Charles Kittel

We discuss solid-state physicist Charles Kittel, a professor emeritus at the University of California, Berkeley, passed away peacefully at his home in Berkeley on 15 May 2019, two months before his 103rd birthday. Born in New York City on 18 July 1916, Charlie entered MIT in 1934. He moved to Cambridge University in 1936 and received his BA there two years later. He earned his PhD degree in 1941 from the University of Wisconsin–Madison, where his adviser was Gregory Breit. From 1940 to 1942, Charlie worked on problems in degaussing and magnetic mine warfare at the Naval Ordnance Laboratory. He served in the US Navy as a research physicist at a British Admiralty research establishment in Scotland and as a naval attaché at the US Embassy in London; he went on to work on antisubmarine warfare and operations research in Washington, DC, and London. In 1945 he returned to MIT, taking a position in the Research Laboratory of Electronics.

99 GENERAL AND MISCELLANEOUS↗

MCNP Simulation of Discrete Gamma-ray Spectra for PGNAA Applications

Prompt Gamma Neutron Activation (PGNAA) systems use the neutron-induced gamma-ray spectra from test objects in order to identify their compositions. The U.S. Army in particular uses these systems to identify the contents of field-recovered munitions in order to determine the presence of chemical warfare materiel (CWM) or explosives. These field-recovered munitions can have a variety of different fills, including experimental fills, have a large range of sizes, and be assessed in different field conditions. All these variations can have a significant effect on the neutron-induced gamma-ray spectrum and therefore a large impact on automatic fill identification algorithms. In order to develop robust identification algorithms, parametric studies of the effects of munition size, fill composition, and assessment conditions are very useful but time-consuming and expensive in the laboratory. Monte Carlo modeling of the system response to these variations is a very attractive alternative, provided the modeling accurately reflects real gamma spectra and can be performed quickly and inexpensively when compared to experiment. At Idaho National Laboratory we have used the Monte Carlo N-Particle (MCNP6) code [2] to calculate the response of the Portable Isotopic Neutron Spectroscopy (PINS) system to a number of simulated chemical warfare munitions as well as performed laboratory measurements with the system. Two versions of PINS system were used; one excited the test object with neutrons from a 252C f source and one with neutrons from a portable deuterium-deuterium (DD) neutron generator. The sets of measurements and simulations with the two different neutron sources provided experimental data for development of automatic fill identification algorithms as well as providing a good test of the agreement between the MCNP calculations and experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Underwater hydrophone location survey

The Atlantic Undersea Test and Evaluation Center (AUTEC) is a U.S. Navy test range located on Andros Island, Bahamas, and a Division of the Naval Undersea Warfare Center (NUWC), Newport, RI. The Headquarters of AUTEC is located at a facility in West Palm Beach, FL. AUTEC's primary mission is to provide the U.S. Navy with a deep-water test and evaluation facility for making underwater acoustic measurements, testing and calibrating sonars, and providing accurate underwater, surface, and in-air tracking data on surface ships, submarines, aircraft, and weapon systems. Many of these programs are in support of Antisubmarine Warfare (ASW), undersea research and development programs, and Fleet assessment and operational readiness trials. Most tests conducted at AUTEC require precise underwater tracking (plus or minus 3 yards) of multiple acoustic signals emitted with the correct waveshape and repetition criteria from either a surface craft or underwater vehicle.

Cecil, Jack B.↗

Molecules for Fluorescence Detection of Specific Chemicals

A family of fluorescent dye molecules has been developed for use in on-off fluorescence detection of specific chemicals. By themselves, these molecules do not fluoresce. However, when exposed to certain chemical analytes in liquid or vapor forms, they do fluoresce (see figure). These compounds are amenable to fixation on or in a variety of substrates for use in fluorescence-based detection devices: they can be chemically modified to anchor them to porous or non-porous solid supports or can be incorporated into polymer films. Potential applications for these compounds include detection of chemical warfare agents, sensing of acidity or alkalinity, and fluorescent tagging of proteins in pharmaceutical research and development. These molecules could also be exploited for use as two-photon materials for photodynamic therapy in the treatment of certain cancers and other diseases. A molecule in this family consists of a fluorescent core (such as an anthracene or pyrene) attached to two end groups that, when the dye is excited by absorption of light, transfer an electron to the core, thereby quenching the fluorescence. The end groups can be engineered so that they react chemically with certain analytes. Upon reaction, electrons on the end groups are no longer available for transfer to the core and, consequently, the fluorescence from the core is no longer quenched. The chemoselectivity of these molecules can be changed by changing the end groups. For example, aniline end groups afford a capability for sensing acids or acid halides (including those contained in chemical warfare agents). Pyridine or bipyridyl end groups would enable sensing of metal ions. Other chemicals that can be selectively detected through suitable choice of end groups include glucose and proteins. Moreover, the fluorescent cores can be changed to alter light-absorption and -emission characteristics: anthracene cores fluoresce at wavelengths around 500 nm, whereas perylene cores absorb and emit at wavelengths of about 600 nm.

