Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WASTE PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A comprehensive review on valorization of chestnut processing wastes into bio‐based composites and bioplastics

Abstract This review examines the characterization and utilization of chestnut processing wastes (35%) in the production of bioplastics and biocomposites. In this review, a Web of Science search without any publishing year restriction on the biochemical compositions of all the components of Castanea sativa . The obtaining of bioplastics and biocomposites based on C. sativa was reviewed. First, it highlights the biochemical composition and antioxidant properties of chestnut fruit, shell, burrs, leaves, flowers, and wood focusing on the most important compounds, such as phenolic acids, flavonoids, carbohydrates, Klason lignin, cellulose, and glucan, which can enhance the properties of these materials. Then the review covers using several chestnut extracts and fillers in bioplastics production through solvent casting technique. The mechanical, structural, bioactive properties, and moisture content were optimized through the composition and production. The color, UV absorption, antioxidant, and antimicrobial activity were also discussed. Biocomposites reinforced with chestnut burs, shells, or wood flour increased the intended properties. The enhancements in tensile strength, elastic modulus, and the effects of a pre‐treatment were evaluated. Additionally, it discusses material recovery, recycling, and reuse, particularly how it affects the biodegradability of composites incorporating chestnut waste residues. Highlights Chestnut fruit, shells, and burrs are rich in starch, lignin, and cellulose. The waste of chestnut processing can be used in bioplastics and biocomposites. Chestnut‐based films and biocomposites exhibit promising mechanical properties. The antimicrobial activity, making films, and composites proper for food packaging. New techniques boost performance, offering alternatives to conventional plastics.

Silva, Simão B. [REQUIMTE/LAQV, ISEP, Polytechnic ↗

Reevaluation Of Vitrified High-Level Waste Form Criteria For Potential Cost Savings At The Defense Waste Processing Facility

At the Savannah River Site (SRS) the Defense Waste Processing Facility (DWPF) has been immobilizing SRS's radioactive high level waste (HLW) sludge into a durable borosilicate glass since 1996. Currently the DWPF has poured over 3,500 canisters, all of which are compliant with the U. S. Department of Energy's (DOE) Waste Acceptance Product Specifications for Vitrified High-Level Waste Forms (WAPS) and therefore ready to be shipped to a federal geologic repository for permanent disposal. Due to DOE petitioning to withdraw the Yucca Mountain License Application (LA) from the Nuclear Regulatory Commission (NRC) in 2010 and thus no clear disposal path for SRS canistered waste forms, there are opportunities for cost savings with future canister production at DWPF and other DOE producer sites by reevaluating high-level waste form requirements and compliance strategies and reducing/eliminating those that will not negatively impact the quality of the canistered waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of a Turbidity Meter for Use at the Defense Waste Processing Facility

Savannah River Remediation’s (SRR’s) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a “peanut” vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank. During discussions of the results from this study by WSE, WSL, and Savannah River National Laboratory (SRNL) personnel, an upper limit on the acceptable level of solids in SMECT samples was set at 0.14 weight percent (wt%). A “go/no-go” decision criterion was to be developed for the critical turbidity response, which is expressed in concentration units (CUs), for each Optek unit based upon the 0.14 wt% solids value. An acceptable or a “go” decision for the SMECT should reflect the situation that there is an identified risk (e.g. 5%) for a CU response from the Optek unit to be less than the critical CU value when the solids content of the SMECT is actually 0.14 wt% or greater, while a “no-go” determination (i.e., an Optek CU response above the critical CU value, a conservative decision relative to risk) would lead to additional evaluations of the SMECT to better quantify the possible solids content of the tank. Subsequent to the issuance of the initial version of this report but under the scope of the original request for technical assistance, WSE asked for this report to be revised to include the “go/no-go” CU value corresponding to 0.28 wt% solids. It was this request that led to the preparation of Revision 1 of the report. The results for the 0.28 wt% solids value were developed following the same approach as that utilized for the 0.14 wt% solids value. A sludge simulant was used to develop standards for testing both Optek units and to determine the viability of a “go/no-go” CU response for each of the units. Statistical methods were used by SRNL to develop the critical CU value for the “go/no-go” decision for these standards for each Optek unit. Since only one sludge simulant was available for this testing, the sensitivity of these results to other simulants and to actual sludge material is not known. However, limited testing with samples from the actual DWPF process (both SRAT product samples and SMECT samples) demonstrated that the use of the “go/no-go” criteria developed from the sludge simulant testing was conservative for these samples taken from the sludge batch, Sludge Batch 7b, being processed at the time of this testing. While both of the Optek units performed very reliably during this testing, there were statistically significant differences (although small on a practical scale) between the two units. Thus, testing should be conducted on any new unit of this Optek model to qualify it before it is used to support the DWPF operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility Evaluation and Retrofit Plan for Cold Crucible Induction Melter Deployment in the Defense Waste Processing Facility at Savannah River Site

