Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “all electric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Quantum Sensing of Electric Fields Using Spin-Correlated Radical Ion Pairs

Quantum sensing affords the possibility of using quantum entanglement to probe electromagnetic fields with exquisite sensitivity. In this work, we show that a photogenerated spin-correlated radical ion pair (SCRP) can be used to sense an electric field change created at one radical ion of the pair using molecular recognition. The SCRP is generated within a covalent donor–chromophore–acceptor system PXX–PMI–NDI, 1, where PXX = peri-xanthenoxanthene, PMI = 1,6-bis(p-t-butylphenoxy)perylene-3,4-dicarboximide, and NDI = naphthalene-1,8:4,5-bis(dicarboximide). The electron-rich PXX donor in 1 acts as a guest molecule that can be encapsulated selectively by a tetracationic cyclophane ExBox4+ host to give a supramolecular complex 1 ⊂ ExBox 4+ . Selective photoexcitation of the PMI chromophore results in ultrafast generation of the PXX •+ –PMI–NDI •– SCRP. When PXX is encapsulated by ExBox 4+ , the cyclophane generates an electric field that repels the positive charge on PXX •+ within PXX •+ –PMI–NDI •– , reducing the SCRP distance, i.e., the distance between the centers-of-charge on the donor and acceptor. Pulse-EPR measurements are used to measure the coherent oscillations created primarily by the electron–electron dipolar coupling in the SCRP, which yields the distance between the two charges (spins) of PXX •+ –PMI–NDI •– . Here, the experimental results show that the distance between PXX •+ and NDI •– decreases when ExBox 4+ encapsulates PXX •+ , which demonstrates that the SCRP can function as a quantum sensor to detect electric field changes in the vicinity of the radical ions.

Anions↗

Assessment of Envelope- and Machine Learning-Based Electrical Fault Type Detection Algorithms for Electrical Distribution Grids

This study introduces envelope- and machine learning (ML)-based electrical fault type detection algorithms for electrical distribution grids, advancing beyond traditional logic-based methods. The proposed detection model involves three stages: anomaly area detection, ML-based fault presence detection, and ML-based fault type detection. Initially, an envelope-based detector identifying the anomaly region was improved to handle noisier power grid signals from meters. The second stage acts as a switch, detecting the presence of a fault among four classes: normal, motor, switching, and fault. Finally, if a fault is detected, the third stage identifies specific fault types. This study explored various feature extraction methods and evaluated different ML algorithms to maximize prediction accuracy. The performance of the proposed algorithms is tested in an emulated software–hardware electrical grid testbed using different sample rate meters/relays, such as SEL735, SEL421, SEL734, SEL700GT, and SEL351S near and far from an inverter-based photovoltaic array farm. The performance outcomes demonstrate the proposed model’s robustness and accuracy under realistic conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeled Electricity Demand Profiles for Electric Transit Bus Depots in the United States

Hourly one-week electricity demand profiles for electric transit bus depots in the United States, as described in Liu et al. (2025). Please cite as: Liu, Bo, Tim Jonas, Kara Podkaminer, and Brennan Borlaug. 2025. Hourly Load Profile Dataset for Electric Transit Bus Depots in the United States. Golden, CO: National Renewable Energy Laboratory. NREL/TP-5400-92140. https://www.nlr.gov/docs/fy25osti/92140.pdf

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Electric Propulsion for Flight - Hybrid Electric Aircraft Research at AFRC

Advances in electric machine efficiency and energy storage capability are enabling a new alternative to traditional propulsion systems for aircraft. This has already begun with several small concept and demonstration vehicles, and NASA projects this technology will be essential to meet energy and emissions goals for commercial aviation in the next 30 years. In order to raise the Technology Readiness Level of electric propulsion systems, practical integration and performance challenges will need to be identified and studied in the near-term so that larger, more advanced electric propulsion system testbeds can be designed and built. Researchers at NASA Armstrong Flight Research Center are building up a suite of test articles for the development, integration, and validation of these systems in a real world environment.

electric propulsion↗

Drive Cycles, Battery Pack Scaling, and Usage Considerations for Long-Haul and Regional-Haul Electric Trucks

Electrifying Class-8 heavy-duty trucks presents a promising opportunity to enhance energy efficiency and reduce freight transport costs. Battery electric trucks (BETs), once considered niche, are gaining traction due to advancements in battery technology and cost reductions. However, accurately predicting battery lifespan under realistic usage conditions remains a key challenge. Understanding battery failure mechanisms and their links to design, operation, and management is essential for developers and fleet operators. This study introduces a method to develop simplified, lab-testable dynamic stress test (DST) cycles for regional and long-haul Class-8 BETs, derived from real-world diesel truck usage. These DSTs enable benchmarking of battery technologies, identification of aging stressors, and optimization of battery design, life, and cost. The approach supports evaluation of key metrics such as levelized cost of driving and total cost of ownership, aiding fair comparisons and adoption decisions. We also propose feasible battery pack sizes that meet current driving demands with strategic charging, and a method to scale pack-level DSTs to cell-level cycles for lab-based testing. These tools facilitate tradeoff analysis across battery chemistries, pack sizing, and charging strategies, while offering means to get insights into battery aging under realistic conditions-ultimately supporting informed BET deployment decisions.