Fedor, Steve↗

Kit systems for granulated decontamination formulations

A decontamination formulation and method of making that neutralizes the adverse health effects of both chemical and biological compounds, especially chemical warfare (CW) and biological warfare (BW) agents, and toxic industrial chemicals. The formulation provides solubilizing compounds that serve to effectively render the chemical and biological compounds, particularly CW and BW compounds, susceptible to attack, and at least one reactive compound that serves to attack (and detoxify or kill) the compound. The formulation includes at least one solubilizing agent, a reactive compound, a sorbent additive, and water. A highly adsorbent sorbent additive (e.g., amorphous silica, sorbitol, mannitol, etc.) is used to "dry out" one or more liquid ingredients into a dry, free-flowing powder that has an extended shelf life, and is more convenient to handle and mix in the field. The formulation can be pre-mixed and pre-packaged as a multi-part kit system, where one or more of the parts are packaged in a powdered, granulated form for ease of handling and mixing in the field.

Tucker, Mark D↗

Wargames as experiments: The Project on Nuclear Gaming’s SIGNAL framework

What can we learn from the Peloponnesian War that will help us deal with the intersection of cyber and nuclear conflict? What does World War I teach us about the role of nuclear-capable hypersonic weapons in warfare? Here, the short answer to both questions is—probably not much. While extensive scholarship on nuclear warfare and strategy exists, empirical data on the impact of emerging technologies such as cyber weaponry, advanced intelligence, surveillance, and reconnaissance tools, and precision-guided munitions are lacking. Here, given the importance of policy-relevant research to equip decision-makers with tools to understand nuclear deterrence and reduce the likelihood of nuclear war, the scarcity of data available to analysts remains a critical gap.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Adversarial Artificial Intelligence: State of the Malpractice

Warfare systems are increasingly being supported by artificial intelligence (AI), and its influence is growing. As AI becomes a warfare enabler it has also become a target. For example, AI-enabled machine vision systems can be trivially deceived by specially formulated camouflage. Many approaches to making AI more resilient to protect against specific attacks fail to generalize. However, attacks often do generalize across models trained for the same task, regardless of architecture or training data. This paper will illustrate the state of the practice in offensive and defensive AI and clarify some myths about AI's triumphs and failures in the real world.

Artificial intelligence, AI, cybersecurity, milita↗

Wargames as experiments: The Project on Nuclear Gaming’s SIGNAL framework

What can we learn from the Peloponnesian War that will help us deal with the intersection of cyber and nuclear conflict? What does World War I teach us about the role of nuclear-capable hypersonic weapons in warfare? The short answer to both questions is—probably not much. While extensive scholarship on nuclear warfare and strategy exists, empirical data on the impact of emerging technologies such as cyber weaponry, advanced intelligence, surveillance, and reconnaissance tools, and precision-guided munitions are lacking. Here, given the importance of policy-relevant research to equip decision-makers with tools to understand nuclear deterrence and reduce the likelihood of nuclear war, the scarcity of data available to analysts remains a critical gap.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

On-matrix Derivatization for Dynamic Headspace Sampling of Nonvolatile Surface Residues

