Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ambient temperature effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Two-dimensional thermal modeling of power monolithic microwave integrated circuits (MMIC's)

Numerical simulations of the two-dimensional temperature distributions for a typical GaAs MMIC circuit are conducted, aiming at understanding the heat conduction process of the circuit chip and providing temperature information for device reliability analysis. The method used is to solve the two-dimensional heat conduction equation with a control-volume-based finite difference scheme. In particular, the effects of the power dissipation and the ambient temperature are examined, and the criterion for the worst operating environment is discussed in terms of the allowed highest device junction temperature.

Fan, Mark S.↗

Soil Characterizations of Five Urban Sites in Knoxville, Tennessee. 2024-2025

This dataset includes soil characterizations from five urban parks in Knoxville, Tennessee, USA: Cumberland Estates Park (CEP), Socially Equal Energy Efficient Development (SEED), West View Park (WVP), Victor Ashe Park (VAP), and West Hills Park (WHP). The dataset consists of seven CSV files reporting the data from the measurements of gravimetric moisture content, pH, total carbon and nitrogen, soil texture, dissolved organic carbon and nitrogen, and microbial biomass carbon and nitrogen derived from these soil cores. During five separate sampling events conducted in 2024 and 2025, five soil cores were collected at each site within 3 meters of the remote soil monitoring equipment. In 2025, an additional three soil cores were collected adjacent to the monitoring equipment at each site to assess soil bulk density. This dataset is part of a larger study investigating the effects of soil moisture and plant evapotranspiration on ambient temperature and relative humidity across multiple urban parks in Knoxville, Tennessee.

Mayes, Melanie A [ORNL] (ORCID:0000000163689210)↗

Thermal Insulation System for Non-Vacuum Applications Including a Multilayer Composite

The thermal insulation system of the present invention is for non-vacuum applications and is specifically tailored to the ambient pressure environment with any level of humidity or moisture. The thermal insulation system includes a multilayered composite including i) at least one thermal insulation layer and at least one compressible barrier layer provided as alternating, successive layers, and ii) at least one reflective film provided on at least one surface of the thermal insulation layer and/or said compressible barrier layer. The different layers and materials and their combinations are designed to provide low effective thermal conductivity for the system by managing all modes of heat transfer. The thermal insulation system includes an optional outer casing surrounding the multilayered composite. The thermal insulation system is particularly suited for use in any sub-ambient temperature environment where moisture or its adverse effects are a concern. The thermal insulation system provides physical resilience against damaging mechanical effects including compression, flexure, impact, vibration, and thermal expansion/contraction.

Fesmire, James E.↗

Laminar Diffusion Flame Studies (Ground- and Space-Based Studies)

Laminar diffusion flames are of interest because they provide model flame systems that are far more tractable for analysis and experiments than more practical turbulent diffusion flames. Certainly, understanding flame processes within laminar diffusion flames must precede understanding these processes in more complex turbulent diffusion flames. In addition, many properties of laminar diffusion flames are directly relevant to turbulent diffusion flames using laminar flamelet concepts. Laminar jet diffusion flame shapes (luminous flame boundaries) have been of particular interest since the classical study of Burke and Schumann because they are a simple nonintrusive measurement that is convenient for evaluating flame structure predictions. Thus, consideration of laminar flame shapes is undertaken in the following, emphasizing conditions where effects of gravity are small, due to the importance of such conditions to practical applications. Another class of interesting properties of laminar diffusion flames are their laminar soot and smoke point properties (i.e., the flame length, fuel flow rate, characteristic residence time, etc., at the onset of soot appearance in the flame (the soot point) and the onset of soot emissions from the flame (the smoke point)). These are useful observable soot properties of nonpremixed flames because they provide a convenient means to rate several aspects of flame sooting properties: the relative propensity of various fuels to produce soot in flames; the relative effects of fuel structure, fuel dilution, flame temperature and ambient pressure on the soot appearance and emission properties of flames; the relative levels of continuum radiation from soot in flames; and effects of the intrusion of gravity (or buoyant motion) on emissions of soot from flames. An important motivation to define conditions for soot emissions is that observations of laminar jet diffusion flames in critical environments, e.g., space shuttle and space station facilities, cannot involve soot emitting flames in order to ensure that test chamber windows used for experimental observations are not blocked by soot deposits, thereby compromising unusually valuable experimental results. Another important motivation to define conditions where soot is present in diffusion flames is that flame chemistry, transport and radiation properties are vastly simplified when soot is absent, making such flames far more tractable for detailed numerical simulations than corresponding soot-containing flames. Motivated by these observations, the objectives of this phase of the investigation were as follows: (1) Observe flame-sheet shapes (the location of the reaction zone near phi=1) of nonluminous (soot free) laminar jet diffusion flames in both still and coflowing air and use these results to develop simplified models of flame-sheet shapes for these conditions; (2) Observe luminous flame boundaries of luminous (soot-containing) laminar jet diffusion flames in both still and coflowing air and use these results to develop simplified models of luminous flame boundaries for these conditions. In order to fix ideas here, maximum luminous flame boundaries at the laminar smoke point conditions were sought, i.e., luminous flame boundaries at the laminar smoke point; (3) Observe effects of coflow on laminar soot- and smoke-point conditions because coflow has been proposed as a means to control soot emissions and minimize the presence of soot in diffusion flames.

