Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WIRING SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Three-Dimensional Vibration Isolator for Suppressing High-Frequency Responses for Sage III Contamination Monitoring Package (CMP)

The Stratospheric Aerosol and Gas Experiment (SAGE) III - International Space Station (ISS) instrument will be used to study ozone, providing global, long-term measurements of key components of the Earth's atmosphere for the continued health of Earth and its inhabitants. SAGE III is launched into orbit in an inverted configuration on SpaceX;s Falcon 9 launch vehicle. As one of its four supporting elements, a Contamination Monitoring Package (CMP) mounted to the top panel of the Interface Adapter Module (IAM) box experiences high-frequency response due to structural coupling between the two structures during the SpaceX launch. These vibrations, which were initially observed in the IAM Engineering Development Unit (EDU) test and later verified through finite element analysis (FEA) for the SpaceX launch loads, may damage the internal electronic cards and the Thermoelectric Quartz Crystal Microbalance (TQCM) sensors mounted on the CMP. Three-dimensional (3D) vibration isolators were required to be inserted between the CMP and IAM interface in order to attenuate the high frequency vibrations without resulting in any major changes to the existing system. Wire rope isolators were proposed as the isolation system between the CMP and IAM due to the low impact to design. Most 3D isolation systems are designed for compression and roll, therefore little dynamic data was available for using wire rope isolators in an inverted or tension configuration. From the isolator FEA and test results, it is shown that by using the 3D wire rope isolators, the CMP high-frequency responses have been suppressed by several orders of magnitude over a wide excitation frequency range. Consequently, the TQCM sensor responses are well below their qualification environments. It is indicated that these high-frequency responses due to the typical instrument structural coupling can be significantly suppressed by a vibration passive control using the 3D vibration isolator. Thermal and contamination issues were also examined during the isolator selection period for meeting the SAGE III-ISS instrument requirements.

Li, Y.↗

Emergency escape system uses self-braking mechanism on fixed cable

Slide-wire system with a twist level slide device incorporates automatic descent and braking for the safe and rapid evacuation of personnel from tall structures. This device is used on any tall structure that might require emergency evacuation. It is also used to transfer materials and equipment.

Billings, C. R.↗

Polymer Chemistry

This viewgraph presentation describes new technologies in polymer and material chemistry that benefits NASA programs and missions. The topics include: 1) What are Polymers?; 2) History of Polymer Chemistry; 3) Composites/Materials Development at KSC; 4) Why Wiring; 5) Next Generation Wiring Materials; 6) Wire System Materials and Integration; 7) Self-Healing Wire Repair; 8) Smart Wiring Summary; 9) Fire and Polymers; 10) Aerogel Technology; 11) Aerogel Composites; 12) Aerogels for Oil Remediation; 13) KSC's Solution; 14) Chemochromic Hydrogen Sensors; 15) STS-130 and 131 Operations; 16) HyperPigment; 17) Antimicrobial Materials; 18) Conductive Inks Formulations for Multiple Applications; and 19) Testing and Processing Equipment.

Williams, Martha↗

Nonlinear dynamical system approaches towards neural prosthesis

An asynchronous discrete-state spiking neurons is a wired system of shift registers that can mimic nonlinear dynamics of an ODE-based neuron model. The control parameter of the neuron is the wiring pattern among the registers and thus they are suitable for on-chip learning. In this paper an asynchronous discrete-state spiking neuron is introduced and its typical nonlinear phenomena are demonstrated. Also, a learning algorithm for a set of neurons is presented and it is demonstrated that the algorithm enables the set of neurons to reconstruct nonlinear dynamics of another set of neurons with unknown parameter values. The learning function is validated by FPGA experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanization of and experience with a triplex fly-by-wire backup control system

A redundant three axis analog control system was designed and developed to back up a digital fly by wire control system for an F-8C airplane. The mechanization and operational experience with the backup control system, the problems involved in synchronizing it with the primary system, and the reliability of the system are discussed. The backup control system was dissimilar to the primary system, and it provided satisfactory handling through the flight envelope evaluated. Limited flight tests of a variety of control tasks showed that control was also satisfactory when the backup control system was controlled by a minimum displacement (force) side stick. The operational reliability of the F-8 digital fly by wire control system was satisfactory, with no unintentional downmodes to the backup control system in flight. The ground and flight reliability of the system's components is discussed.

