Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Waveform Averaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Satellite interferometric measurements of auroral kilometric radiation

The first satellite interferometric measurements of auroral kilometric radiation were performed by cross-correlating the waveforms detected by the ISEE 1 and ISEE 2 spacecraft. High correlations were found for all projected baselines, with little or no tendency to decrease even for the longest baselines. For incoherent radiation, the correlation as a function of the baseline is the Fourier transform of the source brightness distribution, implying an average source region diameter for all of the bursts analyzed of less than about 10 km. For such small source diameters, the required growth rates are too large to be explained by existing incoherent theories, strongly indicating that the radiation must be coherent. For coherent radiation, an upper limit to the source region diameter can be inferred instead from the angular width of the radiation pattern. The angular width of the radiation pattern must be at least 2.5 deg, implying that the diameter of the source must be less than about 20 km.

Baumback, M. M.↗

Effect of positive pulse charge waveforms on cycle life of nickel-zinc cells

Five amp-hour nickel-zinc cells were life cycled to evaluate four different charge methods. Three of the four waveforms investigated were 120 Hz full wave rectified sinusoidal (FWRS), 120 Hz silicon controlled rectified (SCR), and 1 kHz square wave (SW). The fourth, a constant current method, was used as a baseline of comparison. Three sealed Ni-Zn cells connected in series were cycled. Each series string was charged at an average c/20 rate, and discharged at a c/2.5 rate to a 75% rated depth.

Smithrick, J. J.↗

Multiple Scattering Theory for Modeling Sonic Booms in Atmospheric Turbulence

Sonic booms are often modeled using Burgers equations accounting for dominant propagation effects. Scattering effects of turbulence, however, have not been incorporated into such equations, although these effects are ubiquitous in measured sonic booms. This paper formulates the mean scattering effects, including backscattering, using multiple scattering theory and ensemble averaging. It obtains an acousto-turbulence interaction energy representing the interaction of an acoustic wave field with a turbulence field. The interaction energy gives rise to a scattering wavenumber, a complex-valued correction to the free-space wavenumber. The scattering wavenumber leads to a dispersion and attenuation of the mean waveform due to backscattering, and can be obtained from a derived exact solution. An existing Burgers equation is extended to include the scattering effects of turbulence as an additional linear term. Numerical simulations of an N-wave and a low boom show that the mean scattering effects lead to shock thickening in the mean waveforms as well as reduce the peak amplitudes and total energy contents. The energy reduction is less severe in the low boom than in the N-wave and is dependent on the variance, correlation length, and thickness of the turbulence field.

sonic booms↗

Acoustic Characterization of the NASA Langley 14- by 22-Foot Subsonic Tunnel Using Single-Microphone Analysis Techniques

An experimental campaign was conducted to assess recent acoustic modifications to the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel. This effort was undertaken in preparation for future rotorcraft, Advanced Air Mobility, and airframe noise acoustic tests. The tunnel is a closed circuit and typically operates in an open-jet configuration for acoustic studies. A vertical linear array of microphones and a phased array were placed on traverses outside of the core flow. Pole-mounted acoustic sources with known waveforms were used to identify reflective surfaces under static conditions with no tunnel flow. A similar process was replicated with more compact sources in an aerodynamic fairing for flow speeds up to Mach 0.16. This enabled investigation of the test section core flow and bounding shear layer impacts on the acoustic measurements. Periodic averaging was employed and was shown to be capable of isolating periodic acoustic signals even for poor signal-to-noise ratio conditions. Benefits and limitations of single-microphone processing methods are identified. A companion paper utilizes a phased array in an effort to address the identified limitations to more traditional single-microphone data collection.