The goal of this study is to extend sampling by the field and laboratory emission cell (FLEC) purge-and-trap technique to applications that target nonvolatile residues. On-matrix derivatization of residues to render analytes stable and more volatile is explored to achieve this goal. Results show that on-matrix derivatizations of nerve agent hydrolysis products (monoalkyl methylphosphonic acids and methylphosphonic acid [MPA]) with diazomethane were successful on glass and painted wallboard (at the 10-µg level). It also was successful on the more difficult concrete (at the 500-µg level) and carpet (at the 20-µg level) substrates that cannot be successfully sampled using swipe techniques. Analysis of additional chemical warfare (CW)-associated residues can be approached by on-matrix derivatization with trifluoroacetic anhydride (TFAA). For example, amines (used as stabilizers or present as decomposition products of the nerve agent VX) or thiodiglycol (hydrolysis product of sulfur mustard) could be sampled as their TFAA derivatives from glass, painted wallboard, and concrete (at the 40-µg level), as well as carpet (at the 80-µg level) surfaces. Although the amine and thiodiglycol are semi-volatile and could be sampled directly, derivatization improves the recovery and chromatographic behavior of these analytes.

On-matrix derivatization, in-situ derivatization, ↗

Acute respiratory toxicity following inhalation exposure to soman in guinea pigs

Respiratory toxicity and lung injury following inhalation exposure to chemical warfare nerve agent soman was examined in guinea pigs without therapeutics to improve survival. A microinstillation inhalation exposure technique that aerosolizes the agent in the trachea was used to administer soman to anesthetized age and weight matched male guinea pigs. Animals were exposed to 280, 561, 841, and 1121 mg/m{sup 3} concentrations of soman for 4 min. Survival data showed that all saline controls and animals exposed to 280 and 561 mg/m{sup 3} soman survived, while animals exposed to 841, and 1121 mg/m{sup 3} resulted in 38% and 13% survival, respectively. The microinstillation inhalation exposure LCt{sub 50} for soman determined by probit analysis was 827.2 mg/m{sup 3}. A majority of the animals that died at 1121 mg/m{sup 3} developed seizures and died within 15-30 min post-exposure. There was a dose-dependent decrease in pulse rate and blood oxygen saturation of animals exposed to soman at 5-6.5 min post-exposure. Body weight loss increased with the dose of soman exposure. Bronchoalveolar lavage (BAL) fluid and blood acetylcholinesterase and butyrylcholinesterase activity was inhibited dose-dependently in soman treated groups at 24 h. BAL cells showed a dose-dependent increase in cell death and total cell counts following soman exposure. Edema by wet/dry weight ratio of the accessory lung lobe and trachea was increased slightly in soman exposed animals. An increase in total bronchoalveolar lavage fluid protein was observed in soman exposed animals at all doses. Differential cell counts of BAL and blood showed an increase in total lymphocyte counts and percentage of neutrophils. These results indicate that microinstillation inhalation exposure to soman causes respiratory toxicity and acute lung injury in guinea pigs.

60 APPLIED LIFE SCIENCES↗

Developing health-based pre-planning clearance goals for airport remediation following chemical terrorist attack: Introduction and key assessment considerations

In the event of a chemical terrorist attack on a transportation hub, post-event remediation and restoration activities necessary to attain unrestricted facility re-use and re-entry could require hours to multiple days. While restoration timeframes are dependent on numerous variables, a primary controlling factor is the level of pre-planning and decision-making completed prior to chemical terrorist release. What follows is the first of a two-part analysis identifying key considerations, critical information, and decision criteria to facilitate post-attack and post-decontamination consequence management activities. A conceptual site model and human health-based exposure guidelines are developed and reported as an aid to site-specific pre-planning in the current absence of U.S. state or Federal values designated as compound-specific remediation or re-entry concentrations, and to safely expedite facility recovery to full operational status. Chemicals of concern include chemical warfare nerve and vesicant agents and the toxic industrial compounds phosgene, hydrogen cyanide, and cyanogen chloride. This work has been performed as a national case study conducted in partnership with the Los Angeles International Airport and The Bradley International Terminal. All recommended guidelines have been selected for consistency with airport scenario release parameters of a one-time, short-duration, finite airborne release from a single source followed by compound-specific decontamination.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

