Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “activity measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

International Space Station Increment-4/5 Microgravity Environment Summary Report

This summary report presents the results of some of the processed acceleration data measured aboard the International Space Station during the period of December 2001 to December 2002. Unlike the past two ISS Increment reports, which were increment specific, this summary report covers two increments: Increments 4 and 5, hereafter referred to as Increment-4/5. Two accelerometer systems were used to measure the acceleration levels for the activities that took place during Increment-4/5. Due to time constraint and lack of precise timeline information regarding some payload operations and station activities, not a11 of the activities were analyzed for this report. The National Aeronautics and Space Administration sponsors the Microgravity Acceleration Measurement System and the Space Acceleration Microgravity System to support microgravity science experiments which require microgravity acceleration measurements. On April 19, 2001, both the Microgravity Acceleration Measurement System and the Space Acceleration Measurement System units were launched on STS-100 from the Kennedy Space Center for installation on the International Space Station. The Microgravity Acceleration Measurement System supports science experiments requiring quasi-steady acceleration measurements, while the Space Acceleration Measurement System unit supports experiments requiring vibratory acceleration measurement. The International Space Station Increment-4/5 reduced gravity environment analysis presented in this report uses acceleration data collected by both sets of accelerometer systems: The Microgravity Acceleration Measurement System, which consists of two sensors: the low-frequency Orbital Acceleration Research Experiment Sensor Subsystem and the higher frequency High Resolution Accelerometer Package. The low frequency sensor measures up to 1 Hz, but is routinely trimmean filtered to yield much lower frequency acceleration data up to 0.01 Hz. This filtered data can be mapped to arbitrary locations for characterizing the quasi-steady environment for payloads and the vehicle. The high frequency sensor is used to characterize the vibratory environment up to 100 Hz at a single measurement location. The Space Acceleration Measurement System, which deploys high frequency sensors, measures vibratory acceleration data in the range of 0.01 to 400 Hz at multiple measurement locations. This summary report presents analysis of some selected quasi-steady and vibratory activities measured by these accelerometers during Increment- 4/5 from December 2001 to December 2002.

Jules, Kenol↗

Coherent radar measurement of ocean currents from geostationary orbit

A coherent HF radar system developed by Barrick has successfully measured ocean surface currents near shore. This innovative system, called CODAR, can map the current vector for coastal areas as large as 10,000 sq km. CODAR's range is limited owing to the strong attenuation suffered by HF ground waves. An alternate technique was proposed by Schuler, in which the cross-product power spectrum of two (different frequency) microwave signals is processed. The frequency of the resonant peak corresponds close by to the Doppler shift of an ocean gravity wave traveling toward the radar at the phase velocity, v(sub p). The slight difference between the frequency of the measured resonant delta K peak and the Doppler frequency shift caused by the motion of the gravity wave is attributed to be the current velocity in the pointing direction of the radar. The Microwave Remote Sensing Laboratory (MIRSL) has considered the feasibility of using this technique to measure ocean surface currents from geostationary satellite platforms. Problems are discussed that must be overcome if a satellite current measurement system is to be realized. MIRSL research activities that address some of these problem areas are discussed. Current measurements are presented that were made using a specially-designed C-Band, step-frequency delta K radar. These measurements suggest that progress is being achieved in detecting ocean surface current motion for a wide variety of ocean surface conditions.

Mcintosh, R. E.↗

A measurement-based study of concurrency in a multiprocessor

A systematic measurement-based methodology for characterizing the amount of concurrency present in a workload, and the effect of concurrency on system performance indices such as cache miss rate and bus activity are developed. Hardware and software instrumentation of an Alliant FX/8 was used to obtain data from a real workload environment. Results show that 35% of the workload is concurrent, with the concurrent periods typically using all available processors. Measurements of periods of change in concurrency show uneven usage of processors during these times. Other system measures, including cache miss rate and processor bus activity, are analyzed with respect to the concurrency measures. Probability of a cache miss is seen to increase with concurrency. The change in cache miss rate is much more sensitive to the fraction of concurrent code in the worklaod than the number of processors active during concurrency. Regression models are developed to quantify the relationships between cache miss rate, bus activity, and the concurrency measures. The model for cache miss rate predicts an increase in the median miss rate value as much as 300% for a 100% increase in concurrency in the workload.

