Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water Management Strategies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Nonstationarity in the global terrestrial water cycle and its interlinkages in the Anthropocene

Climate change and human activities alter the global freshwater cycle, causing nonstationary processes as its distribution shifting over time, yet a comprehensive understanding of these changes remains elusive. Here, we develop a remote sensing–informed terrestrial reanalysis and assess the nonstationarity of and interconnections among global water cycle components from 2003 to 2020. We highlight 20 hotspot regions where terrestrial water storage exhibits strong nonstationarity, impacting 35% of the global population and 45% of the area covered by irrigated agriculture. Emerging long-term trends dominate the most often (48.2%), followed by seasonal shifts (32.8%) and changes in extremes (19%). Notably, in mid-latitudes, this encompasses 34% of Asia and 27% of North America. The patterns of nonstationarity and their dominant types differ across other water cycle components, including precipitation, evapotranspiration, runoff, and gross primary production. These differences also manifest uniquely across hotspot regions, illustrating the intricate ways in which each component responds to climate change and human water management. Our findings emphasize the importance of considering nonstationarity when assessing water cycle information toward the development of strategies for sustainable water resource usage, enhancing resilience to extreme events, and effectively addressing other challenges associated with climate change.

Science & Technology - Other Topics↗

Data Repository for Multi-Objective Urban Observational Strategies: A risk-based framework for expanding flood sensor networks.

These data support the manuscript "Multi-Objective Urban Observational Strategies: A risk-based framework for expanding flood sensor networks." These data are generated to allow water managers to reason about optimal locations to expand a flood observation system from multiple perspectives, specifically focusing on flood hazards, and population exposure to flooding. The data included are a) a shapefile of individual sensor locations b) a shapefile of river reach catchments, c) raster of FEMA flood likelihood layers d) shapefile of population locations and population socioeconomic characteristics. The code is written in R and includes all files necessary to generate the figures for the associated manuscript. Interactive maps of the final calculated maps of hazard, vulnerability, exposure, and risk are also included as html files.

54 ENVIRONMENTAL SCIENCES↗

PFAS Waste Management for Industrial, Water, and Wastewater Treatment Facilities

Per- and polyfluoroalkyl substances (PFAS), including perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), are widely used in industrial and consumer products due to their unique water and oil repelling properties. These slow-degrading and bio-accumulating compounds, often called "forever chemicals," are not typically removed by conventional industrial and municipal water/wastewater (W/WW) treatment. This tip of the month provides comprehensive strategies for managing PFAS-contaminated waste streams. Understanding the various types of PFAS waste streams is the first step in managing them. Primary PFAS waste includes contaminated process W/WW and solid materials directly from the production and processing of PFAS-containing materials. These might come from manufacturing facilities, firefighting training areas, or other industrial operations where PFAS compounds are used or were historically present. Secondary PFAS waste results from treatment and disposal mechanisms of primary PFAS waste streams, including spent activated carbon, used ion exchange resins, membrane reject streams, PFAS-laden backwash water, landfill leachate, incineration residuals, etc. TABLE 1 lists examples of the most common PFAS waste streams in different industrial facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