Lock, W. P.↗

Mechanization of and experience with a triplex fly-by-wire backup control system

A redundant three-axis analog control system was designed and developed to back up a digital fly-by-wire control system for an F-8C airplane. Forty-two flights, involving 58 hours of flight time, were flown by six pilots. The mechanization and operational experience with the backup control system, the problems involved in synchronizing it with the primary system, and the reliability of the system are discussed. The backup control system was dissimilar to the primary system, and it provided satisfactory handling through the flight envelope evaluated. Limited flight tests of a variety of control tasks showed that control was also satisfactory when the backup control system was controlled by a minimum-displacement (force) side stick. The operational reliability of the F-8 digital fly-by-wire control system was satisfactory, with no unintentional downmodes to the backup control system in flight. The ground and flight reliability of the system's components is discussed.

Lock, W. P.↗

Digital flight control actuation system study

Flight control actuators and feedback sensors suitable for use in a redundant digital flight control system were examined. The most appropriate design approach for an advanced digital flight control actuation system for development and use in a fly-by-wire system was selected. The concept which was selected consisted of a PM torque motor direct drive. The selected system is compatible with concurrent and independent development efforts on the computer system and the control law mechanizations.

Rossing, R.↗

Orbiter CCTV video signal noise analysis

The amount of steady state and transient noise which will couple to orbiter CCTV video signal wiring is predicted. The primary emphasis is on the interim system, however, some predictions are made concerning the operational system wiring in the cabin area. Noise sources considered are RF fields from on board transmitters, precipitation static, induced lightning currents, and induced noise from adjacent wiring. The most significant source is noise coupled to video circuits from associated circuits in common connectors. Video signal crosstalk is the primary cause of steady state interference, and mechanically switched control functions cause the largest induced transients.

Lawton, R. M.↗

Phase-shift array, arbitrary and continuous through 360 deg

Langley Research Center's Phase-shift array satisfies requirement to phase shift common source signal into array of branch circuits thus simplifying multiple phase control. With system, wiring and assembly are uncomplicated, requiring no switching networks and system can be operated at any desired frequency. Design provides effective solution to problem of multiple shift control.

Dibble, A. C., Jr.↗

Laser measuring system for wire-wrapped frame assemblies

The laser measuring system is designed to automatically measure and record the distances between small diameter wires on a wire wrapped grid frame assembly to an accuracy of 0.00635 mm (0.00025 in.). The system utilizes a helium-neon gas laser beam as the measuring instrument with a remote interferometer and retroreflector, a light source and photodetector to detect the wire positions, in conjunction with recording, display and printout units. The laser measuring system is utilized to perform precise automatic measurements for wire application machines or as an automatic feedback device for positioning wires and/or to adjust them for out of tolerance conditions.

Etzel, J. G.↗

Hy-wire measurements of atmospheric potential

A method for directly measuring the electric potential drop across the lowest portion of the atmosphere by using an apparatus called Hy-wire is described. The Hy-wire system consists of a long, high-voltage, insulated conductor connected at the top to a wire-mesh braid and terminated at the bottom inside a large-diameter corona ball mounted on 1 m Teflon legs. The system impedance is near 10 billion ohms, while the grounded mode, Hy-wire draws about 10 micro-a at 500 m altitude. Around-the-clock measurements with characteristic peaks near 1530 and 1900 UT of potentials near 125,000 volts are presented, with total daily average potential near 90,000 volts at 507 m altitude. The experimental weather conditions varied from clear to local fog, except that there was only trace precipitation. The data have been interpreted in terms of the possible source of the potential variations; neither a local nor a global source is clearly indicated.

Holzworth, R. H.↗

Rotating-Coil Measurement System for Small-Bore-Diameter Magnet Characterization

Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.

42 ENGINEERING↗

Fault-tolerance techniques for high-speed fiber-optic networks

Four fiber optic network topologies (linear bus, ring, central star, and distributed star) are discussed relative to their application to high data throughput, fault tolerant networks. The topologies are also examined in terms of redundancy and the need to provide for single point, failure free (or better) system operation. Linear bus topology, although traditionally the method of choice for wire systems, presents implementation problems when larger fiber optic systems are considered. Ring topology works well for high speed systems when coupled with a token passing protocol, but it requires a significant increase in protocol complexity to manage system reconfiguration due to ring and node failures. Star topologies offer a natural fault tolerance, without added protocol complexity, while still providing high data throughput capability.