PINS Spectrum Identification Guide

The Portable Isotopic Neutron Spectroscopy—PINS, for short—system identifies the chemicals inside munitions and containers without opening them, a decided safety advantage if the fill chemical is a hazardous substance like a chemical warfare agent or an explosive. The PINS Spectrum Identification Guide is intended as a reference for technical professionals responsible for the interpretation of PINS gamma-ray spectra. The guide is divided into two parts. The three chapters that constitute Part I cover the science and technology of PINS. Neutron activation analysis is the focus of Chapter 1. Chapter 2 explores PINS hardware, software, and related operational issues. Gamma-ray spectral analysis basics are introduced in Chapter 3. The six chapters of Part II cover the identification of PINS spectra in detail. Like the PINS decision tree logic, these chapters are organized by chemical element: phosphorus-based chemicals, chlorine-based chemicals, etc. These descriptions of hazardous, toxic, and/or explosive chemicals conclude with a chapter on the identification of the inert chemicals, e.g. sand, used to fill practice munitions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Final report : multicomponent forensic signature development : interactions with common textiles; mustard precursors and simulants.

2-Chloroethyl phenyl sulfide (CEPS), a surrogate compound of the chemical warfare agent sulfur mustard, was examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a novel method of producing multiway data using a stepped thermal desorption. Various multivariate analysis schemes were employed to analyze the data. These methods may be able to discern different sources of CEPS. In addition, CEPS was applied to cotton, nylon, polyester, and silk swatches. These swatches were placed in controlled humidity chambers maintained at 23%, 56%, and 85% relative humidity. At regular intervals, samples were removed from each test swatch, and the samples analyzed using TD/GC-MS. The results were compared across fabric substrate and humidity.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Decontamination and Management of Human Remains Following Incidents of Hazardous Chemical Release

Abstract Objective: To provide specific procedural guidance and resources for identification, assessment, control, and mitigation of compounds that may contaminate human remains resulting from chemical attack or release. Design: A detailed technical, policy, and regulatory review is summarized. Setting: Guidance is suitable for civilian or military settings where human remains potentially contaminated with hazardous chemicals may be present. Settings would include sites of transportation accidents, natural disasters, terrorist or military operations, mortuary affairs or medical examiner processing and decontamination points, and similar. Patients, Participants: While recommended procedures have not been validated with actual human remains, guidance has been developed from data characterizing controlled experiments with fabrics, materiel, and laboratory animals. Main Outcome Measure(s): Presentation of logic and specific procedures for remains management, protection and decontamination of mortuary affairs personnel, as well as decision criteria for determining when remains are sufficiently decontaminated so as to pose no chemical health hazard. Results: Established procedures and existing equipment/materiel available for decontamination and verification provide appropriate and reasonable means to mitigate chemical hazards from remains. Extensive characterization of issues related to remains decontamination indicates that supra-lethal concentrations of liquid chemical warfare agent VX may prove difficult to decontaminate and verify in a timely fashion. Specialized personnel can and should be called upon to assist with monitoring necessary to clear decontaminated remains for transport and processing. Conclusions: Once appropriate decontamination and verification have been accomplished, normal procedures for remains processing and transport to the decedent s family and the continental United States can be followed.

99 GENERAL AND MISCELLANEOUS↗

Degradation Kinetics of VX

O-ethyl S-(2-diisopropylaminoethyl)phosphonothiolate (VX) is the most toxic of the conventional chemical warfare agents. It is a persistent compound, an attribute derived from its relative involatility and slow rates of hydrolysis. These properties suggest that VX can linger in an exposed environment for extended periods of time long after the air has cleared. Concern over prolonged risk from VX exposure is exacerbated by the fact that it poses a dermal contact hazard. Hence a detailed understanding of volatilization rates, and degradation pathways and rates occurring in various environments is needed. Historically, volatilization has not been considered to be an important mechanism for VX depletion, but recent studies have shown that a significant fraction of VX may volatilize, depending on the matrix. A significant body of research has been conducted over the years to unravel VX degradation reaction pathways and to quantify the rates at which they proceed. Rigorous measurement of degradation rates is frequently difficult, and thus in many cases the degradation of VX has been described in terms of half lives, while in fewer instances rate constants have been measured. This variable approach to describing degradation kinetics reflects uncertainty regarding the exact nature of the degradation mechanisms. In this review, rates of VX degradation are compared on the basis of pseudo-first order rate constants, in order to provide a basis for assessing likelihood of VX persistence in a given environment. An issue of specific concern is that one VX degradation pathway produces S-2-(diisopropylaminoethyl) methylphosphonothioic acid (known as EA2192), which is a degradation product that retains much of the original toxicity of VX. Consequently degradation pathways and rates for EA2192 are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mustards and Vesicants

