Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “assays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays

Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.

Biology↗

A Glycan Array-Based Assay for the Identification and Characterization of Plant Glycosyltransferases

Growing plants with modified cell wall compositions is a promising strategy to improve resistance to pathogens, increase biomass digestibility, and tune other important properties. In order to alter biomass architecture, a detailed knowledge of cell wall structure and biosynthesis is a prerequisite. We report here a glycan array-based assay for the high-throughput identification and characterization of plant cell wall biosynthetic glycosyltransferases (GTs). We demonstrate that different heterologously expressed galactosyl-, fucosyl-, and xylosyltransferases can transfer azido-functionalized sugar nucleotide donors to selected synthetic plant cell wall oligosaccharides on the array and that the transferred monosaccharides can be visualized “on chip” by a 1,3-dipolar cycloaddition reaction with an alkynyl-modified dye. The opportunity to simultaneously screen thousands of combinations of putative GTs, nucleotide sugar donors, and oligosaccharide acceptors will dramatically accelerate plant cell wall biosynthesis research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence-coupled micropipette aspiration assay to examine calcium mobilization caused by red blood cell mechanosensing

Abstract Mechanical stimuli such as tension, compression, and shear stress play critical roles in the physiological functions of red blood cells (RBCs) and their homeostasis, ATP release, and rheological properties. Intracellular calcium (Ca 2+ ) mobilization reflects RBC mechanosensing as they transverse the complex vasculature. Emerging studies have demonstrated the presence of mechanosensitive Ca 2+ permeable ion channels and their function has been implicated in the regulation of RBC volume and deformability. However, how these mechanoreceptors trigger Ca 2+ influx and subsequent cellular responses are still unclear. Here, we introduce a fluorescence-coupled micropipette aspiration assay to examine RBC mechanosensing at the single-cell level. To achieve a wide range of cell aspirations, we implemented and compared two negative pressure adjusting apparatuses: a homemade water manometer (− 2.94 to 0 mmH 2 O) and a pneumatic high-speed pressure clamp (− 25 to 0 mmHg). To visualize Ca 2+ influx, RBCs were pre-loaded with an intensiometric probe Cal-520 AM, then imaged under a confocal microscope with concurrent bright-field and fluorescent imaging at acquisition rates of 10 frames per second. Remarkably, we observed the related changes in intracellular Ca 2+ levels immediately after aspirating individual RBCs in a pressure-dependent manner. The RBC aspirated by the water manometer only displayed 1.1-fold increase in fluorescence intensity, whereas the RBC aspirated by the pneumatic clamp showed up to threefold increase. These results demonstrated the water manometer as a gentle tool for cell manipulation with minimal pre-activation, while the high-speed pneumatic clamp as a much stronger pressure actuator to examine cell mechanosensing directly. Together, this multimodal platform enables us to precisely control aspiration and membrane tension, and subsequently correlate this with intracellular calcium concentration dynamics in a robust and reproducible manner.

Wang, Haoqing↗

Identification of background limitations to ultra-sensitive $\mathrm{LSC}$ counting through $\mathrm{ICP}$-$\mathrm{MS}$ assay of $\mathrm{LSC}$ cocktails

We report the performance of LSC cocktails in ultra-sensitive applications was evaluated. Backgrounds from radioactive contaminations in commercially available and in-house developed liquid scintillation cocktails were measured and compared to the predicted background levels of the ultra-low background liquid scintillation counter. Through the ICP-MS assay of the cocktails and their constituents, potassium impurities in the surfactant component were identified as a significant source of background, potentially limiting the use of LSC counting in ultra-sensitive applications. This work lays the groundwork for future research towards ultrapure LSC cocktails for ultrasensitive LSC counting

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A high throughput assay to detect enzymatic polyethylene oxidation

