Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “anode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Advances in aluminum anodizing

White anodize is applied to aluminum alloy surfaces by specific surface preparation, anodizing, pigmentation, and sealing techniques. The development techniques resulted in alloys, which are used in space vehicles, with good reflectance values and excellent corrosive resistance.

Dale, K. H.↗

Anode heat transfer for a flowing argon plasma at elevated electron temperature.

Theoretical investigation of heat transfer from a preionized gaseous plasma flowing over an anode surface at an elevated electron temperature in the presence of an electric field normal to the surface. A laminar boundary layer is considered in which only the velocity profile is locally similar and fluid properties are assumed to change uniformly in the gas flow direction. Results obtained by an approximation method show that for moderate current densities, the velocity and temperature distributions are insensitive to current. In addition, the effect of elevated electron temperature is negligible on convective heat transfer, but is significant for the overall heat transfer due to the enthalpy transport by current. Total heat flux to the anode is obtained by evaluating the Nusselt number and adding terms due to the potential drop in the sheath and the surface work function.

Bose, T. K.↗

Electrochemical generation of oxygen. 1: The effects of anions and cations on hydrogen chemisorption and anodic oxide film formation on platinum electrode. 2: The effects of anions and cations on oxygen generation on platinum electrode

The effects were studied of anions and cations on hydrogen chemisorption and anodic oxide film formation on Pt by linear sweep voltammetry, and on oxygen generation on Pt by potentiostatic overpotential measurement. The hydrogen chemisorption and anodic oxide film formation regions are greatly influenced by anion adsorption. In acids, the strongly bound hydrogen occurs at more cathodic potential when chloride and sulfate are present. Sulfate affects the initial phase of oxide film formation by produced fine structure while chloride retards the oxide-film formation. In alkaline solutions, both strongly and weakly bound hydrogen are influenced by iodide, cyanide, and barium and calcium cations. These ions also influence the oxide film formation. Factors considered to explain these effects are discussed. The Tafel slope for oxygen generation was found to be independent on the oxide thickness and the presence of cations or anions. The catalytic activity indicated by the exchange current density was observed decreasing with increasing oxide layer thickness, only a minor dependence on the addition of certain cations and anions was found.

Huang, C. J.↗

Rechargeable battery which combats shape change of the zinc anode

A rechargeable cell or battery is provided in which shape change of the zinc anode is combatted by profiling the ionic conductivity of the paths between the electrodes. The ion flow is greatest at the edges of the electrodes and least at the centers, thereby reducing migration of the zinc ions from edges to the center of the anode. A number of embodiments are disclosed in which the strength and/or amount of electrolyte, and/or the number and/or size of the paths provided by the separator between the electrodes, are varied to provide the desired ionic conductivity profile.

Cohn, E. M.↗

Quadrant anode image sensor

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, about 10 microns, allows individual MCP channels to be distinguished.

Lampton, M.↗

Self-scanned anode array with a microchannel plate electron multiplier - The SSANACON

A photoelectron counting detector utilizing a 128-element linear self-scanned anode array to collect the output of a dual microchannel plate electron multiplier is described. The operation of the detector, its spatial resolution and detection efficiency, and radiation behavior are discussed. The low-noise detector was developed for the Mariner Jupiter/Saturn mission UV spectrometer, and offers a large dynamic range and count rate of 0.003 per anode-sec. It can measure simultaneously two spatially separated signals differing by more than six orders of magnitude in count rate.

Broadfoot, A. L.↗

Crossed grid anode and its image partitioning

Measurements on an imaging crossed grid anode following a pair of microchannel plates indicate fast charge propagation via wire-to-wire capacitances, suggesting a temporal resolution of 100 ns. A figure of merit for partitioned systems has been suggested that provides an estimate of the position uncertainty of photoelectrons in the image plane of an anode. Solutions for two-, three-, and four-amplifier position algorithms are given, and basic system requirements are discussed.

Knapp, G.↗

Design, fabrication, and evaluation of charge-coupled devices with aluminum-anodized-aluminum gates

A 4-phase, 49 1/2 bit CCD shift register was designed and fabricated using two levels of aluminum metallization with anodic Al2O3 insulation separating the layers. Test circuitry was also designed and constructed. A numerical analysis of an MOS-RC transmission line was made and results are given to characterize performance for various conductivities. The electrical design of the CCD included a low-noise dual-gate input and a balanced floating diffusion output circuit. Metallization was accomplished both by low voltage DC sputtering and thermal evaporation. The audization was according to published procedures using a buffered tartaric acid bath. Approximately 20 wafers were processed with 50 complete chips per wafer. All devices failed by shorting between the metal levels at some point. Experimental procedures eliminated temperature effects from sintering and drying, anodic oxide thickness, edge effects, photoresist stripping procedures, and metallization techniques as the primary causes of failure. It was believed from a study of SEM images that protuberances (hillocks) grow up from the first level metal through the oxide either causing a direct short or producing a weak, highly stressed insulation point which fails at low voltage. The cause of these hillocks is unknown; however, they have been observed to grow during temperature excursions to 470 C.

Gassaway, J. D.↗

Wedge-and-strip anodes for centroid-finding position-sensitive photon and particle detectors

The paper examines geometries employing position-dependent charge partitioning to obtain a two-dimensional position signal from each detected photon or particle. Requiring three or four anode electrodes and signal paths, images have little distortion and resolution is not limited by thermal noise. An analysis of the geometrical image nonlinearity between event centroid location and the charge partition ratios is presented. In addition, fabrication and testing of two wedge-and-strip anode systems are discussed. Images obtained with EUV radiation and microchannel plates verify the predicted performance, with further resolution improvements achieved by adopting low noise signal circuitry. Also discussed are the designs of practical X-ray, EUV, and charged particle image systems.

