Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Xe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Search for double-beta decay of $$\mathrm {^{130}Te}$$ to the $$0^+$$ states of $$\mathrm {^{130}Xe}$$ with CUORE

Abstract The CUORE experiment is a large bolometric array searching for the lepton number violating neutrino-less double beta decay ( $$0\nu \beta \beta $$ 0 ν β β ) in the isotope $$\mathrm {^{130}Te}$$ 130 Te . In this work we present the latest results on two searches for the double beta decay (DBD) of $$\mathrm {^{130}Te}$$ 130 Te to the first $$0^{+}_2$$ 0 2 + excited state of $$\mathrm {^{130}Xe}$$ 130 Xe : the $$0\nu \beta \beta $$ 0 ν β β decay and the Standard Model-allowed two-neutrinos double beta decay ( $$2\nu \beta \beta $$ 2 ν β β ). Both searches are based on a 372.5 kg $$\times $$ × yr TeO $$_2$$ 2 exposure. The de-excitation gamma rays emitted by the excited Xe nucleus in the final state yield a unique signature, which can be searched for with low background by studying coincident events in two or more bolometers. The closely packed arrangement of the CUORE crystals constitutes a significant advantage in this regard. The median limit setting sensitivities at 90% Credible Interval (C.I.) of the given searches were estimated as $$\mathrm {S^{0\nu }_{1/2} = 5.6 \times 10^{24} \, \mathrm {yr}}$$ S 1 / 2 0 ν = 5.6 × 10 24 yr for the $${0\nu \beta \beta }$$ 0 ν β β decay and $$\mathrm {S^{2\nu }_{1/2} = 2.1 \times 10^{24} \, \mathrm {yr}}$$ S 1 / 2 2 ν = 2.1 × 10 24 yr for the $${2\nu \beta \beta }$$ 2 ν β β decay. No significant evidence for either of the decay modes was observed and a Bayesian lower bound at $$90\%$$ 90 % C.I. on the decay half lives is obtained as: $$\mathrm {(T_{1/2})^{0\nu }_{0^+_2} > 5.9 \times 10^{24} \, \mathrm {yr}}$$ ( T 1 / 2 ) 0 2 + 0 ν > 5.9 × 10 24 yr for the $$0\nu \beta \beta $$ 0 ν β β mode and $$\mathrm {(T_{1/2})^{2\nu }_{0^+_2} > 1.3 \times 10^{24} \, \mathrm {yr}}$$ ( T 1 / 2 ) 0 2 + 2 ν > 1.3 × 10 24 yr for the $$2\nu \beta \beta $$ 2 ν β β mode. These represent the most stringent limits on the DBD of $$^{130}$$ 130 Te to excited states and improve by a factor $$\sim 5$$ ∼ 5 the previous results on this process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monitoring Noble Gases (Xe and Kr) and Aerosols (Cs and Rb) in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy (LIBS)

In this study with surrogate materials we show that laser-induced breakdown spectroscopy (LIBS) is a robust tool with promising capability toward monitoring gaseous (Xe and Kr) and aerosol (Cs and Rb) species in an off-gas stream from a molten salt reactor (MSR). MSRs will continually evolve fission products into the cover gas flowing across the reactor headspace. The cover gas entrains Xe and Kr gases, along with aerosol particles, before passing into an off-gas treatment system. Univariate models of Xe and Kr peaks showed a strong correlation to concentration indicated by their coefficients of determination of 0.983 and 0.997, respectively. Multivariate models were built for all four analytes using partial least squares regression coupled with preprocessing steps including normalization, trimming, and/or genetic algorithm derived filters. The models were evaluated by predicting the concentrations of the analytes in four validation samples, in which all calibration models were successfully validated at a confidence interval of 99.9%. Finally, pressure controllers were used to regulate the mass flow rate of Kr flowing into the measurement cell in sinusoidal and stepwise waveforms to test the real-time monitoring capabilities of the regression models. Both univariate and partial least squares Kr models were able to successfully quantify the gas concentration in the real-time evaluation. The root mean squared error of prediction (RMSEP) values for these real-time tests were calculated to be 0.051, 0.060, and 0.121 mol% demonstrating the measurement systems’ capability to perform online monitoring with acceptable accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Accelerated 133 Xe Quantification in Samples Containing Significant 133 mXe