Acoustic Characterization↗

Acoustic Characterization of the NASA Langley 14- by 22-Foot Subsonic Tunnel Using Single-Microphone Analysis Techniques

An experimental campaign was conducted to assess recent acoustic modifications to the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel. This effort was undertaken in preparation for future rotorcraft, Advanced Air Mobility, and airframe noise acoustic tests. The tunnel is a closed circuit and typically operates in an open-jet configuration for acoustic studies. A vertical linear array of microphones and a phased array were placed on traverses outside of the core flow. Pole-mounted acoustic sources with known waveforms were used to identify reflective surfaces under static conditions with no tunnel flow. A similar process was replicated with more compact sources in an aerodynamic fairing for flow speeds up to Mach 0.16. This enabled investigation of the test section core flow and bounding shear layer impacts on the acoustic measurements. Periodic averaging was employed and was shown to be capable of isolating periodic acoustic signals even for poor signal-to-noise ratio conditions. Benefits and limitations of single-microphone processing methods are identified. A companion paper utilizes a phased array in an effort to address the identified limitations to more traditional single-microphone data collection.

Acoustic Characterization↗

Receiver design, performance analysis, and evaluation for space-borne laser altimeters and space-to-space laser ranging systems

Laser altimeters measure the time of flight of the laser pulses to determine the range of the target. The simplest altimeter receiver consists of a photodetector followed by a leading edge detector. A time interval unit (TIU) measures the time from the transmitted laser pulse to the leading edge of the received pulse as it crosses a preset threshold. However, the ranging error of this simple detection scheme depends on the received, pulse amplitude, pulse shape, and the threshold. In practice, the pulse shape and the amplitude are determined by the target target characteristics which has to be assumed unknown prior to the measurement. The ranging error can be improved if one also measures the pulse width and use the average of the leading and trailing edges (half pulse width) as the pulse arrival time. The ranging error becomes independent of the received pulse amplitude and the pulse width as long as the pulse shape is symmetric. The pulse width also gives the slope of the target. The ultimate detection scheme is to digitize the received waveform and calculate the centroid as the pulse arrival time. The centroid detection always gives unbiased measurement even for asymmetric pulses. In this report, we analyze the laser altimeter ranging errors for these three detection schemes using the Mars Orbital Laser Altimeter (MOLA) as an example.

Davidson, Frederic M.↗

Direct measurement of capillary blood pressure in the human lip

In this study, we developed and tested a new procedure for measuring microcirculatory blood pressures above heart level in humans. Capillary and postcapillary venule blood pressures were measured directly in 13 human subjects by use of the servonulling micropressure technique adapted for micropuncture of lip capillaries. Pressure waveforms were recorded in 40 separate capillary vessels and 14 separate postcapillary venules over periods ranging from 5 to 64 s. Localization and determination of capillary and postcapillary vessels were ascertained anatomically before pressure measurements. Capillary pressure was 33.2 +/- 1.5 (SE) mm Hg in lips of subjects seated upright. Repeated micropunctures of the same vessel gave an average coefficient of variation of 0.072. Postcapillary venule pressure was 18.9 +/- 1.6 mm Hg. This procedure produces a direct and reproducible means of measuring microvascular blood pressures in a vascular bed above heart level in humans.

