Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIBRATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Acoustical measurements of vibrational relaxation in moist N2 at elevated temperatures

Sound absorption measurements are conducted by the resonant tube technique to study vibrational relaxation in moist N2 at 301, 343, and 387 K. Analysis of the data shows that improved measurement accuracy at the higher temperatures establishes vibrational-vibrational energy transfer as the operative relaxation path for the de-excitation of N2 by H2O beyond the uncertainty of experimental error. The best-fitted temperature dependence of the vibrational-vibrational rate constant is given, noting that the expression is consistent with seven independent sets of both acoustical and nonacoustical data.

Zuckerwar, A. J.↗

Nonequilibrium vibrational population measurements in an expanding flow using spontaneous Raman scattering

Vibrational relaxation of nitrogen in a 2D nozzle flow is studied using spontaneous Raman scattering. An electric arc driven shock tube operating as a reflected shock tunnel produces stagnation conditions of 5600 K and 100 atm. A 248 nm KrF laser pulse is focused into the nozzle to produce spatially resolved spontaneous Raman spectra. Vibrational population distributions are derived from the spectra for the states v = 0 to v = 8. The experimental results are compared with two theoretical models: the Landau-Teller relaxation model and a numerical solution of the master equations using transition rates derived from SSH theory. The Landau-Teller correction factor has been measured at 1.0 - 1.5.

Sharma, Surendra P.↗

Compact Active Vibration Control System for a Flexible Panel

A diamond-shaped actuator for a flexible panel has an inter-digitated electrode (IDE) and a piezoelectric wafer portion positioned therebetween. The IDE and/or the wafer portion are diamond-shaped. Point sensors are positioned with respect to the actuator and measure vibration. The actuator generates and transmits a cancelling force to the panel in response to an output signal from a controller, which is calculated using a signal describing the vibration. A method for controlling vibration in a flexible panel includes connecting a diamond-shaped actuator to the flexible panel, and then connecting a point sensor to each actuator. Vibration is measured via the point sensor. The controller calculates a proportional output voltage signal from the measured vibration, and transmits the output signal to the actuator to substantially cancel the vibration in proximity to each actuator.

Schiller, Noah H.↗

Enhancement to Non-Contacting Stress Measurement of Blade Vibration Frequency

A system for turbo machinery blade vibration has been developed that combines time-of-arrival sensors for blade vibration amplitude measurement and radar sensors for vibration frequency and mode identification. The enabling technology for this continuous blade monitoring system is the radar sensor, which provides a continuous time series of blade displacement over a portion of a revolution. This allows the data reduction algorithms to directly calculate the blade vibration frequency and to correctly identify the active modes of vibration. The work in this project represents a significant enhancement in the mode identification and stress calculation accuracy in non-contacting stress measurement system (NSMS) technology when compared to time-of-arrival measurements alone.

Platt, Michael↗

Measurement of vibration rate of manually operated percussion machines

A special apparatus for measurement of accelerations of between 1 and 5000 g and shock stress pulses from 20 kg/cu cm up, with durations of 50.1 million sec and higher was designed and built. The amplitudes and shapes of the peak vibroshock pulses, arising during operation of a hammer, are obtained; the recording time of the continuous process is determined by the time of one revolution of the drum of a specially made mechanical photo attachment.

Aleksandrov, Y. V.↗

Rocket engine vibration accurately measured by photography

High speed instrumentation camera focused on a partially masked light bulb which is securely mounted to the test fixture permits measurement of engine performance parameters when usual electronic vibration instrumentation is unavailable. Vibration is recorded as a light trace deviating from the light rays photographed in the static hardware condition.

Craig, K. A.↗

Vibrational spectra of nanowires measured using laser doppler vibrometry and STM studies of epitaxial graphene : an LDRD fellowship report.