Cold crucible induction melters (CCIM) have been proposed as an alternative technology for waste glass melting at the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) as well as for other waste vitrification facilities. Proponents of this technology cite high temperature operation, high tolerance for noble metals and aluminum, high waste loading, high throughput capacity, and low equipment cost as the advantages over existing Joule Heated Melter (JHM) technology. The CCIM uses induction heating to maintain molten glass at high temperature. A water-cooled helical induction coil is connected to an AC current supply, typically operating at frequencies from 100 kHz to 5 MHz. The oscillating magnetic field generated by the oscillating current flow through the coil induces eddy currents in conductive materials within the coil. Those oscillating eddy currents, in turn, generate heat in the material. In the CCIM, the induction coil surrounds a 'Cold Crucible' which is formed by metal tubes, typically copper or stainless steel. The tubes are constructed such that the magnetic field does not couple with the crucible. Therefore, the field generated by the induction coil couples primarily with the conductive medium (hot glass) within. The crucible tubes are water cooled to maintain their temperature between 100 deg. C to 200 deg. C so that a protective layer of molten glass and/or batch material, referred to as a 'skull', forms between them and the hot, corrosive melt. Because the protective skull is the only material directly in contact with the molten glass, the CCIM doesn't have the temperature limitations of traditional refractory lined JHM. It can be operated at melt temperatures in excess of 2000 deg. C, allowing processing of high waste loading batches and difficult-to-melt compounds. The CCIM is poured through a bottom drain, typically through a water-cooled slide valve that starts and stops the pour stream. To promote uniform temperature distribution and increase heat transfer to the slurry fed High Level Waste (HLW) sludge, the CCIM may be equipped with bubblers and/or water cooled mechanical agitators. The DWPF could benefit from use of CCIM technology, especially in light of our latest projections of waste volume to be vitrified. Increased waste loading and increased throughput could result in substantial life cycle cost reduction. In order to significantly surpass the waste throughput capability of the currently installed JHM, it may be necessary to install two 950 mm CCIMs in the DWPF Melt Cell. A cursory evaluation of system design requirements and modifications to the facility that may be required to support installation and operation of two 950 mm CCIMs was performed. Based on this evaluation, it appears technically feasible to position two CCIMs in the Melt Cell of the DWPF within the existing footprint of the current melter. Interfaces with support systems and controls including Melter Feed, Power, Melter Cooling Water, Melter Off-gas, and Canister Operations must be designed to support dual CCIM operations. This paper describes the CCIM technology and identifies technical challenges that must be addressed in order to implement CCIMs in the DWPF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation Of A Turbidity Meter For Use At The Defense Waste Processing Facility

Savannah River Remediation’s (SRR’s) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a “peanut” vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impacts of Antifoam Additions and Argon Bubbling on Defense Waste Processing Facility (DWPF) REDuction/OXidation (REDOX)