Parazynski, S. E.↗

Anti-Phase Vortex Reduction Control for Rotor Noise Suppression

An investigation is conducted in 2019 under the NASA Ames Center Innovation Funds (CIF) project entitled “Anti-Phase Vortex Reduction Control for Rotor Noise Suppression“ to experimentally validate an anti-phase rotor noise suppression concept. The first objective of the investigation is to conduct computational fluid dynamics (CFD) simulations to investigate the noise characteristics of several anti-phase rotor designs. The second objective is to conduct a series of acoustic tests of anti-phase rotors in an anechoic chamber at Pennsylvania State University (PSU) to evaluate the merit of the anti-phase rotor concept. The CFD investigation seeks to optimize the anti-phase alternating trailing edge patterns for rotor noise suppression. The design objective is to maximize the noise reduction while maintaining the aerodynamic thrust. The investigation is performed using a three-dimensional (3D) Unsteady Reynolds-Averaged Navier-Stokes (URANS) commercial solver STAR-CCM+ together with the Ffowcs-Williams and Hawkings (FW-H) formula to obtain the aerodynamic thrust and far-field noise level. An acoustic study is conducted for 13 anti-phase design candidates based on a proprietary rotor design. The CAD geometry of the rotor is furnished by PSU. These design candidates include different alternating trailing edge (TE) waveforms, TE segment lengths, TE deflection amplitudes, and transition characteristics. The best design candidate among those explored is an anti-phase rotor that has a four-period TE waveform which results in a reduction in far-field noise level of 2.1 dB in the hover condition and a reduction of 1.1 dB in the forward flight condition at 9.7 m/s. A further acoustic study is conducted for a different rotor manufactured by APC. Five APC rotor design candidates are simulated. The best anti-phase design candidate for the APC rotor results in a reduction in far-field noise level of 4.0 dB in the hover condition. An in-phase design candidate is also studied. This in-phase design provides a noise reduction of 2.5 dB. A series of acoustic experiments in the PSU anechoic chamber have been conducted in July 2019 and October 2019. Both anti-phase and in-phase rotors fabricated for the left-hand and right-hand rotations are tested. In the hover condition, all the rotors do not provide sufficient evidence of improved acoustic performance. However, the experimental data in the hover condition are deemed to be inconclusive due to the flow recirculation in the anechoic chamber caused by the rotor downwash. In the forward flight condition at 9.7 m/s, the anti-phase right-hand rotor produces a noise reduction by as much as 6.5 dB in the frequency range of 2000-4000 Hz, while the in-phase right-hand rotor produces a noise reduction by as much as 5 dB in the same frequency range. Both the anti-phase and in-phase left hand rotors offer no evidence of noise reduction. The difference in the acoustic performance of the left-hand and right-hand rotors could be explained by the location of the microphone array which is placed to the left side of the rotors. This microphone array location could create a bias in the sound pressure level in favor of the right-hand rotor. Using the average noise reduction values, the anti-phase 4H rotor could offer a noise reduction by as much as 3.25 dB while the in-phase 4I rotor could produce up to a 2.5 dB noise reduction. Both the computational and experimental results have provided sufficient evidence to support the noise suppression capability of the proposed anti-phase rotor concepts.

Rotor noise↗

Advanced Water Vapor Lidar Detection System

In the present water vapor lidar system, the detected signal is sent over long cables to a waveform digitizer in a CAMAC crate. This has the disadvantage of transmitting analog signals for a relatively long distance, which is subjected to pickup noise, leading to a decrease in the signal to noise ratio. Generally, errors in the measurement of water vapor with the DIAL method arise from both random and systematic sources. Systematic errors in DIAL measurements are caused by both atmospheric and instrumentation effects. The selection of the on-line alexandrite laser with a narrow linewidth, suitable intensity and high spectral purity, and its operation at the center of the water vapor lines, ensures minimum influence in the DIAL measurement that are caused by the laser spectral distribution and avoid system overloads. Random errors are caused by noise in the detected signal. Variability of the photon statistics in the lidar return signal, noise resulting from detector dark current, and noise in the background signal are the main sources of random error. This type of error can be minimized by maximizing the signal to noise ratio. The increase in the signal to noise ratio can be achieved by several ways. One way is to increase the laser pulse energy, by increasing its amplitude or the pulse repetition rate. Another way, is to use a detector system with higher quantum efficiency and lower noise, on the other hand, the selection of a narrow band optical filter that rejects most of the day background light and retains high optical efficiency is an important issue. Following acquisition of the lidar data, we minimize random errors in the DIAL measurement by averaging the data, but this will result in the reduction of the vertical and horizontal resolutions. Thus, a trade off is necessary to achieve a balance between the spatial resolution and the measurement precision. Therefore, the main goal of this research effort is to increase the signal to noise ratio by a factor of 10 over the current system, using a newly evaluated, very low noise avalanche photo diode detector and constructing a 10 MHz waveform digitizer which will replace the current CAMAC system.

Elsayed-Ali, Hani↗

Comparison of Two Methods for Noninvasive Determination of Stroke Volume During Orthostatic Challenge