Deruiter, John↗

Multipoint Measurements in an Axisymmetric Sudden Expansion

A flying wire system was utilized in conjunction with a rake of nine cross-wire probes to obtain simultaneous velocity measurements in an axisymmetric sudden expansion at a Reynolds number of 41,000. From these measurements, the correlation tensor could be calculated. Knowledge of the two-point correlation tensor reveals more in-depth information of the physical attributes of this flow. The two point correlation tensor allowed for calculation of the integrated length scales in both the radial and axial directions. This gives insight into the growth of structures with increasing downstream distance and at different radial locations through out the sudden expansion. The length scales were calculated by integrating the two-point correlation tensor in the radial direction from the centerline to the outer pipe wall and by integrating between several step heights for the axial direction. Calculated correlations at z/h = 8 and 9 at r/R = 0.46 showed a correlation length of 1/3 step height for the radial direction. It was found that length scales in the radial direction became larger with increasing radius with peaks at 0.70 e r/R c 0.81 but then decreased slightly towards the wall. Length scales in the axial direction yielded a recirculating bubble on the order of 3 step heights in the recirculating region. After the recirculating region, the length scales decreased to 1/4 of a step height.

Eaton, Erroll L.↗

X-33, X-34, X-37 Press Conference (Tape 2)

Live footage shows Project Managers Susan Turner, MSFC and David Manley, Boeing Co. participating in the X-37 Briefing. NASA's Public Affairs June Malone introduced these panelists who went on to discuss the vehicle and its secondary payload. Manley mentions the X-37 capabilities, main propulsion system, its lithium iron batteries, hot control surfaces, and its fly by wire system. Turner mentions the on-board operations, the deployment of the solar arrays, and the autonomous navigation and landing system. Also included is an animation of the X-37 vehicle during flight and the secondary payload release into orbit.

Source record↗

In-Situ Wire Damage Detection System

An in-situ system for detecting damage in an electrically conductive wire. The system includes a substrate at least partially covered by a layer of electrically conductive material forming a continuous or non-continuous electrically conductive layer connected to an electrical signal generator adapted to delivering electrical signals to the electrically conductive layer. Data is received and processed to identify damage to the substrate or electrically conductive layer. The electrically conductive material may include metalized carbon fibers, a thin metal coating, a conductive polymer, carbon nanotubes, metal nanoparticles or a combination thereof.

Williams, Martha K.↗

Electrical safety requirements: Implications for the module designer

Commercial photovoltaic array installations, which include residential and intermediate applications, are subject to building and electrical codes and to product safety standards. The National Electrical Code (NEC) Article 690, titled Solar Photovoltaic Systems, contains provisions defining acceptable levels of system safety and emphasizes the system design and its installation. The Underwriters Laboratories, Inc. (UL), document titled: Proposed First Edition of the Standard for Flat Plate Photovoltaic Modules and Panels, UL-1703, identifies module and panel construction requirements that ensure product safety. Together these documents describe requirements intended to minimize hazards such as shock and fire. Although initial focus of these requirements is on single crystal silicon modules, they are generic in nature, and are equally applicable to high voltage ( 30 Vdc), multikilowatt, thin film systems. A major safety concern is insulation breakdown within the module or array wiring system, or discontinuities within the electrical conductors. These failures can result in ground faults, in circuit arcs, or exposure to hazardous electrical parts. Safeguards are discussed.

Sugimura, R. S.↗

A Wire Position Monitor System for the 1.3 FHZ Tesla-Style Cryomodule at the Fermilab New-Muon-Lab Accelerator

The first cryomodule for the beam test facility at the Fermilab New-Muon-Lab building is currently under RF commissioning. Among other diagnostics systems, the transverse position of the helium gas return pipe with the connected 1.3 GHz SRF accelerating cavities is measured along the {approx}15 m long module using a stretched-wire position monitoring system. An overview of the wire position monitor system technology is given, along with preliminary results taken at the initial module cooldown, and during further testing. As the measurement system offers a high resolution, we also discuss options for use as a vibration detector. An electron beam test facility, based on superconducting RF (SRF) TESLA-style cryomodules is currently under construction at the Fermilab New-Muon-Lab (NML) building. The first, so-called type III+, cryomodule (CM-1), equipped with eight 1.3 GHz nine-cell accelerating cavities was recently cooled down to 2 K, and is currently under RF conditioning. The transverse alignment of the cavity string within the cryomodule is crucial for minimizing transverse kick and beam break-up effects, generated by the high-order dipole modes of misaligned accelerating structures. An optimum alignment can only be guaranteed during the assembly of the cavity string, i.e. at room temperatures. The final position of the cavities after cooldown is uncontrollable, and therefore unknown. A wire position monitoring system (WPM) can help to understand the transverse motion of the cavities during cooldown, their final location and the long term position stability after cryo-temperatures are settled, as well as the position reproducibility for several cold-warm cycles. It also may serve as vibration sensor, as the wire acts as a high-Q resonant detector for mechanical vibrations in the low-audio frequency range. The WPM system consists out of a stretched-wire position detection system, provided with help of INFN-Milano and DESY Hamburg, and RF generation and read-out electronics, developed at Fermilab.

43 PARTICLE ACCELERATORS↗