The quantification of 133 Xe in the presence of its mother radionuclide 133 mXe requires the full quantification of both to perform the ingrowth correction for 133 Xe. Due to the nature of both of these radionuclides, the 133 mXe requires significantly more time to quantify by High Purity Germanium (HPGe) detectors due to lower production yields, lower gamma emission probabilities, and lower detection efficiencies. This work shows that 133 Xe and 133 mXe quantification can be accelerated by measuring the 133m:133 activity ratio for a large batch of material and applying this activity ratio to assays of lower activity subsamples of the same batch of material. Included in this report are derivations of the required decay correction equations, and experiments using actual samples to validate the performance of these equations. A detector calibration method is also shown that leverages this method as an alternative to existing calibration methods for 133 mXe quantification.

133mXe↗

Ultrafast Laser-Excited Optical Emission of Xe under Loose-Focusing Conditions

The optical filament-based radioxenon sensing can potentially overcome the constraints of conventional detection techniques that are relevant for nuclear security applications. This study investigates the spectral signatures of pure xenon (Xe) when excited by ultrafast laser filaments at near-atmosphericpressure and in short and loose-focusing conditions. The two focusing conditions lead to laser intensity differences of several orders of magnitude and different plasma transient behavior. The gaseous sample was excited at atmospheric pressure using ∼7 mJ pulses with a 35 fs pulse duration at 800 nm wavelength. The optical signatures were studied by time-resolved spectrometry and imaging in orthogonal light collection configurations in the ∼400 nm (VIS) and ∼800 nm (NIR) spectral regions. The most prominent spectral lines of atomic Xe are observable in both focusing conditions. An on-axis light collection from an atmospheric air–Xe plasma mixture demonstrates the potential of femtosecond filamentation for the remote sensing of noble gases.

47 OTHER INSTRUMENTATION↗

Rate constants for the deactivation of O/1D/ by Xe, Kr, and Ar over the range 110-330 K

The rate constants for the deactivation of O(1D) by Xe, Kr, and Ar were measured over the range 110-330 K. Only Xe had a significant temperature dependence. Its Arrhenius expression is (8.5 + or - 1.7) times 10 to the -11th power exp(-103 + or - 52)/RT cu cm/molecule-sec. The rate constants for Kr and Ar are (6.4 + or - 1.3) times 10 to the -12th power and (5.0 + or - 1.5) times 10 to the -13th power cu cm/molecule-sec, respectively. The observed trend in deactivation efficiency, Xe (greatest), Kr, Ar (least), and the observed temperature effects support the results and the spin-orbit interaction mechanism for deactivation given by Husain and co-workers.

Davidson, J. A.↗

Gain measurements of the Ca-Xe charge exchange system

Charge-exchange-pumped Ca(+) was studied for possible positive laser gain at 370.6 and 315.9 nm using an Xe MPD arc as the Xe(+) source. The present paper describes the MPD arc, the calcium injection system, the diagnostics for gain, and spontaneous emission measurements and results. No positive gain measurements were observed. A small Xe-Ca charge exchange cross section compared to He-metal laser systems charge exchange cross sections is the most probable reason why the result was negative.

Michels, C. J.↗

Proportional retention of I and radiogenic Xe-129 in preheated Allende

In order to study the effects of heat loss and redistribution of iodine and xenon on the I-Xe age, the iodine-xenon dating technique was applied to a bulk sample of the Allende chondrite and a similar sample preheated to 900 C prior to the irradiation. Little iodine or Xe-129 were lost from the high-temperature fractions of the preheated sample, and the high-temperature isochron was fully preserved. The amounts of I and radiogenic Xe-129 retained by the preheated sample were nearly proportional in those temperature fractions (900-1150 C) where most I and radiogenic X-129 were lost. However, the intermediate-temperature isochron was modified, resulting in an apparent isochron which would predate the high-temperature isochron by 6.7 + or - 1.1 m.y.