Mcguire, Patrick John↗

Dynamic Frequency Regulation Improvement in Hydropower-Hybrid System using Variational Mode Decomposition

Providing frequency response, especially fast frequency response such as Red D in the Pennsylvania-New Jersey-Maryland Interconnection (PJM) market, is challenging for many generation plants to deliver on their own. If they have adequate flexibility, hydropower plants are typically able to provide slower regulation support (e.g., Reg A in PJM), but do not respond fast enough to provide Reg D. The ability to provide Reg D would improve their revenue because this service is typically more valuable. This work presents a control approach to use hydropower, battery, and ultracapacitor systems to provide fast regulation in a way that uses the response contribution of each asset. In particular, the proposed control architecture applies a variational mode decomposition (VMD) technique on the incoming Reg D signal to extract multiple dynamic-regulation components with non-overlapping frequencies. With the response-speed dependent alignment, these regulation components are fed to the hydrogenator and hybrid energy storage system (HESS). The paper evaluates the proposed approach on a direct-current (DC)-coupled active system by computing several performance measures and analyzing sensitivity based on HESS component proportional capacities. The results reveal that the proposed VMD-based signal conditioning performs well and that optimizing the sizing of the battery and ultracapacitor components further enhances performance.

13 HYDRO ENERGY↗

Chemisorption kinetics of hydrogen on evaporated iron films

Measurements were made of the isothermal adsorption-desorption kinetics for H2 chemisorbed onto Fe films. The chemisorption process is observed to proceed via a precursor state of adsorbed molecular hydrogen similar to the H2-Ni system. The first measurements of the activation energy for desorption, and estimates of the values of the fast kinetic rates between the precursor and chemisorbed states are reported. Adsorption into the precursor state does not appear to be activated, but the process connecting the precursor state with the chemisorbed state will, under certain circumstances, be a rate limiting step for adsorption. The effects of contamination of the surface are evidenced in the measurements.

Shanabarger, M. R.↗

Satellite measurements of ocean waves

Satellite measurements of the directional spectrum of ocean waves are beneficial to theoretical wave research, ocean engineering, and marine activities. Wave measurements from satellites by active microwave systems also help to analyze those processes that govern the transfer of heat, water vapor, and momentum across the air-sea interface.

Stewart, R. H.↗

Snow backscatter in the 1-8 GHz region

The 1-8 GHz microwave active spectrometer system was used to measure the backscatter response of snow covered ground. The scattering coefficient was measured for all linear polarization combinations at angles of incidence between nadir and 70 deg. Ground truth data consisted of soil moisture, soil temperature profile, snow depth, snow temperature profile, and snow water equivalent. The radar sensitivity to snow water equivalent increased in magnitude with increasing frequency and was almost angle independent for angles of incidence higher than 30 deg, particularly at the higher frequencies. In the 50 deg to 70 deg angular range and in the 6 to 8 GHz frequency range, the sensitivity was typically between -0.4 dB/.1 g/sq cm and -0.5 dB/,1 g/sq cm, and the associated linear correlation coefficient had a magnitude of about 0.8.

Ulaby, F. T.↗

Rain rate measurement capabilities using a Seasat type radar altimeter

The combined use of a space-based radar and a radiometer for measurement of precipitation is discussed. Phenomena to exploit or overcome is surveyed. Basic measurement problems are discussed. Several active systems are proposed, including three ocean systems and two land-sea systems. Recommendations for future research are given.

Goldhirsh, J.↗

Environmental Impact Overview

Aircraft emissions are deposited throughout the atmosphere, and at the lower stratosphere and upper troposphere they have greater potential to change ozone abundance and affect climate. There are significant uncertainties arising from the incomplete knowledge of the composition and evolution of the exhaust emissions, particularly regarding reactive trace species, particles, and their gaseous precursors. NASA Glenn Research Center at Lewis Field has considered its role in answering these challenges and has been committed to strengthening its aerosol/particulate research capabilities with initial emphasis on establishing advanced measurement systems and a particulate database. Activities currently supported by the NASA Ultra-Efficient Engine Technology (UEET) Program and accomplishment up to date will be described.