Background: The real time, beat-by-beat, non-invasive determination of stroke volume (SV) is an important parameter in many aerospace related physiologic protocols. In this study, we compared simultaneous estimates of SV calculated from peripheral pulse waveforms with a more conventional non-invasive technique. Methods: Using a prospective, randomized blinded protocol, ten males and nine females completed 12-mm tilt table protocols. The relative change (%(Delta)) in beat-to-beat SV was estimated non-invasively from changes in pulse waveforms measured by application of infrared finger photoplethysmography (IFP) with a Portapres(Registered TradeMark) blood pressure monitoring device and by thoracic impedance cardiography (TIC). The %(Delta) SV values were calculated from continuous SV measurements in the supine posture and over the first 10 s (T1), second 10 s (T2), and 3.5 minutes (T3) of 80deg head-up tilt (HUT). Results: The average %(Delta) SV measured by IFP at T1 (-11.7 +/- 3.7 %) was statistically less (P <0.02) than the average %(Delta) SV measured by TIC at T1 (-21.7 +/- 3.1 %), while the average %(Delta) SV measured by 1FF at T2 (-16.2 +/- 3.9 %) and T3 (-19.1 +/- 3.8 %) were not statistically distinguishable (P > or = 0.322) than the average %(Delta) SV measured by TIC at T2 (-21.8 +/- 2.5 %), and T3 (-22.6 +/- 2.9 %). Correlation coefficients (r(sup 2)) between IFP and TIC were 0.117 (T1), 0.387 (T2), and 0.7 18 (T3). Conclusion: IFP provides beat-to-beat (real time) assessment of %(Delta) SV after 20 sec of transition to an orthostatic challenge that is comparable to the commonly accepted TIC. Our data support the notion that IFP technology which has flown during space missions can be used to accurately assess physiological status and countermeasure effectiveness for orth static problems that may arise in astronauts after space flight. While the peripherally measured IFP response is slightly delayed, the ease of implementing this monitor in the field is advantageous.

Doerr, Donald F.↗

ARTEMIS Observations of Plasma Waves in Laminar and Perturbed Interplanetary Shocks

The ‘Acceleration, Reconnection, Turbulence and Electrodynamics of the Moon's Interaction with the Sun’ (ARTEMIS) mission provides a unique opportunity to study the structure of interplanetary shocks and the associated generation of plasma waves with frequencies between ~50-8000 Hz due to its long duration electric and magnetic field burst waveform captures. We compare wave properties and occurrence rates at 11 quasi-perpendicular interplanetary shocks with burst data within 10 minutes (~3200 proton gyroradii upstream, ~1900 downstream) of the shock ramp. A perturbed shock is defined as possessing a large amplitude whistler precursor in the quasi-static magnetic field with an amplitude greater than ⅓ the difference between the upstream and downstream average magnetic field magnitudes; laminar shocks lack these large precursors and have a smooth, step function-like transition. In addition to wave modes previously observed, including ion acoustic, whistler, and electrostatic solitary waves, waves in the ion acoustic frequency range that show rapid temporal frequency change are common. Three shocks had burst captures in the ramp; of these, the two laminar shocks with burst data in the ramp contained a wide range of large amplitude wave modes in the ramp whereas the one perturbed shock contained no such waves. Thus, energy dissipation through wave-particle interactions is more prominent in these two laminar shocks than in the perturbed shock. Based on observations from all 11 shocks, the The wave occurrence rates for laminar shocks are higher in the transition region, especially the ramp, than downstream. In contrast, perturbed shocks have approximately 2-3 times the wave occurrence rate downstream than laminar shocks.

L. A. Davis↗

The influence of higher harmonics on vortex pairing in an axisymmetric mixing layer

Strong forcing was used to produce vortex pairing in a submerged axisymmetric water jet. Phase-averaged hot-wire measurements were combined with phase-averaged flow visualization to identify the relevant nonlinear interactions. The leading resonant interaction was not a subharmonic resonance. Instead, it was a triad resonance involving the subharmonic, the fundamental and the 3/2 harmonic. The profound influence of higher harmonics on the amplification of the fundamental and subharmonic was demonstrated in a systematic way by successive truncation of the Fourier series representation of the excitation waveform.

Petersen, R. A.↗

Control Electronics For Reaction Wheel

Bidirectional operation achieved with single-polarity main power supply. Control circuitry generates pulse-width-modulated 800-Hz waveforms to drive two-phase ac motor and reaction wheel. Operates partly in response to digital magnitude-and-direction torque command generated by external control subsystem and partly in response to tachometric feedback in form of two once-per-revolution sinusoids with amplitudes proportional to speed. Operation in either of two modes called "normal" and "safehold." In normal mode, drive pulses timed so that, on average over one or few cycles, motor applies commanded torque. In safehold mode, pulses timed to keep motor running at set speed in one direction.