Biological plastics deconstruction and upcycling have emerged as sustainable alternatives to traditional recycling technologies for plastics waste. The discovery and engineering of efficient thermostable poly(ethylene terephthalate) (PET) hydrolases have made biological PET recycling possible at scale; however, enzymes for non-PET plastics, which account for approximately 70% of all plastics produced, remain largely undiscovered. To accelerate the discovery of such enzymes, we develop a high-throughput screen to detect initial polymer oxidation, specifically that of the C-H bond to an aldehyde. We test 4-hydrazino-7-nitro-2,1,3-benxoxadiozole hydrazine (NBD-H), which reacts with generated aldehydes to form a fluorescent hydrazone on plasma oxidized low-density polyethylene (LDPE) films. Hydrazone generation correlated well with the area of aldehyde peaks as measured by Fourier Transform Infrared Spectroscopy (FTIR) (R2 = 0.92). Moreover, we demonstrate that the probe reliably identifies LDPE-active dye decolorizing peroxidases (DyPs) that generate aldehydes on LDPE films (1.7 – 3.0 fold change relative to background), serving as an effective screen as demonstrated by receiver operating characteristic area under the curve of 0.95. Furthermore, this assay offers an LDPE oxidation screening platform that can be readily parallelized and automated for accelerated discovery of enzymes involved in polyolefin deconstruction.

biocatalysis↗

Development and evaluation of an agar capture system (ACS) for high-throughput screening of insoluble particulate substrates with bacterial growth and enzyme activity assays

In this work, we describe a method for containing insoluble particulates for use as substrates in either bacterial growth or enzyme assays. This method was designed for high-throughput screening of environmental or engineered bacteria. Benchmarking this method with several model bacteria uncovered phenotypes not observable with the particulate substrates alone.

59 BASIC BIOLOGICAL SCIENCES↗

Sensitivity of the active neutron coincidence collar response during simulated and experimental fresh fuel assay

Verification of the fissile (and fertile) content in fresh nuclear fuel assemblies is conducted by the IAEA to enforce the Nuclear Non-Proliferation Treaty using the UNCL (Uranium Neutron Collar — Light Water Reactor Fuel). The UNCL uses an uncorrelated AmLi neutron source to interrogate the fuel, producing a signal of coincident fission neutrons (Doubles rate) used to assay 235 U content of the fuel. The cost of producing calibration assemblies and limited availability of diverse commercial assemblies at any one time historically restricted the ability to explore the full parameter space experimentally. Monte Carlo simulations can overcome this, but introduce additional sources of uncertainty. In this work, the sensitivity of simulations and measurements to various parameters is assessed for a reference 1616 PWR assembly of uniform 3.2% enrichment. Uncertainty contributions in this evaluation include: simulated AmLi neutron source spectrum, AmLi neutron emission rate, AmLi anisotropicity, high density polyethylene (HDPE) density, the precise position of the fuel assembly within the detector, and experimentally the statistical uncertainty. The overall total systematic uncertainty estimate for the simulation of the absolute/relative Doubles rates responses are estimated to be approximately 2.0%/1.5%, and for experimental measurements systematic uncertainty reduces to 1.1%. This analysis supports further work using the relative Doubles rates in place of measurements for updating and extending the UNCL analysis methodology as systematic uncertainty is reasonably small.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Depletion benchmark for a high-assay low-enriched uranium fuel experiment in the advanced test reactor

Reactor physics depletion benchmarks for high-assay low-enriched uranium (HALEU) fuel are limited in number. In particular, there is limited data for HALEU benchmarks for U-10Mo (uranium-10% molybdenum) plate fuel that is being developed for use in the United States’ high performance research reactors including the Advanced Test Reactor (ATR), Advanced Test Reactor Critical Facility (ATR-C), High Flux Isotope Reactor (HFIR), Massachusetts Institute of Technology Reactor (MITR), University of Missouri Research Reactor (MURR), National Bureau of Standards Reactor (NBSR). These six reactors currently operate with highly enriched uranium dispersed fuel in an aluminum matrix. In support of conversion to a HALEU fuel, qualification of U-10Mo formed into a monolithic foil is being performed. Fuel qualification involves irradiating fuel specimens in the ATR. The irradiation tests provide an opportunity to benchmark depletion capabilities of reactor physics codes in support of the ATR operation, as well as develop benchmarks that can be used by other institutions to benchmark other reactor physics codes. This paper documents the development of a benchmark model of the irradiation of the ATR Full-size plate In center flux trap Position 7 (AFIP-7) experiment using the depletion codes MC21 and Advanced Dimensional Depletion for Engineering of Reactors (ADDER).