Control of the REDuction/OXidation (REDOX) state of glass in High Level Waste (HLW) melters, such as the Defense Waste Processing Facility (DWPF), is critical in order to eliminate the formation of metallic species from overly reduced melts while minimizing foaming from overly oxidized melts. The REDOX control is normally a balance of the oxidants and reductants from the feed and from processing additives. However, after reflux in the Sludge Receipt and Adjustment Tank (SRAT) and the Slurry Mix Evaporator (SME), the balance between the oxidizing salts vs. reducing salts can be altered once the mixture is fed to the melter if the melt pool is bubbled with gaseous species that either oxidize or sparge the melt of oxygen. Hence, for a bubbled melt pool, the REDOX of the melt pool must be targeted based on the balance of the oxidizing and reducing salts from the feed and from the processing additives, as well as, accounting for the effects of any gas being bubbled through the melt to improve convection and mixing while also increasing melt rate. For example, one would not set a REDOX target of Fe 2+ /ΣFe of 0.20 based on chemical balancing and then bubble pure air through the melter as pure air would oxidize the melt pool to an Fe 2+ /ΣFe ~0. Some gases, such as argon, are inert but act as chemical sparging agents or “degassing” agents that can sparge out oxygen from the melt and cause the glass to become more reducing. This study examines DWPF flowsheets at various concentrations of antifoam (a reducing processing additive) in the absence of melt pool bubbling (crucible and production data) and in the presence of melt pool bubbling with argon (crucible and production data), a known sparging/degassing agent. In order to de-convolute the impacts of antifoam on the melt pool REDOX from the impacts of melt pool bubbling, crucible studies were performed with (1) varying antifoam concentrations without bubbling, and (2) minimal antifoam with Ar bubbling. This allowed an antifoam term to be added to the REDOX model and suggested that (1) more oxidizing Fe 2+ /ΣFe ratios could be targeted which would create more oxidizing species in the cold cap to offset the effects of Ar-sparging or (2) Ar-air gas mixtures could be blended with a mixing valve to control the melt pool REDOX at the same Fe 2+ /ΣFe ratios (same –log fO 2 ) as chosen for the chemical REDOX balancing. The 2006 EE REDOX model is an electron equivalents (EE) model that balances the electrons lost during oxidation of a reductant against the electrons gained during the reduction of an oxidant. The EE terms for the formates, nitrates, and oxalates in the REDOX model are based on the formatted salts like NaCOOH, the nitrated salts like NaNO 3 , and the oxalated salts like Na 2 C 2 O 4 that have higher decomposition temperatures than their acidic counterparts which flash off. Thus it is the higher decomposition salts that participate in the establishing the melt REDOX during their interactions in the melter cold cap.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

REMOTE IN-CELL SAMPLING IMPROVEMENTS PROGRAM AT THESAVANNAH RIVER SITE (SRS) DEFENSE WASTE PROCESSING FACILITY (DWPF)

Remote Systems Engineering (RSE) of the Savannah River National Lab (SRNL) in combination with the Defense Waste Processing Facility(DWPF) Engineering and Operations has evaluated the existing equipment and processes used in the facility sample cells for 'pulling' samples from the radioactive waste stream and performing equipment in-cell repairs/replacements. RSE has designed and tested equipment for improving remote in-cell sampling evolutions and reducing the time required for in-cell maintenance of existing equipment. The equipment within the present process tank sampling system has been in constant use since the facility start-up over 17 years ago. At present, the method for taking samples within the sample cells produces excessive maintenance and downtime due to frequent failures relative to the sampling station equipment and manipulator. Location and orientation of many sampling stations within the sample cells is not conducive to manipulator operation. The overextension of manipulators required to perform many in-cell operations is a major cause of manipulator failures. To improve sampling operations and reduce downtime due to equipment maintenance, a Portable Sampling Station (PSS), wireless in-cell cameras, and new commercially available sampling technology has been designed, developed and/or adapted and tested. The uniqueness of the design(s), the results of the scoping tests, and the benefits relative to in-cell operation and reduction of waste are presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DEVELOPMENT OF REMOTE HANFORD CONNECTOR GASKET REPLACEMENT TOOLING FOR THE SAVANNAH RIVER SITE'S DEFENSE WASTE PROCESSING FACILITY

The Savannah River Site's (SRS) Defense Waste Processing Facility (DWPF) requested development of tooling for remote replacement of gaskets in mechanical Hanford connectors. The facility has compressed air supply, two master-slave manipulators (MSM's) and a lightweight robotic arm for operation of the remote tools. The Savannah River National Laboratory (SRNL) developed and tested multiple tools to perform the gasket replacement tasks. Separate pneumatic snap-ring removal tools that use the connector skirt as a reaction surface were developed for removal of the snap ring and spent gasket on both vertical and horizontal Hanford connectors. A pneumatic tool that clamps and centers on the jumper pipe ID was developed to simultaneously install the new gasket and snap ring. A pneumatic snap-ring-loading tool was developed that compresses the snap ring and places it in a groove in the installation tool. All of the tools are located on a custom work table with a pneumatic valve station that directs compressed air to the desired tool and vents the tools as needed. The entire system has been successfully tested using MSM's to manipulate the various tools. Deployment of the entire system is expected during FY08. The Hanford connector gasket replacement tooling has been successfully tested using MSM's to manipulate the various tools. Nitric acid is used in many of the decontamination processes performed in the REDC, where the tooling will be deployed. Although most of the tool components were fabricated/purchased with nitric acid and radioactive service in mind, some of the prototype parts must be replaced with parts that are more compatible with nitric acid/radioactive service. Several modifications to the various tools are needed to facilitate maintenance and replacement of failed components. Development of installation tools for replacement of 1-inch, 2-inch and multi-hole gaskets is being considered. Deployment of the existing system in the DWPF REDC is expected during FY08.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Salt Waste Processing Facility August 2022 Tank 201 sample