42 ENGINEERING↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Kennedy Space Center Five Year Sustainability Plan

The Federal Government is committed to following sustainable principles. At its heart, sustainability integrates environmental, societal and economic solutions for present needs without compromising the ability of future generations to meet their needs. Building upon its pledge towards environmental stewardship, the Administration generated a vision of sustainability spanning ten goals mandated within Executive Order (EO) 13693, Planning for Federal Sustainability in the Next Decade. In November 2015, the National Aeronautics and Space Administration (NASA) responded to this EO by incorporating it into a new release of the NASA Strategic Sustainability Performance Plan (SSPP). The SSPP recognizes the importance of aligning environmental practices in a manner that preserves, enhances and strengthens NASA's ability to perform its mission indefinitely. The Kennedy Space Center (KSC) is following suit with KSC's Sustainability Plan (SP) by promoting, maintaining and pioneering green practices in all aspects of our mission. KSC's SP recognizes that the best sustainable solutions use an interdisciplinary, collaborative approach spanning civil servant and contractor personnel from across the Center. This approach relies on the participation of all employees to develop and implement sustainability endeavors connected with the following ten goals: Reduce greenhouse gas (GHG) emissions. Design, build and maintain sustainable buildings, facilities and infrastructure. Leverage clean and renewable energy. Increase water conservation. Improve fleet and vehicle efficiency and management. Purchase sustainable products and services. Minimize waste and prevent pollution. Implement performance contracts for Federal buildings. Manage electronic equipment and data centers responsibly. Pursue climate change resilience. The KSC SP details the strategies and actions that address the following objectives: Reduce Center costs. center dot Increase energy and water efficiencies. Promote smart buying practices. Increase reuse and recycling while decreasing waste. Benefit the community. Meet or exceed the EO and NASA SSPP sustainability goals.

Sustainability↗

Soil management legacy interacts with wheat genotype to determine access to organic N in a dryland system

Organic nutrient management through the application of compost and/or cover crops provides mineralizable sources of nutrients for plants while often building soil organic matter (SOM) and various aspects of soil health. Variability in nutrient acquisition strategies between crop genotypes may confer advantages under different soil health contexts and could be important for crop selection and breeding, but crop response under field conditions remains unexplored. We investigated the ability of different genotypes of winter wheat (Triticum aestivum L.) to access nitrogen (N) from newly added cover crop residues in two soils with contrasting levels of SOM and biological activity. We planted three previously characterized wheat genotypes in a long-term dryland compost amendment field trial: 1) Byrd (modern, deep roots, low exudation), 2) Cheyenne (historic, drought susceptible, intermediate exudation), and 3) Snowmass (modern, drought-susceptible, high exudation). 15 N-labelled cover crop residue was added to each plot and traced into wheat tissue. In the low SOM soil, the high exudate genotype Snowmass and historic genotype Cheyenne took up the most residue-derived N (6.4–8.1 kg N ha −1 ) compared to the low-exudate genotype Byrd (4.4 kg N ha −1 ), suggesting a strong exudate effect in the more carbon-limited soil. However, in the high SOM soil, the low-exudate, deep rooted genotype, Byrd, took up the most residue N (4.6 kg N ha −1 vs. 2.8 and 3.3 hg N ha −1 for Cheyenne and Snowmass, respectively), which indicated higher native N cycling activities and greater importance of drought resistance. Enzyme activity, inorganic N, and microbial communities were not influenced by genotype, though did show strong effects of compost application legacy. Furthermore, our results show that belowground allocation strategies that favor microbial stimulation may be less successful under water limitation, especially when high native SOM and biological activity can support mineralization of residue N without added investment in root inputs. Increased soil health through SOM-building management likely enhances nutrient cycling, and may better support root strategies that invest less in microbial stimulation in favor of other limiting resources.

Compost↗

Space Station environmental control and life support system distribution and loop closure studies

The NASA Space Station's environmental control and life support system (ECLSS) encompasses functional elements concerned with temperature and humidity control, atmosphere control and supply, atmosphere revitalization, fire detection and suppression, water recovery and management, waste management, and EVA support. Attention is presently given to functional and physical module distributions of the ECLSS among these elements, with a view to resource requirements and safety implications. A strategy of physical distribution coupled with functional centralization is for the air revitalization and water reclamation systems. Also discussed is the degree of loop closure desirable in the initial operational capability status Space Station's oxygen and water reclamation loops.

