Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VISCOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Calculation of the critical cooling rate for amorphous Pd/77.5/Si/16.5/Cu/6/

The viscosity of the molten alloy Pd(77.5)Si(16.5)Cu(6) has been determined from 744 to 1000 C using an oscillating cup viscometer. Using these data (together with other pertinent physical data available for this alloy) in existing crystallization theory indicates that it could be made amorphous at cooling rates as low as 5-10 K/sec. This analysis assumes strictly homogeneous nucleation. Containerless solidification will be one good testing ground for the results of this analysis.

Steinberg, J.↗

Modeling of photodegradation in solar cell modules of substrate and superstrate design made with ethylene-vinyl acetate as pottant material

The rates of hydrogen abstraction by peroxy radicals were proven to be too slow for significant oxidation of the alkane substrate to be important. The numerical procedure, independent of our particular data base was verified by reproducing concentration time profiles for a model reaction set describing the cesium flare system in the upper atmosphere. Simulation was identical to that given in the literature. Experimental verification of the data base is to be attempted by weatherometry studies in the coming year. Work on the new diagnostic techniques was completed. The adapted automated viscometer was demonstrated to be an efficient and reliable tool for routine measurements of viscosity (molecular weight) changes in solid samples after batch solutions have been made up. The laser photolysis GC method for monitoring extremely low levels of oxidation in polymers proved to be impractical because the yields of carbon monoxide were too low for quantification. Much progress was made with the computer model. The reaction matrix was completely revised, resulting in a new scheme of 31 reactions and time, lifetimes in excess of ten years. The results to date lead us to some tentative observations.

Somersall, A. C.↗

Gas flow through rotameters

Using data available for small rotameters that use spherical floats in gas flow, a linear relationship is derived. It is noted that the relationship provides a good fit for variable volumetric flow, density, and viscosity at constant flow height. With low Reynolds numbers (Re being less than 1), the product of the variable volumetric flow and the viscosity becomes constant; at high Reynolds numbers (Re being greater than 2000), the product of the variable volumetric flow and the square root of the density becomes constant. It is pointed out that the equation given here can be used to obtain an indirect calibration with any gas of known density and viscosity. The constancy of the product of the variable volumetric flow and viscosity at low variable volumetric flows is seen as suggesting the development of simple, inexpensive gas viscometers using rotameter technology.

Levin, H.↗

Rheological study of clay-kaolin aqueous suspensions

Rheological characteristics of clay-kaolin aqueous suspensions were studied by a rotational viscometer to correlate their behavior with the properties of ceramic slips for casting containing quartz, feldspars, and other nonplastic materials. In particular, the effects of the different amounts of dry materials and deflocculant (mixture 1:1 of Na2CO3 and Na2SiO3) and of temperatures on the shear-time-dependent properties of suspensions were examined.

Lapasin, R.↗

High intensity 5 eV atomic oxygen source and Low Earth Orbit (LEO) simulation facility

An atomic oxygen exposure facility has been developed for studies of material degradation. The goal of these studies is to provide design criteria and information for the manufacture of long life (20 to 30 years) construction materials for use in LEO. The studies that are being undertaken using the facility will provide: absolute reaction cross sections for use in engineering design problems; formulations of reaction mechanisms; and calibration of flight hardware (mass spectrometers, etc.) in order to directly relate experiments performed in LEO to ground based investigations. The facility consists of: (1) a CW laser sustained discharge source of O atoms having a variable energy up to 5 eV and an intensity between 10(15) and 10(17) O atoms s(-1) cm(-2); (2) an atomic beam formation and diagnostics system consisting of various stages of differential pumping, a mass spectrometer detector, and a time of flight analyzer; (3) a spinning rotor viscometer for absolute O atom flux measurements; and (4) provision for using the system for calibration of actual flight instruments. Surface analysis equipment is available for the characterization of material surfaces before and after exposure to O atoms.

