Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Voltammetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Surface Analysis of 4-Aminothiophenol Adsorption at Polycrystalline Platinum Electrodes

Formation of self-assembled monolayer (SAM) of 4-aminothiophenol (4-ATP) on polycrystalline platinum electrodes has been studied by surface analysis and electrochemistry techniques. The 4-ATP monolayer was characterized by cyclic voltammetry (CV), Raman spectroscopy, reflection absorption infrared (RAIR) spectroscopy, and X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) experiments give an idea about the packing quality of the monolayer. RAIR and Raman spectra for 4-ATP modified platinum electrodes showed the characteristic adsorption bands for neat 4-ATP indicating the adsorption of 4-ATP molecules on platinum surface. The adsorption on platinum was also evidenced by the presence of sulfur and nitrogen peaks by XPS survey spectra of the modified platinum electrodes. High resolution XPS studies and RAIR spectrum for platinum electrodes modified with 4-ATP indicate that molecules are sulfur-bonded to the platinum surface. The formation of S-Pt bond suggests that ATP adsorption gives up an amino terminated SAM. Thickness of the monolayer was evaluated via angle-resolved XPS (AR-XPS) analyses. Derivatization of 4-ATP SAM was performed using 16-Br hexadecanoic acid.

Rosario-Castro, Belinda I.↗

Fundamental Investigation of Silicon Anode in Lithium-Ion Cells

Silicon is a promising and attractive anode material to replace graphite for high capacity lithium ion cells since its theoretical capacity is ~10 times of graphite and it is an abundant element on Earth. However, there are challenges associated with using silicon as Li-ion anode due to the significant first cycle irreversible capacity loss and subsequent rapid capacity fade during cycling. Understanding solid electrolyte interphase (SEI) formation along with the lithium ion insertion/de-insertion kinetics in silicon anodes will provide greater insight into overcoming these issues, thereby lead to better cycle performance. In this paper, cyclic voltammetry and electrochemical impedance spectroscopy are used to build a fundamental understanding of silicon anodes. The results show that it is difficult to form the SEI film on the surface of a Si anode during the first cycle; the lithium ion insertion and de-insertion kinetics for Si are sluggish, and the cell internal resistance changes with the state of lithiation after electrochemical cycling. These results are compared with those for extensively studied graphite anodes. The understanding gained from this study will help to design better Si anodes, and the combination of cyclic voltammetry with impedance spectroscopy provides a useful tool to evaluate the effectiveness of the design modifications on the Si anode performance.

Wu, James J.↗

Autonomous Measurement of Electrochemical Redox Couples for In-Situ Characterization of Enceladus Plume Samples

A 3D-printed microfluidic electrochemical cell with integrated electrodes was developed to demonstrate autonomous in-situ electrochemical characterization of terrestrial seawater samples. The system is designed to extend the capabilities of the 2008 Phoenix Lander’s Wet Chemistry Laboratory (WCL) that analyzed the soluble chemistry of the Martian soil, by miniaturizing its fluidic architecture for analysis of µL-volume samples as expected from an Enceladus fly-by mission. The microfluidic device has a total fluid volume of 48 µL and includes dual channels each populated with 7 electrodes. Measurement of pH was measured using an iridium oxide electrode. Cyclic voltammetry with Au, Pt, and glassy carbon working electrodes was used to measure redox couples in synthetic seawater that contained inorganic and bio-organic molecules. Glassy carbon was found to have minimal risk of interference from constituents of synthetic seawater when measuring molecular organic redox species; however, care must be used to prevent interference due to potential oxidation or dissolution in the case of Au working electrodes. A completely autonomous end-to-end run including sample delivery was performed, to demonstrate the feasibility of microfluidic-based cyclic voltammetry measurements for in-situ characterization of redox couples in Ocean World samples.

Planetary Instruments↗

Challenges in selecting appropriate electrodes for high-temperature molten salt systems

Based on a specific molten salt (e.g., chloride, fluoride, iodide) investigated, different working and reference electrode materials can be selected considering the chemical and thermal stability of the electrochemical cell components. In this talk, the electrode materials and challenges encountered with a spectro-electrochemical setup installed inside a glovebox, and the solutions implemented to address these challenges, specifically for the chloride and iodide molten salts will be presented. For molten chlorides, the fundamental interactions between neodymium chloride (NdCl3) and Nd metal in lithium chloride-potassium chloride eutectic salt were investigated at 773 K. The electrochemical transitions Nd2+,3+/Nd(s) were analyzed using an inert W electrode with cyclic voltammetry and chronoamperometry techniques, coupled with in-situ UV-Vis spectroscopy to elucidate the kinetic pathways of this disproportionation reaction (eq. 1). Nd(s) + NdCl3 = NdCl2 (1) For molten iodides, the challenges related to working electrode selectivity and present spectro-electrochemical results obtained from cyclic voltammetry measurements conducted at 673 K will be discussed.