25 ENERGY STORAGE↗

Responses of the AC/DC Global Electric Circuit to Volcanic Electrical Activity in the Hunga Tonga-Hunga Ha'apai Eruption on 15 January 2022

Responses of the AC and DC global electric circuits (GECs) to the large eruption of the Hunga Tonga-Hunga Ha'apai (HT-HH) volcano on 15 January 2022 are discussed. The AC-related investigation is based on Schumann resonance (SR) measurements from six stations on four continents. The DC-related investigation utilizes atmospheric electric field (potential gradient, PG) measurements from six recording stations in Europe and the USA. According to data from the GLD360 and WWLLN lightning detection networks, the peak lightning stroke rate, 83/s, was dominated by negative polarity lightning, but the distributions of positive and negative lightning discharges in latitude and longitude around the volcano differed. A global intensification of SR is apparent in connection with the enhanced lightning activity caused by the eruption. SR data-based results confirm that the lightning activity in the eruption dominated the naturally occurring global activity for a period of about 1 hr. The highly localized increase in lightning activity over HT-HH was a unique point source of SR excitation. PG measurements suggest that impulse-like charging of the DC GEC, by ~15%, via negative cloud-to-ground lightning strokes took place twice during the eruption. A time constant of 7 or 8 min has been inferred for near-surface PG changes due to these enhancements. This could be the first direct measurement of the time constant of the GEC near the Earth's surface, as well as the first observation of the direct charging of the DC GEC by a unique atmospheric electrified source.

58 GEOSCIENCES↗

Foundation Models for the Electric Power Grid

Foundation models (FMs) currently dominate news headlines. They employ advanced deep learning architectures to extract structural information autonomously from vast datasets through self-supervision. The resulting rich representations of complex systems and dynamics can be applied to many downstream applications. Therefore, advances in FMs can find uses in electric power grids, challenged by the energy transition and climate change. This paper calls for the development of FMs for electric grids. We highlight their strengths and weaknesses amidst the challenges of a changing grid. It is argued that FMs learning from diverse grid data and topologies, which we call grid foundation models (GridFMs), could unlock transformative capabilities, pioneering a new approach to leveraging AI to redefine how we manage complexity and uncertainty in the electric grid. Finally, we discuss a practical implementation pathway and road map of a GridFM-v0, a first GridFM for power flow applications based on graph neural networks, and explore how various downstream use cases will benefit from this model and future GridFMs.

AI-based power flow simulation↗

Reducing dielectric loss and enhancing electrical insulation for multilayer polymer films by nanoconfined ion transport under high poling electric fields

High temperature polar polymers have demonstrated potential for good thermal stability and high dielectric constant at the same time. However, polarization of contaminated impurity ions in polar polymers, even at the ppm level, can significantly increase the dielectric loss at high temperature and low frequencies. One effective strategy to mitigate this problem is to multilayer them with a high temperature nonpolar dielectric polymer to confine impurity ion transport at the nanometer scale. In this study, confined ion transport in high temperature polycarbonate (HTPC)/poly(vinylidene fluoride) (PVDF) multilayer films under high AC electric fields was studied using a direct analytical simulation method. Different from the ion transport under low fields, the ion diffusion model failed to describe the ion transport under high electric fields. An exponential ion distribution profile, which was observed for the DC poling situation, was employed to implement the direct analytical simulation. Confined impurity ion transport under high AC fields was quantitatively understood. As the AC field increased, the mobile ion concentration decreased whereas the diffusion coefficient increased. The decrease of mobile ion concentration was explained by the blockage of impurity ions by the HTPC layers. This knowledge helped in the determination of optimal conditions to polarize impurity ions from the PVDF layers into the HTPC layers. After cooling below the glass transition temperature of HTPC, polarized impurity ions were locked inside the HTPC layers. As a result, increased discharge efficiency and enhanced electrical insulation (i.e., increased dielectric breakdown strength) were achieved for the polarized multilayer films.

