Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volumetric water content”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Particle Size Measurements from the first Fundamentals of Ice Crystal Icing Physics Test in the NASA Propulsion Systems Laboratory

This presentation shows particle measurements by the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments from the first Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The work focuses on humidity sweeps at a larger and a smaller median volumetric diameter. The particle size distribution, number density, and water content measured by the Phase Doppler Interferometer and High Speed Imaging instruments from the sweeps are presented and compared. The current capability for these two instruments to measure and discriminate ICI conditions is examined.

thermal scaling↗

The Effect of Stainless Steel 304 Surface Roughness on Ice Adhesion Shear Strength of Accreted Impact Ice

Aircraft in-flight icing is problematic due to the ad-verse effect on vehicle performance. It occurs when supercooled water droplets (SCWD) present in clouds, under the appropriate environmental conditions, col-lide with the aircraft surface resulting in accretion of ice (i.e., impact icing). Impact ice can range from clear/glaze to rime or a combination of the two (i.e., mixed) with the type determined by the air temperature (0 to -20°C), liquid water content (LWC, 0.3-0.6 g/cu.m), and droplet size [median volumetric diameter (MVD) of 15-40 µm] present during accretion.1 These impact icing events generally occur at temperatures ranging from 0 to -20°C. Below -20°C, ice crystals dominate the environment and typically do not adhere to the aircraft surface. A main difference between an impact icing occurrence and a slow growth icing (i.e., freezer ice) one is the speed of the icing event. Besides environmental conditions, ice adhesion strength (IAS) to a metallic substrate depends upon surface roughness. It is known that increasing surface roughness and decreasing temperature lead to in-creases in IAS.

Smith, Joseph G., Jr.↗

A Study of Large Droplet Ice Accretion in the NASA Lewis IRT at Near-Freezing Conditions

Results of experiments designed to determine the effects of large droplet ice accretion on a NACA 23012 wing section are presented. Using primarily an icing condition with a median volumetric diameter droplet size of 160 micron and a liquid water content of 0.82 grams per cubic meter, the effects of various air temperatures, angles of attack, and de-icer boot cycle interval times on ice accretion were studied. Measurements of aerodynamic performance penalties due to the ice accretions were made. Results were also compared with similar tests conducted with a Twin Otter wing section in Part 1 of this study. The form of the ice from the large droplet cloud varied as a function of air total temperature; particularly at the near-freezing temperatures of 28 F to 34 F. Changing boot cycle interval time did not prevent formation of an ice ridge. The most detrimental aerodynamic effects occurred at an air total temperature of 28 F.

Addy, Harold E., Jr.↗

Improving Brightness Temperature Measurements near Coastal Areas for SMAP

The Soil Moisture Active Passive (SMAP) mission is designed to acquire L-band radiometer measurements for the estimation of soil moisture with 0.04 m3/m3 volumetric accuracy in the top 5 cm for vegetation with water content of less than 5 kg/m2. In regions near the coast or near inland bodies of water, the signal measured by the SMAP radiometer contains emissions from land and water, resulting in errors in the soil moisture estimation. In this paper, the effort to extract the brightness temperature (TB) according to the land fraction or water fraction (depending on the center of the footprint location) from the affected SMAP measurements was addressed. A single pixel correction algorithm was applied and its performance was evaluated over simulated data. A data-driven approach for the estimation of land and water TB for data correction was developed. The correction algorithm was then applied to real data and its performance was assessed over the SMAP soil moisture retrievals. We showed that the single pixel algorithm is an effective and computationally efficient algorithm for removing land or water TB contamination from the SMAP data.

Julian Chaubell↗

Ice Crystal Icing Investigation on a Honeywell Uncertified Research Engine in an Altitude Simulation Icing Facility

