Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerated degradation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An analytical approach to evaluation of space radiation effects on materials for long-life missions

An analytical model was developed which quantifies effects on organic composite matrix materials of high energy electrons and of UV as well as interactions between the two radiations. Literature data on polyethylene were used to construct a degradation kinetics scheme corresponding to an Earth orbit at L=3. Analysis of the model showed that steady state concentrations of radicals put limits on accelerated test conditions. These conclusions were validated by an experimental study on polymethylmethacrylate using UV laser excitation. Relationships for balancing electron and UV radiations to equal acceleration factors are derived. Pulse radiolysis using an electron-beam along with time-resolved spectroscopy is shown to be able to separate primary form secondary reactions. Implications of these reactions to changes in engineering material properties are indicated. The use of mechanistic studies is discussed in the context of general test strategies for evaluating materials for space applications.

Moacanin, J.↗

Stress Testing of Chip Aluminum Polymer Capacitors

Layered aluminum polymer capacitors (APC) may be viable replacements to current chip tantalum capacitors due to their lower ESR, weight, and smaller size. So far, there is a lack of information regarding the reliability of these parts. Available technical literature is mostly related to the effect on humidity. Although APCs have a limited moisture resistance, it may be contained to the level sufficient for space applications. In this work, seven types of commercial APCs manufactured by four vendors and rated to voltages from 6.3 to 35 V were used to evaluate reliability of the parts under environmental stresses and highly accelerated life tests. Characteristics of the parts, including breakdown voltages, the level of anomalous charging currents (ACC), capacitance, DF, ESR and leakage currents were measured in the process of storage at high-temperatures (from 100 to 150 °C) and high humidity at 85 °C. Monitored highly accelerated life tests have been carried out at temperatures of 85 °C and 125 °C and voltages varying from 1.2 to 1.9 times the rated voltage. Degradation processes and reliability of APCs have been analyzed and compared to polymer tantalum capacitors.

Alexander Teverovsky↗

Evaluation of Aluminum Polymer Capacitors for Space Applications

Layered aluminum polymer capacitors (APC) may be viable replacements to currently used chip tantalum capacitors due to their lower ESR, weight, and smaller size. So far, there is a lack of information regarding the reliability of these parts. Available technical literature is mostly related to the effect of humidity. Although APCs have a limited moisture resistance, it may be contained to the level sufficient for space applications. This work analyzes construction and characteristics of seven types of commercial APCs manufactured by four vendors and rated to voltages from 6.3 to 35 V were analyzed. Their reliability under environmental stresses and highly accelerated life tests was assessed in the range of temperatures and voltages to determine reliability acceleration factors. For this purpose, characteristics of the parts, including breakdown voltages, the level of anomalous charging currents (ACC), capacitance, DF, ESR and leakage currents were measured in the process of storage at high-temperatures (from 100 to 150 °C) and high humidity at 85 °C. Monitored highly accelerated life tests have been carried out at temperatures of 85 °C and 125 °C and voltages varying from 1.2 to 1.9 times the rated voltage. Degradation processes and reliability of APCs have been compared to polymer tantalum capacitors.

Alexander A Teverovsky↗

NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test as of 736 kg of Propellant Throughput

The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation solar-electric ion propulsion system with significant enhancements beyond the state-of-the-art NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) ion propulsion system to provide future NASA science missions with enhanced mission capabilities. A Long-Duration Test (LDT) was initiated in June 2005 to validate the thruster service life modeling and to qualify the thruster propellant throughput capability. The thruster has set electric propulsion records for the longest operating duration, highest propellant throughput, and most total impulse demonstrated. At the time of this publication, the NEXT LDT has surpassed 42,100 h of operation, processed more than 736 kg of xenon propellant, and demonstrated greater than 28.1 MN s total impulse. Thruster performance has been steady with negligible degradation. The NEXT thruster design has mitigated several lifetime limiting mechanisms encountered in the NSTAR design, including the NSTAR first failure mode, thereby drastically improving thruster capabilities. Component erosion rates and the progression of the predicted life-limiting erosion mechanism for the thruster compare favorably to pretest predictions based upon semi-empirical ion thruster models used in the thruster service life assessment. Service life model validation has been accomplished by the NEXT LDT. Assuming full-power operation until test article failure, the models and extrapolated erosion data predict penetration of the accelerator grid grooves after more than 45,000 hours of operation while processing over 800 kg of xenon propellant. Thruster failure due to degradation of the accelerator grid structural integrity is expected after

