Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X-ray instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Apollo 6, Anomaly Report No. 6: Abnormal Structural Performance During Launch Phase

Approximately 2 minutes 13 seconds after lift-off of the Apollo 6 mission, abrupt changes of strain, vibration, and acceleration measurements were indicated in the S-IVB, instrument unit, adapter, lunar module, and command and service modules; photographs showed objects coming from the area of the adapter. The adapter, however, continued to sustain the required loads with no impairment of the mission. The investigation was first focused upon the understanding of the coupled vibration modes and characteristics of the launch vehicle and spacecraft.' Extensive test programs were conducted. It was eventually concluded that the adapter failure was not caused by vibration. Extensive study of the airborne photography and other evidence indicated that a large area of the adapter had lost inner facesheet from the honeycomb sandwich panels. Loads and stresses resulting from vibration were determined to be insufficient to initiate such a failure. The investigation was then directed toward determining the range of pressures that could have been trapped in the Apollo 6 adapter sandwich panels, and toward determining the tolerance of the panels to withstand pressure with various degrees of flaws such as adhesive voids and facesheet dents. The degradation effects of moisture and heat exposure on the adhesive strength were also studied and tested. These tests and analyses led to the conclusion that pressure internal to the sandwich panels could have caused the failure, if a large flaw existed. The pressure buildup would have been caused by aerodynamic heating effects on air and moisture trapped in the panel. The probable cause of the failure was found in the original ultrasonic inspection scan record of the affected adapter panel. In the center of the region where the adapter failed, horizontally along the station 709 panel splice, the record contained two thick anomalous lines extending several feet. Without an X-ray record of this region, the significance of this particular scan record cannot be fully understood. However, since all other evidence had indicated that the adhesive had to be weakened in a rather large area to initiate the failure, the investigation was focused intently upon the station 709 splices of other adapters. Sufficient information was developed to verify that deficient assembly techniques have consistently resulted in abnormalities in the structure at this station. These abnormalities were identified in adapters 12, 13, 14, 15, and 16. Before the splice abnormalities were pinpointed, corrective action was taken to reduce pressure "buildup in the honeycomb panels and to reduce heat degrading effects on the adhesive. This was done by drilling vent holes in the inner facesheet and covering the outer facesheet with cork. The adapters having identified abnormalities in the station 709 splice are being repaired, and the contractor is investigating ways of avoiding these -abnormalities in panels yet to be bonded.

Source record↗

Measurement of the degree of anisotropy of the cosmic radiation using the IMP space vehicle

The detector and data reduction techniques used in connection with the cosmic ray experiments designed for and flown on Explorer 34 and 41 satellites are described. A history of the program development and the present status of data processing are briefly summarized. The instrument to measure the anisotropy and energy spectra of cosmic ray electrons and protons, and X-rays of solar and galactic origin is discussed. The main characteristics of the detectors and the stability during 23 months of operation are described. The method of analysis of the angular distribution of solar cosmic ray particles in the ecliptic plane is given. It is shown that the anisotropy of low energy particles of solar origin decreases sharply to a very small value when the satellite penetrates the magnetosphere.

Palmeira, R. A. R.↗

A Bragg spectrometer for stellar X-ray astronomy.

Poor energy resolution and the steeply varying continuum spectrum make it impossible to obtain with proportional counters an unambiguous identification of certain emission features of Sco X-1. For this reason a Bragg crystal spectrometer was constructed. The instrument, flown successfully aboard an Aerobee-170 rocket, scanned the spectral range from 2.4 to 2.9 keV. The spectrometer consists of two large reflecting crystals of synthetic graphite. The results obtained during the flight of the instrument clearly indicate that the Bragg method can yield much higher sensitivity to line emission than can proportional counter methods.

Kestenbaum, H.↗

Apollo 15 orbital science summary.

In this paper, summary results of the Apollo 15 orbital science payload are given, and some quick-look results of Apollo 16 are discussed. Geochemical instruments, consisting of gamma-ray, X-ray, and alpha particle spectrometers, have provided a chemical map of the lunar surface flown over by Apollo 15. The Laser Altimeter and frontside gravity data have shown some unexpected results with regard to the lunar shape, and provided new basis for understanding lunar mascons. A magnetometer, aboard the small subsatellite, has located magnetic anomalies principally on the lunar farside, and has shown that the small lunar magnetic field is smoother on the frontside than on the back. The mass spectrometer, in orbit aboard the Command and Service Modules, has measured unexpectedly large populations of molecules at orbital altitude (110 km), mostly due to spacecraft contamination. Two major camera systems have provided the first systematic metric quality photography and concurrent high resolution stereo coverage of the lunar surface.