A few of the many applications for nanowires are high-aspect ratio conductive atomic force microscope (AFM) cantilever tips, force and mass sensors, and high-frequency resonators. Reliable estimates for the elastic modulus of nanowires and the quality factor of their oscillations are of interest to help enable these applications. Furthermore, a real-time, non-destructive technique to measure the vibrational spectra of nanowires will help enable sensor applications based on nanowires and the use of nanowires as AFM cantilevers (rather than as tips for AFM cantilevers). Laser Doppler vibrometry is used to measure the vibration spectra of individual cantilevered nanowires, specifically multiwalled carbon nanotubes (MWNTs) and silver gallium nanoneedles. Since the entire vibration spectrum is measured with high frequency resolution (100 Hz for a 10 MHz frequency scan), the resonant frequencies and quality factors of the nanowires are accurately determined. Using Euler-Bernoulli beam theory, the elastic modulus and spring constant can be calculated from the resonance frequencies of the oscillation spectrum and the dimensions of the nanowires, which are obtained from parallel SEM studies. Because the diameters of the nanowires studied are smaller than the wavelength of the vibrometer's laser, Mie scattering is used to estimate the lower diameter limit for nanowires whose vibration can be measured in this way. The techniques developed in this thesis can be used to measure the vibrational spectra of any suspended nanowire with high frequency resolution Two different nanowires were measured - MWNTs and Ag{sub 2}Ga nanoneedles. Measurements of the thermal vibration spectra of MWNTs under ambient conditions showed that the elastic modulus, E, of plasma-enhanced chemical vapor deposition (PECVD) MWNTs is 37 {+-} 26 GPa, well within the range of E previously reported for CVD-grown MWNTs. Since the Ag{sub 2}Ga nanoneedles have a greater optical scattering efficiency than MWNTs, their vibration spectra was more extensively studied. The thermal vibration spectra of Ag{sub 2}Ga nanoneedles was measured under both ambient and low-vacuum conditions. The operational deflection shapes of the vibrating Ag{sub 2}Ga nanoneedles was also measured, allowing confirmation of the eigenmodes of vibration. The modulus of the crystalline nanoneedles was 84.3 {+-} 1.0 GPa. Gas damping is the dominate mechanism of energy loss for nanowires oscillating under ambient conditions. The measured quality factors, Q, of oscillation are in line with theoretical predictions of air damping in the free molecular gas damping regime. In the free molecular regime, Q{sub gas} is linearly proportional to the density and diameter of the nanowire and inversely proportional to the air pressure. Since the density of the Ag{sub 2}Ga nanoneedles is three times that of the MWNTs, the Ag{sub 2}Ga nanoneedles have greater Q at atmospheric pressures. Our initial measurements of Q for Ag{sub 2}Ga nanoneedles in low-vacuum (10 Torr) suggest that the intrinsic Q of these nanoneedles may be on the order of 1000. The epitaxial carbon that grows after heating (000{bar 1}) silicon carbide (SiC) to high temperatures (1450-1600) in vacuum was also studied. At these high temperatures, the surface Si atoms sublime and the remaining C atoms reconstruct to form graphene. X-ray photoelectron spectroscopy (XPS) and scanning tunneling microscopy (STM) were used to characterize the quality of the few-layer graphene (FLG) surface. The XPS studies were useful in confirming the graphitic composition and measuring the thickness of the FLG samples. STM studies revealed a wide variety of nanometer-scale features that include sharp carbon-rich ridges, moire superlattices, one-dimensional line defects, and grain boundaries. By imaging these features with atomic scale resolution, considerable insight into the growth mechanisms of FLG on the carbon-face of SiC is obtained.