Dai, Z.↗

Building hypotheses to understand the synergistic effects of heat and pollution exposure in a changing climate

The increasing intensity, frequency, and duration of extreme weather events due to climate change poses a broad range of health risks, and the synergistic effects of extreme temperature co-occurring with other hazardous exposures such as air pollution may result in higher risks of all-cause mortality and cardiovascular and respiratory morbidity than exposure to either event alone. There are a number of hypothesized mechanisms for this interaction effect, including increased susceptibility to heat effects on chronic conditions affected by air pollution exposure, exacerbation of pollution effects due to temperature-induced stress, and shared pathophysiological pathways (e.g., systemic inflammation), but specific physiological mechanisms are not well understood. In this editorial, the authors discuss this aspect of a recently published study examining ambient formaldehyde combined with high temperature exposure and respiratory disease admissions among children. Here, the observation that the health effects of pollutants such as formaldehyde are amplified following periods of high temperature can help inform risk warning systems even without knowledge of the underlying physiological mechanisms, but a deeper biological understanding of the interaction effects of heat and ambient air pollution may better inform interventions. This is even more important in view of increases in both extreme temperature and pollution events tied to climate change.

Chambliss, Sarah [University of Texas at Austin, T↗

The toughest animals of the Earth versus global warming: Effects of long‐term experimental warming on tardigrade community structure of a temperate deciduous forest

Abstract Understanding how different taxa respond to global warming is essential for predicting future changes and elaborating strategies to buffer them. Tardigrades are well known for their ability to survive environmental stressors, such as drying and freezing, by undergoing cryptobiosis and rapidly recovering their metabolic function after stressors cease. Determining the extent to which animals that undergo cryptobiosis are affected by environmental warming will help to understand the real magnitude climate change will have on these organisms. Here, we report on the responses of tardigrades within a five‐year‐long, field‐based artificial warming experiment, which consisted of 12 open‐top chambers heated to simulate the projected effects of global warming (ranging from 0 to 5.5°C above ambient temperature) in a temperate deciduous forest of North Carolina (USA). To elucidate the effects of warming on the tardigrade community inhabiting the soil litter, three community diversity indices (abundance, species richness, and Shannon diversity) and the abundance of the three most abundant species ( Diphascon pingue , Adropion scoticum , and Mesobiotus sp.) were determined. Their relationships with air temperature, soil moisture, and the interaction between air temperature and soil moisture were tested using Bayesian generalized linear mixed models. Despite observed negative effects of warming on other ground invertebrates in previous studies at this site, long‐term warming did not affect the abundance, richness, or diversity of tardigrades in this experiment. These results are in line with previous experimental studies, indicating that tardigrades may not be directly affected by ongoing global warming, possibly due to their thermotolerance and cryptobiotic abilities to avoid negative effects of stressful temperatures, and the buffering effect on temperature of the soil litter substrate.

54 ENVIRONMENTAL SCIENCES↗

Asymmetric daytime and nighttime surface temperature feedback induced by crop greening across Northeast China

Mid-high latitude Northeast China witnessed significant crop greening from 2001 to 2020, as evidenced by satellite records and field observations. The land surface temperature of croplands during the growing season showed a decreasing trend, suggesting negative surface temperature feedback to crop greening of agricultural ecosystems in mid-high latitude Northeast China. Here, using time-series remote sensing products and long-term scenario simulations, the present study highlights that crop greening can slow climate warming. Our study noted a stronger surface cooling effect induced by crop greening during the growing season in the day than at the night, which contributed to asymmetric diurnal temperature cycle changes in Northeast China. In addition, our biophysical mechanism analysis revealed aerodynamic and surface resistances as the major driving factors for the daytime land surface temperature (LST) cooling effect induced by crop greening, while the ground heat flux and ambient temperature feedback as the major attributes of the nighttime LST cooling impact due to crop greening.