Chamberlin, Keith↗

Characteristics and Preliminary Observations of the Influence of Electromyostimulation on the Size and Function of Human Skeletal Muscle During 30 Days of Simulated Microgravity

During 30 days (d) of bedrest, the practicality of using Elec- troMyoStimulation (EMS) as a deterrent to atrophy and strength loss of lower limb musculature was examined. An EMS system was developed that provided variable but quantifiable levels of EMS, and measured torque. The dominant log of three male subjects was stimulated twice daily in a 3-d on/1-d off cycle during bedrest. The non-dominant leg of each subject acted as a control. A stimulator, using a 0.3 ms monophasic 60 Hz pulse waveform, activated muscle tissue for 4 s. The output waveform from the stimulator was sequenced to the Knee Extensors (KE), Knee Flex- ors (KF), Ankle Extensors (AE), and Ankle Flexors (AF), and caused three isometric contractions of each muscle group per minute. Subject tolerance determined EMS Intensity. Each muscle group received four 5-min bouts of EMS each session with a 10 -min rest between bouts. EMS and torque levels for each muscle action were recorded directly an a computer. Overall average EMS Intensity was 197, 197, 195, and 188 mA for the KE, KF, AF, and AE, respectively. Overall average torque development for these muscle groups was 70, 16, 12, and 27 Nm, respectively. EMS intensity doubled during the study, and average torque increased 2.5 times. Average maximum torque throughout a session reached 54% of maximal voluntary for the KE and 29% for the KF. Reductions in leg volume, muscle compartment size, cross-sectional area of slow and fast-twitch fibers, strength, and aerobic enzyme activities, and increased log compliance were attenuated in the legs which received EMS during bedrest. These results indicate that similar EMS levels induce different torques among different muscle groups and that repeated exposure to EMS increases tolerance and torque development. Longer orien- tation periods, therefore, may enhance its effectiveness. Our preliminary data suggest that the efficacy of EMS as an effective countermeasure for muscle atrophy and strength loss during long duration space travel warrants further investigation.

Duvoisin, Marc R.↗

Pulsed multiwavelength laser ranging system

A pulsed multiwavelength laser ranging system for measuring atmospheric delay was built and tested, and its theoretical performance limits were calculated. The system uses a dye modelocked ND:YAG laser, which transmits 70 psec wide pulses simultaneously at 1064, 532, and 355 nm. The differential delay of the 1064 and 355 nm pulses is measured by a specially calibrated waveform digitizer to estimate the dry atmospheric delay. The delay time of the 532 nm pulse is used to measure the target distance. Static crossed field photomultipliers are used as detectors for all wavelengths. Theoretical analysis shows that path curvature and atmospheric turbulence are fundamental limits to the ranging accuracy of both single and multicolor systems operating over horizontal paths. For two color systems, an additional error is caused by the uncertainty in the path averaged water vapor. The standard deviation of the multicolor instrument's timing measurements is directly proportional to the laser pulse width plus photomultiplier jitter divided by the square root of the received photoelectron number. The prototype system's maximum range is km, which is limited by atmospheric and system transmission losses at 355 nm. System signal detection and false alarm calculations are also presented.

