Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “angular resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High Resolution Imaging of Circumstellar Disks at Millimeter Wavelengths

We update progress on our research program to use high angular resolution imaging of thermal dust continuum emission at millimeter and submillimeter wavelengths to probe the structure of protoplanetary disks and debris disks around nearby stars. Observations at these wavelengths are advantageous because the dust emission is generally optically thin and directly proportional to mass, contrast with stellar photospheres is not problematic, and the wavelength dependence provides information on an important regime of grain sizes. We employ several facilities for state-of-the-art high resolution observations, including the Very Large Array (VLA), the Australia Telescope Compact Array (ATCA), the Plateau de Bure Interferometer (PdBI) of the Institut de RadioAstronomie Millimetrique, the Submillimeter Array (SMA) of the Smithsonian Astrophysical Observatory, and the Caltech Submillimeter Observatory (CSO). Many recent highlights of our program were presented in an invited review on High Angular Resolution Studies of Disks- the Millimetre at IAU Symposium 221, Star Formation at High Angular Resolution, in July 2003.

Wilner, David J.↗

X-Ray Diffractive Optics

X-ray optics were fabricated with the capability of imaging solar x-ray sources with better than 0.1 arcsecond angular resolution, over an order of magnitude finer than is currently possible. Such images would provide a new window into the little-understood energy release and particle acceleration regions in solar flares. They constitute one of the most promising ways to probe these regions in the solar atmosphere with the sensitivity and angular resolution needed to better understand the physical processes involved. A circular slit structure with widths as fine as 0.85 micron etched in a silicon wafer 8 microns thick forms a phase zone plate version of a Fresnel lens capable of focusing approx. =.6 keV x-rays. The focal length of the 3-cm diameter lenses is 100 microns, and the angular resolution capability is better than 0.1 arcsecond. Such phase zone plates were fabricated in Goddard fs Detector Development Lab. (DDL) and tested at the Goddard 600-microns x-ray test facility. The test data verified that the desired angular resolution and throughput efficiency were achieved.

Dennis, Brian↗

Next Generation X-Ray Optics: High-Resolution, Light-Weight, and Low-Cost

X-ray telescopes are essential to the future of x-ray astronomy. This paper describes a comprehensive program to advance the technology for x-ray telescopes well beyond the state of the art represented by the three currently operating missions: Chandra, XMM-Newton , and Suzaku . This program will address the three key issues in making an x-ray telescope: (I) angular resolution, (2) effective area per unit mass, and (3) cost per unit effective area. The objectives of this technology program are (1) in the near term, to enable Explorer-class x-ray missions and an IXO type mission, and (2) in the long term, to enable a flagship x-ray mission with sub-arcsecond angular resolution and multi-square-meter effective area, at an affordable cost. We pursue two approaches concurrently, emphasizing the first approach in the near term (2-5 years) and the second in the long term (4-10 years). The first approach is precision slumping of borosilicate glass sheets. By design and choice at the outset, this technique makes lightweight and low-cost mirrors. The development program will continue to improve angular resolution, to enable the production of 5-arcsecond x-ray telescopes, to support Explorer-class missions and one or more missions to supersede the original IXO mission. The second approach is precision polishing and light-weighting of single-crystal silicon mirrors. This approach benefits from two recent commercial developments: (1) the inexpensive and abundant availability of large blocks of mono crystalline silicon, and (2) revolutionary advances in deterministic, precision polishing of mirrors. By design and choice at the outset, this technique is capable of producing lightweight mirrors with sub-arcsecond angular resolution. The development program will increase the efficiency and reduce the cost of the polishing and the lightweighting processes, to enable the production of lightweight sub-arcsecond x-ray telescopes. Concurrent with the fabrication of lightweight mirror segments is the continued development and perfection of alignment and integration techniques, for incorporating individual mirror segments into a precision mirror assembly. Recently, we have been developing a technique called edge-bonding, which has achieved an accuracy to enable 10- arcsecond x-ray telescopes. Currently, we are investigating and improving the long-term alignment stability of so-bonded mirrors. Next, we shall refine this process to enable 5-arsecond x-ray telescopes. This technology development program includes all elements to demonstrate progress toward TRL-6: metrology; x-ray performance tests; coupled structural, thermal, and optical performance analysis, and environmental testing.