54 ENVIRONMENTAL SCIENCES↗

Atomic-scale mechanisms of void strengthening in tungsten

Neutron and heavy-ion irradiation of tungsten produces nanometer-size vacancy voids, gas-filled bubbles and dislocation loops. These defect features can affect mechanical properties and the impact can be quite significant because of their high density. Understanding the basic mechanisms of mechanical properties degradation is necessary for predicting radiation effects. Predictions can be made using discrete dislocation dynamics or/and finite element approaches which, however, need local interaction mechanisms as inputs. Such knowledge can be provided only by atomic-scale modeling. This paper reports the results of an extensive atomic-scale modeling study of the interactions between moving edge dislocations and voids in tungsten. Furthermore, the main focus is on the effects of the void size and ambient temperature. Critical resolved shear stress was calculated for voids up to 9 nm in diameter. Atomistic results are compared with the theoretical approach and with those obtained earlier for voids in body centered cubic (bcc) iron. An important role of the void surface has been revealed.

36 MATERIALS SCIENCE↗

Multiple Degradation Mechanisms in Reinforced Concrete Structures, Modeling and Risk Analysis

The overarching goal of this project is to complement ongoing Department of Energy (DOE) Light Water Reactor Sustainability (LWRS)-funded Grizzly concrete modeling development efforts by providing improved multi-physics models for incorporation into the Grizzly and BlackBear codes. Objectives of this work identified at the outset of this project include: 1. Coupling between mechanical damage and transport processes. The mechanical damage will be characterized by nonlinear mechanical constitutive models appropriate for concrete used in nuclear power plants (NPPs). 2. Improved representation of the coupling among the transport process, building on the current moisture and thermal transport models in Grizzly. The parameters for coupling among heat and mass transport in the multi-physics model will be experimentally determined. 3. Coupling among different scale levels of concrete constituents, fine and coarse aggregates, cement paste, hydration products, and pore structure. 4. Probabilistic analysis of the random nature of the heterogeneous concrete structure and the environmental factors (ambient temperature and humidity) and their multiple effects on concrete deterioration. 5. Benchmark verification, validation and uncertainty quantification of the thermo-hygro- chemo-mechanical (THCM) concrete formulation. The end goal of this work was to provide a comprehensive and robust simulation capability that can be applied at the engineering scale for analysis of realistic deterioration scenarios in NPP concrete structures.

36 MATERIALS SCIENCE↗

Foreign Object Damage Behavior of a SiC/SiC Composite at Ambient and Elevated Temperatures

Foreign object damage (FOD) behavior of a gas-turbine grade SiC/SiC ceramic matrix composite (CMC) was determined at 25 and 1316 C, employing impact velocities from 115 to 440 meters per second by 1.59-mm diameter stell-ball projectiles. Two different types of specimen support were used at each temperature: fully supported and partially supported. For a given temperature, the degree of post-impact strength degradation increased with increasing impact velocity, and was greater in a partially supported configuration than in a fully supported one. The elevated-temperature FOD resistance of the composite, particularly under partially supported loading at higher impact velocities greater than or equal to 350 meters per second, was significantly less than the ambient-temperature counterpart, attributed to a weakening effect of the composite. For fully supported loading, frontal contact stress played a major role in generating composite damage; whereas, for partially supported loading, both frontal contact and backside bending stresses were combined sources of damage generation. The SiC/SiC composite was able to survive higher energy impacts without complete structural failure but suffered more strength affecting damage from low energy impacts than AS800 and SN282 silicon nitrides.

Bhatt, Ramakrishna T.↗

Cryogenic Storage Tank Non-Destructive Evaluation

This slide presentation reviews the work in non-destructive evaluation (NDE) of cryogenic storage tanks. Four large cryogenic tanks, constructed in 1965 with perlite insulation in the annular regions, are of concern. The construction of the tanks, two Liquid Oxygen (LOX) and two Liquid Hydrogen (LH2), are described. The loss rate for the LOX tank at Pad A is slightly higher than that for the one at Pad B. The concerns for the LH2 tank at Pad B are that there is a significantly higher boil-off rate than that at Pad A, that there is mold growth, indicative of increased heat flow, that there is a long down-time needed for repairs, and that 3 of 5 full thermal cycles have been used on the Pad B LH2 tank. The advantages and disadvantages of thermal imaging are given. A detailed description of what is visible of the structures in the infra-red is given and views of the thermal images are included. Missing Perlite is given as the probable cause of the cold spot on the Pad B LH2 tank. There is no indications of problematic cold regions on the Pad A LH2 tank, as shown by the thermal images given in the presentation. There is definite indication of a cold region on the Pad A LOX tank. There is however concerns with thermal imaging, as thermal images can be significantly effected by environmental conditions, image differences on similar days but with different wind speeds. Other effects that must be considered include ambient temperature, humidity levels/dew, and cloud reflections

