be mitigated and plasma density measured using an interferometer architecture called a dispersion interferometer (DI). A DI is composed of two nonlinear orientation patterned GaAs crystals for frequency doubling and measures the phase shift induced by a plasma in the interference signal between two second-harmonic beams. Measurement of plasma dynamics or a short plasma pulse in less than a millisecond is enabled with heterodyne detection in a DI using an acousto-optic cell with a frequency of 40 MHz. This heterodyne DI (HDI) is targeted to measure APPs in an electron density range of 10 20 –10 24 m −3 . Finally, the HDI achieves a line-integrated density resolution of 2 × 10 15 m −2 (a phase resolution of 0.005°) with a time constant of 1 μs using ensemble averaging techniques.

atmospheric pressure plasma

Observations of the 2-micron unidentified lines in planetary nebulae

Medium-resolution spectra in the K-window have been obtained for 13 planetary nebulae and one compact H II region in order to study the behavior of the unidentified line at 2.287 microns. The wavelengths of this line and the unidentified 2.199-micron line have been measured in NGC 7027 at high spectral resolution using a Fabry-Perot interferometer. Based on the interferometric measurements and the lack of correlation of the 2.287-micron line with emission in H2 lines, the unidentified lines are not lines of molecular hydrogen. The 2.287-micron line is strongest in medium-high excitation nebulae, and is absent in nebulae of very low and very high excitation, implying that the ionization potential of the parent atom or ion is about 30-40 eV and that the ion itself has an ionization potential of perhaps 40-60 eV.

Geballe, T. R.

Can the Hypothesis 'Photon Interferes only with Itself' be Reconciled with Superposition of Light from Multiple Beams or Sources?

Any superposition effect as measured (SEM) by us is the summation of simultaneous stimulations experienced by a detector due to the presence of multiple copies of a detectee each carrying different values of the same parameter. We discus the cases with light beams carrying same frequency for both diffraction and multiple beam Fabry-Perot interferometer and also a case where the two superposed light beams carry different frequencies. Our key argument is that if light really consists of indivisible elementary particle, photon, then it cannot by itself create superposition effect since the state vector of an elementary particle cannot carry more than one values of any parameter at the same time. Fortunately, semiclassical model explains all light induced interactions using quantized atoms and classical EM wave packet. Classical physics, with its deeper commitment to Reality Ontology, was better prepared to nurture the emergence of Quantum Mechanics and still can provide guidance to explore nature deeper if we pay careful attention to successful classical formulations like Huygens-Fresnel diffraction integral.

Roychoudhuri, Chandrasekhar

Ground Based Program for the Physical Analysis of Macromolecular Crystal Growth

In a reported period in situ atomic force microscopy was utilized in our laboratory to study mechanisms of growth and kinetics of crystallization of ten protein and virus crystals. These included canavalin, thaumatin, apoferritin, lipase, catalase, t-RNA, lysozyme, xylanase, turnip yellow mosaic virus (TYMV) and satellite tobacco mosaic virus (STMV). We have also designed and constructed in our laboratory both in situ conventional two-beam Michelson and phase shift Mach-Zenhder interferometers. Computer software for the processing of the interferometric images was developed as well. Interferometric techniques were applied for studies of growth kinetics and transport phenomena in crystallization of several macromolecular crystals. As a result of this work we have published 21 papers and have given many presentations at international and national meetings. A list of these publications and conference presentations is attached.

Malkin, Alexander J.

Upper Thermosphere Winds and Temperatures in the Geomagnetic Polar Cap: Solar Cycle, Geomagnetic Activity, and Interplanetary Magnetic Field Dependencies

Ground-based Fabry-Perot interferometers located at Thule, Greenland (76.5 deg. N, 69.0 deg. W, lambda = 86 deg.) and at Sondre Stromfjord, Greenland (67.0 deg. N, 50.9 deg. W, lambda = 74 deg.) have monitored the upper thermospheric (approx. 240-km altitude) neutral wind and temperature over the northern hemisphere geomagnetic polar cap since 1983 and 1985, respectively. The thermospheric observations are obtained by determining the Doppler characteristics of the (OI) 15,867-K (630.0-nm) emission of atomic oxygen. The instruments operate on a routine, automatic, (mostly) untended basis during the winter observing seasons, with data coverage limited only by cloud cover and (occasional) instrument failures. This unique database of geomagnetic polar cap measurements now extends over the complete range of solar activity. We present an analysis of the measurements made between 1985 (near solar minimum) and 1991 (near solar maximum), as part of a long-term study of geomagnetic polar cap thermospheric climatology. The measurements from a total of 902 nights of observations are compared with the predictions of two semiempirical models: the Vector Spherical Harmonic (VSH) model of Killeen et al. (1987) and the Horizontal Wind Model (HWM) of Hedin et al. (1991). The results are also analyzed using calculations of thermospheric momentum forcing terms from the Thermosphere-ionosphere General Circulation Model TGCM) of the National Center for Atmospheric Research (NCAR). The experimental results show that upper thermospheric winds in the geomagnetic polar cap have a fundamental diurnal character, with typical wind speeds of about 200 m/s at solar minimum, rising to up to about 800 m/s at solar maximum, depending on geomagnetic activity level. These winds generally blow in the antisunward direction, but are interrupted by episodes of modified wind velocity and altered direction often associated with changes in the orientation of the Interplanetary Magnetic Field (IMF). The central polar cap (greater than approx. 80 magnetic latitude) antisunward wind speed is found to be a strong function of both solar and geomagnetic activity. The polar cap temperatures show variations in both solar and geomagnetic activity, with temperatures near 800 K for low K(sub p) and F(sub 10.7) and greater than about 2000 K for high K(sub p) and F(sub 10.7). The observed temperatures are significantly greater than those predicted by the mass spectrometer/incoherent scatter model for high activity conditions. Theoretical analysis based on the NCAR TIGCM indicates that the antisunward upper thermospheric winds, driven by upstream ion drag, basically 'coast' across the polar cap. The relatively small changes in wind velocity and direction within the polar cap are induced by a combination of forcing terms of commensurate magnitude, including the nonlinear advection term, the Coriolis term, and the pressure gradient force term. The polar cap thennospheric thermal balance is dominated by horizontal advection, and adiabatic and thermal conduction terms.

Killeen, T. L.