36 - MATERIALS SCIENCE↗

Understanding the speciation of molten iodide salts via spectro-electrochemistry

Iodine is a high yield fission product of concern for the environmental effects due to its high volatility and biological impacts to the human body. Iodine speciation in molten salts, specifically iodide salts, is not well understood due to its reactivity at higher temperature domains. UV-Vis spectroscopy indicates a change in the speciation of the molten iodide salts starting at 500oC based on the decomposition of the salt itself, forming I3- ions. This work investigated the spectral changes of I- ions in molten LiI-KI and LiI-KI-NiI2 while manipulating the salts electrochemically using an inert graphite electrode at 400oC.The Li+/Li(s) and the Ni2+/Ni(s) transitions were studied using cyclic voltammetry, chronoamperometry/chronopotentiometry to characterize the respective reduction-oxidation waves. As cyclic voltammetry was applied, the UV-Vis spectroscopy showed a change in the characteristic signal of molten LiI-KI, indicating a disproportionation reaction in the molten salt, leading to formation of I3- ions and I2 gas.

36 - MATERIALS SCIENCE↗

Multielectrode Array Sensors to Enable Long-Duration Corrosion Monitoring and Control of Concentrating Solar Power Systems

Molten mixtures of MgCl2-KCl-NaCl are promising heat transfer fluid (HTF) candidates for the next generation of concentrating solar power systems (Gen3 CSP), because of their low cost, high decomposition temperature, and favorable heat transfer characteristics. However, if the chemistry of the salts is not properly controlled, molten chlorides can cause corrosion of high-temperature metal alloys, such as Inconel (R), in CSP systems. Here we demonstrate a corrosion monitoring system that can be used to monitor the health of the structural alloys over long durations. The monitoring system includes a multielectrode array voltammetry sensor that measures the redox potential of molten MgCl2-KCl-NaCl mixture as well as the presence of corrosion products and impurities. The sensors have been successfully operated in static molten salt environments for long durations, and are capable of detecting corrosion products, such as Cr2+ and Fe2+, quantitatively at low concentrations (i.e., approximately 100 ppm) with less than 4% error.

Concentrated solar power↗

Chiral Recognition: A Spin-Driven Process in Chiral Oligothiophene. A Chiral-Induced Spin Selectivity (CISS) Effect Manifestation

In this paper it is experimentally demonstrated that the electron-spin/molecular-handedness interaction plays a fundamental role in the chiral recognition process. This conclusion is inferred comparing current versus potential (I-V) curves recorded using chiral electrode surfaces, which are obtained via chemisorption of an enantiopure thiophene derivative: 3,3'-bibenzothiophene core functionalized with 2,2'-bithiophene wings (BT 2 T 4 ). The chiral recognition capability of these chiral-electrodes is probed via cyclic voltammetry measurements, where, Ag nanoparticles (AgNPs) capped with enantiopure (BT 2 T 4 ) (BT 2 T 4 )@AgNP) are used as the chiral redox probe. Then, the interface handedness is explored by recording spin-polarized (I-V) curves in spin-dependent electrochemistry (SDE) and magnetic-conductive atomic force microscopy (mc-AFM) experiments. The quality of the interfaces is thoroughly cross-checked using X-ray photoemission spectroscopy, Raman, electrodesorption measurements, which further substantiate the metal(electrode)-sulfur(thiophene) central role in the chemisorption process. Spin-polarization values of about 15% and 30% are obtained in the case of SDE and mc-AFM experiments, respectively.

