Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SU-F-T-676: Measurement of Hydroxyl Radicals in Radiolized Water Systems

Purpose: Hydroxyl radicals can be produced within tissue by radiation therapy, and they are largely responsible for DNA damage and cell killing. Coumarin-3-carboxylic acid (3-CCA) and crystal violet are reported to react with hydroxyl radicals and can be used for fluorescence and absorbance measurements, respectively. This study assesses the ability of hydroxyl measurement for both 3-CCA and crystal violet in radiolized water systems in order to provide dosimetric information in radiation chemistry and radiation biology experiments. Methods: 3-CCA and crystal violet were both dissolved in phosphate buffered saline (PBS, pH 7.4) with final concentrations 0.5 mg/mL and 0.05 mg/mL. 3-CCA and control solutions (PBS only) were loaded in black bottom 96-well plates. Crystal violet and control solutions were loaded in clear bottom 96-well plates. The prepared solutions were irradiated at 2 Gy using a small animal radiation research platform. Fluorescence reading with 360 nm excitation wavelength and 485 nm emission wavelength was done for 3-CCA, and absorbance reading at wavelength 580 nm was done for crystal violet before and after radiation. Results: 3-CCA showed clear difference in fluorescence before and after radiation, which suggested hydroxyl production during radiation. However, crystal violet absorbance at 580 nm was not changed significantly by radiation. Conclusion: The overall conclusion is that 3-CCA can be used for hydroxyl measurement in radiolized water systems, while crystal violet cannot, although crystal violet is reported widely to react with hydroxyl radicals produced in Fenton reactions. Possible reasons could relate to reaction pH.

60 APPLIED LIFE SCIENCES↗

Initial Trade Study for In-line Silver Sensor for Spacecraft Potable Water Systems

Ionic silver is currently baselined as the biocide for microbial control in potable water systems for future space exploration missions. In-line monitoring of silver ion concentration is desired for system feedback control to introduce and maintain sufficient and safe levels of biocide in the water. To date, NASA testing of silver biocide system prototypes has made use of an Ion-Selective Electrode (ISE) for in-line silver concentration measurements. However, known issues with ISE technology have continued to motivate a search for alternate sensor systems. Although devices capable of detecting silver are available for terrestrial applications, these systems are generally not well-suited for the unique demands of spaceflight. Desired attributes include: low weight, volume, and power consumption; stable, autonomous, and in-line measurement capability; long calibration lifetime; and limited maintenance requirements. This paper provides the results from a preliminary trade study conducted on three candidate silver sensor technologies: ISEs, Anodic Stripping Voltammetry (ASV), and Fiber Optic Chemical Sensors (FOCS). The review of these technologies includes the rationale for their selection, an overview of the principles of their operation, and a detailed assessment of their strengths and weaknesses relative to the anticipated requirements of future spacecraft applications. The study concluded that none of the currently-available versions of these technologies is suitable for immediate application to spacecraft systems; further technology development should be considered. To that end, recommendations for forward development work have been proposed and provided herein.

Potable Water↗

Effects of Residual Water System Silver on Space Crop Microbiome and Nutrient Content

Ionic silver (Ag+) is being investigated as a residual biocide for use in spacecraft potable water systems on future crewed missions. In addition to providing clean water to the crew and other life support system functions, the potable water is used to irrigate space crop production units such as the Vegetable Production System (Veggie) and the Advanced Plant Habitat (APH). We have evaluated the impact of different concentrations of Ag+ biocide solutions in comparison to a control in both substrate (arcillite-based) and substrate-less (hydroponics-based) growth set ups. Here, we provide evidence that increasing the concentration of silver in the irrigation water impacts the root zone microbiome in both setups, with plant growth and elemental nutrient content also affected in the hydroponic set up. This suggests a need for a silver removal step to achieve acceptable silver levels in irrigation water before application to space crops in a substrate-less hydroponics system. This removal step is also recommended for a substrate-based system, although it is not as critical as in a hydroponics system.