36 MATERIALS SCIENCE↗

Measurement of Vibrational Non-Equilibrium in a Supersonic Freestream Using Dual-Pump CARS

Measurements have been conducted at the University of Virginia Supersonic Combustion Facility of the flow in a constant area duct downstream of a Mach 2 nozzle, where the airflow has first been heated to approximately 1200 K. Dual-pump CARS was used to acquire rotational and vibrational temperatures of N2 and O2 at two planes in the duct at different downstream distances from the nozzle exit. Wall static pressures in the nozzle are also reported. With a flow of clean air, the vibrational temperature of N2 freezes at close to the heater stagnation temperature, while the O2 vibrational temperature is about 1000 K. The results are well predicted by computational fluid mechanics models employing separate "lumped" vibrational and translational/rotational temperatures. Experimental results are also reported for a few percent steam addition to the air and the effect of the steam is to bring the flow to thermal equilibrium.

Cutler, Andrew D.↗

Subsynchronous vibrations in a high pressure centrifugal compressor: A case history

Two distinct aerodynamically excited vibrations in a high pressure low flow centrifugal compressor are documented. A measured vibration near 21% of running speed was identified as a nonresonant forced vibration which results from rotating stall in the diffuser; a measured vibration near 50% of running speed was identified as a self excited vibration sustained by cross coupling forces acting at the compressor wheels. The dependence of these characteristics on speed, discharge pressure, and changes in bearing design are shown. The exciting mechanisms of diffuser stall and aerodynamic cross coupling are evidenced. It is shown how the rotor characteristics are expected to change as a result of modifications. The operation of the compressor after the modifications is described.

Evans, B. F.↗

The application of laser induced predissociation fluorescence to the measurement of vibrational temperatures in a shock layer flow

Single shot spatially and spectrally resolved laser induced predissociation fluorescence measurements in a shock layer around a cylinder in a pulsed supersonic free stream are presented. Fluorescence signals were produced using the tuned output of an argon fluoride excimer laser to excite a mixture of rovibrational transitions in molecular oxygen. The signals produced along a line inside the shock layer were focussed onto a two dimensional detector coupled to a spectrometer, thus allowing spectral and spatial resolution of the fluorescence. In this way, it was possible to detect two fluorescence signals from two different transitions simultaneously, allowing the determination of vibrational temperatures without the need for calibration. However, to minimize problems associated with low signal to noise ratios, background subtraction and spatial averaging was required. The experimental measurements are compared with theoretical inviscid shock layer calculations for nonequilibrium air. A description of the strategies employed in these calculations is also provided.

Sutton, D. J.↗

Residual acceleration data on IML-1: Development of a data reduction and dissemination plan

The need to record some measure of the low-gravity environment of an orbiting space vehicle was recognized at an early stage of the U.S. Space Program. Such information was considered important for both the assessment of an astronaut's physical condition during and after space missions and the analysis of the fluid physics, materials processing, and biological sciences experiments run in space. Various measurement systems were developed and flown on space platforms beginning in the early 1970's. Similar in concept to land based seismometers that measure vibrations caused by earthquakes and explosions, accelerometers mounted on orbiting space vehicles measure vibrations in and of the vehicle due to internal and external sources, as well as vibrations in a sensor's relative acceleration with respect to the vehicle to which it is attached. The data collected over the years have helped to alter the perception of gravity on-board a space vehicle from the public's early concept of zero-gravity to the science community's evolution of thought from microgravity to milligravity to g-jitter or vibrational environment. Since the advent of the Shuttle Orbiter Program, especially since the start of Spacelab flights dedicated to scientific investigations, the interest in measuring the low-gravity environment in which experiments are run has increased. This interest led to the development and flight of numerous accelerometer systems dedicated to specific experiments. It also prompted the development of the NASA MSAD-sponsored Space Acceleration Measurement System (SAMS). The first SAMS units flew in the Spacelab on STS-40 in June 1991 in support of the first Spacelab Life Sciences mission (SLS-1). SAMS is currently manifested to fly on all future Spacelab missions.

Rogers, Melissa J. B.↗

New perspective on iron-ligand vibrations of oxyheme complexes.