Zhang, William W.↗

Next Generation X-Ray Optics: High-Resolution, Light-Weight, and Low-Cost

X-ray telescopes are essential to the future of x-ray astronomy. In this talk I will describe a comprehensive program to advance the technology for x-ray telescopes well beyond the state of the art represented by the three currently operating missions: Chandra, XMM-Newton, and Suzaku. This program will address the three key issues in making an x-ray telescope: (1) angular resolution, (2) effective area per unit mass, and (3) cost per unit effective area. The objectives of this technology program are (1) in the near term, to enable Explorer-class x-ray missions and an IXO-type mission, and (2) in the long term, to enable a flagship x-ray mission with sub-arcsecond angular resolution and multi-square-meter effective area, at an affordable cost. We pursue two approaches concurrently, emphasizing the first approach in the near term (2-5 years) and the second in the long term (4-10 years). The first approach is precision slumping of borosilicate glass sheets. By design and choice at the outset, this technique makes lightweight and low-cost mirrors. The development program will continue to improve angular resolution, to enable the production of 5-arcsecond x-ray telescopes, to support Explorer-class missions and one or more missions to supersede the original IXO mission. The second approach is precision polishing and light-weighting of single-crystal silicon mirrors. This approach benefits from two recent commercial developments: (1) the inexpensive and abundant availability of large blocks of monocrystalline silicon, and (2) revolutionary advances in deterministic, precision polishing of mirrors. By design and choice at the outset, this technique is capable of producing lightweight mirrors with sub-arcsecond angular resolution. The development program will increase the efficiency and reduce the cost of the polishing and the light-weighting processes, to enable the production of lightweight sub-arcsecond x-ray telescopes. Concurrent with the fabrication of lightweight mirror segments is the continued development and perfection of alignment and integration techniques, for incorporating individual mirror segments into a precision mirror assembly. Recently, we have been developing a technique called edge-bonding, which has achieved an accuracy to enable 10-arcsecond x-ray telescopes. Currently, we are investigating and improving the long-term alignment stability of so-bonded mirrors. Next, we shall refine this process to enable 5-arsecond x-ray telescopes. This technology development program includes all elements to demonstrate progress toward TRL-6: metrology; x-ray performance tests; coupled structural, thermal, and optical performance analysis, and environmental testing.

Zhang, William W.↗

Simulated cosmic microwave background maps at 0.5 deg resolution: Basic results

We have simulated full-sky maps of the cosmic microwave background (CMB) anisotropy expected from cold dark matter (CDM) models at 0.5 deg and 1.0 deg angular resolution. Statistical properties of the maps are presented as a function of sky coverage, angular resolution, and instrument noise, and the implications of these results for observability of the Doppler peak are discussed. The rms fluctuations in a map are not a particularly robust probe of the existence of a Doppler peak; however, a full correlation analysis can provide reasonable sensitivity. We find that sensitivity to the Doppler peak depends primarily on the fraction of sky covered, and only secondarily on the angular resolution and noise level. Color plates of the simulated maps are presented to illustrate the anisotropies.

Hinshaw, G.↗

MegaMIR: The Megapixel Mid-Infrared Instrument for the Large Binocular Telescope Interferometer

The Megapixel Mid-infrared Instrument (MegaMIR) is a proposed Fizeau-mode camera for the Large Binocular Telescope operating at wavelengths between 5 and 28 micrometers. The camera will be used in conjunction with the Large Binocular Telescope Interferometer (LBTI), a cryogenic optical system that combines the beams from twin 8.4-m telescopes in a phase coherent manner. Unlike other interferometric systems, the co-mounted telescopes on the LBT satisfy the sine condition, providing diffraction-limited resolution over the 40" field of view of the camera. With a 22.8-m baseline, MegaMIR will yield 0.1" angular resolution, making it the highest resolution wide field imager in the thermal infrared for at least the next decade. MegaMIR will utilize a newly developed 1024 x 1024 pixel Si:As detector array that has been optimized for use at high backgrounds. This new detector is a derivative of the Wide-field Infrared Survey Explorer (WISE) low-background detector. The combination of high angular resolution and wide field imaging will be a unique scientific capability for astronomy. Key benefits will be realized in planetary science, galactic, and extra-galactic astronomy. High angular resolution is essential to disentangle highly complex sources, particularly in star formation regions and external galaxies, and MegaMIR provides this performance over a full field of view. Because of the great impact being made by space observatories like the Spitzer Space Telescope, the number of available targets for study has greatly increased in recent years, and MegaMIR will allow efficient follow up science.