Humphries, William R.↗

National Energy Water Treatment & Speciation (NEWTS): A Water & Critical Mineral Database and Dashboard

The scarcity of water resources, the need for beneficial water reuse, and the challenges of wastewater treatment are becoming increasingly pressing in economic, social, and environmental domains. Addressing these concerns requires effective treatment strategies to manage wastewater streams and tackle environmental and economic issues. Furthermore, the recovery of critical minerals from the waste streams associated with energy production holds the promise of offsetting treatment costs and securing local sources of valuable minerals. However, relevant data on these waste streams are dispersed and challenging to locate. The process of ingesting such data into modeling software often involves multiple steps, requiring data restructuring to meet software-input requirements. The non-standardized reporting of water data makes data aggregation and reformatting a time-consuming process. Additionally, essential attributes necessary for modeling water treatment and mineral scale formation are frequently missing. Moreover, data gaps vary depending on the region of interest. Consequently, there is a pressing need for high-quality energy-water composition data that can be easily imported into water chemistry modeling software. To address this need, the National Energy Technology Laboratory has created the National Energy Water Treatment and Speciation (NEWTS) Database and Dashboard—a free online tool catering to community leaders and water researchers. NEWTS facilitates a comprehensive understanding of the composition of energy-related wastewater streams in the United States. The datasets provide detailed concentrations and speciation of major and minor aqueous compounds in energy-related wastewater streams, including power plant leachate, acid mine drainage, brackish water, and oil and gas produced water across the United States. Many of the aqueous species are critical minerals (Li, REEs) in high demand to modernize the world’s energy infrastructure. Many of the datasets also contain volumetric flow-rates needed to model the treatment and reuse scenarios in advanced aqueous chemistry software programs. The NEWTS Database and Dashboard offer public access to hitherto challenging-to-access datasets, presented in a standardized format that is tailored for easy input into aqueous chemistry modeling software. By performing the work needed to transform dispersed, disparate data sources into unified, model-ready datasets, NEWTS serves as an essential resource in advancing water treatment research and sustainable water resource management.

produced water management↗

W.A.T.E.R. Water Assessment & Technical Efficiency Report

Water use at Los Alamos National Laboratory (LANL) has become a top priority due to New Mexico’s arid climate. LANL is taking steps to reduce its current water footprint and become a national leader in water efficiency. LANL used approximately 271 million gallons of water in FY 2021. Despite the large water footprint, the Lab has reduced its water use by 2% each year since a 2007 baseline. To continue this positive trend of water conservation, the water management team at Utilities & Infrastructure – Operations Support & Improvement (UI-OSI) studied water usage across campus and developed several water reduction strategies.