Shastry, Rohit↗

NASA's Evolutionary Xenon Thruster (NEXT) Long-Duration Test as of 736 kg of Propellant Throughput

The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation solar-electric ion propulsion system with significant enhancements beyond the state-of-the-art NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) ion propulsion system to provide future NASA science missions with enhanced mission capabilities. A Long-Duration Test (LDT) was initiated in June 2005 to validate the thruster service life modeling and to qualify the thruster propellant throughput capability. The thruster has set electric propulsion records for the longest operating duration, highest propellant throughput, and most total impulse demonstrated. At the time of this publication, the NEXT LDT has surpassed 42,100 h of operation, processed more than 736 kg of xenon propellant, and demonstrated greater than 28.1 MN s total impulse. Thruster performance has been steady with negligible degradation. The NEXT thruster design has mitigated several lifetime limiting mechanisms encountered in the NSTAR design, including the NSTAR first failure mode, thereby drastically improving thruster capabilities. Component erosion rates and the progression of the predicted life-limiting erosion mechanism for the thruster compare favorably to pretest predictions based upon semi-empirical ion thruster models used in the thruster service life assessment. Service life model validation has been accomplished by the NEXT LDT. Assuming full-power operation until test article failure, the models and extrapolated erosion data predict penetration of the accelerator grid grooves after more than 45,000 hours of operation while processing over 800 kg of xenon propellant. Thruster failure due to degradation of the accelerator grid structural integrity is expected after groove penetration.

Shastry, Rohit↗

Investigation of critical surface degradation effects on coatings and solar cells developed in Germany (S1002)

Various coatings developed in the FRG (i.e., second-surface mirrors with interference filters with and without conductive layers, conductive layers on solar-cell covers, and selective absorber coatings) have been qualified by accelerated tests under simulated space environment conditions. Experiments with coatings and solar cells have shown, however, that the thermo-optical behavior can differ considerably when performed on the ground and in space because of the great difficulty in simulating the space environment realistically. The objective of this experiment is to qualify these coatings under realistic space environment conditions. In addition, the experiment will provide design criteria, techniques, and test methods to insure control of the combined space and spacecraft environment effects, such as contamination, electrical conductance, and optical degradation, on the coatings. Data to be measured include the temperature of the samples, the electrical resistance of the conductive layers of the samples, the short circuit current of the solar-cell modules, and the deposition of contaminants on the samples (using quartz crystal microbalances (QCM's)).

Preuss, L.↗

Accelerating Corrosion in Solar-Cell Tests

In simple electrochemical cell, two silicon solar cells serve as anode and cathode, respectively. Electrolytic medium and voltage between them accelerate corrosion and migration interactions between cell metal contacts and plastic encapsulant. Degradation of metal contacts becomes evident in few hours. Although developed specifically for cells with Ti/Pd/Ag contacts, technique readily adapted to other metal combinations.

Shalaby, H. M.↗

Dual control vibration tests of flight hardware

A vibration retest of a spacecraft flight instrument, the Mars Observer Camera (MOC), was conducted using extremal dual control to automatically limit the shaker force and notch the shaker acceleration at resonances. This was the first application of extremal dual control with flight hardware at JPL. The retest was successful in that the environment was representative of flight plus some margin, the instrument survived without any structural or performance degradation, and the force limiting worked very well. The test set-up, force limiting procedure, and test results are described herein. It is concluded that dual control should be utilized when there is a concern about overtesting in hard-base-drive tests and the instrumentation for force measurement and control is available. Recommendations for improving the implementation of dual control are provided as a result of this first experience.