A Honeywell Uncertified Research Engine was exposed to various ice crystal conditions in the NASA Glenn Propulsion Systems Laboratory. Simulations using NASA's 1D Icing Risk Analysis tool were used to determine potential inlet conditions that could lead to ice crystal accretion along the inlet of the core flowpath and into the high pressure compressor. These conditions were simulated in the facility to develop baseline conditions. Parameters were then varied to move or change accretion characteristics. Data were acquired at altitudes varying from 5 kft to 45 kft, at nominal ice particle Median Volumetric Diameters from 20 µm to 100 µm, and total water contents of 1 g/m3 to 12 g/m3. Engine and flight parameters such as fan speed, Mach number, and inlet temperature were also varied. The engine was instrumented with total temperature and pressure probes. Static pressure taps were installed at the leading edge of the fan stator, front frame hub, the shroud of the IGV, and first two rotors. Metal temperatures were acquired for vane stators 1-2. In-situ measurements of the particle size distribution were acquired three meters upstream of the engine forward fan flange and one meter downstream of the fan in the bypass in order to study particle break-up behavior. Cameras were installed in the engine to capture ice accretions at the leading edge of the fan stator, splitter lip, and inlet guide vane. Additional measurements acquired but not discussed in this paper include: high speed pressure transducers installed at the trailing edge of the first stage rotor and light extinction probes used to acquire particle concentrations at the fan exit stator plane and at the inlet to the core and bypass. The goal of this study was to understand key parameters of accretion, acquire particle break-up data aft of the fan, and generate a unique icing dataset for model and tool development. This work described in the paper focuses on the effect of particle break-up. It was found that there was significant particle break-up downstream of the fan in the bypass especially with larger initial particle sizes. The metal temperatures on the inlet guide vanes and stators show a temperature increase with increasing MVD. Accretion behavior was very similar across all test cases. However at the inlet guide vanes, the accretion decreased with increasing particle size.

Ashlie B Flegel↗

Ice-Crystal Icing Investigation on a Honeywell Uncertified Research Engine in an Altitude Simulation Icing Facility

A Honeywell Uncertified Research Engine was exposed to various ice-crystal conditions in the NASA Propulsion Systems Laboratory (PSL). Simulations using NASA's one-dimensional (1D) Icing Risk Analysis tool were used to determine potential inlet conditions that could lead to ice-crystal accretion along the inlet of the core flowpath and into the high-pressure compressor. Baseline conditions were established, and parameters were varied to observe accretion characteristics. Data were acquired at altitudes varying from 5 kft to 45 kft, at nominal ice particle median volumetric diameters from 20 µm to 100 µm, and total water contents of 1 g/m3 to 12 g/m3. Metal temperatures were acquired for the inlet guide vane and vane stators 1–2. In situ measurements of the particle size distribution were acquired upstream and downstream of the engine fan face in order to study particle breakup behavior. Cameras were installed in the engine to capture ice accretions at the leading edge of the fan stator, splitter lip, and inlet guide vane. The goal of this study was to understand the key parameters of accretion, acquire particle breakup data aft of the fan, and generate a unique icing dataset for model development. Significant particle breakup downstream of the fan in the bypass was observed. The metal temperatures on the inlet guide vanes (IGVs) and stators show a temperature increase with increasing particle size. Accretion behavior at the fan stator and splitter lip across was very similar. However, accretion decreased with increasing particle size at the IGVs.

Ashlie B. Flegel↗

Enhancement of conventional concrete mix designs for sensible thermal energy storage applications

The study examines twenty-nine different concrete mix designs with varying constituents to improve thermal performance for energy storage at elevated temperatures up to 420 °C. Effects of variables including the type and volumetric percentage of coarse and fine aggregates, the type and replacement content of supplemental cementitious materials, water-to-cement ratio, the type and quantity of steel fiber reinforcement, and the inclusion of iron oxide powder are experimentally investigated by measuring the mechanical and thermal properties of each mix, with the overall goal of enhancing thermal performance and mitigating mechanical degradation for thermal energy storage (TES) applications. It is found that the use of siliceous aggregate with a high volumetric percentage produces the highest improvement (23 %–37 % at elevated temperatures) of concrete thermal conductivity, while silica fume replacement of Type I cement provides the highest improvement (4 %–8 % at elevated temperatures) of concrete specific heat. To simulate the operation of a TES system, thermal cycling was conducted to examine the change in concrete properties as a function of repetitive heating (during and after 50 total cycles to 420 °C). Based on the results of testing, concrete mix designs with high aggregate percentages (up to 72 % by volume), siliceous coarse aggregate, silica fume replacement of Type I cement (15 % by weight), and steel fiber reinforcement (up to 2 % by volume) facilitate enhanced TES performance by providing consistent thermal conductivity of ~2.2 W/m·K and specific heat of ~3.2 MJ/m 3 ·K under cyclic high temperature exposure.