Cross, J. B.↗

High intensity 5 eV O-atom exposure facility for material degradation studies

An atomic oxygen exposure facility was developed for studies of material degradation. The goal of these studies is to provide design criteria and information for the manufacture of long life (20 to 30 years) construction materials for use in low Earth orbit. The studies that are being undertaken will provide: (1) absolute reaction cross sections for the engineering design problems, (2) formulations of reaction mechanisms for use in the selection of suitable existing materials and the design of new more resistant ones, and (3) the calibration of flight hardware (mass spectrometers, etc.) in order to directly relate experiments performed in low Earth orbit to ground based investigations. The facility consists of a CW laser sustained discharge source of O-atoms, an atomic beam formation and diagnostics system, a spinning rotor viscometer, and provision for using the system for calibration of actual flight instruments.

Cross, J. B.↗

The effect of fluid mechanical stress on cellular arachidonic acid metabolism

The effect of sublytic levels of mechanical perturations of cells on cell metabolism were investigated by analyzing the products of arachidonic acid (used as a marker metabolite) in blood platelets, polymorphonuclear leucocytes, and cultured umbilical-vein endothelial cells after the suspensions of these cells were subjected to a shear stress in a modified viscometer. It is shown that the sublytic levels of mechanical stress stimulated the arachidonic acid metabolism in all these cell types. Possible biological implications of this stress-metabolism coupling are discussed.

Mcintire, L. V.↗

The stimulation of arachidonic acid metabolism in human platelets by hydrodynamic stresses

The effects of stimulating human platelets by thrombin and by hydrodynamic stresses on the platelets' arachidonic acid metabolism were investigated using (1-C-14)-arachidonic acid label and a specially designed viscometer that ensured laminar shear flow with a nearly uniform shear rate throughout the flow region. It was found that platelets activated by thrombin formed principally thromboxane A2, 12-hydroxy 5,8,10-heptadecatrienoic acid and 12-hydroxy 5,8,10,14-eicosatetraenoic acid (12-HETE). On the other hand, platelets activated by shear, formed only 12-HETE (although arachidonic acid metabolism was stimulated); no cyclooxygenase metabolites were detected. Results indicate that platelets may greatly increase their 12-HETE production when activated by passage through a high-stress region of the circulation, such as an atherosclerotic stenosis.

Rajagopalan, Sridhar↗

Critical exponent for the viscosity of carbon dioxide and xenon

The viscosities of carbon dioxide and xenon have been measured near their critical points and the critical exponent y characterizing the asymptotic divergence has been determined. Both fluids yielded exponents in the range y = 0.041 + or - 0.001 and thus also fell in the range y = 0.042 + or - 0.002 from an earlier study of four binary liquids. This agreement between experiments is the first evidence that pure fluids and binary liquids are in the same dynamic universality class. A recent theoretical value for y is 0.032. The 30 percent discrepancy is much greater than the combined errors from experiment and theory. The torsion oscillator viscometer operated at low frequency and low shear rate to avoid systematic errors caused by critical slowing down. Far from T(c) the analysis accounted for the crossover from critical to noncritical temperature dependence, where the latter was obtained from previously published correlations. Corrections for gravitational stratification were included close to T(c).

Berg, R. F.↗

Processing of glass-ceramics from lunar resources

The goal is to fabricate useful ceramic materials from the by-products of lunar oxygen production processes. Specifically, the crystal nucleation and growth kinetics of ilmenite-extracted lunar regolith were studied in order to produce glass-ceramics with optimal mechanical, thermal, and abrasion resistant properties. In the initial year of the program, construction and calibration of a high temperature viscometer, used for determining the viscosity of simulated lunar glasses was finished. A series of lunar simulants were also prepared, and the viscosity of each was determined over a range of temperatures. It was found that an increase in the concentration of Fe2O3 decreases the viscosity of the glass. While this may be helpful in processing the glass, Fe2O3 concentrations greater than approximately 10 wt percent resulted in uncontrolled crystallization during viscosity measurements. Impurities (such as Na2O, MnO, and K2O) in the regolith appeared to decrease the viscosity of the parent glass. These effects, as well as those of TiO2 and SiO2 on the processability of the glass, however, remain to be quantified.