Vesicants (sulfur mustards, lewisite, and nitrogen mustards) are chemicals that cause blistering of the skin. Developed as chemical warfare agents, their biological activity is complex and not fully understood. These vesicants in liquid or vapor form are capable of causing injury to most any tissue. Contact with the skin results in erythema and blistering. Exposure to vapors produces ocular and respiratory effects which occur at exposures below those causing dermal effects. Systemic and long-lasting effects may occur, especially following acute exposures that result in severe injury. Multi-organ involvement and fluid loss shock resulting in death may follow severe exposures. As alkylating agents, all of the mustards are known or potential carcinogens. The carcinogenic potential of lewisite in humans is equivocal. Toxicity data in animals are available for the vesicants although data on sulfur mustard and lewisite are more extensive than for the nitrogen mustards. Data from tests with human volunteers and occupational exposure information are also available. These data collectively have provided a basis for the development of exposure standards, guidelines, and criteria for use in emergency planning and emergency response, and remediation efforts. The mode of action of the vesicants is complex, not fully understood, and represents an ongoing area of investigation especially with respect to treatment of vesicant-induced injury. Prevention of exposure and decontamination are critical initial steps in eliminating or minimizing injury. With the exception of arsenic chelating antidotes (e.g., British anti-lewisite; BAL) for lewisite, no antidotes exist for the vesicant agents. Medical management currently focuses on palliative treatment of signs and symptoms.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Chlorine

Following a brief description of the use of chlorine as a chemical warfare agent in World War I, this chapter summarizes physical and chemical data and recent clinical and controlled laboratory studies on the irritant and lethal effects of chlorine. The mechanism of toxicity for both irritation and lethal effects is described. The mathematical relationship between concentration and exposure duration for a set endpoint is given for both an irritancy response and mortality. This information can be used to assist in time-scaling for the set endpoint to other exposure durations. Risk assessment addresses the potential for greater effects in sensitive populations such as asthmatics. A concentration of 0.5 ppm for up to 8 hours is a no-adverse-effect concentration in most sensitive subjects; whereas, a concentration of 1.0 ppm induces some sensory irritation and transient changes in respiratory tract airflow parameters. Treatment and intervention of exposed individuals is dependent upon symptoms

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Nanoparticle-Based Electrochemical Immunosensor for the Detection of Phosphorylated Acetylcholinesterase: An Exposure Biomarker of Organophosphate Pesticides and Nerve AgentsOrganophosphate Pesticides and Nerve Agents

A nanoparticle-based electrochemical immunosensor has been developed for the detection of phosphorylated acetylcholinesterase (AChE) adducts, which is a potential exposure biomarker for organophosphate pesticides (OP) and chemical warfare nerve agent exposures. Zirconia nanoparticles (ZrO2 NPs) were used as selective sorbents to capture the phosphorylated AChE adduct, and quantum dots (ZnS@CdS, QDs) were used as tags to label monoclonal anti-AChE antibody to track the immunorecognition events. The sandwich-like immunoreactions were performed among the ZrO2 NPs, which were pre-coated on a screen printed electrode (SPE) by electrodeposition, phosphorylated AChE and QD-anti-AChE. The captured QD tags were determined on the SPE by electrochemical stripping analysis of its metallic component (cadmium) after an acid-dissolution step. Paraoxon was used as a model OP insecticide to prepare the phosphorylated AChE adduct to demonstrate the proof of principle for this sensor technology. The paraoxon-AChE adduct was characterized by Fourier Transform Infrared Spectrum, and the binding affinity of anti-AChE to the paraoxon-AChE was validated with an enzyme-linked immunosorbent assay. The parameters (e.g., amount of ZrO2 NP, QD-anti-AChE concentration,) that govern the electrochemical response of immunosensors were optimized. The voltammetric response of the immunosensor is highly linear over the range of 10 pM to 4 nM paraoxon-AChE, and the limit of detection is estimated to be 8 pM. This new nanoparticle-based electrochemical immunosensor thus provides a sensitive and quantitative tool for biomonitoring exposure to OP pesticides and nerve agents.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