Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WOUNDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Impact behavior of filament wound graphite/epoxy fan blades

The fabrication and impact tests of graphite/epoxy filament wound fan blades are discussed. Blades which were spin tested at tip speeds up to 305 meters per second retained their structural integrity. Two blades were each impacted with a 454 gram slice of a 908 gram simulated bird at a tip speed of 263 meters per second and impact angles of 22 and 32 deg. The impact tests were recorded with high-speed movie film. The blade which was impacted at 22 deg sustained some root delamination but remained intact. The 32 deg impact separated the blade from the root. No local damage other than leading edge debonding was observed for either blade. Results of a failure mode analysis are also discussed.

Bowles, K. J.↗

Recent advances in lightweight, filament-wound composite pressure vessel technology

A review of recent advances is presented for lightweight, high-performance composite pressure vessel technology that covers the areas of design concepts, fabrication procedures, applications, and performance of vessels subjected to single-cycle burst and cyclic fatigue loading. Filament-wound fiber/epoxy composite vessels were made from S-glass, graphite, and Kevlar 49 fibers and were equipped with both structural and nonstructural liners. Pressure vessel structural efficiencies were attained which represented weight savings, using different liners, of 40 to 60 percent over all-titanium pressure vessels. Significant findings in each area are summarized including data from current NASA-Lewis Research Center contractual and in-house programs.

Lark, R. F.↗

Variabilities detected by acoustic emission from filament-wound Aramid fiber/epoxy composite pressure vessels

Two hundred and fifty Aramid fiber/epoxy pressure vessels were filament-wound over spherical aluminum mandrels under controlled conditions typical for advanced filament-winding. A random set of 30 vessels was proof-tested to 74% of the expected burst pressure; acoustic emission data were obtained during the proof test. A specially designed fixture was used to permit in situ calibration of the acoustic emission system for each vessel by the fracture of a 4-mm length of pencil lead (0.3 mm in diameter) which was in contact with the vessel. Acoustic emission signatures obtained during testing showed larger than expected variabilities in the mechanical damage done during the proof tests. To date, identification of the cause of these variabilities has not been determined.

Hamstad, M. A.↗

Impact behavior of filament-wound graphite/epoxy fan blades

The fabrication and impact tests of graphite/epoxy filament wound fan blades are discussed. Blades which were spin tested at tip speeds up to 305 m/sec retained their structural integrity. Two blades were each impacted with a 454-g slice of a 908-g simulated bird at a tip speed of 263 deg and impact angles of 22 deg and 32 deg. The impact tests were recorded with high-speed movie film. The blade which was impacted at 22 deg sustained some root delamination but remained intact. The 32 deg impact separated the blade from the root. No local damage other than leading-edge debonding was observed for either blade. The results of a failure mode analysis are also discussed.

Bowles, K. J.↗

Spiral-wound gasket forms low-temperature seal

Spiral-wound cryogenic gasket with one component requires no encapsulant and is easily produced with self-locking features. Seal either opens and closes or is fixed. It is made by skiving strip from circumference of disk of glass-filled material. Successive turns of strip are spirally wrapped in groove machined into one flange surface. Closing joint compresses gasket.

Irick, S. C.↗

Modified spiral wound retaining ring

A spiral wound retaining ring with angled ends is described. The ring is crimped at the same angle as the ring ends to maintain a constant thickness dimension. The angling of the ends of the ring and crimp allow the ends to be positioned closer together while maintaining enough clearance to enable insertion and removal of the ring. By reducing the separation distance between the ends a stronger ring results since the double layer area of the ring is maximized.

Lawson, A. G.↗

A mathematical model for the doubly fed wound rotor generator

A mathematical analysis of a doubly-fed wound rotor machine used as a constant frequency generator is presented. The purpose of this analysis is to derive a consistent set of circuit equations which produce constant stator frequency and constant stator voltage. Starting with instantaneous circuit equations, the necessary rotor voltages and currents are derived. The model, thus obtained, is assumed to be valid, since the resulting relationships between mechanical power and active volt-amperes agrees with the results of others. In addition, the model allows for a new interpretation of the power flow in the doubly-fed generator.

Brady, F. J.↗

A mathematical model for the doubly-fed wound rotor generator, part 2

A mathematical analysis of a doubly-fed wound rotor generator is presented. The constraints of constant stator voltage and frequency to the circuit equations were applied and expressions for the currents and voltages in the machine obtained. The derived variables are redefined as direct and quadrature components. In addition, the apparent (complex) power for both the rotor and the stator are derived in terms of these redefined components.

Brady, F. J.↗

Preliminary report on tests of tensile specimens with a part-through surface notch for a filament wound graphite/epoxy material

The behavior of tensile coupons with surface notches of various semi-elliptical shapes were evaluated for specimens obtained from a filament wound graphite/epoxy cylinder. The quasi-static test results, in some instances, are inadequate for defining complete trend curves and the interpretive analysis is considered to be preliminary. Specimens with very shallow notches were observed to be notch insensitive and the unnotched strength from these specimens was determined to be 54.97 Ksi. The failure strain of the laminate was found to be 1.328%. Specimens with deeper notches were sensitive to notch depth, notch aspect ratio, and specimen width. Using the unnotched strength of 54.97 Ksi and Poe's general toughness parameter, the fracture toughness was estimated to be 27.2 Ksi square root of In. Isotropic linear elastic fracture mechanics together with the estimated fracture toughness correctly predicted the influence of notch depth, aspect ratio, and specimen finitewidth.