Abshire, J. B.↗

Acoustic Optimization for Anti-Phase Asymmetric Rotor

This investigation seeks to optimize the implementation of anti-phase alternating trailing edge (TE) patterns for rotor noise suppression. The design objective is to maximize reduction of noise perceived by the community while maintaining the aerodynamic thrust. Computations using a three-dimensional Unsteady-Reynolds-Averaged-Navier-Stokes (URANS) with k-w Shear Stress Transport (SST) turbulence model and Ffowcs-Williams and Hawkings (FW-H) formula are used to obtain aerodynamic thrust and far-field noise level. A parametric acoustic study of 13 configurations of KDE rotor with variable alternating trailing edge period, alternating trailing edge length, and trailing edge deflection angle is conducted. The best design candidate for the KDE rotor has a four-period TE waveform which results in a reduction in far-field noise level of 2.1 dB in the hover condition and a reduction of 1.1 dB in the forward flight condition at 9.7 m/s. A further parametric acoustic study is conducted for a different rotor manufactured by APC. Six APC rotor design candidates are simulated. The best design candidate 4H for the APC rotor results in a reduction in far-field noise level of 4.0 dB in the hover condition and a reduction of 1.3 dB in the forward flight condition at 9.7 m/s. A series of acoustic experiments in the Penn State University (PSU) anechoic chamber have been conducted. In the forward flight condition at 9.7 m/s, the APC anti-phase 4H rotor offers clear evidence of noise suppression capability across a wide range of the azimuthal angle. In the broadband frequency range of 2000-4000 Hz, the APC anti-phase 4H rotor produces as much as 6 dB noise reduction. The experimental results appear to confirm the noise suppression capability of the proposed anti-phase rotor design concepts.

Xiong, Juntao↗

Features of Point Clouds Synthesized from Multi-View ALOS/PRISM Data and Comparisons with LiDAR Data in Forested Areas

LiDAR waveform data from airborne LiDAR scanners (ALS) e.g. the Land Vegetation and Ice Sensor (LVIS) havebeen successfully used for estimation of forest height and biomass at local scales and have become the preferredremote sensing dataset. However, regional and global applications are limited by the cost of the airborne LiDARdata acquisition and there are no available spaceborne LiDAR systems. Some researchers have demonstrated thepotential for mapping forest height using aerial or spaceborne stereo imagery with very high spatial resolutions.For stereo imageswith global coverage but coarse resolution newanalysis methods need to be used. Unlike mostresearch based on digital surface models, this study concentrated on analyzing the features of point cloud datagenerated from stereo imagery. The synthesizing of point cloud data from multi-view stereo imagery increasedthe point density of the data. The point cloud data over forested areas were analyzed and compared to small footprintLiDAR data and large-footprint LiDAR waveform data. The results showed that the synthesized point clouddata from ALOSPRISM triplets produce vertical distributions similar to LiDAR data and detected the verticalstructure of sparse and non-closed forests at 30mresolution. For dense forest canopies, the canopy could be capturedbut the ground surface could not be seen, so surface elevations from other sourceswould be needed to calculatethe height of the canopy. A canopy height map with 30 m pixels was produced by subtracting nationalelevation dataset (NED) fromthe averaged elevation of synthesized point clouds,which exhibited spatial featuresof roads, forest edges and patches. The linear regression showed that the canopy height map had a good correlationwith RH50 of LVIS data with a slope of 1.04 and R2 of 0.74 indicating that the canopy height derived fromPRISM triplets can be used to estimate forest biomass at 30 m resolution.

LiDARD↗

Coping with Trial-to-Trial Variability of Event Related Signals: A Bayesian Inference Approach

In electro-neurophysiology, single-trial brain responses to a sensory stimulus or a motor act are commonly assumed to result from the linear superposition of a stereotypic event-related signal (e.g. the event-related potential or ERP) that is invariant across trials and some ongoing brain activity often referred to as noise. To extract the signal, one performs an ensemble average of the brain responses over many identical trials to attenuate the noise. To date, h s simple signal-plus-noise (SPN) model has been the dominant approach in cognitive neuroscience. Mounting empirical evidence has shown that the assumptions underlying this model may be overly simplistic. More realistic models have been proposed that account for the trial-to-trial variability of the event-related signal as well as the possibility of multiple differentially varying components within a given ERP waveform. The variable-signal-plus-noise (VSPN) model, which has been demonstrated to provide the foundation for separation and characterization of multiple differentially varying components, has the potential to provide a rich source of information for questions related to neural functions that complement the SPN model. Thus, being able to estimate the amplitude and latency of each ERP component on a trial-by-trial basis provides a critical link between the perceived benefits of the VSPN model and its many concrete applications. In this paper we describe a Bayesian approach to deal with this issue and the resulting strategy is referred to as the differentially Variable Component Analysis (dVCA). We compare the performance of dVCA on simulated data with Independent Component Analysis (ICA) and analyze neurobiological recordings from monkeys performing cognitive tasks.

Ding, Mingzhou↗