Aubrie O’Rourke↗

Using a Large Language Model for Accurate Technical Language Generation in the Predictive Maintenance of Circulating Water Systems in Nuclear Power Plants

Machine learning (ML) methods for predictive maintenance (PdM) are emerging as effective proactive strategies for diagnosing equipment degradation and enabling effective decision-making. However, explainability and trustworthiness of artificial intelligence are two salient challenges that need to be addressed for wider deployment of these technologies in nuclear power plants (NPPs). Large language models (LLMs) offer a unique approach to tackle these challenges by explaining PdM, work orders, diagnosis results, and ML algorithms to users, who may not be familiar with ML and PdM in general. Moreover, by dynamically retrieving relevant information from technical documents and evaluating factuality of LLM generation, the accuracy and relevance of LLM generations can be improved. This work demonstrates using LLMs to explain the causes and consequences of circulating water system failures based on multiyear NPP work orders. This work tests the capability of multimodal LLM approaches in explaining the differences in the circulating water system from both the Salem and Hope Creek NPPs using both text and image resources. This work also demonstrates the use of multimodal LLMs in describing the diagnosis tab of a predictive maintenance software named VIsualization for PrEdictive maintenance Recommendation (VIPER) to users.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS) baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selctive field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, we are developing a double chemically-sensitive field effect transistor (dChemFET). The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. We report our work in developing the dChemFET, starting with the development of the Ag+ and NO3- ion selective memberanes (ISMs) to be used in the ChemFETs. The Ag+ ISM has a detection range of 50-105 ppb . The counter ion ISM, NO3- ISM, has shown a detection range of 400-105 ppb. NO3- ISMs are limited in detecting at lower ppb levels required for the dChemFET application on the potable water system. In response to this issue, we also report our studies in using the Ag+ ISM to measure deionized (DI) water as a reference measurement to be implemented in-line before the Ag+ is dosed.

Lance Dean Delzeit↗

Condition-Based Maintenance of a Circulating Water System of a Canadian Nuclear Power Plant using Machine Learning and Statistical Tools

Canada Deuterium Uranium pressurized-heavy-water reactors (PHWR) are a type of nuclear power plant that generate clean and reliable energy. The scope of this work is to automate data analysis methodologies to inform a condition-based maintenance strategy of a circulating water system (CWS) of a PHWR. The multiunit CWS provides a continuous supply of water to cool steam condensers, even during transient scenarios, thereby improving the thermal efficiency. This work aims to develop a machine learning (ML) based approach to detect anomalies in heterogeneous data of a CWS in a PHWR to help inform a predictive maintenance strategy. The heterogeneous data include textual and numeric time series data for a PHWR. Natural-language-processing (NLP)-based models are used to analyze textual data contained in work orders and operator logs and an event-timeseries correlation detection method is applied to assist anomalies diagnoses for CWS. An ML model Robust Linear Model (RLM) is also used to remove the seasonal variations in the system variable distributions based on distributions of environmental variables. A machine learning model, Density-Based Spatial Clustering of Applications with Noise (DBSCAN), trained on both original data and data without any seasonal variations will then be used to detect if an anomaly exists. Thus, by moving to an automated methodology to detect, classify, and forecast anomalies, the maintenance strategy would be based on component condition instead of a time-based schedule.

97 - MATHEMATICS AND COMPUTING↗

Water system virus detection

The performance of a waste water reclamation system is monitored by introducing a non-pathogenic marker virus, bacteriophage F2, into the waste-water prior to treatment and, thereafter, testing the reclaimed water for the presence of the marker virus. A test sample is first concentrated by absorbing any marker virus onto a cellulose acetate filter in the presence of a trivalent cation at low pH and then flushing the filter with a limited quantity of a glycine buffer solution to desorb any marker virus present on the filter. Photo-optical detection of indirect passive immune agglutination by polystyrene beads indicates the performance of the water reclamation system in removing the marker virus. A closed system provides for concentrating any marker virus, initiating and monitoring the passive immune agglutination reaction, and then flushing the system to prepare for another sample.

Fraser, A. S.↗

Solar hot water system installed at Anderson, South Carolina

A description is given of the solar energy hot water system installed in the Days Inns of America, Inc., at Anderson, South Carolina. The building is a low-rise, two-story 114-room motel. The solar system was designed to provide 40 percent of the total hot water demand. The collector is a flat plate, liquid with an area of 750 square feet. Operation of this system was begun in November 1977, and has performed flawlessly for one year.

Source record↗

Genome Sequences of Bacteria Isolated from the International Space Station Water Systems

We report draft genomes of five bacteria recovered from the United States and Russian water systems onboard the International Space Station: bacteria of the genera Ralstonia, Burkholderia, Cupriavidus, Methylobacterium, and Pseudomonas. These sequences will help further the understanding of water reclamation and environmental control and life support systems in space.