ultraluminous galaxies↗

Absolute differential cross sections for electron capture and loss by kilo-electron-volt hydrogen atoms

This paper reports measurements of absolute differential cross sections for electron capture and loss for fast hydrogen atoms incident on H2, N2, O2, Ar, and He. Cross sections have been determined in the 2.0- to 5.0-keV energy range over the laboratory angular range 0.02-2 deg, with an angular, resolution of 0.02 deg. The high angular resolution allows observation of the structure at small angles in some of the cross sections. Comparison of the present results with those of other authors generally shows very good agreement.

Smith, G. J.↗

Adaptive Optics Imaging of Solar System Objects

Most solar system objects have never been observed at wavelengths longer than the R band with an angular resolution better than 1". The Hubble Space Telescope itself has only recently been equipped to observe in the infrared. However, because of its small diameter, the angular resolution is lower than that one can now achieved from the ground with adaptive optics, and time allocated to planetary science is limited. We have successfully used adaptive optics on a 4-m class telescope to obtain 0.1" resolution images of solar system objects in the far red and near infrared (0.7-2.5 microns), aE wavelengths which best discl"lmlnate their spectral signatures. Our efforts have been put into areas of research for which high angular resolution is essential.

Roddier, Francois↗

Adaptive Optics Imaging of Solar System Objects

Most solar system objects have never been observed at wavelengths longer than the R band with an angular resolution better than 1 sec. The Hubble Space Telescope itself has only recently been equipped to observe in the infrared. However, because of its small diameter, the angular resolution is lower than that one can now achieved from the ground with adaptive optics, and time allocated to planetary science is limited. We have been using adaptive optics (AO) on a 4-m class telescope to obtain 0.1 sec resolution images solar system objects at far red and near infrared wavelengths (0.7-2.5 micron) which best discriminate their spectral signatures. Our efforts has been put into areas of research for which high angular resolution is essential, such as the mapping of Titan and of large asteroids, the dynamics and composition of Neptune stratospheric clouds, the infrared photometry of Pluto, Charon, and close satellites previously undetected from the ground.

Roddier, Francois↗

Improved optics for laser light scattering

Laser light scattering experiments contemplated for use in a microgravity environment must conform to a number of operational constraints which do not apply on Earth. In particular, the use of index matching fluid to control flare is unacceptable. Work to eliminate index matching fluids by the use of high spatial resolution receiving optics is described. By increasing on-axis spatial resolution flare from the sample cell walls (both the cell sample and cell air interfaces) can be effectively prevented from reaching the photodetector. In general, improving the on-axis discrimination degrades the angular resolution of a receiving optical train. Several different possible configurations of receiving optics are compared for their spatial resolution and angular resolution. For cylinder symmetric optics, the dual lens, fourier transform pair, receiving train with a center mask located between the lenses gives the best on-axis spatial resolution.

Cheung, H. Michael↗

The Advanced Energetic Pair Telescope (AdEPT}: A Future Medium-Energy Gamma-Ray Balloon (and Explorer?) Mission

Gamma-ray astrophysics probes the highest energy, exotic phenomena in astrophysics. In the medium-energy regime, 0.1-200 MeV, many astrophysical objects exhibit unique and transitory behavior such as the transition from electron dominated to hadron dominated processes, spectral breaks, bursts, and flares. Medium-energy gamma-ray imaging however, continues to be a major challenge particularly because of high background, low effective area, and low source intensities. The sensitivity and angular resolution required to address these challenges requires a leap in technology. The Advance Energetic Pair Telescope (AdEPT) being developed at GSFC is designed to image gamma rays above 5 MeV via pair production with angular resolution of 1-10 deg. In addition AdEPT will, for the first time, provide high polarization sensitivity in this energy range. This performance is achieved by reducing the effective area in favor of enhanced angular resolution through the use of a low-density gaseous conversion medium. AdEPT is based on the Three-Dimensional Track Imager (3-DTI) technology that combines a large volume Negative Ion Time Projection Chamber (NITPC) with 2-D Micro-Well Detector (MWD) readout. I will review the major science topics addressable with medium-energy gamma-rays and discuss the current status of the AdEPT technology, a proposed balloon instrument, and the design of a future satellite mission.