Peddie, Catherine↗

Preliminary results of the first static calibration of the RSRA helicopter active-isolator rotor balance system

The helicopter version of the Rotor Systems Research Aircraft (RSRA) is designed to make simultaneous measurements of all rotor forces and moments in flight analogous to a wind tunnel balance. Loads are measured by a combination of load cells, strain gages, and hydropneumatic active isolators which use pressure gages to measure loads. Complete evaluation of system performance required calibration of the rotor force and moment measuring system when installed in the aircraft. Measurement system responses to rotor loads obtained during the first static calibration of the RSRA helicopter are plotted and discussed. Plots of the raw transducer data are included.

Acree, C. W., Jr.↗

A measurement system for large, complex software programs

This paper describes measurement systems required to forecast, measure, and control activities for large, complex software development and support programs. Initial software cost and quality analysis provides the foundation for meaningful management decisions as a project evolves. In modeling the cost and quality of software systems, the relationship between the functionality, quality, cost, and schedule of the product must be considered. This explicit relationship is dictated by the criticality of the software being developed. This balance between cost and quality is a viable software engineering trade-off throughout the life cycle. Therefore, the ability to accurately estimate the cost and quality of software systems is essential to providing reliable software on time and within budget. Software cost models relate the product error rate to the percent of the project labor that is required for independent verification and validation. The criticality of the software determines which cost model is used to estimate the labor required to develop the software. Software quality models yield an expected error discovery rate based on the software size, criticality, software development environment, and the level of competence of the project and developers with respect to the processes being employed.

Rone, Kyle Y.↗

Sensor Needs for Advanced Life Support

Sensors and feedback systems are critical to life support flight systems and life support systems research. New sensor capabilities can allow for new system architectures to be considered, and can facilitate dramatic improvements in system performance. This paper will describe three opportunities for biosensor researchers to develop sensors that will enable life support system improvements. The first opportunity relates to measuring physical, chemical, and biological parameters in the Space Station Water Processing System. Measuring pH, iodine, total organic carbon, microbiological activity, total dissolved solids, or conductivity with a safe, effective, stable, reliable microsensor could benefit the water processing system considerably. Of special interest is a sensor which can monitor biological contamination rapidly. The second opportunity relates to sensing microbiological contamination and water condensation on the surface of large inflatable structures. It is the goal of large inflatable structures used for habitation to take advantage of the large surface area of the structure and reject waste heat passively through the walls of the structure. Too much heat rejection leads to a cold spot with water condensation, and eventually microbiological contamination. A distributed sensor system that can measure temperature, humidity, and microbiological contamination across a large surface would benefit designers of large inflatable habitable structures. The third opportunity relates to sensing microbial bioreactors used for waste water processing and reuse. Microbiological bioreactors offer considerable advantages in weight and power compared to adsorption bed based systems when used for long periods of time. Managing and controlling bioreactors is greatly helped if distributed microsensors measured the biological populations continuously in many locations within the bioreactor. Nitrifying bacteria are of special interest to bioreactor designers, and any sensors that could measure the populations of these types of bacteria would help the control and operation of bioreactors. J

Graf, John C.↗

Calibration of the Geosar Dual Frequency Interferometric SAR

GeoSAR is an airborne, interferometric Synthetic Aperture Radar (INSAR) system for terrain mapping, currently under development by a consortium including NASA's Jet Propulsion Laboratory (JPL), Calgis, Inc., and the California Department of Conservation (CalDOC) with funding provided by the Topographic Engineering Center (TEC) of the U.S. Army Corps of Engineers and the Defense Advanced Research Projects Agency (DARPA). The radar simultaneously maps swaths on both sides of the aircraft at two frequencies, X-Band and P-Band. For the P-Band system, data is collected for two across track interferometric baselines and at the crossed polarization. The aircraft position and attitude are measured using two Honeywell Embedded GPS Inertial Navigation Units (EGI) and an Ashtech Z12 GPS receiver. The mechanical orientation and position of the antennas are actively measured using a Laser Baseline Metrology System (LBMS). In the GeoSAR motion measurement software, these data are optimally combined with data from a nearby ground station using Ashtech PNAV software to produce the position, orientation, and baseline information are used to process the dual frequency radar data. Proper calibration of the GeoSAR system is essential to obtaining digital elevation models (DEMS) with the required sub-meter level planimetric and vertical accuracies. Calibration begins with the determination of the yaw and pitch biases for the two EGI units. Common range delays are determined for each mode, along with differential time and phase delays between channels. Because the antennas are measured by the LBMS, baseline calibration consists primarily of measuring a constant offset between mechanical center and the electrical phase center of the antennas. A phase screen, an offset to the interferometric phase difference which is a function of absolute phase, is applied to the interferometric data to compensate for multipath and leakage. Calibration parameters are calculated for each of the ten processing modes, each of the operational bandwidths (80 and 160 MHZ), and each aircraft altitude. In this talk we will discuss the layout calibration sites, the synthesis of data from multiple flights to improve the calibration, methods for determining time and phase delays, and techniques for determining radiometric and polarimetric quantities. We will describe how calibration quantities are incorporated into the processor and pre-processor. We will demonstrate our techniques applied to GeoSar data and assess the stability and accuracy of the calibration. This will be compared to the modeled performance determined from calibrating the output of a point target simulator. The details of baseline determination and phase screen calculation are covered in related talks.