54 ENVIRONMENTAL SCIENCES↗

Global Precipitation Measurement (GPM) Mission: Overview and Status

The Global Precipitation Measurement (GPM) Mission is an international satellite mission specifically designed to unify and advance precipitation measurements from a constellation of research and operational microwave sensors. NASA and JAXA will deploy a Core Observatory in 2014 to serve as a reference satellite to unify precipitation measurements from the constellation of sensors. The GPM Core Observatory will carry a Ku/Ka-band Dual-frequency Precipitation Radar (DPR) and a conical-scanning multi-channel (10-183 GHz) GPM Microwave Radiometer (GMI). The DPR will be the first dual-frequency radar in space to provide not only measurements of 3-D precipitation structures but also quantitative information on microphysical properties of precipitating particles. The DPR and GMI measurements will together provide a database that relates vertical hydrometeor profiles to multi-frequency microwave radiances over a variety of environmental conditions across the globe. This combined database will be used as a common transfer standard for improving the accuracy and consistency of precipitation retrievals from all constellation radiometers. For global coverage, GPM relies on existing satellite programs and new mission opportunities from a consortium of partners through bilateral agreements with either NASA or JAXA. Each constellation member may have its unique scientific or operational objectives but contributes microwave observations to GPM for the generation and dissemination of unified global precipitation data products. In addition to the DPR and GMI on the Core Observatory, the baseline GPM constellation consists of the following sensors: (1) Special Sensor Microwave Imager/Sounder (SSMIS) instruments on the U.S. Defense Meteorological Satellite Program (DMSP) satellites, (2) the Advanced Microwave Scanning Radiometer-2 (AMSR-2) on the GCOM-W1 satellite of JAXA, (3) the Multi-Frequency Microwave Scanning Radiometer (MADRAS) and the multi-channel microwave humidity sounder (SAPHIR) on the French-Indian MeghaTropiques satellite, (4) the Microwave Humidity Sounder (MHS) on the National Oceanic and Atmospheric Administration (NOAA)-19, (5) MHS instruments on MetOp satellites launched by the European Organization for the Exploitation of Meteorological Satellites (EUMETSAT), (6) the Advanced Technology Microwave Sounder (ATMS) on the National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP), and (7) ATMS instruments on the NOAA-NASA Joint Polar Satellite System (JPSS) satellites. Data from Chinese and Russian microwave radiometers may also become available through international collaboration under the auspices of the Committee on Earth Observation Satellites (CEOS) and Group on Earth Observations (GEO). The current generation of global rainfall products combines observations from a network of uncoordinated satellite missions using a variety of merging techniques. GPM will provide "next-generation" precipitation products characterized by: (1) more accurate instantaneous precipitation estimate (especially for light rain and cold-season solid precipitation), (2) intercalibrated microwave brightness temperatures from constellation radiometers within a consistent framework, and (3) unified precipitation retrievals from constellation radiometers using a common a priori hydrometeor database constrained by combined radar/radiometer measurements provided by the GPM Core Observatory. GPM is a science mission with integrated applications goals. GPM will provide a key measurement to improve understanding of global water cycle variability and freshwater availability in a changing climate. The DPR and GMI measurements will offer insights into 3-dimensional structures of hurricanes and midlatitude storms, microphysical properties of precipitating particles, and latent heat associated with precipitation processes. The GPM mission will also make data available in near realtime (within 3 hours of observations) forocietal applications ranging from position fixes of storm centers, numerical weather prediction, flood forecasting, freshwater management, landslide warning, crop prediction, to tracking of water-borne diseases. An overview of the GPM mission design, retrieval strategy, ground validation activities, and international science collaboration will be presented.

Hou, Arthur Y.↗

Biocrust Mosses and Cyanobacteria Exhibit Distinct Carbon Uptake Responses to Variations in Precipitation Amount and Frequency

ABSTRACT Dryland organisms exhibit varied responses to changes in precipitation, including event size, frequency, and soil moisture duration, influencing carbon uptake and reserve management strategies. This principle, central to the pulse‐reserve paradigm, has not been thoroughly evaluated in biological soil crusts (biocrusts), essential primary producers on dryland surfaces. We conducted two experiments to investigate carbon uptake in biocrusts under different precipitation regimes. In the first, we applied a gradient of watering amounts to biocrusts dominated by moss or cyanobacteria, hypothesising distinct pulse‐response strategies. The second experiment extended watering treatments over three months, varying pulse size and frequency. Our results revealed distinct carbon uptake patterns: moss crusts exhibited increased CO 2 uptake with larger, less frequent watering events, whereas cyanobacteria crusts maintained similar carbon uptake across all event sizes. These findings suggest divergent pulse‐response strategies across biocrust types, with implications for modelling dryland carbon dynamics and informing land management under changing precipitation regimes.

Young, Kristina E. [USDA‐ARS Jornada Experimental ↗

Strong Correspondence in Evapotranspiration and Carbon Dioxide Fluxes Between Different Eddy Covariance Systems Enables Quantification of Landscape Heterogeneity in Dryland Fluxes