25 ENERGY STORAGE↗

Soil nitrogen mineralization rates, nutrient stocks, stable isotopes, and water volumetric measurements across terrestrial-aquatic interfaces from three wetlands at the Tanglewood Biological Station, Alabama

This dataset supports a broader study investigating wetland hydrologic and biogeochemical responses to inundation events. Soil samples were collected across four sampling events along terrestrial-aquatic gradients at three wetland sites located within the Tanglewood Biological Station in Alabama from April 2024 to June 2025. The contents in this data package include soil in-situ nitrogen mineralization rates (measurements of net nitrification, net ammonification, and net mineralization), nutrient stocks (total carbon, total nitrogen, and organic matter), stable isotopes (carbon and nitrogen), and water volumetric measurements (water-filled pore space). Water level data related to each wetland location can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/2530253 (Kirker et al., 2024), related water geochemistry data can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3001967 (Forbes et al., 2025), and related surface water sediment chemistry data can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3377325 (Molina Serpas et al., 2026). In addition to this readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) file-level metadata; (2) data dictionary; (3) field metadata and international generic sample numbers (IGSNs); (4) readme; (5) the field protocol; and (6) a subfolder with sample data. The sample data subfolder contains (1) net nitrification rate, (2) net ammonification rate, (3) areal net mineralization rate, (4) percent organic matter, (5) water-filled pore space, (6) total carbon content, (7) total nitrogen content, (8) stable carbon isotope (delta carbon-13), and (9) stable nitrogen isotope (delta nitrogen-15), and (10) methods codes. All files are .csv or .pdf.

13-C↗

Liquid water content and droplet size calibration of the NASA Lewis Icing Research Tunnel

The icing research tunnel at the NASA Lewis Research Center underwent a major rehabilitation in 1986 to 1987, necessitating recalibration of the icing cloud. The methods used in the recalibration, including the procedure used to establish a uniform icing cloud and the use of a standard icing blade technique for measurement of liquid water content are described. PMS Forward Scattering Spectrometer and Optical Array probes were used for measurement of droplet size. Examples of droplet size distributions are shown for several median volumetric diameters. Finally, the liquid water content/droplet size operating envelopes of the icing tunnel are shown for a range of airspeeds and are compared to the FAA icing certification criteria.

Ide, Robert F.↗

Liquid water content and droplet size calibration of the NASA Lewis Icing Research Tunnel

The icing research tunnel at the NASA Lewis Research Center underwent a major rehabilitation in 1986 to 1987, necessitating recalibration of the icing cloud. The methods used in the recalibration, including the procedure used to establish a uniform icing cloud and the use of a standard icing blade technique for measurement of liquid water content are described. PMS Forward Scattering Spectrometer and Optical Array probes were used for measurement of droplet size. Examples of droplet size distributions are shown for several median volumetric diameters. Finally, the liquid water content/droplet size operating envelopes of the icing tunnel are shown for a range of airspeeds and are compared to the FAA icing certification criteria.

Ide, Robert F.↗

Soil physical and thermal properties from soil samples at multiple locations at Teller Road Site, Seward Peninsula, Alaska, 2019

This dataset contains results of the laboratory analysis of soil samples collected across the watershed located at miles #27 along the Teller road, near Nome, AK. The dataset includes 124 soil samples retrieved from 52 locations during the first week of August 2019. The soil samples were collected in the top 1.2 m of soil with volume known samples, analyzed with a thermal analyser to infer thermal parameters (thermal conductivity, volumetric heat capacity and thermal diffusivity), and then processed in a lab for estimation of their bulk density, water content, carbon and nitrogen content, soil texture, and elemental fractions. This dataset has one csv file and one pdf file.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

NASA Glenn Icing Research Tunnel: 2014 and 2015 Cloud Calibration Procedures and Results

This report summarizes the current status of the NASA Glenn Research Center (GRC) Icing Research Tunnel cloud calibration: specifically, the cloud uniformity, liquid water content, and drop-size calibration results from both the January-February 2014 full cloud calibration and the January 2015 interim cloud calibration. Some aspects of the cloud have remained the same as what was reported for the 2014 full calibration, including the cloud uniformity from the Standard nozzles, the drop-size equations for Standard and Mod1 nozzles, and the liquid water content for large-drop conditions. Overall, the tests performed in January 2015 showed good repeatability to 2014, but there is new information to report as well. There have been minor updates to the Mod1 cloud uniformity on the north side of the test section. Also, successful testing with the OAP-230Y has allowed the IRT to re-expand its operating envelopes for large-drop conditions to a maximum median volumetric diameter of 270 microns. Lastly, improvements to the collection-efficiency correction for the SEA multi-wire have resulted in new calibration equations for Standard- and Mod1-nozzle liquid water content.

aircraft icing↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15µm to 460 µm. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

Icing cloud instruments↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15m to 460 m. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

o Aircraft Icing↗

Isokinetic Probe Total Water Content Measurements in the NASA Icing Research Tunnel with Supercooled Large Drop Conditions