36 MATERIALS SCIENCE↗

Highly Reversible Lithiation of Additive Free T‐Nb 2 O 5 for a Quarter of a Million Cycles

Abstract Fast energy storage via intercalation requires quick ionic diffusion and often results in pseudocapacitive behavior. The cycling stability of such energy storage materials remains understudied despite the relevance to lifetime cost. Orthorhombic niobium oxide (T‐Nb 2 O 5 ) is a rapid ion intercalation material with a theoretical capacity of 201.7 mAh g −1 (Li 2 Nb 2 O 5 ) and good cycling stability due to the minimal unit cell strain during (de)intercalation. Prior reports of T‐Nb 2 O 5 cycling between 1.3–3.1 V versus Li/Li + noted a 50% loss in capacity after 10 000 cycles. Here, cyclic voltammetry is used to identify the role of the voltage window, state of charge, and potentiostatic holds on the cycling stability of mesoporous T‐Nb 2 O 5 thin films. Films cycled between 1.2–3.0 V versus Li/Li + without voltage holds (Li 1.1 Nb 2 O 5 ) exhibited extreme cycling stability with 90.8% capacity retention after 0.25 million cycles without detectable morphological/crystallographic changes. In contrast, the inclusion of 60 s voltage holds (Li 2.18 Nb 2 O 5 ) led to rapid capacity loss with 61.6% retention after 10 000 cycles with corresponding X‐ray diffraction evidence of amorphization. Cycling with other limited voltage windows identifies that most crystallographic degradation occurs at higher extents of lithiation. These results reveal remarkable stability over limited conditions and suggest that T‐Nb 2 O 5 amorphization is associated with high extents of lithiation.

25 ENERGY STORAGE↗

Exciton Binding Energy in Organic Polymers: Experimental Considerations and Tuning Prospects

Discrepancies in reported values of exciton binding energy (E b ) for organic semiconductors (OSs) necessitate a comprehensive study. Traditionally, E b is defined as the difference between the transport gap (E t ) and the optical gap (E opt ). Here, the E b values of PBnDT‐TAZ polymer variants are determined using two commonly employed methods: a combination of ultraviolet photoemission spectroscopy and low‐energy inverse photoemission spectroscopy (UPS‐LEIPS) and solid‐state cyclic voltammetry (CV). E b values obtained by UPS‐LEIPS show low dispersion and no clear correlation with the polymer structure and thedielectric properties. In contrast, CV reveals a larger dispersion (200 meV‐1 eV) and an apparent qualitative E b ‐molecular structure correlation, as the lowest E b values are observed for oligo‐ethylene glycol side chains. This discrepancy is discussed by examining the implications of the traditional definition of E b . Additionally, the impact of both intrinsic and extrinsic factors contributing to the derived experimental values of E t is discussed. The differences in intrinsic and extrinsic factors highlight the context‐dependent nature of measurement when drawing global conclusions. Notably, the observed E b trend derived from CV is not intrinsic to the pure materials but likely linked to electrolyte swelling and associated changes in dielectric environment, suggesting that high‐efficiency single‐material organic photovoltaics with low E b may be possible via high dielectric materials.

36 MATERIALS SCIENCE↗

Imaginary admittance and charge transfer resistance correlate to the physiological status of Shewanella oneidensis cultures in real time

Monitoring microbial activity is essential for industrial and environmental applications to proceed efficiently. To minimize time and labor-intensive monitoring, a new paradigm is required for in-situ, real time analysis. Since bioconversion of organics is accomplished by microorganisms through the oxidation of feedstocks linked to the reduction of electron acceptors, microorganisms can be viewed as electrochemical catalysts. In this respect, cell membranes have an electrical potential, which is analogous to a conventional capacitor and linked dynamically to cellular activity. Here, in this study, we demonstrate the use of electrochemical impedance spectrometry (EIS) and cyclic voltammetry (CV) for monitoring microbial metabolic activity in real time, in-situ. The effect of organic electron donors as a function of concentration to the physiological status of strains of Shewanella oneidensis was determined. In this study, the pyomelanin overproducer (S. oneidensis ΔhmgA) and the pyomelanin deficient mutant (S. oneidensis ΔmelA) were chosen due to different surface electrochemical characteristics along with differences in oxygen utilization efficiency. CV, relative admittance, phase shift and permittivity changed with growth status and correlated with electron flow from organic carbon sources and terminal electron acceptor availability. This work offers a novel and inexpensive approach to real time monitoring with the advantage of abundant data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of impurity driven corrosion behavior in molten 2LiF-BeF 2 salt

A 1000 -h corrosion experiment of 316H stainless steel at 700 °C investigated the role of metal fluoride impurities CrF 2 and FeF 2 in LiF-BeF 2 (66-34 mole %) (FLiBe) salt. Inductively coupled plasma-optical emission spectroscopy (ICP-OES) demonstrated the ability to measure changes in the concentration of these fluorides in FLiBe salt. Cyclic voltammetry (CV) showed the potential for real-time quantitative concentration measurement of corrosion products in the molten salt. Materials characterization revealed that both impurity species influence the dissolution of Cr from the alloy. The collective results from these analysis methods advance the understanding of the influence impurities have on materials corrosion.