Chapine, Elaine↗

An operational multispectral scanner for bathymetric surveys - The ABS NORDA scanner

The Naval Ocean Research and Development Activity (NORDA) is developing the Airborne Bathymetric Survey (ABS) system, which will take shallow water depth soundings from a Navy P-3 aircraft. The system combines active and passive sensors to obtain optical measurements of water depth. The ABS NORDA Scanner is the systems passive multispectral scanner whose design goal is to provide 100 percent coverage of the seafloor, to depths of 20 m in average coastal waters. The ABS NORDA Scanner hardware and operational environment is discussed in detail. The optical model providing the basis for depth extraction is reviewed and the proposed data processing routine discussed.

Haimbach, Stephen P.↗

Equilibrium Thermodynamic Properties of Aqueous Solutions of Ionic Liquid 1-Ethyl-3-Methylimidazolium Methanesulfonate [EMIM][MeSO3]

Abstract The ionic liquid 1-ethyl-3-methylimidazolium methanesulfonate ([EMIM][MeSO 3 ]) has been considered as a promising alternative desiccant to triethylene glycol and lithium bromide commonly used in the industry. In this paper, the water activity coefficient of this binary system was measured from 303 K to 363 K with water concentration from 18% to 92%. The interaction energies between the ionic liquid molecules ( $${g}_{22}$$ g 22 ) and between the ionic liquid and water molecules ( $${g}_{12}$$ g 12 ) for the [EMIM][MeSO 3 ]/water binary system were determined from the water activity coefficient data using the Non-Random Two-Liquid (NRTL) model. The magnitude of the interaction energy between the [EMIM][MeSO 3 ] and water molecules ( $${g}_{12}$$ g 12 ) was found to be in the range of 45~49 kJ/mol, which was about 20% larger than that between the water molecules ( $${g}_{11}$$ g 11 ) in the [EMIM][MeSO 3 ]/water system. The large ( $${g}_{12}$$ g 12 ) can explain many observed macroscopic thermodynamic properties such as strong hygroscopicity in the ionic liquid [EMIM][MeSO 3 ]. These interaction energies were used to determine the heat of desorption of the [EMIM][MeSO 3 ]/water system, and the obtained heat of desorption was in good agreement with that calculated from the conventional Clausius-Clapeyron Equation.