Harris, C. E.↗

SRM filament wound case resin characterization studies

The amine cured epoxy wet winding resin used in fabrication of the SRM filament wound case is analyzed. High pressure liquid chromatography (HPSC) is utilized extensively to study lot-to-lot variation in both resin and curing agent. The validity of quantitative hplc methodology currently under development in-process resin/catalyst assay is assessed.

Chou, L. W.↗

The fracture behavior of filament wound cylinders with surface flaws

The behavior of tensile coupons with surface notches of various semielliptical shapes has been evaluated for specimens obtained from a thick filament wound graphite/epoxy cylinder. Specimens with very shallow notches were observed to be notch insensitive and the unnotched strength from these specimens was determined to be 54.97 Ksi with an associated failure strain of 1.328 percent. Specimens with deeper notches were sensitive to notch depth and notch aspect ratio. Isotropic linear elastic fracture mechanics with an estimated fracture toughness of 27.2 Ksi-in.-to the 1/2 correctly predicted the influence of notch depth, aspect ratio and specimen finite width.

Harris, C. E.↗

Optimization of pin bearing joint strength for segmented graphite/epoxy filament wound case in Space Shuttle

An attempt is made to demonstrate the feasibility of a composite joint in a segmented, graphite/epoxy filament-wound composite case for the Space Shuttle's Solid Rocket Motors. The joint's required ultimate line load is of the of 82,000 lb/in. By optimizing composite layup, and the ratios of pin diameter/specimen thickness, edge distance/pin diameter, and specimen width/pin diameter, a pin bearing joint strength of 85 ksi was obtained. Double pin testing disclosed that the pin close to the composite joint carries a higher load than the outboard pin. Pin bearing strength is noted to vary with matrix resin system.

Munjal, A. K.↗

Water impact testing of a filament wound case

A lightweight Filament Wound Case (FWC) Solid Rocket Booster (SRB) is being developed by NASA to increase the payload capability of the space shuttle. As with the steel boosters, the current plan is to recover the FWC SRB's after they impact the ocean at 65 to 85 ft/sec. As the boosters enter the ocean (nozzle first) the water moves away from the vehicle creating a cavity, which then collapses on the vehicle, and results in a significant loading event. To understand this loading event, tests were conducted on a quarter scale FWC model to measure cavity collapse pressure distributions, deflected shape and the effects of end conditions and pressure scaling.

Schmidt, A. A.↗

Dielectric cure monitoring of the 55A filament wound case resin

Studies were conducted to correlate data from dielectric cure monitoring of 55A filament would case resins using the Micromet System II with differential scanning calorimetry and resin strength tests. Strength tests for resin bonding at various time intervals and DSC are standard accepted techniques for monitoriong resin cure cycles. They are time consuming, destructive, and non-continuous. The Micromet System II will yield reliable information on degree of cure and other parameters, which should allow better quality control on filament wound case resin cure.

Mcnutt, R. C.↗

Effects of external environments on the short beam shear strength of filament wound graphite/epoxy

Filament wound graphite/epoxy samples were immersed in seawater, deionized water, and toluene at room temperature and 80 deg C for 5, 15, and 43 days, and in methanol at room temperature for 15 and 43 days. The percent weight gains and short beam shear strengths were determined after environmental exposure. Samples immersed in deionized water and seawater had higher percent weight gains than those immersed in toluene at room temperature and 80 deg C. The percent weight gains for samples immersed in methanol at room temperature were comparable to those of deionized water and seawater immersed samples. A comparison of percent decreases in short beam shear strengths could not be made due to a large scatter in data. This may indicate defects in samples due to machining or variations in material properties due to processing.

Penn, B. G.↗

Acousto-ultrasonic verification of the strength of filament wound composite material

The concept of acousto-ultrasonic (AU) waveform partitioning was applied to nondestructive evaluation of mechanical properties in filament wound composites (FWC). A series of FWC test specimens were subjected to AU analysis and the results were compared with destructively measured interlaminar shear strengths (ISS). AU stress-wave factor (SWF) measurements gave greater than 90 percent correlation coefficient upon regression against the ISS. This high correlation was achieved by employing the appropriate time and frequency domain partitioning as dictated by wave propagation path analysis. There is indication that different SWF frequency partitions are sensitive to ISS at different depths below the surface.

Kautz, H. E.↗

A mathematical model for the doubly-fed wound rotor generator. II

A mathematical analysis of a doubly-fed wound rotor generator is presented. The constraints of constant stator voltage and frequency to the circuit equations were applied and expressions for the currents and voltages in the machine obtained. The derived variables are redefined as direct and quadrature components. In addition, the apparent (complex) power for both the rotor and the stator are derived in terms of these redefined components.

Brady, F. J.↗