Fabes, B. D.↗

Rheological Behavior and Microstructure of Ceramic Particulate/Aluminum Alloy Composites

The rheological behavior and microstructure were investigated using a concentric cylinder viscometer for three different slurries: semi-solid alloy slurries of a matrix alloy, Al-6.5wt percent Si: composite slurries, SiC (sub p) (8.5 microns)/Al-6.5wt percent Si, with the same matrix alloy in the molten state, and composite slurries of the same composition with the matrix alloy in the semi-solid state. The pseudoplasticity of these slurries was obtained by step changes of the shear rate from a given initial shear rate. To study the thixotropic behavior of the system, a slurry was allowed to rest for different periods of time, prior to shearing at a given initial shear rate. In the continuous cooling experiments, the viscosities of these slurries were dependent on the shear rate, cooling rate, volume fraction of the primary solid of the matrix alloy, and volume fraction of silicon carbide. In the isothermal experiments, all three kinds of slurries exhibited non-Newtonian behavior, depending on the volume fraction of solid particles.

Moon, Hee-Kyung↗

Investigation of damping liquids for aircraft instruments

This report covers the results of an investigation carried on at the Bureau of Standards under a research authorization from, and with the financial assistance of, the National Advisory Committee for Aeronautics. The choice of a damping liquid for aircraft instruments is difficult owing to the range of temperature at which aircraft operate. Temperature changes affect the viscosity tremendously. The investigation was undertaken with the object of finding liquids of various viscosities otherwise suitable which had a minimum change in viscosity with temperature. The new data relate largely to solutions. The effect of temperature on the kinematic viscosity of the following liquids and solutions was determined in the temperature interval -18 degrees to +30 degrees C. (1) solutions of animal and vegetable oils in xylene. These were poppy-seed oil, two samples of neat's-foot oils, castor oil, and linseed oil. (2) solutions of mineral oil in xylene. These were Squibb's petrolatum of naphthene base and transformer oil. (3) glycerine solutions in ethyl alcohol and in mixture of 50-50 ethyl alcohol and water. (4) mixtures of normal butyl alcohol with methyl alcohol. (5) individual liquids, kerosene, mineral spirits, xylene, recoil oil. The apparatus consisted of four capillary-tube viscometers, which were immersed in a liquid bath in order to secure temperature control. The method of calibration and the related experimental data are presented.

Keulegan, G H↗

A comparison of calculated and measured rheological properties of crystallising lavas in the field and in the laboratory

Models of most magmatic processes, including realistic models of planetary lava flows require accurate data on the rheological properties of magma. Previous studies suggest that field and laboratory rheological properties of Hawaiian lavas can be calculated from their physico-chemical properties using a non-Newtonian rheology model. The present study uses new measurements of the rheological properties of crystallizing lavas to show that this is also true for lavas from Mount Etna. Rheological measurements on quenched Etna basalts were made in a specially designed furnace using a Haake Rotovisco viscometer attached to a spindle which has been designed to eliminate slippage at the melt-spindle interface. Using this spindle, we have made measurements at lower temperatures than other workers in this field. From these measurements, Mount Etna lavas are Newtonian at temperatures above 1120 C and they are thixotropic pseudoplastic fluids with a yield strength at lower temperatures. The close agreement between calculated and measured rheology over the temperature range 1084 - 1125 C support the use of the non-Newtonian rheology model in future modeling of planetary lava flows.

Pinkerton, Harry↗

Internal Waves in CVX

Near the liquid-vapor critical point, density stratification supports internal gravity waves which affect 1-g viscosity measurements in the CVX (Critical Viscosity of Xenon) experiment. Two internal-wave modes were seen in the horizontal viscometer. The frequencies of the two modes had different temperature dependences: with decreasing temperature, the higher frequency increased monotonically from 0.7 to 2.8 Hz, but the lower frequency varied non-monotonically, with a maximum of 1.0 Hz at 20 mK above the critical temperature. The measured frequencies agree with independently calculated frequencies to within 15%.