Arens, Ellen↗

Digital control of diode laser for atmospheric spectroscopy

A system is described for remote absorption spectroscopy of trace species using a diode laser tunable over a useful spectral region of 50 to 200 cm(-1) by control of diode laser temperature over range from 15 K to 100 K, and tunable over a smaller region of typically 0.1 to 10 cm(-1) by control of the diode laser current over a range from 0 to 2 amps. Diode laser temperature and current set points are transmitted to the instrument in digital form and stored in memory for retrieval under control of a microprocessor during measurements. The laser diode current is determined by a digital to analog converter through a field effect transistor for a high degree of ambient temperature stability, while the laser diode temperature is determined by set points entered into a digital to analog converter under control of the microprocessor. Temperature of the laser diode is sensed by a sensor diode to provide negative feedback to the temperature control circuit that responds to the temperature control digital to analog converter.

Menzies, R. T.↗

Response of cloud supersaturation to radiative forcing

Time-dependent solutions are obtained for droplet temperatures and supersaturation, in a study of the diffusional growth or evaporation of cloud droplets due to net emission or absorption of radiation, taking into account the partitioning of the net radiation budget between the droplets and the ambient air. Radiative perturbations are noted to result in very high rates of change in droplet temperatures. As the droplets evaporate or grow due to radiative effects, the saturation ratio of the ambient air adjusts in keeping with changes in the water vapor density and temperature of the air.

Davies, R.↗

A rigorous framework for an improved Messinger/Myers model of ice accretion under conditions of variable property and unsteady aircraft icing

We analyse the Messinger/Myers model by critically evaluating simplifying assumptions through a rigorous formulation of the rime ice accretion process. We explore the effects of both constant and variable ice density and thermal conductivity, along with the effects of sublimation from the ice surface. The effects of key factors such as droplet impact rate, ambient temperature relative to the freezing temperature and the temperature difference between the ambient air and the airfoil surface are examined. Under these varying conditions, the present rigorous formulation is used to assess the significance of unsteady effects, variable ice properties and sublimation. We observe that the Myers model performs remarkably well in certain icing situations and analyse the reasons for this strong performance. We also show that partially relaxing the model’s assumptions can lead to poorer performance. The Myers model can lead to overprediction of ice surface temperature and correspondingly underprediction of transition time under conditions of relatively weak sublimation and surface cooling. A modified Myers model is presented, which can be used to recover near-perfect results under widely varying icing conditions of relevance. This article is part of the theme issue ‘Heat and mass transfer in frost and ice’.

Science & Technology - Other Topics↗

Impact of soiling on Si and CdTe PV modules: Case study in different Brazil climate zones

Soiling, particulate accumulation on photovoltaic (PV) module surfaces, reduces the available solar resource and the resulting generated device power. This case-study summarizes initial results of 5-year research on the contrasting soiling conditions in the tropical, subtropical, and semi-arid climates in Brazil. A major objective is to present a case study of the effects of soiling on PV module performance in different Brazil climate zones that represent the primary areas for the current and expanding Brazil solar installations. For this, the paper presents methodologies to quantify the soiling ratio (SRatio) and soiling rate (SRate) for two representative commercial technologies, polycrystalline or multicrystalline silicon (mc-Si) and thin-film cadmium telluride (CdTe) modules, through soiling monitoring stations deployed in the selected climate regions. An aim is to add to the growing soiling-research knowledge base through addressing these key factors and their relationships to critical electrical, solar resource, thermal, and local meteorological and environmental parameters. This paper presents, evaluates, and compares soiling rates and losses in Belo Horizonte, Minas Gerais (Equatorial Tropical: 19.92° S, 43.99° W), Porto Alegre, Rio Grande do Sul (Humid-Subtropical: 30.05° S, 51.17° W), and Brotas de Macaúbas, Bahia (Semi-Arid: 12.00° S, 42.63° W). The results show that soiling is moderate in all 3-regions, for example with 0.1%/day < SRate < 0.2%/day for Belo Horizonte. Precipitation dominates the cleaning of the modules in the summertime in this climate zone, while it is the major factor year-round in Rio Grande do Sul. Wind is the major issue mitigating the soiling accumulation for the Bahia installation. The methodology incorporates several key refinements, including the normalization and adjustment for the meteorological parameters (temperature, irradiance, wind, precipitation). The evaluations include the region-specific differing effects of non-uniform soiling, natural cleaning, and ambient temperatures.