Hunter, Stanley D.↗

On the Nature of the First Galaxies Selected at 350 Micrometers

We present constraints on the nature of the first galaxies selected at 350 micrometers. The sample includes galaxies discovered in the deepest blank-field survey at 350 micrometers (in the Bo6tes Deep Field) and also later serendipitous detections in the Lockman Hole. In determining multiwavelength identifications, the 350 lam position and map resolution of the second generation Submillimeter High Angular Resolution Camera are critical, especially in the cases where multiple radio sources exist and the 24 micrometer counterparts are unresolved. Spectral energy distribution templates are fitted to identified counterparts, and the sample is found to comprise IR-luminous galaxies at 1 < z < 3 predominantly powered by star formation. The first spectrum of a 350 micrometer selected galaxy provides an additional confirmation, showing prominent dust grain features typically associated with star-forming galaxies. Compared to submillimeter galaxies selected at 850 and 1100 micrometers, galaxies selected at 350 micrometers have a similar range of far-infrared color temperatures. However, no 350 micrometer selected sources are reliably detected at 850 or 1100 micrometers. Galaxies in our sample with redshifts 1 < z < 2 show a tight correlation between the far- and mid-infrared flux densities, but galaxies at higher redshifts show a large dispersion in their mid- to far-infrared colors. This implies a limit to which the mid-IR emission traces the far-IR emission in star-forming galaxies. The 350 micrometer flux densities (15 < S(sub 350) < 40 mJy) place these objects near the Herschel/SPIRE 350 micrometer confusion threshold, with the lower limit on the star formation rate density suggesting the bulk of the 350 micrometers contribution will come from less luminous infrared sources and normal galaxies. Therefore, the nature of the dominant source of the 350 micrometers background-star-forming galaxies in the epoch of peak star formation in the universe-could be more effectively probed using ground-based instruments with their angular resolution and sensitivity offering significant advantages over space-based imaging. Key words: galaxies: high-redshift galaxies: starburst infrared: galaxies submillimeter

Khan, Sophia A.↗

X-ray optics for the LAMAR facility, an overview

The paper surveys the Large Area Modular Array of Reflectors (LAMAR), the concept of which is based on meeting two major requirements in X-ray astronomy, large collecting area and moderately good or better angular resolution for avoiding source confusion and imaging source fields. It is shown that the LAMAR provides the same sensitivity and signal to noise in imaging as a single large telescope having the same area and angular resolution but is a great deal less costly to develop, construct, and integrate into a space mission. Attention is also given to the LAMAR modular nature which will allow for an evolutionary development from a modest size array on Spacelab to a Shuttle launched free flyer. Finally, consideration is given to manufacturing methods which show promise of making LAMAR meet the criteria of good angular resolution, relatively low cost, and capability for fast volume production.

Gorenstein, P.↗

Radio and optical interferometric imaging

Since diffraction-limited imaging with a single aperture yields angular resolution approx. lambda/D, the attainment of high angular resolution with single apertures requires the construction of correspondingly large monolithic apertures, the whole surface of which must be figured to much less than a wavelength. At the longer wavelengths, it is impossible to build a sufficiently large single aperture: for example, at lambda 21 cm, arcsec resolution requires an aperture of diameter approx. 50 km. At the shorter wavelengths, the atmosphere imposes a natural limit in resolution of about one arcsec. However, another route is possible; that is, using synthetic apertures to image the sky. Synthetic apertures are now in use in many fields, e.g., radio interferometry, radar imaging, and magnetic-resonance imaging. Radio-interferometric techniques developed in radio astronomy over the past 40 years are now being applied to optical and IR astronomical imaging by a number of groups. Furthermore, the problem of figuring synthetic apertures is considerably simpler, and can be implemented in a computer: new 'self-calibration' techniques allow imaging even in the presence of phase errors due to the atmosphere.

Cornwell, Tim J.↗

The Space Infrared Interferometric Telescope (SPIRIT)

We report preliminary results of a study of the Space Infrared Interferometric Telescope (SPIRIT), a candidate Origins Probe mission. SPIRIT is a two-element Michelson interferometer operating over a nominal wavelength range 25 to 400 microns and offering a powerful combination of spectroscopy and sub-arcsecond angular resolution imaging in a single instrument. With angular resolution comparable to that of JWST and far-IR sensitivity nearly two orders of magnitude better than that of the Spitzer Space Telescope, SPIRIT will measure the resonant structures in exozodi debris disks to find and characterize extrasolar planets; characterize the atmospheres of selected extrasolar gas giant planets; elucidate the evolution of young stellar systems and their planet-forming potential; and track the luminosity evolution and chemical and dust enrichment of galaxies on a cosmological timescale. SPIRIT could be ready to launch as early as 2015. The SPIRIT study is sponsored by NASA under the Origins Science Mission Concept study program.