42 ENGINEERING↗

Regulation of body fluid volume and electrolyte concentrations in spaceflight

Despite a number of difficulties in performing experiments during weightlessness, a great deal of information has been obtained concerning the effects of spaceflight on the regulation of body fluid and electrolytes. Many paradoxes and questions remain, however. Although body mass, extracellular fluid volume, and plasma volume are reduced during spaceflight and remain so at landing, the changes in total body water are comparatively small. Serum or plasma sodium and osmolality have generally been unchanged or reduced during the spaceflight, and fluid intake is substantially reduced, especially during the first of flight. The diuresis that was predicted to be caused by weightlessness, has only rarely been observed as an increased urine volume. What has been well established by now, is the occurrence of a relative diuresis, where fluid intake decreases more than urine volume does. Urinary excretion of electrolytes has been variable during spaceflight, but retention of fluid and electrolytes at landing has been consistently observed. The glomerular filtration rate was significantly elevated during the SLS missions, and water and electrolyte loading tests have indicated that renal function is altered during readaptation to Earth's gravity. Endocrine control of fluid volumes and electrolyte concentrations may be altered during weightlessness, but levels of hormones in body fluids do not conform to predictions based on early hypotheses. Antidiuretic hormone is not suppressed, though its level is highly variable and its secretion may be affected by space motion sickness and environmental factors. Plasma renin activity and aldosterone are generally elevated at landing, consistent with sodium retention, but inflight levels have been variable. Salt intake may be an important factor influencing the levels of these hormones. The circadian rhythm of cortisol has undoubtedly contributed to its variability, and little is known yet about the influence of spaceflight on circadian rhythms. Atrial natriuretic peptide does not seem to play an important role in the control of natriuresis during spaceflight. Inflight activity of the sympathetic nervous system, assessed by measuring catecholamines and their metabolites and precursors in body fluids, generally seems to be no greater than on Earth, but this system is usually activated at landing. Collaborative experiments on the Mir and the International Space Station should provide more of the data needed from long-term flights, and perhaps help to resolve some of the discrepancies between U.S. and Russian data. The use of alternative methods that are easier to execute during spaceflight, such as collection of saliva instead of blood and urine, should permit more thorough study of circadian rhythms and rapid hormone changes in weightlessness. More investigations of dietary intake of fluid and electrolytes must be performed to understand regulatory processes. Additional hormones that may participate in these processes, such as other natriuretic hormones, should be determined during and after spaceflight. Alterations in body fluid volume and blood electrolyte concentrations during spaceflight have important consequences for readaptation to the 1-G environment. The current assessment of fluid and electrolyte status during weightlessness and at landing and our still incomplete understanding of the processes of adaptation to weightlessness and readaptation to Earth's gravity have resulted in the development of countermeasures that are only partly successful in reducing the postflight orthostatic intolerance experienced by astronauts and cosmonauts. More complete knowledge of these processes can be expected to produce countermeasures that are even more successful, as well as expand our comprehension of the range of adaptability of human physiologic processes.

NASA Discipline Number 18-10↗

A Compact 600 GHz Electronically Tunable Vector Measurement System for Submillimeter Wave Imaging

The design of a complete vector measurement system being tested over 560-635 GHz is presented. The topics include: 1) Current State-of-the-Art in Vector Measurements; 2) Submillimeter Active Imaging Requirements; 3) 600 GHz Vector Measurement System; 4) 450 MHz IF Signal; 5) 450 MHz IF signal @ 1 kHz Res. BW; 6) 450 MHz IF Signal Mixed with Shifted 450 MHz Reference Signal; 7) Reference Signal Offset Generator; 8) Cavity Bandpass Filter; 9) Miniature Multistage Helical Filter; 10) X36 450 MHz Multiplier; 11) 600 GHz Test Setup; 12) 600 GHz Transmit Module; 13) 600 GHz Receive Module; 14) Performance Tests: Amplitude Stability & Dynamic Range; 15) Performance Tests: Phase Stability; 16) Stability at Imaging Bandwidths; 17) Phase Measurement Verification; and 18) The Next Step: Imaging.

phase measurements↗

Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain's ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable and provides imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles. SR using imperceptible stochastic electrical stimulation of the vestibular system (stochastic vestibular stimulation, SVS) applied to normal subjects has shown to improve the degree of association between the weak input periodic signals introduced via venous blood pressure receptors and the heart-rate responses. Also, application of SVS over 24 hours improves the long-term heart-rate dynamics and motor responsiveness as indicated by daytime trunk activity measurements in patients with multi-system atrophy, Parkinson s disease, or both, including patients who were unresponsive to standard therapy for Parkinson s disease. Recent studies conducted at the NASA JSC Neurosciences Laboratories showed that imperceptible SVS, when applied to normal young healthy subjects, leads to significantly improved balance performance during postural disturbances on unstable compliant surfaces. These studies have shown the benefit of SR noise characteristic optimization with imperceptible SVS in the frequency range of 0-30 Hz, and amplitudes of stimulation have ranged from 100 to 400 microamperes.

Bloomberg, Jacob↗