Two Salt Waste Processing Facility (SWPF) Tank 201 samples were collected from the replacement of the decontaminated salt solution (DSS) coalescer at different times; one in December of 2021 and the other in August 2022. The December 2021 sample was collected after nitric and water flushing of the DSS Coalescer. The Aug 2022 sample was collected after water flushing only. The December 2021 Tank 201 solids were previously characterized and documented. SWPF requested the characterization of the August 2022 Tank 201 sample, and the comparison of the characterization results for these two Tank 201 solids collected at different dates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FEASIBILITY EVALUATION AND RETROFIT PLAN FOR COLD CRUCIBLE INDUCTION MELTER DEPLOYMENT IN THE DEFENSE WASTE PROCESSING FACILITY AT SAVANNAH RIVER SITE 8118

Cold crucible induction melters (CCIM) have been proposed as an alternative technology for waste glass melting at the Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) as well as for other waste vitrification facilities. Proponents of this technology cite high temperature operation, high tolerance for noble metals and aluminum, high waste loading, high throughput capacity, and low equipment cost as the advantages over existing Joule Heated Melter (JHM) technology. The CCIM uses induction heating to maintain molten glass at high temperature. A water-cooled helical induction coil is connected to an AC current supply, typically operating at frequencies from 100 KHz to 5 MHz. The oscillating magnetic field generated by the oscillating current flow through the coil induces eddy currents in conductive materials within the coil. Those oscillating eddy currents, in turn, generate heat in the material. In the CCIM, the induction coil surrounds a 'Cold Crucible' which is formed by metal tubes, typically copper or stainless steel. The tubes are constructed such that the magnetic field does not couple with the crucible. Therefore, the field generated by the induction coil couples primarily with the conductive medium (hot glass) within. The crucible tubes are water cooled to maintain their temperature between 100 C to 200 C so that a protective layer of molten glass and/or batch material, referred to as a 'skull', forms between them and the hot, corrosive melt. Because the protective skull is the only material directly in contact with the molten glass, the CCIM doesn't have the temperature limitations of traditional refractory lined JHM. It can be operated at melt temperatures in excess of 2000 C, allowing processing of high waste loading batches and difficult-to-melt compounds. The CCIM is poured through a bottom drain, typically through a water-cooled slide valve that starts and stops the pour stream. To promote uniform temperature distribution and increase heat transfer to the slurry fed High Level Waste (HLW) sludge, the CCIM may be equipped with bubblers and/or water cooled mechanical agitators. The DWPF could benefit from use of CCIM technology, especially in light of our latest projections of waste volume to be vitrified. Increased waste loading and increased throughput could result in substantial life cycle cost reduction. In order to significantly surpass the waste throughput capability of the currently installed JHM, it may be necessary to install two 950 mm CCIMs in the DWPF Melt Cell. A cursory evaluation of system design requirements and modifications to the facility that may be required to support installation and operation of two 950 mm CCIMs was performed. Based on this evaluation, it appears technically feasible to position two CCIMs in the Melt Cell of the DWPF within the existing footprint of the current melter. Interfaces with support systems and controls including Melter Feed, Power, Melter Cooling Water, Melter Off-gas, and Canister Operations must be designed to support dual CCIM operations. This paper describes the CCIM technology and identifies technical challenges that must be addressed in order to implement CCIMs in the DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BLENDING ANALYSIS FOR RADIOACTIVE SALT WASTE PROCESSING FACILITY