Scharton, Terry D.↗

Long-term photothermal/humidity testing of photovoltaic module polymer insulations and cover films

The life expectancies of Tedlar and other polymer films considered for use as cover materials in terrestrial photovoltaic (PV) modules were investigated by exposing them for more than 13,000 h on an outdoor test stand and for up to 10,000 h in several accelerated multistress environments. Visual observations and diagnostic analyses of weight and mechanical strength losses were periodically conducted to assess the nature and rate of degradation of mechanical properties and to assess the effects of film thickness and UV stabilizer content. Spectroscopic analyses of pristine and degraded materials linked weight and mechanical property losses to the underlying photothermal/photooxidation chemistry. It is shown that heavy doses of UV stabilizers prolong, while elevated temperatures shorten, the useful life of these materials; humidity plays only a minor role. The most heavily UV-stabilized films are expected to operate usefully in a PV module front-cover application for only five to ten years. The performance of none of the tested films appears consistent with the 20-30 year life goals of the PV industry.

Mon, G.↗

High-Heat-Flux Cyclic Durability of Thermal and Environmental Barrier Coatings

Advanced ceramic thermal and environmental barrier coatings will play an increasingly important role in future gas turbine engines because of their ability to protect the engine components and further raise engine temperatures. For the supersonic vehicles currently envisioned in the NASA fundamental aeronautics program, advanced gas turbine engines will be used to provide high power density thrust during the extended supersonic flight of the aircraft, while meeting stringent low emission requirements. Advanced ceramic coating systems are critical to the performance, life and durability of the hot-section components of the engine systems. In this work, the laser and burner rig based high-heat-flux testing approaches were developed to investigate the coating cyclic response and failure mechanisms under simulated supersonic long-duration cruise mission. The accelerated coating cracking and delamination mechanism under the engine high-heat-flux, and extended supersonic cruise time conditions will be addressed. A coating life prediction framework may be realized by examining the crack initiation and propagation in conjunction with environmental degradation under high-heat-flux test conditions.

Zhu, Dongming↗

A simulator study on information requirements for precision hovering

A fixed base simulator study of an advanced helicopter instrument display utilizing translational acceleration, velocity and position information is reported. The simulation involved piloting a heavy helicopter using the Integrated Trajectory Error Display (ITED) in a precision hover task. The test series explored two basic areas. The effect on hover accuracy of adding acceleration information was of primary concern. Also of interest was the operators' ability to use degraded information derived from less sophisticated sources. The addition of translational acceleration to a display containing velocity and position information did not appear to improve the hover performance significantly. However, displayed acceleration information seemed to increase the damping of the man machine system. Finally, the pilots could use translational information synthesized from attitude and angular acceleration as effectively as perfect acceleration.

Lemons, J. L.↗

Reliability and Engineering of Thin-Film Photovoltaic Modules. Research forum proceedings

A Research Forum on Reliability and Engineering of Thin Film Photovoltaic Modules, under sponsorship of the Jet Propulsion Laboratory's Flat Plate Solar Array (FSA) Project and the U.S. Department of Energy, was held in Washington, D.C., on March 20, 1985. Reliability attribute investigations of amorphous silicon cells, submodules, and modules were the subjects addressed by most of the Forum presentations. Included among the reliability research investigations reported were: Arrhenius-modeled accelerated stress tests on a Si cells, electrochemical corrosion, light induced effects and their potential effects on stability and reliability measurement methods, laser scribing considerations, and determination of degradation rates and mechanisms from both laboratory and outdoor exposure tests.

Ross, R. G., Jr.↗

Performance characteristics of the deep space 1 flight spare ion thruster long duration test, the first 21,300 hours of operation

A long duration test of the DSl flight spare ion thruster (FT2) is presently being conducted at the Jet Propulsion Laboratory. To, date the thruster has accumulated over 23,500 hours of operation, and 190 kg of Xenon propellant, over 230% of the initial design life. The primary objectives of the test include the processing of 200 kg of Xenon propellant, the identification of unknown failure modes, the characterization and drivers of these failure modes, and to measure performance degradation as the thruster wears. The test is fitted with an extensive array of diagnostics to measure engine wear and performance degradation. To date the most notable erosion processes include severe discharge cathode keeper erosion, accelerator grid erosion, reduction in electrical isolation of the neutralizer assembly, and deposit formation within the neutralizer orifice, reducing margin from plume mode. Over the past 23,500 hours of operation, performance degradation has been minimal, and it is anticipated that the above erosion processes will not preclude the thruster from processing over 200 kg of Xenon.