2LiF-BeF2↗

Deconvoluting sources of failure in lithium metal batteries containing NMC and PEO-based electrolytes

Solid-state lithium metal batteries (SSLMBs) containing polyethylene oxide (PEO)-derived polymer electrolytes and high-voltage (> 4 V vs. Li/Li + ) cathode materials suffer from three sources of failure: (1) instability between the polymer electrolyte and cathode at high voltage, (2) instability of the polymer electrolyte with Li metal, and (3) poorly-designed cathodes. In this study, these three sources of failure are deconvoluted by studying Ni-rich LiNi x Mn y Co 1-x-y O 2 (NMC, x ≥ 0.6) cathodes and a gel polymer electrolyte (GPE) derived from PEO. Initial cycling data reveals that rapid capacity fade occurs regardless of whether soft short circuits form due to Li dendrites. Cyclic voltammetry scans on cells featuring a Li metal electrode, GPE, and a NMC811 electrode free of additives suggest that there are no runaway reactions between the GPE and NMC811 up to 4.5 V vs. Li/Li + . Cathode/cathode symmetric cell cycling demonstrates that Li metal reactivity is a prime source of failure, though a poorly-designed cathode leads to subpar performance. A cathode with single-crystal NMC particles was demonstrated to achieve better initial capacity and longer cycle life, indicating room for improvement in SSLMB cathode design. Therefore, the sources of failure as enumerated may be ranked as follows from most to least concerning: 2 > 3 > 1.

25 ENERGY STORAGE↗

Functional roles of the [2Fe-2S] clusters in Synechocystis PCC 6803 Hox [NiFe]-hydrogenase reactivity with ferredoxins

The HoxEFUYH complex of Synechocystis PCC 6803 (S. 6803) consists of a HoxEFU ferredoxin:NAD(P)H oxidoreductase subcomplex and a HoxYH [NiFe]-hydrogenase subcomplex that catalyzes reversible H2 oxidation. Prior studies have suggested that the presence of HoxE is required for reactivity with ferredoxin; however, it is unknown how HoxE is functionally integrated into the electron transfer network of the HoxEFU:ferredoxin complex. Deciphering electron transfer pathways is challenged by the rich iron-sulfur cluster content of HoxEFU, which includes a [2Fe-2S] cluster in each subunit, along with multiple [4Fe-4S] clusters and a flavin cofactor. To resolve the role of HoxE, we determined the biophysical and thermodynamic properties of each [2Fe-2S] cluster in HoxEFU using steady-state and potentiometric EPR analysis in combination with square wave voltammetry (SWV). The temperature-dependence of the EPR signal for HoxE confirmed the coordination of a single [2Fe-2S] cluster that was shown by SWV to have an E m = -424 mV (versus SHE). Strikingly, when the E m of the HoxE [2Fe-2S] cluster was analyzed in HoxEFU titrations, it was shifted by >100 mV to an E m < -525 mV (versus SHE). EPR titrations of HoxEFU gave an E m value for the [2Fe-2S] cluster of HoxF, E m = -419 mV and HoxU, E m = -349 mV. These values were used to re-analyze the diaphorase kinetics in reactions performed with ferredoxins with varying E m 's. The results are formulated into a model of HoxEFU:ferredoxin reactivity and the role of HoxE in mediating electron transfer within the HoxEFU:ferredoxin complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diffusion coefficient and nucleation density studies on electrochemical deposition of aluminum from chloroaluminate ionic liquid electrolytes