Savannah River National Laboratory (SRNL) evaluated methods to mix and blend the contents of the blend tanks to ensure the contents are properly blended before they are transferred from the blend tank such as Tank 21 and Tank 24 to the Salt Waste Processing Facility (SWPF) feed tank. The tank contents consist of three forms: dissolved salt solution, other waste salt solutions, and sludge containing settled solids. This paper focuses on developing the computational model and estimating the operation time of submersible slurry pump when the tank contents are adequately blended prior to their transfer to the SWPF facility. A three-dimensional computational fluid dynamics approach was taken by using the full scale configuration of SRS Type-IV tank, Tank 21H. Major solid obstructions such as the tank wall boundary, the transfer pump column, and three slurry pump housings including one active and two inactive pumps were included in the mixing performance model. Basic flow pattern results predicted by the computational model were benchmarked against the SRNL test results and literature data. Tank 21 is a waste tank that is used to prepare batches of salt feed for SWPF. The salt feed must be a homogeneous solution satisfying the acceptance criterion of the solids entrainment during transfer operation. The work scope described here consists of two modeling areas. They are the steady state flow pattern calculations before the addition of acid solution for tank blending operation and the transient mixing analysis during miscible liquid blending operation. The transient blending calculations were performed by using the 95% homogeneity criterion for the entire liquid domain of the tank. The initial conditions for the entire modeling domain were based on the steady-state flow pattern results with zero second phase concentration. The performance model was also benchmarked against the SRNL test results and literature data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Defense Waste Processing Facility Canister Closure Weld Current Validation Testing

Two closure welds on filled Defense Waste Processing Facility (DWPF) canisters failed to be within the acceptance criteria in the DWPF operating procedure SW4-15.80-2.3 (1). In one case, the weld heat setting was inadvertently provided to the canister at the value used for test welds (i.e., 72%) and this oversight produced a weld at a current of nominally 210 kA compared to the operating procedure range (i.e., 82%) of 240 kA to 263 kA. The second weld appeared to experience an instrumentation and data acquisition upset. The current for this weld was reported as 191 kA. Review of the data from the Data Acquisition System (DAS) indicated that three of the four current legs were reading the expected values, approximately 62 kA each, and the fourth leg read zero current. Since there is no feasible way by further examination of the process data to ascertain if this weld was actually welded at either the target current or the lower current, a test plan was executed to provide assurance that these Nonconforming Welds (NCWs) meet the requirements for strength and leak tightness. Acceptance of the welds is based on evaluation of Test Nozzle Welds (TNW) made specifically for comparison. The TNW were nondestructively and destructively evaluated for plug height, heat tint, ultrasonic testing (UT) for bond length and ultrasonic volumetric examination for weld defects, burst pressure, fractography, and metallography. The testing was conducted in agreement with a Task Technical and Quality Assurance Plan (TTQAP) (2) and applicable procedures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Savannah River Site Defense Waste Processing Facility Melt Cell Remote Cleanup - 18037

This paper documents experiences at Savannah River Site (SRS) related to both the modification and use of a commercial remote vehicle to remove years of process-related litter (glass and various objects) from a hot cell floor during a production outage. The outage was necessary to replace a Department of Energy Environmental Management (DOE-EM) remotely-operated glass melter that had vitrified waste for 14 years at the Defense Waste Processing Facility. Both chunks of waste glass and numerous items littered the floor of the cell all associated with the long production run. The presence of litter become problematic as it could eventually impede movement or placement of items necessary to continue facility operation. The cleanup also reduces radiation rates within the hot cell which is beneficial. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Antifoam Degradation Products in Off Gas and Condensate of Sludge Batch 9 Simulant Nitric-Formic Flowsheet Testing for the Defense Waste Processing Facility

Ten chemical processing cell (CPC) experiments were performed using simulant to evaluate Sludge Batch 9 for sludge-only and coupled processing using the nitric-formic flowsheet in the Defense Waste Processing Facility (DWPF). Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) cycles were performed on eight of the ten. The other two were SRAT cycles only. Samples of the condensate, sludge, and off gas were taken to monitor the chemistry of the CPC experiments. The Savannah River National Laboratory (SRNL) has previously shown antifoam decomposes to form flammable organic products, (hexamethyldisiloxane (HMDSO), trimethylsilanol (TMS), and propanal), that are present in the vapor phase and condensate of the CPC vessels. To minimize antifoam degradation product formation, a new antifoam addition strategy was implemented at SRNL and DWPF to add antifoam undiluted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvements in design and operation of bubblers in the Savannah river site defense waste processing facility melter - 15163