Esenwein, G. F.↗

A graphite crystal polarimeter for stellar X-ray astronomy.

The first crystal X-ray polarimeter to be used for X-ray astronomy is described. Polarization is measured by modulation of the X rays diffracted at an average 45 deg glancing angle from large, curved graphite crystal panels as these rotate about an axis parallel to the incident X-ray flux. Arrangement of the crystal panels, the design of the detector, and the signal-processing circuitry were optimized to minimize systematic effects produced by off-axis pointing of the rocket and cosmic ray induced events. The in-flight performance of the instrument in relation to the observed background signal is discussed.

Weisskopf, M. C.↗

The space shuttle payload planning working groups. Volume 3: High energy astrophysics

The findings of the High Energy Astrophysics working group of the space shuttle payload planning activity are presented. The objectives to be accomplished during space shuttle missions are defined as: (1) X-ray astronomy, (2) hard X-ray and gamma ray astronomy, and (3) cosmic ray astronomy. The instruments and test equipment required to accomplish the mission are identified. Recommendations for managing the installation of the equipment and conducting the missions are included.

Source record↗

Conical focusing crystal spectrometers for cosmic X-ray astronomy

A crystal spectrometer for rocket and satellite experiments is described. Parallel X rays from a stellar object are reflected at constant angle by Bragg crystals arranged around the sector of a cone so that a single wavelength is brought to a focus onto the axis of the cone. The aberrations produced when this array is tilted to change the wavelength are considered. It is shown that these are minimized by moving cone and detector in a nearly theta to two-theta motion and by using a small-angle sector. In a specific design for a satellite instrument using LiF crystal to observe a spectral region including the iron lines at 1.9 A, a spectral resolution of 3 mA over a spectral range of 1.6-2.1 A can be obtained, with the cosmic-ray background rate, and hence the time to detect a weak line decreased by a factor 80 compared to a flat crystal spectrometer. Examples of performance for a low energy rocket experiment are also given.

Woodgate, B. E.↗

The UCSD/MIT hard X-ray and low energy gamma ray experiment for HEAO-A

An HEAO-A spacecraft is described which is scheduled for launch in April 1977 to survey the sky in the 0.15 keV to 10 MeV range of X-rays with improved sensitivity and angular resolution. The spectral and time variations of discrete sources, and the spectrum and isotropy of the diffuse component will be measured. A hard X-ray and low energy gamma ray experiment is described which will use as an array of seven (NaI)(Tl)/CsI(Na) phoswich detectors and eight large CsI(Na) shields. Detector events are pulse-height analyzed with a selectable time resolution of 0.1, 0.005, or 0.00002 sec. The instrument background is expected to be comprised of approximately equal parts of diffuse gamma rays entering the aperture, radioactive decay of spallation products, and gamma ray leakage through the shields. Detailed background predictions are presented, and sensitivity estimates indicate that the Crab nebula should be detected up to approximately 5 MeV. Approximate 1% isotropy limits for the diffuse component of cosmic gamma rays should be achieved, and its spectrum measured with improved precision.

Matteson, J. L.↗

Astronomy satellites in the U.S. program

The Orbiting Astronomical Observatory (OAO) series demonstrated that necessary thermal control systems and high pointing stability are feasible on astronomical satellites. A geosynchronous International Ultraviolet Explorer (IUE) is being planned by the US, UK, and ESRO for stellar spectroscopy. High Energy Astronomy Observatories, HEAO-A B, and C, will concentrate on stellar X-ray objects, cosmic ray physics, and gamma ray astronomy. A Shuttle-compatible Solar Maximum Mission (SMM) is planned for studying solar flares and flare related phenomena during the next solar maximum. Now in the instrumentation definition stage is the Large Space Telescope (LST), to provide higher resolution and sensitivity, larger wavelength range (from ultraviolet to far infrared), and higher time resolution than ground-based telescopes.

Aucremanne, M. J.↗