Rison, W.↗

Shock disturbance of the I-Xe system

Three separate samples of the meteorite Bjurbole were artificially shocked at pressures of 70 kb, 200 kb, and 400 kb. Analysis of xenon released in stepwise heating shows that the I-Xe system of the 400 kb sample is substantially altered by the shock loading, and it is no longer possible to infer an age or trapped xenon composition for that sample. The 200-kb and 70-kb samples display isotopic structures progressively less altered demonstrating the gradations in shock disturbance likely to be found in natural systems. Interpretations of the I-Xe and Ar-40-Ar-39 systems for several naturally shocked meteorites are also presented. New data for Arapahoe do not confirm the previously reported age and trapped xenon composition, demonstrating instead that its I-Xe structure has been strongly disturbed by shock.

Caffee, M. W.↗

I-Pu-Xe dating and the relative ages of the earth and moon

The ages of the earth and moon as determined by various chronometric systems are discussed with primary emphasis placed on the development of an I-Pu-Xe chronometer. Data on excess fission xenon are reviewed with attention given to the strengths and weaknesses of the assumptions required for lunar I-Pu-Xe chronometry. Using I-Pu-Xe dating, it is estimated that the retention of excess fission xenon in lunar samples began no more than 63 + or - 42 m.y. after the time of primitive meteorite formation.

Swindle, T. D.↗

I-Xe structure of ILAFEGH 009 and shallowater: Evidence for early formation and rapid cooling of impact-derived enstatite meteorites

Enstatite meteorites have proven to be ideal samples for past studies of the I-Xe system. This work focuses on two enstatite meteorites that were formed by impact processes. Ilafegh 009 is a clast-free impact melt rock from the EL chondrite parent body. The Shallowater aubrite likely formed when a fully molten planetesimal collided with a solid planetesimal, mixing fragments of the solid planetesimal into the enstatite mantle of the molten planetesimal. A complex three-stage cooling history resulted from this mixing and later break-up and reassembly of the parent body. The present study indicates that the I-Xe structure of these two meteorites resulted from in situ decay of live I-129 and that both experienced xenon closure of the iodine host phase at approximately the same time. I-Xe cooling rates are consistent with the cooling rates derived from mineralogic and petrologic studies of these objects. The similarities in ages suggest that the region of the nebula in which enstatite parent bodies formed must have experienced an intense early bombardment.

Kehm, K.↗

Ar-Ar and I-Xe Ages and the Thermal History of IAB Meteorites

Studies of several samples of the large Caddo County IAB iron meteorite reveal andesitic material, enriched in Si, Na, Al and Ca, which is essentially unique among meteorites. This material is believed to have formed from a chondritic source by partial melting and to have further segregated by grain coarsening. Such an origin implies extended metamorphism of the IAB parent body. New Ar-39- Ar-40 ages for silicate from three different Caddo samples are consistent with a common age of 4.50-4.51 Gyr ago. Less well defined Ar-Ar degassing ages for inclusions from two other IABs, EET8333 and Udei Station, are approx.4.32 Gyr, whereas the age for Campo del Cielo varies considerably over approx.3.23-4.56 Gyr. New I-129-Xe-129 ages for Caddo County and EET8333 are 4557.9+/-0.1 Myr and 4557-4560 Myr, respectively, relative to an age of 4562.3 Myr for Shallowater. Considering all reported Ar-Ar degassing ages for IABs and related winonaites, the range is approx.4.32-4.53 Gyr, but several IABs give similar Ar ages of 4.50-4.52 Gyr. We interpret these older Ar ages to represent cooling after the time of last significant metamorphism on the parent body, and the younger ages to represent later 40Ar diffusion loss. The older Ar-Ar ages for IABs are similar to Sm-Nd and Rb-Sr isochron ages reported in the literature for Caddo County. Considering the possibility that IAB parent body formation was followed by impact disruption, reassembly, and metamorphism (e.g., Benedix et al. 2000), the Ar-Ar ages and IAB cooling rates deduced from Ni concentration profiles in IAB metal (Herpfer et al., 1994) are consistent if the time of the post-assembly metamorphism was as late as approx.4.53 Gyr ago. However, I-Xe ages reported for some IABs define much older ages of approx.4558-4566 Myr, which cannot easily be reconciled with the much younger Ar-Ar and Sm-Nd ages. An explanation for the difference in radiometric ages of IABs may reside in combinations of the following: a) I-Xe ages have very high closure temperatures and were not reset during metamorphism approx.4.53 Gyr ago; b) a bias exists in the 40K decay constants which makes these Ar-Ar ages approx.30 Myr too young; c) the reported Sm-Nd and Rb-Sr ages for Caddo are in error by amounts equal to or exceeding their reported 2-sigma uncertainties; and d) about 30 Myr after the initial heating that produced differentiation of Caddo silicate and mixing of silicate and metal, a mild metamorphism of the IAB parent body reset the Ar-Ar ages.