Nielsen, Joseph W. [Idaho National Laboratory (INL↗

State-of-the-art γ-ray assay of 86 Y for medical imaging

An emerging direction in nuclear medicine is the coupling of a therapeutic isotope with an imaging isotope to form a so-called theranostic pair, which allows one to quantitatively track and image the delivery of the therapeutic isotope. 90 Y is used in several therapy applications and a convenient candidate imaging partner is the positron emitter 86 Y. A 27.6 MBq source of 86 Y was produced at the University of Wisconsin and assayed with the Gammasphere array at Argonne National Laboratory. Over 200 γ-ray transitions were identified, more than double that which was previously known. In conclusion, the positron emission probability inferred from the present level scheme leads to 27.9(12)%, an important (≈14%) reduction with respect to the previously recommended value.

59 ≤ A ≤ 89↗

Fluorescence Assay for Tolyporphins Amidst Abundant Chlorophyll in Crude Cyanobacterial Extracts

Abstract Tolyporphins are distinctive tetrapyrrole natural products found singularly in a filamentous cyanobacterial‐microbial holobiont (termed HT‐58‐2) from Micronesia. The absorption and fluorescence features of tolyporphins resemble those of chlorophyll a , complicating direct analysis of culture samples. Treatment of the crude (unfractionated) organic extract (CH 2 Cl 2 /2‐propanol, 1:1) of HT‐58‐2 cultures with NaBH 4 in methanol causes reduction of the peripheral ketone auxochromes, whereupon tolyporphins (predominantly 7,17‐dioxobacteriochlorins) exhibit a bathochromic shift ( λ abs ˜ 676 → ˜ 700 nm) and chlorophyll a (a 13 1 ‐oxochlorin) exhibits a hypsochromic shift ( λ abs 665 → 634 nm). Fluorescence excitation spectroscopy (at 368 and 491 nm with λ em 710 nm) enabled detection of reduced tolyporphins amidst abundant reduced chlorophyll a (1:19 ratio), a detection sensitivity >5 times that without reduction. The resulting assay combines simple sample preparation from non‐axenic cultures at microscale quantities (2 mL, 2 μ m ), absence of any fractionation procedures, and fluorescence detection. Tolyporphins were readily detected in cultures of HT‐58‐2 at reasonable growth periods in the absence of environmental stressors, which was not possible previously.

Nguyen, Kathy‐Uyen↗

Pooled PPIseq: Screening the SARS-CoV-2 and human interface with a scalable multiplexed protein-protein interaction assay platform

Protein-Protein Interactions (PPIs) are a key interface between virus and host, and these interactions are important to both viral reprogramming of the host and to host restriction of viral infection. In particular, viral-host PPI networks can be used to further our understanding of the molecular mechanisms of tissue specificity, host range, and virulence. At higher scales, viral-host PPI screening could also be used to screen for small-molecule antivirals that interfere with essential viral-host interactions, or to explore how the PPI networks between interacting viral and host genomes co-evolve. Current high-throughput PPI assays have screened entire viral-host PPI networks. However, these studies are time consuming, often require specialized equipment, and are difficult to further scale. Here, we develop methods that make larger-scale viral-host PPI screening more accessible. This approach combines the mDHFR split-tag reporter with the iSeq2 interaction-barcoding system to permit massively-multiplexed PPI quantification by simple pooled engineering of barcoded constructs, integration of these constructs into budding yeast, and fitness measurements by pooled cell competitions and barcode-sequencing. We applied this method to screen for PPIs between SARS-CoV-2 proteins and human proteins, screening in triplicate >180,000 ORF-ORF combinations represented by >1,000,000 barcoded lineages. Our results complement previous screens by identifying 74 putative PPIs, including interactions between ORF7A with the taste receptors TAS2R41 and TAS2R7, and between NSP4 with the transmembrane KDELR2 and KDELR3. We show that this PPI screening method is highly scalable, enabling larger studies aimed at generating a broad understanding of how viral effector proteins converge on cellular targets to effect replication.