In this study, aluminum was electrodeposited from ionic liquids comprising a melt of alkyl imidazolium chlorides and aluminum chloride (AlCl 3 ). The ionic liquids utilized in this study were 1-ethyl-3-methyl-imidazolium chloride (EMIC)-AlCl 3 , 1-butyl-3-methylimidazolium chloride (BMIC)-AlCl 3 , and 1-hexyl-3-methyl-imidazolium chloride (HMIC)-AlCl 3 at the AlCl 3 mole fraction of 0.667 (molar ratio of 1:2). The electrochemical behavior of chloroaluminate species in the three ionic liquids was investigated by cyclic voltammetry (CV) and chronoamperometry (CA) techniques at different temperatures. The cyclic voltammograms indicated that the reduction of Al 2 Cl 7 – species to metallic aluminum followed a diffusion-controlled phenomenon. Moreover, even at a less negative applied potential, the higher current density was obtained for EMIC-AlCl 3 ionic liquid. That indicates that EMIC-AlCl 3 favors less energy consumption during the electrodeposition. The chronoamperometric analysis revealed that the onset of aluminum deposition from such ionic liquids proceeds via a three-dimensional instantaneous nucleation process. The concentrations of Al 2 Cl 7 – ions in the ionic liquids were calculated based on the thermodynamic data, which were 2520, 2271, and 2035 mol m –3 for EMIC-AlCl 3 , BMIC-AlCl 3 , and HMIC-AlCl 3 , respectively. The diffusion coefficient (D) values of Al 2 Cl 7 – species in such ionic liquids were also calculated at various temperatures. The D values determined from the CA technique at 363 K are 2.16 × 10 –11 , 1.03 × 10 –11 , and 0.87 × 10 –11 m 2 s –1 for EMIC-AlCl 3 , BMICAlCl 3 , and HMIC-AlCl 3 , respectively. In addition, the D value increased as temperature increased and decreased as the hydrocarbon group in the ionic liquid increased. As a result, the calculated grain sizes of nucleation range from 2 to 4 μm for these ionic liquids and are in good agreement with experimental data obtained from SEM micrographs.

42 ENGINEERING↗

Electrochemical behavior of SnCl 2 and influence of Cu and Ni ions in molten LiCl−KCl−CaCl 2 eutectic

Reliable transport and thermodynamic data for multivalent ions in complex molten salts are scarce, limiting model fidelity for electrorefining and impurity control. Here, we report a comprehensive electrochemical characterization of SnCl₂ in LiCl–KCl–CaCl₂ (50.5–44.2–5.3 mol%) at 685 K, including the effects of Ni 2+ and Cu + impurities. Using cyclic voltammetry (CV), chronoamperometry (CA), and chronopotentiometry (CP), we quantified Sn 2+ and Ni 2+ diffusion with exceptional agreement across methods: Sn 2+ averaged (1.03 ± 0.10) × 10 −5 cm 2 s −1 , and Ni 2+ averaged (0.75 ± 0.19) × 10 −5 cm 2 s −1 . The tight confidence-interval overlap across CV, CA, and CP strengthens confidence in these values and is uncommon in molten chloride studies. Open-circuit-potential measurements provided standard apparent reduction potentials that closely match LiCl–KCl literature, indicating minimal shift with CaCl₂ present. The Sn 2+ /Sn couple behaves as a reversible two-electron soluble–insoluble process at 685 K; the Sn 4+ /Sn 2+ couple transitions to soluble–soluble behavior near 788 K, which may correlate with the decomposition of surface bound chlorostannates, though direct characterization remains to be established. In mixed systems, Cu+/Cu overlaps Sn 2+ /Sn, limiting Cusingle bondSn electroseparation, whereas the larger potential gap between Ni 2+ /Ni and Sn 2+ /Sn supports selective Ni removal. These internally consistent transport and thermodynamic data establish a validated basis for process modeling and optimization of Sn electrorefining and impurity management in LiCl–KCl–CaCl₂.

Berzins-Delahay↗

Influence of solvents on electrochemical stability window of ionic liquid solutions

The electrochemical stability window (ESW) defines the voltage range within which an electrolyte remains stable against oxidation and reduction, serving as a key descriptor for ionic liquid (IL)-based systems. The ESWs of 15 ILs with diverse cation-anion combinations were systematically investigated, both in their neat forms and as binary mixtures with three representative solvents, i.e., propylene carbonate (PC), ethylene glycol (EG), and tetrahydrofuran (THF). Cyclic voltammetry on a glassy carbon electrode determined anodic and cathodic stability limits, revealing that ESW protection in IL-solvent mixtures strongly depends on solvent polarity, proticity, and IL compatibility. PC, with a high dielectric constant and aprotic character, broadened anodic limits and moderately stabilized cathodic limits. THF maintained compact interfacial structure, offering additional cathodic protection, whereas EG, being protic, reduced ESWs via proton-coupled electron transfer and hydrogen evolution. The solvent protection trend followed by PC > THF > EG, with bulky, hydrophobic cations ([HMIM] + , [BMPYRR] + ) and weakly coordinating anions ([NTF 2 ] - , [DCA] - , [DEP] - ) showing the highest ESW protection for 50 mol% IL in these solvents. Among the neat ILs, [EMIM][DEP], [HMIM][PF 6 ], and [BMPYRR][DCA] showed wide ESWs of ∼5.5 V. These results provide valuable insight into solvent-modulated electrochemical stability, enabling rational design of IL-based electrolytes for energy storage and electrosynthesis.