Leisawitz, David↗

The Generation-X X-ray Observatory Vision Mission and Technology Study

The new frontier in astrophysics is the study of the birth and evolution of the first stars, galaxies and black holes in the early Universe. X-ray astronomy opens a window into these objects by studying the emission from black holes, supernova explosions and the gamma-ray burst afterglows of massive stars. However, such objects are beyond the grasp of current or near-future observatories. X-ray imaging and spectroscopy of such distant objects will require an X-ray telescope with large collecting area and high angular resolution. Our team has conceived the Generation-X Vision Mission based on an X-ray observatory with 100 sq m collecting area at 1 keV (1000 times larger than Chandra) and 0.1 arcsecond angular resolution (several times better than Chandra and 50 times better than the Constellation-X resolution goal). Such an observatory would be capable of detecting the earliest black holes and galaxies in the Universe, and will also study extremes of density, gravity, magnetic fields, and kinetic energy which cannot be created in laboratories. NASA has selected the Generation-X mission for study under its Vision Mission Program. We describe the studies being performed to develop the mission concept and define candidate technologies and performance requirements for Generation-X. The baseline Generation-X mission involves four 8m diameter X-ray telescopes operating at Sun-Earth L2. We trade against an alternate concept of a single 26m diameter telescope with focal plane instruments on a separate spacecraft. A telescope of this size will require either robotic or human-assisted in-flight assembly. The required effective area implies that extremely lightweight grazing incidence X-ray optics must be developed. To achieve the required aerial density of at least 100 times lower than in Chandra, we will study 0.1mm thick mirrors which have active on-orbit figure control. We discuss the suite of required detectors, including a large FOV high angular resolution imager, a cryogenic imaging spectrometer and a grating spectrometer. We outline the development roadmap to confront the many technological challenges far implementing the Generation-X mission.

Figueroa-Feliciano, Enectali↗

Development of High Resolution Hard X-Ray Telescope with Multi-Layer Coatings

This is the annual report for the third year of a three-year program. Previous annual reports have described progress achieved in the first and second years. The major objective of this program is the development of a focusing hard X-ray telescope with moderately high angular resolution, i.e. comparable to the telescopes of XMM-Newton. The key ingredients of the telescope are a depth graded multilayer coatings and electroformed nickel substrates that are considerably lighter weight than those of previous missions such as XMM-Newton, which have had conventional single metal layer reflective coatings and have operated at much lower energy X-rays. The ultimate target mission for this technology is the Hard X-Ray Telescope (HXT) of the Constellation X-Ray Mission. However, it is applicable to potential SMEX and MIDEX programs as well. We are building upon technology that has proven to be successful in the XMM-Newton and SWIFT missions. The improvements that we are adding are a significant reduction in mass without much loss of angular resolution and an order of magnitude extension of the bandwidth through the use of multilayer coatings. The distinctive feature of this approach compared to those of other hard X-ray telescope programs is that we expect the angular resolution to be superior than telescopes made by other methods thanks to the structural integrity of the substrates. They are thin walled complete cylinders of revolution with a Wolter Type 1 figure; the front half is a parabola, the rear half a hyperbola.

Gorenstein, Paul↗

X-Ray Optics for the 2020s

Three factors characterize an X-ray optics technology: angular resolution, effective area per unit mass, and production cost per unit effective area. In general, these three factors are always in conflict with one another. Every telescope that has flown so far represents an astronomically useful compromise of these factors. Of three operating X-ray telescopes, Chandra has been optimized for angular resolution (0.5); Suzaku for effective area per unit mass; and both were optimized in its own way to minimize production cost. Optics for the decade of2020 requires a combination of Chandra's angular resolution and Suzaku's effective area per unit mass. In this talk I will briefly review X -ray optics fabrication techniques that have been used in the past three decades and then present my expectations for the 2020s. In particular I will propose a couple of new techniques that should be investigated for making lightweight and high resolution X-ray optics.

Zhang, William↗