Abstract The eddy covariance method is widely used to investigate fluxes of energy, water, and carbon dioxide at landscape scales, providing important information on how ecological systems function. Flux measurements quantify ecosystem responses to environmental perturbations and management strategies, including nature‐based climate‐change mitigation measures. However, due to the high cost of conventional instrumentation, most eddy covariance studies employ a single system, limiting spatial representation to the flux footprint. Insufficient replication may be limiting our understanding of ecosystem behavior. To address this limitation, we deployed eight lower‐cost eddy covariance systems in two clusters around two conventional eddy covariance systems in the Chihuahuan Desert of North America for a period of 2 years. These dryland settings characterized by large temperature variations and relatively low carbon dioxide fluxes represented a challenging setting for eddy covariance. We found very good closure of energy and water balance across all systems (within ±9% of unity). We found very good correspondence between the lower‐cost and conventional systems' fluxes of sensible heat (with concordance correlation coefficient (CCC) of ≥0.87), latent energy (evapotranspiration; CCC ≥ 0.89), and useful correspondence in the net ecosystem exchange ((NEE); with CCC ≥ 0.4) at the daily temporal resolution. Relative to the conventional systems, the low‐frequency systems were characterized by a higher level of random error, particularly in the NEE fluxes. Lower‐cost systems can enable wider deployment affording better replication and sampling of spatiotemporal variability at the expense of greater measurement noise that might be limiting for certain applications. Replicated eddy covariance observations may be useful when addressing gaps in the existing monitoring of critical and underrepresented ecosystems and for measuring areas larger than a single flux footprint.

54 ENVIRONMENTAL SCIENCES↗

Developing Coastal Adaptation to Climate Change in the New York City Infrastructure-Shed: Process, Approach, Tools, and Strategies

While current rates of sea level rise and associated coastal flooding in the New York City region appear to be manageable by stakeholders responsible for communications, energy, transportation, and water infrastructure, projections for sea level rise and associated flooding in the future, especially those associated with rapid icemelt of the Greenland and West Antarctic Icesheets, may be beyond the range of current capacity because an extreme event might cause flooding and inundation beyond the planning and preparedness regimes. This paper describes the comprehensive process, approach, and tools developed by the New York City Panel on Climate Change (NPCC) in conjunction with the region s stakeholders who manage its critical infrastructure, much of which lies near the coast. It presents the adaptation approach and the sea-level rise and storm projections related to coastal risks developed through the stakeholder process. Climate change adaptation planning in New York City is characterized by a multi-jurisdictional stakeholder-scientist process, state-of-the-art scientific projections and mapping, and development of adaptation strategies based on a risk-management approach.

Rosenzweig, Cynthia↗

How Rains and Floods Become Groundwater: Understanding Recharge Pathways With Stable and Cosmogenic Isotopes

Anthropogenic climate change leads to increased precipitation intensity and exacerbated droughts in California, challenging the reliability and drought resiliency of water supply. Storing floodwater underground via managed aquifer recharge can mitigate these effects through direct infiltration or streambed infiltration. Seasonally dry streams (arroyos) already play an important part in managing groundwater recharge to the Livermore basin (CA). Understanding how, when and where stormwater and arroyo water infiltrate is critical to effectively utilise this strategy. To track water from recent storms (water year 2022–2023, WY23) into the Livermore Valley Groundwater Basin, we analysed stable water isotopes (δ 18 O and δ 2 H) in combination with naturally occurring radioactive isotopic tracers, sulphur-35 ( 35 S, t ½ = 87 days) and tritium ( 3 H, t ½ = 12.3 years). By comparing measurements of δ 18 O, 35 S and 3 H in arroyos to precipitation and groundwater, we classified the relative age and identified source of recharge to 16 wells near two arroyos. Two wells contained water with recent recharge (from WY23) from local precipitation. One well had recent recharge from variable (precipitation and imported water) sources. One well contained imported water recharge. Three wells contained water from mixed recent and older (pre-WY23) waters, from local precipitation sources. Two wells contained recent recharge from local mine settling ponds. Seven wells had older recharge from local precipitation sources. This combination of isotopes allows us to delineate where local and imported water recharges in this highly managed basin and identify locations where managed aquifer recharge is contributing to rapid groundwater infiltration. Our combined interpretation of isotopic water ages and sources in the context of land use shows that local infiltration of precipitation in open spaces is an important recharge mechanism, in addition to the managed arroyo recharge. Finally, a broader familiarity with 35 S will enable more extensive research on the infiltration of urban floodwaters.

58 GEOSCIENCES↗