Bogard, Donald D.↗

Long-Duration Wear Testing of the ASTRAEUS Thruster, Phase I: 50 kg Xe Throughput

The thruster component of the Ascendant Sub-kW Transcelestial Electric Propulsion System successfully completed a propellant throughput demonstration of 50 kg Xe. The thruster was operated for a total of 3,287 h, of which 97.9% was spent at 300 V – 1000 W, and generated 790 kN-s of total impulse. Thrust, telemetry, and temperature measurements periodically recorded at four operating conditions spanning 200 – 500 V and 200 – 1000 W revealed constant performance across the full test duration. High-fidelity plasma simulations of the erosion of the thruster’s downstream faces suggest a theoretical lifetime capability of >30 kh, corresponding to propellant throughput of >450 kg Xe and a total impulse of >7 MNs, at the 300 V – 1000 W operating condition. The test was voluntarily paused after 50 kg Xe throughput to take these erosion measurements before the test was resumed at a different operating condition.

Goebel, Dan↗

Photoionization of Xe 5s: angular distribution and Wigner time delay in the vicinity of the second Cooper minimum

We report the angular distribution and photoionization Wigner time delay of Xe 5s photoelectrons are studied in the region of the second Cooper minimum (SCM) using (i) the relativistic multiconfiguration Tamm–Dancoff approximation, (ii) the relativistic-random-phase approximation (RRPA) and (iii) the RRPA-with-relaxation to demonstrate how differing treatments of correlation, and the relativistic interactions, affect the results. The results of the three methods are compared with each other and with available experimental data. The comparison reveals the importance of electron correlations for which a multiconfiguration description of the initial state is essential. The spin-resolved and spin-averaged photoionization time delay results show important signatures in the region of the SCM in the Xe 5s photoionization cross-section.

74 ATOMIC AND MOLECULAR PHYSICS↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Materials Data on Xe by Materials Project

Xe is beta Polonium-like structured and crystallizes in the trigonal R-3m space group. The structure is zero-dimensional and consists of three xenon molecules. Xe is bonded in a 1-coordinate geometry to atoms.

36 MATERIALS SCIENCE↗

Materials Data on Xe by Materials Project

Xe is Magnesium structured and crystallizes in the hexagonal P6_3/mmc space group. The structure is zero-dimensional and consists of two xenon molecules. Xe is bonded in a 1-coordinate geometry to atoms.

36 MATERIALS SCIENCE↗

Materials Data on Xe by Materials Project

Xe is Copper structured and crystallizes in the cubic Fm-3m space group. The structure is zero-dimensional and consists of four xenon molecules. Xe is bonded in a 1-coordinate geometry to atoms.

36 MATERIALS SCIENCE↗

Materials Data on Xe by Materials Project

Xe is Copper structured and crystallizes in the trigonal R-3m space group. The structure is zero-dimensional and consists of three xenon molecules. Xe is bonded in a 1-coordinate geometry to atoms.

36 MATERIALS SCIENCE↗