ion thrusters deep space one↗

ATS-F radiant cooler contamination test in a hydrazine thruster exhaust

A test was conducted under simulated space conditions to determine the potential thermal degradation of the ATS-F radiant cooler from any contaminants generated by a 0.44-N(0.1-lbf) hydrazine thruster. The radiant cooler, a 0.44-N(0.1-lbf)hydrazine engine, and an aluminum plate simulating the satellite interface were assembled to simulate their flight configuration. The cooler was provided with platinum sensors for measuring temperature, and its surfaces were instrumented with six quartz crystal microbalance units (QCM) to measure contaminant mass deposits. The complete assembly was tested in the molecular sink vacuum facility (Molsink) at the Jet Propulsion Laboratory. This was the first time that a radiant cooler and a hydrazine engine were tested together in a very-high-vacuum space simulator, and this test was the first successful measurement of detectable deposits from hydrazine rocket engine plumes in a high vacuum. The engine was subjected to an accelerated duty cycle of 1 pulse/min, and after 2-hr of operation, the QCMs began to shift in frequency. The tests continued for several days and, although there was considerable activity in the QCMs, the cooler never experienced thermal degradation.

Chirivella, J. E.↗

Multi-Billion Shot, High-Fluence Exposure of Cr(4+): YAG Passive Q-Switch

NASA's Goddard Space Flight Center is developing the Geoscience Laser Altimeter System (GLAS) employing a diode pumped, Q-Switched, ND:YAG laser operating at 40 Hz repetition rate. To meet the five-year mission lifetime goal, a single transmitter would accumulate over 6.3 billion shots. Cr(4+):YAG is a promising candidate material for passively Q-switching the laser. Historically, the performance of saturable absorbers has degraded over long-duration usage. To measure the multi-billion shot performance of Cr(4+):YAG, a passively Q-switched GLAS-like oscillator was tested at an accelerated repetition rate of 500 Hz. The intracavity fluence was calculated to be approximately 2.5 J/cm(exp 2). The laser was monitored autonomously for 165 days. There was no evidence of change in the material optical properties during the 7.2 billion shot test.. All observed changes in laser operation could be attributed to pump laser diode aging. This is the first demonstration of multi-billion shot exposure testing of Cr(4+):YAG in this pulse energy regime

Stephen, Mark A.↗

Degradation in nickel-cadmium cells studied by impedance measurements

The impedance characteristics of various Ni-Cd cells were measured at different times during accelerated charge/discharge trials to identify characteristics indicative of cell lifetime and cycle history. The tests were performed as part of an attempt to develop nondestructive testing techniques to detect flaws in batteries installed on low-earth orbit satellites. Trials consisted of 60 min charging and 40 min discharging, covering 20, 30, and 40 C temperatures, 20, 35, and 50 percent depth of discharge, and the average cycle life. No correlations were derived between impedance characteristics and cycle life. Other possible techniques for evaluating predictors of battery performance are discussed.

Haak, R.↗

Non-gassing nickel-cadmium battery electrodes and cells: Testing of 25 Ah cells

The testing of 30 practical size, experimental 25 ampere hour cells constructed as part of an earlier negative limited cell development program is discussed. The test results showed that the negative limited cell is a possible means of developing a long-lived secondary cell. The cells were tested for 500 cycles using an accelerated regime approximating a 90-minute orbit period. Three groups of ten cells were tested at 0,25, and 40 C. The cycle data showed that the negative limited cells had higher degradation rates at the higher operating temperatures. At the conclusion of 500 cycles, the three groups had average capacities of 16.83, 12.74, and 5.71 ampere hours for testing at 0, 25, 40 C, respectively. The conditioning capacities of these cells was in the 25 ampere hours range. The internal cell pressures of the three groups was also temperature dependent and was, in general, in the 2 psig range during the course of the test program. No periodic variation of the internal pressure with the state-of-charge was observed except with some cells tested at 40 C.

Luksha, E.↗

Flight simulation testing of advanced composites for supersonic cruise aircraft applications

The goal of this program is to characterize advanced composite systems before and after exposures to simulated supersonic cruise environments for real times of up to 50,000 hours. Fatigue data for specimens tested at various temperatures and stress ratios are presented. The changes in properties and the degradation mechanisms during high temperature aging are discussed and illustrated using metallographic and fractographic techniques. Initial results of long term flight simulation tests are presented and compared with wearout model predictions based on accelerated flight simulation exposures.

Haskins, J. F.↗