Christian L. Castro↗

IMEX HDG-DG: A coupled implicit hybridized discontinuous Galerkin and explicit discontinuous Galerkin approach for shallow water systems

We propose IMEX HDG-DG schemes for planar and spherical shallow water systems. Of interest is subcritical flow, where the speed of the gravity wave is faster than that of nonlinear advection. In order to simulate these flows efficiently, we split the governing system into a stiff part describing the gravity wave and a non-stiff part associated with nonlinear advection. The former is discretized implicitly with the HDG method while an explicit Runge-Kutta DG discretization is employed for the latter. The proposed IMEX HDG-DG framework: 1) facilitates high-order solutions both in time and space; 2) avoids overly small time-step sizes; 3) requires only one linear system solve per time stage; 4) relative to DG generates smaller and sparser linear systems while promoting further parallelism; and 5) suppresses the fast modes in the system with a large time-step size. Numerical results for various test cases demonstrate that our methods are beneficial for applications where non-stiff terms are accurately treated while stiff terms are less accurately handled.

42 ENGINEERING↗

G189A analytical simulation of the RITE Integrated Waste Management-Water System

This paper discusses the computer simulation of the Integrated Waste Management-Water System Using Radioisotopes for Thermal Energy (RITE) and applications of the simulation. Variations in the system temperature and flows due to particular operating conditions and variations in equipment heating loads imposed on the system were investigated with the computer program. The results were assessed from the standpoint of the computed dynamic characteristics of the system and the potential applications of the simulation to system development and vehicle integration.

Coggi, J. V.↗

Prototype solar heating and hot water system

Progress is reported in the development of a solar heating and hot water system which uses a pyramidal optics solar concentrator for heating, and consists of the following subsystems: collector, control, transport, and site data acquisition. Improvements made in the components and subsystems are discussed.

Source record↗

A software framework for assessing the resilience of drinking water systems to disasters with an example earthquake case study

Water utilities are vulnerable to a wide variety of human-caused and natural disasters. The Water Network Tool for Resilience (WNTR) is a new open source PythonTM package designed to help water utilities investigate resilience of water distribution systems to hazards and evaluate resilience-enhancing actions. In this paper, the WNTR modeling framework is presented and a case study is described that uses WNTR to simulate the effects of an earthquake on a water distribution system. The case study illustrates that the severity of damage is not only a function of system integrity and earthquake magnitude, but also of the available resources and repair strategies used to return the system to normal operating conditions. While earthquakes are particularly concerning since buried water distribution pipelines are highly susceptible to damage, the software framework can be applied to other types of hazards, including power outages and contamination incidents.

97 MATHEMATICS AND COMPUTING↗

BioMoSS: ROS-generating Photocatalysts for the Disinfection of Potable Water Systems

With NASA’s desire to replace iodine as the biocide within the potable water system of future missions, we continue our development of the biocidal MoS2 (BioMoSS) system. BioMoSS is a visible-light activated photocatalyst based upon few-layered vertically aligned molybdenum disulfide (FLV-MoS2) for the production of reactive oxygen species (ROS) as a biocide. FLV-MoS2 has been reported to have a high bacterial kill rate. We report significant improvements in the vertical-alignment and biocidal efficacy of the FLV-MoS2 compared to our initial results reported last year. Furthermore, we report the results of peroxide formation with and without surface deposition using gold. Finally, we investigate the delamination of the FLV-MoS2 films under immersion in water.

Antiseptics↗

The potable water system in Skylab

Description of the medical requirements, development, system operation, and in-flight performance of the Skylab potable water system. Emphasized is the description of the unique features involving new space-flight concepts, procedures, and design incorporated in Skylab. The water supplied to the three Skylab missions was preloaded in stainless-steel tanks. These tanks were fitted with positive expulsion stainless-steel bellows. In-flight iodination of the water, for bacterial control, was accomplished as required. An in-flight bactericide monitor was used periodically to determine the level of bactericide in the water. Prior to the delivery of the water to the crewmen for consumption, the water was passed through a cation exchange resin for metallic ion removal and then heated for food reconstitution or chilled for drinking.

R. L. Sauer↗

Preliminary design package for solar hot water system

This package includes technical information, schematics, drawings and brochures of the solar hot water system. This system consists of the following subsystems: collector, storage, transport, control, auxiliary energy, and Government-furnished site data acquisition. The two units being manufactured will be installed at Loxahatchee, Florida, and Macon, Georgia.

Source record↗