An Isokinetic Total Water Content Evaporator (IKP2) was used to measure liquid water content (LWC) in the NASA Icing Research Tunnel (IRT) with spray conditions that ranged in LWC and cloud drop size spectra as characterized by the median volumetric diameter (MVD). The IKP2 measurements were made as part of an international collaborative effort to investigate the measurement of supercooled large drop (SLD) conditions in several icing wind tunnels. This report focuses on the IKP2 and background water vapor (BWV) measurements made within the NASA IRT during the October 2017 test entry. The IKP2 TWC results are compared to the IRT LWC calibration values for a range of LWC and MVD values. The IRT LWC calibration is based on measurements from a multi-element hot-wire probe. In general, the IKP2 TWC values were approximately 9% greater than the IRT LWC calibration values over a range of LWC from 0.4 g/m3 to 3.0 g/m3. The ratio of IKP2 TWC to IRT LWC calibration ranged from approximately 0.9 to 1.27 over a range of MVD from 15um to 460 um. Comparisons of this data set to IKP2 data from a 2014 IRT test entry show similar results in the regions where overlaps occurred. The results support the theory and observations of water mass loss from hot-wire TWC sensors when subjected to large MVD conditions.

o Aircraft Icing↗

NIST: Soil Respiration, Moisture, Temperature, Chemistry; and Fine Root Measurements from a Transect Through a Forest Edge, Gaithersburg, Maryland, 2017-2021

This dataset contains soil respiration, moisture, temperature, and chemistry, as well as fine root measurements from the National Institute of Standards and Technology (NIST) Forested Optical Reference for Evaluating Sensor Technology (FOREST) research facility at Gaithersburg, Maryland. Measurements were taken at an existing transect array that begins in a grassy meadow, crosses a sharp forest edge, then a small stream, and finally extends upwards in the interior of the forest at the top of a ridge. There are 6 different landscape positions replicated across three transects in the array. Soil respiration was measured during growing seasons in 2017-2019 (2017-06-02 to 2020-02-27). Pedons (1 m3) were isolated from surrounding tree roots using trenching and a fabric to inhibit root ingrowth. Flux measurements inside the pedons were thus assumed to represent heterotrophic only respiration in 2019, and these fluxes were paired with nearby fluxes assumed to represent total respiration. Deep vertical probes measured volumetric moisture content and temperature at the same points in the array every 10 cm in depth to either 90 cm or 120 cm total depth, at 15 minute intervals, from 2019-2021 (2019-07-09 to 2021-09-10). Soil core samples were collected from each of the array points for three different months in early- to mid-2019 (2019-03-19 to 2019-07-10), at three depths each. Soils were analyzed for gravimetric moisture content; pH; total carbon, nitrogen, and phosphorus; texture; microbial biomass carbon, nitrogen, and phosphorus; extractable dissolved organic carbon, nitrogen, and phosphorus; extractable nitrate and ammonia; and extracellular hydrolytic enzyme activities. The fine roots were separated from the cores and segregated by plant functional type (grass or tree species) and if they were dead or alive. Fine roots were then measured for length, surface area, diameter, and dry mass. This dataset contains four data files in comma separated (*.csv) format. These data serve to deepen our understanding of root and soil processes at forest edges and in transitional zones.

54 ENVIRONMENTAL SCIENCES↗

The need for ion-exchange membranes with high charge densities

Ion-exchange membranes (IEMs) are essential for controlling ion transport in electrochemical membrane-based technologies for water purification, energy generation, and energy storage. In general, IEMs must exhibit high ionic conductivity and selectivity, both of which are significantly influenced by the charge and water content of the hydrated membrane. In this perspective, we compiled the charge and water contents of approximately 1,000 IEMs reported over the past several decades to assess their range and variability, as well as to reveal gaps and set clear targets for future membrane design. We compared the charge and water content of negatively and positively charged membranes, as well as membranes developed for desalination and energy applications. The majority of IEMs, regardless of structure or intended application, have volumetric charge densities below 3 mol/L[membrane]. This narrow range of charge densities limits the performance of IEMs and contributes to the observed tradeoff between ion throughput and selectivity. It is critical to develop IEMs with higher charge densities to overcome this performance limitation. Further, we highlighted several design strategies that yielded IEMs with fixed charge densities higher than 3 mol/L[membrane]. These strategies provide valuable insights and can guide the design of next-generation IEMs with high charge densities.

36 MATERIALS SCIENCE↗