We report our studies of the vibrational dynamics of iron for three imidazole-ligated oxyheme derivatives that mimic the active sites of histidine-ligated heme proteins complexed with dioxygen. The experimental vibrational data are obtained from nuclear resonance vibrational spectroscopy (NRVS) measurements conducted on both powder samples and oriented single crystals, and which includes several in-plane (ip) and out-of-plane (oop) measurements. Vibrational spectral assignments have been made through a combination of the oriented sample spectra and predictions based on density functional theory (DFT) calculations. The two Fe-O{sub 2} modes that have been previously observed by resonance Raman spectroscopy in heme proteins are clearly shown to be very strongly mixed and are not simply either a bending or stretching mode. In addition, a third Fe-O{sub 2} mode, not previously reported, has been identified. The long-sought Fe-Im stretch, not observed in resonance Raman spectra, has been identified and compared with the frequencies observed for the analogous CO and NO species. The studies also suggest that the in-plane iron motion is anisotropic and is controlled by the orientation of the Fe-O{sub 2} group and not sensitive to the in-plane Fe-N{sub p} bonds and/or imidazole orientations.

59 BASIC BIOLOGICAL SCIENCES↗

Detectability prediction for a thermoacoustic sensor in the breazeale nuclear reactor pool

Laboratory experiments have suggested that thermoacoustic engines can be in- corporated within nuclear fuel rods. Such engines would radiate sounds that could be used to measure and acoustically-telemeter information about the op- eration of the nuclear reactor (e.g., coolant temperature or uxes of neutrons or other energetic particles) or the physical condition of the nuclear fuel itself (e.g., changes in temperature, evolved gases) that are encoded as the frequency and/or amplitude of the radiated sound [IEEE Measurement and Instrumen- tation 16(3), 18-25 (2013)]. For such acoustic information to be detectable, it is important to characterize the vibroacoustical environments within reactors. Measurements will be presented of the background noise spectra (with and with- out coolant pumps) and reverberation times within the 70,000 gallon pool that cools and shields the fuel in the 1 MW research reactor on Penn State's campus using two hydrophones, a piezoelectric projector, and an accelerometer. Sev- eral signal-processing techniques will be demonstrated to enhance the measured results. Background vibrational measurement were also taken at the 250 MW Advanced Test Reactor, located at the Idaho National Laboratory, using ac- celerometers mounted outside the reactor's pressure vessel and on plumbing will also be presented. The detectability predictions made in the thesis were validated in September 2015 using a nuclear ssion-heated thermoacoustic sensor that was placed in the core of the Breazeale Nuclear Reactor on Penn State's campus. Some features of the thermoacoustic device used in that experiment will also be revealed. [Work supported by the U.S. Department of Energy.]

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic Tester For Rotor Seals And Bearings

Simplified apparatus measures performance under vibration. Measures some of dynamic parameters of rotor seals and bearings. Tests damping seals, damping bearings, conventional seals, and conventional bearings. Used with variety of pumped liquids, from water to liquid oxygen or hydrogen. Designed to test bearings and seals of turbopumps, tester rotates shaft at high speed while liquid flows much as it would in real turbopump. Also measures deflections of components.

Von Pragenau, George L.↗

Environmental Qualification of a Single-Crystal Silicon Mirror for Spaceflight Use

This innovation is the environmental qualification of a single-crystal silicon mirror for spaceflight use. The single-crystal silicon mirror technology is a previous innovation, but until now, a mirror of this type has not been qualified for spaceflight use. The qualification steps included mounting, gravity change measurements, vibration testing, vibration- induced change measurements, thermal cycling, and testing at the cold operational temperature of 225 K. Typical mirrors used for cold applications for spaceflight instruments include aluminum, beryllium, glasses, and glass-like ceramics. These materials show less than ideal behavior after cooldown. Single-crystal silicon has been demonstrated to have the smallest change due to temperature change, but has not been spaceflight-qualified for use. The advantage of using a silicon substrate is with temperature stability, since it is formed from a stress-free single crystal. This has been shown in previous testing. Mounting and environmental qualification have not been shown until this testing.

Hagopian, John↗