60 APPLIED LIFE SCIENCES↗

Evaluation of Three RNA Extraction Kits with a 2019-nCoV Assay

The following characteristics of three RNA extraction kits (Norgen Biotek Total RNA Purification Kit, #17200; Bioneer AccuPrep Viral RNA Extraction Kit, #K-3033; and Promega Maxwell HT Viral TNA Kit, #AX2340) were evaluated: Limits of detection for quantitative synthetic RNA using the Centers for Disease Control and Prevention’s (CDC) 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel and the Applied Biosystems 7500 Fast Dx system; Limits of detection for positive clinical specimen using the Centers for Disease Control and Prevention’s (CDC) 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel and the Applied Biosystems 7500 Fast Dx system; Ability of the lysis buffers in each kit to inactivate the virus as measured by a cell-based infectivity assay.

60 APPLIED LIFE SCIENCES↗

Benchmark Gap Assessment for the Manufacturing of High-Assay Low-Enriched Uranium Fuels

This document develops basic critical conditions for spheres—moderated and unmoderated, as well as reflected and unreflected—in consideration of nuclear criticality safety of a potential fuel production facility producing high-assay low-enriched uranium (HALEU) fuel of several different types like tristructural-isotropic (TRISO), uranium metal and alloys, oxide and non-metallic forms. In addition to spherical arrangements, TRISO particle manufacturing process–specific equipment is modeled as it would be for the criticality safety analysis. The objective is to develop representative systems that can then be used for comparison with existing benchmarks. SCALE/TSUNAMI is used to assess the similarity index between these systems to assess validation gaps for possible fuel production applications of proposed advanced reactors. Several different fuel types were evaluated, including TRISO, uranium metal, uranium molybdenum, uranium zirconium, uranium dioxide, uranium nitride, uranium hydride, U-ZrH, and uranium chloride. This selection of fuel types covers a breadth of proposed reactor types, as well as intermediate steps in the production and fabrication of the fuel

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The MHC Associated Peptide Proteomics assay is a useful tool for the non-clinical assessment of immunogenicity

The propensity of therapeutic proteins to elicit an immune response, poses a significant challenge in clinical development and safety of the patients. Assessment of immunogenicity is crucial to predict potential adverse events and design safer biologics. In this study, we employed MHC Associated Peptide Proteomics (MAPPS) to comprehensively evaluate the immunogenic potential of re-engineered variants of immunogenic FVIIa analog (Vatreptacog Alfa). Our finding revealed the correlation between the protein sequence affinity for MHCII and the number of peptides identified in a MAPPS assay and this further correlates with the reduced T-cell responses. Moreover, MAPPS enable the identification of “relevant” T cell epitopes and may contribute to the development of biologics with lower immunogenic potential.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a colloidal gold immunochromatographic assay strip using monoclonal antibody for rapid detection of porcine deltacoronavirus

Porcine deltacoronavirus (PDCoV) cause diarrhea and dehydration in newborn piglets and has the potential for cross-species transmission. Rapid and early diagnosis is important for preventing and controlling infectious disease. In this study, two monoclonal antibodies (mAbs) were generated, which could specifically recognize recombinant PDCoV nucleocapsid (rPDCoV-N) protein. A colloidal gold immunochromatographic assay (GICA) strip using these mAbs was developed to detect PDCoV antigens within 15 min. Results showed that the detection limit of the GICA strip developed in this study was 10 3 TCID 50 /ml for the suspension of virus-infected cell culture and 0.125 μg/ml for rPDCoV-N protein, respectively. Besides, the GICA strip showed high specificity with no cross-reactivity with other porcine pathogenic viruses. Three hundred and twenty-five fecal samples were detected for PDCoV using the GICA strip and reverse transcription-quantitative real-time PCR (RT-qPCR). The coincidence rate of the GICA strip and RT-qPCR was 96.9%. The GICA strip had a diagnostic sensitivity of 88.9% and diagnostic specificity of 98.5%. The specific and efficient detection by the strip provides a convenient, rapid, easy to use and valuable diagnostic tool for PDCoV under laboratory and field conditions.

Wang, Wei↗