14 SOLAR ENERGY↗

Best Practices for Body Temperature Measurement with Infrared Thermography: External Factors Affecting Accuracy

Infrared thermographs (IRTs) are commonly used during disease pandemics to screen individuals with elevated body temperature (EBT). To address the limited research on external factors affecting IRT accuracy, we conducted benchtop measurements and computer simulations with two IRTs, with or without an external temperature reference source (ETRS) for temperature compensation. The combination of an IRT and an ETRS forms a screening thermograph (ST). We investigated the effects of viewing angle (θ, 0–75°), ETRS set temperature (T ETRS , 30–40 °C), ambient temperature (T atm , 18–32 °C), relative humidity (RH, 15–80%), and working distance (d, 0.4–2.8 m). We discovered that STs exhibited higher accuracy compared to IRTs alone. Across the tested ranges of T atm and RH, both IRTs exhibited absolute measurement errors of less than 0.97 °C, while both STs maintained absolute measurement errors of less than 0.12 °C. The optimal T ETRS for EBT detection was 36–37 °C. When θ was below 30°, the two STs underestimated calibration source (CS) temperature (T CS ) of less than 0.05 °C. The computer simulations showed absolute temperature differences of up to 0.28 °C and 0.04 °C between estimated and theoretical temperatures for IRTs and STs, respectively, considering d of 0.2–3.0 m, T atm of 15–35 °C, and RH of 5–95%. The results highlight the importance of precise calibration and environmental control for reliable temperature readings and suggest proper ranges for these factors, aiming to enhance current standard documents and best practice guidelines. These insights enhance our understanding of IRT performance and their sensitivity to various factors, thereby facilitating the development of best practices for accurate EBT measurement.

47 OTHER INSTRUMENTATION↗

Impact of acute temperature and air pollution exposures on adult lung function: A panel study of asthmatics

Background Individuals with respiratory conditions, such as asthma, are particularly susceptible to adverse health effects associated with higher levels of ambient air pollution and temperature. This study evaluates whether hourly levels of fine particulate matter (PM 2.5 ) and dry bulb globe temperature (DBGT) are associated with the lung function of adult participants with asthma. Methods and findings Global positioning system (GPS) location, respiratory function (measured as forced expiratory volume at 1 second (FEV 1 )), and self-reports of asthma medication usage and symptoms were collected as part of the Exposure, Location, and Lung Function (ELF) study. Hourly ambient PM 2.5 and DBGT exposures were estimated by integrating air quality and temperature public records with time-activity patterns using GPS coordinates for each participant (n = 35). The relationships between acute PM 2.5 , DBGT, rescue bronchodilator use, and lung function collected in one week periods and over two seasons (summer/winter) were analyzed by multivariate regression, using different exposure time frames. In separate models, increasing levels in PM 2.5 , but not DBGT, were associated with rescue bronchodilator use. Conversely DBGT, but not PM 2.5 , had a significant association with FEV 1 . When DBGT and PM 2.5 exposures were placed in the same model, the strongest association between cumulative PM 2.5 exposures and the use of rescue bronchodilator was identified at the 0–24 hours (OR = 1.030; 95% CI = 1.012–1.049; p-value = 0.001) and 0–48 hours (OR = 1.030; 95% CI = 1.013–1.057; p-value = 0.001) prior to lung function measure. Conversely, DBGT exposure at 0 hours (β = 3.257; SE = 0.879; p-value>0.001) and 0–6 hours (β = 2.885; SE = 0.903; p-value = 0.001) hours before a reading were associated with FEV 1 . No significant interactions between DBGT and PM 2.5 were observed for rescue bronchodilator use or FEV 1 . Conclusions Short-term increases in PM 2.5 were associated with increased rescue bronchodilator use, while DBGT was associated with higher lung function (i.e. FEV 1 ). Further studies are needed to continue to elucidate the mechanisms of acute exposure to PM 2.5 and DBGT on lung function in asthmatics.