In order to accelerate the closing of High Level Waste (HLW) tanks at the Savannah River Site (SRS), it was necessary to process more waste throughout the SRS liquid waste facilities. Therefore the Defense Waste Processing Facility (DWPF) needed to increase its production rate of radioactive waste glass filled canisters. To attain the increased production rate, four bubblers were installed in the DWPF Melter in September 2010 to agitate the DWPF Melter glass pool. The four bubblers were designed to be installed in existing nozzles on the top-head of the DWPF Melter. After a few years of successful operation with the original design, several changes have been made to the bubblers. The main change allows for the lower end (inside melter) of the bubbler to be replaced while the top end (outside melter) of the bubbler can be reused. This minimizes cost and waste at the DWPF. Material testing of the Inconel 690 bubbler pipes of used lower bubblers has been performed. Based on the material testing and issue with the integrity of some lower bubbler pipes used in the melter, a protective sleeve at the melt line was also added. Other changes for operational improvement or cost savings have also been made. Overall, performance of the bubblers continues to be excellent as canister production records have been achieved at the DWPF due in large part to the use of bubblers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impacts of Fast Critical Assembly Fuel Discards on Liquid Waste Processes

The Savannah River Nuclear Solutions (SRNS) Fast Critical Assembly (FCA) mission is reestablishing the electrolytic dissolver for processing of Pu and Pu-U materials clad in stainless steel (SS). H-Canyon is planning to dissolve and neutralize FCA fuel without recovering the special nuclear material (i.e., Pu) prior to discarding to the Concentration, Storage, and Transfer Facilities (CSTF) operated by the Savannah River Mission Completion (SRMC) Liquid Waste (LW) Organization. The FCA discards will be combined with sludge in the CSTF after Low Temperature Aluminum Dissolution (LTAD) if needed. The combined waste will be washed, concentrated, and vitrified at the Defense Waste Processing Facility (DWPF). The high level waste canisters produced will be temporarily stored in the Glass Waste Storage Buildings prior to transfer to a future federal repository. Decants from LTAD and sludge washing will be combined with DWPF recycle and dissolved salt cake to prepare salt batches for processing in the Salt Waste Processing Facility. The resulting decontaminated salt solution will be processed in the Saltstone Production Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

QUALIFICATION OF A RADIOACTIVE HIGH ALUMINUM GLASS FOR PROCESSINGIN THE DEFENSE WASTE PROCESSING FACILITY AT THE SAVANNAH RIVER SITE

At the Savannah River Site (SRS) the Defense Waste Processing Facility (DWPF) has been immobilizing SRS's radioactive high level waste (HLW) sludge into a borosilicate glass for approximately eleven years. Currently the DWPF is immobilizing HLW sludge in Sludge Batch 4 (SB4). Each sludge batch is nominally two million liters of HLW and produces nominally five hundred stainless steel canisters 0.6 meters in diameter and 3 meters tall filled with the borosilicate glass. In SB4 and earlier sludge batches, the Al concentration has always been rather low, (less than 9.5 weight percent based on total dried solids). It is expected that in the future the Al concentrations will increase due to the changing composition of the HLW. Higher Al concentrations could introduce problems because of its known effect on the viscosity of glass melts and increase the possibility of the precipitation of nepheline in the final glass and decrease its durability. In 2006 Savannah River National Laboratory (SRNL) used DWPF processes to immobilize a radioactive HLW slurry containing 14 weight percent Al to ensure that this waste is viable for future DWPF processing. This paper presents results of the characterization of the high Al glass prepared in that demonstration. At SRNL, a sample of the processed high Al HLW slurry was mixed with an appropriate glass frit as performed in the DWPF to make a waste glass containing nominally 30% waste oxides. The glass was prepared by melting the frit and waste remotely at 1150 C. The glass was then characterized by: (1) determining the chemical composition of the glass including the concentrations of several actinide and U-235 fission products; (2) calculating the oxide waste loading of the glass based on the chemical composition and comparing it to that of the target; (3) determining if the glass composition met the DWPF processing constraints such as glass melt viscosity and liquidus temperature along with a waste form affecting constraint that prevents the precipitation of nepheline (NaAlSiO{sub 4}) crystals in the glass melt; (4) measuring the durability of the glass using the ASTM Standard Product Consistency Test (PCT) leach test to determine if the durability of the glass based on B, Li, and Na releases met the requirements for acceptance in a US geologic repository; (5) measuring the leachability of several radionuclides using the ASTM Standard PCT leach test and comparing them to the B, Li, and Na releases; and (6) examining the glass by scanning electron microscopy and energy dispersive X-ray spectrometry to determine if any crystals had formed in the glass melt. Results indicate that the high Al glass met all the requirements for processing and product quality in the DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