Martin, C.↗

Trimming epitaxial GaAs Schottky-diode parameters via anodic oxidation

Present day receivers operating at millimeter and sub-millimeter wavelengths most often rely, for their first mixers, on Schottky-barrier diodes formed on epitaxial GaAs. Crucial parameters for these diodes are breakdown voltage, series resistance, junction capacitance and forward conduction mechanism. Some of these are improved, others impaired, by change of epitaxy thickness. This paper describes experience with optimizing GaAs Schottky-diode parameters by anodic oxidation thinning of GaAs epitaxial layers. Monitoring of breakdown voltage of epitaxial GaAs in anodic oxidation solution provides indication of when thinning should be stopped in subjection to the breakdown voltage specification of diodes to be made from the material. Mixer and frequency-multiplier performance superior to any previously reported have been achieved by this technique.

Siegel, C. M.↗

Variable anodic thermal control coating

A process for providing a thermal control solar stable surface coating for aluminum surfaces adapted to be exposed to solar radiation wherein selected values within the range of 0.10 to 0.72 thermal emittance (epsilon sub tau) and 0.2 to 0.4 solar absorptance (alpha subs) are reproducibly obtained by anodizing the surface area in a chromic acid solution for a selected period of time. The rate voltage and time, along with the parameters of initial epsilon sub tau and alpha subs, temperature of the chromic acid solution, acid concentration of the solution and the material anodized determines the final values of epsilon/tau sub and alpha sub S. 9 Claims, 5 Drawing Figures.

Gilliland, C. S.↗

The development and test of ultra-large-format multi-anode microchannel array detector systems

The specific tasks that were accomplished with each of the key elements of the multi-anode microchannel array detector system are described. The modes of operation of position-sensitive electronic readout systems for use with high-gain microchannel plates are described and their performance characteristics compared and contrasted. Multi-anode microchannel array detector systems with formats as large as 256 x 1024 pixels are currently under evaluation. Preliminary performance data for sealed ultraviolet and visible-light detector tubes show that the detector systems have unique characteristics which make them complementary to photoconductive array detectors, such as CCDs, and superior to alternative pulse-counting detector systems employing high-gain MCPs.

Timothy, J. G.↗

Ring-cusp ion thruster with shell anode

An improved ion thruster for low specific impulse operation in the 1500 sec to 6000 sec range has a multicusp boundary field provided by high strength magnets on an iron anode shell which lengthens the paths of electrons from a hollow cathode assembly. A downstream anode pole piece in the form of an iron ring supports a ring of magnets to provide a more uniform beam profile. A cylindrical cathode magnet can be moved selectively in an axial direction along a feed tube to produce the desired magnetic field at the cathode tip.

Sovey, J. S.↗

Quick-Change Anode for Plating

Proposed fastener for attaching electroplating anode improves quality of plating and increases productivity. Notches in twist-lock fastener mates with projections on end of anode bar. Fastener made of titanium for compatibility with copper-plating solution. Also constructed in snap-on, snap-off configuration.

Beasley, J. L.↗

Imaging by time-tagging photons with the multi-anode microchannel array detector system

The capability and initial use of the Multi-Anode Microchannel Array (MAMA) detector in the time-tag mode is reported. The detector hardware currently in use consists of a visible-light detector tube with a semitransparent photocathode proximity-focused to a high-gain curved-channel microchannel plate MCP. The photoevents are detected by a (256 x 1024)-pixel coincidence-anode array with pixel dimensions of 25 x 25 microns connected to charge-sensitive amplifiers and event-detection circuitry. In the time-lag mode, the detector delivers the pixel address and the time of arrival for each detected photon to an accuracy of 10 microns. The maximum count rate is limited by the speed of data-acquisition hardware. The MAMA detector in the time-lag mode is currently being evaluated in programs of astrometry and speckle imaging.

Timothy, J. G.↗

Sodium hydroxide anodization of Ti-Al-4V adherends

The use of sodium hydroxide anodization (SHA) for Ti-6Al-4V adherends is examined. The SHA surface is evaluated using SEM, X-ray photoelectron spectroscopy, and Auger electron spectroscopy. The SHA procedures of Kennedy et al. (1983) were employed in this experiment. The photomicrographs of the SHA (sandblasted) and PSHA (sandblasted and pickled) oxide surface reveal that the two surfaces differ. The PSHA is patchy and similar to a chromic acid anodization surface and the porosity of the PSHA is more uniform than the SHA surface. The compositions of the surfaces are studied. It is noted that SHA is an effective pretreatment for Ti-6Al-4V adherends.

Filbey, Jennifer A.↗

Decoding techniques for fine-fine geometry multi-anode microchannel arrays

The Multi-Anode Microchannel Array (MAMA) is a photon-counting detector which decodes the position of an event through coincidence discrimination. The decoding algorithm which associates a given event with the appropriate pixel is determined by the geometry of the array. The decoding process can be divided into two tasks: anode encoding and pixel decoding. Techniques for performing both tasks are described and contrasted in light of application requirements. Decode times of 75 nanoseconds have been achieved, and considerably faster decoders are possible given new architectures and technologies.

Kasle, David B.↗