Berg, Robert F.↗

Viscosity of Hg(0.84)Zn(0.16)Te Pseudobinary Melt

An oscillating-cup viscometer was developed to measure viscosity of molten HgZnTe ternary semiconductor alloys. Data were collected for the pseudobinary Hg(0.84)Zn(0.16)Te melt between 770 and 850 C. The kinematic viscosity was found to vary from approximately 1.1 to 1.4 x 10(sup -3)sq cm/s. A slow relaxation phenomena was also observed for temperatures from the melting point of 770 to approx. 800 C. Possible mechanisms for this effect are discussed.

Mazuruk, K.↗

Methods of Viscosity Measurements in Sealed Ampoules

Viscosity of semiconductor and metallic melts is usually measured by oscillating cup method. This method utilizes the melts contained in vacuum sealed silica ampoules, thus the problems related to volatility, contamination, and high temperature and pressure can be alleviated. In a typical design, the time required for a single measurement is of the order of one hour. In order to reduce this time to a minute range, a high resolution (0.05 arc.sec) angular detection system is implemented in our design of the viscometer. Furthermore, an electromagnet generating a rotational magnetic field (RMF) is incorporated into the apparatus. This magnetic field can be used to remotely and non intrusively measure the electrical conductivity of the melt. It can also be used to induce a well controlled rotational flow in the system. The transient behavior of this flow can potentially yield the viscosity of the fluid. Based on RMF implementation, two novel viscometry methods are proposed in this work: a) the transient torque method, b) the resonance method. A unified theoretical approach to the three methods (oscillating cup, transient torque, and resonance) is presented along with the initial test results of the constructed apparatus. Advantages of each of the method are discussed.

Mazuruk, Konstantin↗

Structural Fluctuations and Thermophysical Properties of Molten II-VI Compounds

Recently, in support of the microgravity experiment entitled "Crystal Growth of Selected 11-VI Semiconducting Alloys by Directional Solidification," the viscosity of HgZnTe pseudobinary melt was measured using an oscillating-cup viscometer at NASA/Marshall Space Flight Center (MSFC). An unexpected time drift of the measured viscosity, which shows a slow relaxation phenomena at temperatures near the liquidus point, was reproducibly observed. Two sets of data were obtained by cooling the Hg(0.84)Zn(0.16)Te melt from 850 C and stabilizing at temperatures of 790 C, which is just above the liquidus temperature, and stabilizing at temperature of 810 C. While it took one day to reach equilibration at 810 C, five days were required at 790 C A similar relaxation phenomenon was also observed in the measured density of the same liquid. Furthermore, in the density measurements of the HgCdTe melts, which is the pseudobinary system studied in another flight experiment entitled "Growth of Solid Solution Single Crystals," a negative thermal expansion was reported. The liquid density increases from the liquidus point to a maximum value at a temperature approximately 700 C above the liquidus, where normal thermal expansion progressively resumes.

Su, Ching-Hua↗

Viscosity of Xenon Examined in Microgravity

Why does water flow faster than honey? The short answer, that honey has a greater viscosity, merely rephrases the question. The fundamental answer is that viscosity originates in the interactions between a fluid s molecules. These interactions are so complicated that, except for low-density gases, the viscosity of a fluid cannot be accurately predicted. Progress in understanding viscosity has been made by studying moderately dense gases and, more recently, fluids near the critical point. Modern theories predict a universal behavior for all pure fluids near the liquid-vapor critical point, and they relate the increase in viscosity to spontaneous fluctuations in density near this point. The Critical Viscosity of Xenon (CVX) experiment tested these theories with unprecedented precision when it flew aboard the Space Shuttle Discovery (STS-85) in August 1997. Near the critical point, xenon is a billion times more compressible than water, yet it has about the same density. Because the fluid is so "soft," it collapses under its own weight when exposed to the force of Earth s gravity - much like a very soft spring. Because the CVX experiment is conducted in microgravity, it achieves a very uniform fluid density even very close to the critical point. At the heart of the CVX experiment is a novel viscometer built around a small nickel screen. An oscillating electric field forces the screen to oscillate between pairs of electrodes. Viscosity, which dampens the oscillations, can be calculated by measuring the screen motion and the force applied to the screen. So that the fluid s delicate state near the critical point will not be disrupted, the screen oscillations are set to be both slow and small.

Zimmerli, Gregory A.↗