36 MATERIALS SCIENCE↗

Coordinating the electric vehicle transition and electricity grid decarbonization in the U.S. is not essential to achieving substantial long-term carbon dioxide emissions reductions

Abstract How quickly the US can decarbonize light-duty vehicle (LDV) transportation depends on the rates of change of electric vehicle (EV) sales, stock turnover, and grid decarbonization. We build a stock turnover model to assess how sensitive achieving 2050 LDV decarbonization targets is to these rates. We estimate carbon dioxide (CO 2 ) reductions of 70%–85% by 2050, including emissions from vehicles and upstream electricity generation, provided that new vehicle sales transition to 100% EVs and substantial grid decarbonization are accomplished by 2050. This result is robust to continuation of long-term trends of increasing vehicle longevity, and to whether the timing of EV sales growth and grid decarbonization are coordinated. If the two key goals are met, the annual contribution of EV electricity use to CO 2 emissions will be small over the entire period.

Leard, Benjamin↗

Bulk photospin effect: Calculation of electric spin susceptibility to second order in an electric field

Here, we compute the electric spin susceptibility of Bloch electrons with spin-orbit coupling to second order. We find that it is possible to generate a nonequilibrium spin polarization in the bulk of nonmagnetic inversion-symmetric materials using linearly polarized electric fields, but the process depends on interband coherence and produces heating. It may be possible to avoid heating with circular polarization in certain scenarios. The standard Edelstein effect and spin orientation effects are recovered in appropriate limits within the formalism. Finally, the electric spin susceptibility of metals has contributions proportional to spin multipole moments of the Fermi sea that dominate the low frequency spin response.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Overview of Electrically Conductive and Active Shielding for Wireless Power Transfer with a Polyphase Wireless Electric Vehicle Charging Study

The development and deployment of wireless power transfer (WPT) is increasing across industries including applications in healthcare, sensing and telecommunications, and electric vehicle charging due to its increased mobility and convenience. An important aspect of wireless power transfer is shielding to limit the intensity of electromagnetic fields (EMF) within external regions to protect users and nearby technology. Within this paper, the classifications and recent developments in shielding technologies are reviewed with discussion on potential benefits and drawbacks towards application for wireless charging of electric vehicles (EV). Additionally, a design study is proposed and simulated in 3D FEA for a novel active shield to substantially reduce magnetic field emissions of a high-power, high-frequency rotating-field 3-phase electromagnetic coupler for quickly charging electric vehicles. The active shield, designed to reduce Z-axis emissions, was found to be highly effective, reducing maximum EMF emissions by 83% in aligned static operation and by 50% with lateral misalignment. Active shielding was also found to strongly mitigate the impact of lateral misalignment at each studied partial alignment.

Lewis, Donovin D.↗

Suppression of coherent interference to electric-field-induced second-harmonic (E-FISH) signals for the measurement of electric field in mesoscale confined geometries

We present spatially enhanced electric-field-induced second-harmonic (SEEFISH) generation with a chirped femtosecond beam for measurements of electric field in mesoscale confined geometries subject to destructive spurious second-harmonic generation (SHG). Spurious SHG is shown to interfere with the measured E-FISH signal coherently, and thus simple background subtraction is not sufficient for single-beam E-FISH approaches, especially in a confined system with a large surface-to-volume ratio. The results show that a chirped femtosecond beam is effective in preventing higher-order mixing and white light generation in windows near the beam focal point which further contaminates the SEEFISH signal. The successful measurements of electric field of a nanosecond dielectric barrier discharge in a test cell demonstrated that spurious SHG detected with a congruent traditional E-FISH approach can be eliminated using the SEEFISH approach.

Vorenkamp, Madeline↗

Optical and electrical properties of proton-implanted p -GaSb for electrical isolation

The effect of proton implantation as isolation implant and subsequent annealing on the optical absorption and electrical resistivity of low-bandgap p -GaSb is reported. The measured transmittance spectra indicates that implantation creates a distribution of energy levels extending into the bandgap. Electrical measurements show that the average sheet resistance of the implanted layer increases only by an order of magnitude from its pre-implantation value at a proton dose of ~10 13 cm -2 followed by 200 °C annealing. It is also shown that annealing reduces the implantation-induced optical absorption while still retaining a high electrical resistivity.

42 ENGINEERING↗

Electrical-power-system data base for consumables analysis. Volume 1: Electrical equipment list, activity blocks, and time lines

A standardized data base is described which consists of a space shuttle electrical equipment list, activity blocks defining electrical equipment utilization, and activity-block time lines for specific mission analyses. Information is presented to facilitate utilization of the data base, to provide the basis for the electrical equipment utilization to enable interpretation of analyses based on the data contained herein.

Pipher, M. D.↗