25 ENERGY STORAGE↗

Voltammetric Measurement of Rates and Energetics for Surface Methoxylation of Si(100) in Methanol with Dissolved Electron Acceptors Using Si Ultramicroelectrodes

The steady-state voltammetric responses of n-type Si(100) semiconductor ultramicroelectrodes (SUMEs) immersed in air- and water-free methanolic electrolytes have been measured. The response characteristics of these SUMEs in the absence of illumination were modeled and understood through a framework that describes the distribution of the applied potential across the semiconductor/electrolyte contact using four discrete regions: the semiconductor space charge, surface, Helmholtz, and diffuse layers. The latter region was described by the full Gouy–Chapman model. This framework afforded insight on how relevant parameters such as the semiconductor band edge potentials, the reorganization energies for charge transfer, the standard potential of redox species in solution, the density and energy of surface state populations, and the presence of an insulating (tunneling) layer individually and collectively dictate the observable current–potential responses. With this information, the methoxylation of Si surfaces was evaluated by analysis of the change in voltammetric responses during the course of prolonged immersion in methanol. Here, the electrochemical data were consistent with a surface methoxylation mechanism that depended on the standard potential of redox species dissolved in solution. Estimates of the enthalpies of adsorption as well as the potential-dependent rate constant for surface methoxylation were obtained. Collectively, these measurements supported the contention that the rates of Si surface reactions can be systematically tuned by exposure to dissolved outer-sphere electron acceptors. Moreover, the data represent the quantitative utility of voltammetry with SUMEs for the measurement of semiconductor/liquid contacts.

14 SOLAR ENERGY↗

Self-Assembled Bolaamphiphile-Based Organic Nanotubes as Efficient Cu(II) Ion Adsorbents

Self-assembled organic nanotubes (ONTs) have been actively examined for various applications such as chemical separations and catalysis owing to their well-defined tubular nanostructures with distinct chemical environments at the wall and internal/external surfaces. Adsorption of heavy metal ions onto ONTs plays an essential role in many of these applications, but it has rarely been assessed quantitatively. Herein, we investigated interactions between Cu 2+ and single-/quadruple-wall bolaamphiphile-based ONTs having inner carboxyl groups with different inner diameters, COOH-ONT 10nm and COOH-ONT 20nm . We first examined the effects of Cu 2+ on their nanotubular structures using SAXS, STEM, and AFM. COOH-ONT 10nm was stable in aqueous Cu 2+ solution in contrast to COOH-ONT 20nm owing to the presence of polyglycine-II-type hydrogen bonding networks within its wall. Subsequently, we studied the Cu 2+ adsorption behavior of COOH-ONT 10nm by monitoring the concentration of unbound Cu 2+ using linear sweep anodic stripping voltammetry. The Cu 2+ adsorption was quick, attributable to efficient Cu 2+ partitioning through the open ends of the ONT, followed by fast Cu 2+ diffusion in the uniform, relatively large nanochannel. More importantly, the Cu 2+ adsorption capacity and affinity of COOH-ONT 10nm were measured at different pH using the Langmuir adsorption model. The adsorption capacity was similar at the pH range examined, showing the participation of approximately 25% of the inner carboxyl groups in the adsorption. The adsorption affinity increased with pH, indicating the essential role of the deprotonated carboxyl groups in the Cu 2+ adsorption. Most interestingly, the Langmuir adsorption constant was significantly higher than those of previously reported synthetic adsorbents and planar monolayer based on carboxyl binding sites. The high Cu 2+ affinity of the ONT was attributable to the highly dense binding sites on the well-defined nanoscale concave structure of the inner channel. Furthermore, these results provide a valuable guideline to designing self-assembled nanomaterials for efficient chemical separations, detection, and catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